TRANE BAS-SVN231D-EN Symbio 500 Programmable Controller

Espesifikasyon
- Depo: Temperature: Relative Humidity: Between 5% to 95% (non-condensing)
- Fonksyone: Temperature: Humidity: Between 5% to 95% (non-condensing)
- Pouvwa: Mounting Weight of Mounting surface must support 0.80 lb. (0.364 kg) Controller
- Anviwònman: NEMA 1 Rating (Enclosure), Plenum Rating: Not plenum rated. The Symbio 500 must be mounted within a rated enclosure when installed in a plenum.
Enstriksyon Itilizasyon Pwodwi
Depo ak Kondisyon Fonksyònman
Ensure the controller is stored and operated within the specified temperature and humidity ranges to maintain optimal performance.
Enstriksyon pou monte
Pou monte aparèy la:
- Hook the device over the top of the DIN rail.
- Gently push on the lower half of the device in the direction of the arrow until the release clip clicks into place.
To remove/reposition the device:
- Dekonekte tout konektè anvan yo retire oswa repozisyon.
- Insert a screwdriver into the slotted release clip and gently pry upward to disengage the clip.
- While holding tension on the clip, lift the device upward to remove or reposition it.
- If repositioned, push on the device until the release clip clicks back into place to secure it on the DIN rail.
Symbio 500 kontwolè pwogramasyon milti-bi yo itilize nan yon seri aplikasyon tèminal.
Avètisman, Avètisman, ak Avi
Li manyèl sa a byen anvan ou opere oswa fè sèvis sou aparèy sa a. Konsèy sekirite parèt nan tout manyèl sa a jan sa nesesè. Sekirite pèsonèl ou ak bon fonksyonman machin sa a depann de respè strik prekosyon sa yo.
Twa kalite konsèy yo defini jan sa a:
- AVÈTISMAN Endike yon sitiyasyon potansyèlman danjere ki, si yo pa evite, ka lakòz lanmò oswa blesi grav.
- ATANSYON Endike yon sitiyasyon potansyèlman danjere ki, si yo pa evite, ta ka lakòz blesi minè oswa modere. Li ta ka itilize tou pou avèti kont pratik danjere.
- AVI Endike yon sitiyasyon ki ka lakòz ekipman oswa domaj nan pwopriyete sèlman aksidan.
Enkyetid Anviwònman Enpòtan
Rechèch syantifik yo montre ke sèten pwodui chimik ki fèt lèzòm kapab afekte kouch ozòn stratosferik natirèl latè a lè yo lage nan atmosfè a. An patikilye, plizyè nan pwodui chimik yo idantifye ki ka afekte kouch ozòn lan se frigorigènes ki gen klò, fliyò ak kabòn (CFC) ak sa yo ki gen idwojèn, klò, fliyò ak kabòn (HCFC). Se pa tout frigorigènes ki gen konpoze sa yo ki gen menm enpak potansyèl sou anviwònman an. Trane defann manyen responsab tout frigorigènes.
Pratik Responsab Refrijeran Enpòtan
Trane kwè ke pratik refrijeran responsab yo enpòtan pou anviwònman an, kliyan nou yo ak endistri èkondisyone. Tout teknisyen ki okipe frigorigènes dwe sètifye selon règleman lokal yo. Pou Etazini, Lwa Federal Clean Air (Seksyon 608) tabli egzijans pou manyen, rekiperasyon, rekiperasyon, ak resiklaj sèten frigorigènes ak ekipman yo itilize nan pwosedi sèvis sa yo. Anplis de sa, kèk eta oswa minisipalite ka gen kondisyon adisyonèl ki dwe respekte tou pou jesyon responsab refrijeran yo. Konnen lwa ki aplikab yo epi swiv yo.
AVÈTISMAN
Bon fil elektrik jaden ak tè obligatwa! Si w pa suiv kòd sa a, sa ka lakòz lanmò oswa blesi grav. Tout fil elektrik DWE dwe fèt pa pèsonèl kalifye. Fil elektrik jaden ki pa byen enstale ak tè poze poze danje DIFE ak ELEKTROCUTION. Pou evite danje sa yo, ou DWE swiv egzijans pou enstalasyon fil kouran ki deyò ak tè jan sa dekri nan NEC ak kòd elektrik lokal/eta/nasyonal ou.
AVÈTISMAN
Ekipman Pwoteksyon Pèsonèl (PPE) Obligatwa!
Si w pa mete PPE apwopriye pou travay k ap fèt la, sa ka lakòz lanmò oswa blesi grav. Teknisyen yo, pou yo ka pwoteje tèt yo kont danje elektrik, mekanik ak chimik, DWE swiv prekosyon ki nan manyèl sa a ak sou tags, avek stickers son, ak etikèt, osi byen ke enstriksyon ki anba yo:
- Anvan w enstale/sèvis inite sa a, teknisyen yo DWE mete tout PPE ki nesesè pou travay k ap fèt la (Egamples; gan ki reziste koupe/manch rad, gan butyl, linèt sekirite, chapo di/bouchon boul, pwoteksyon tonbe, PPE elektrik ak rad flash arc). TOUJOU al gade nan Fich Done Sekirite (SDS) ak direktiv OSHA ki apwopriye pou PPE apwopriye.
- Lè w ap travay avèk oswa ozalantou pwodui chimik danjere, TOUJOU refere ak direktiv ki apwopriye SDS ak OSHA/GHS (Global Harmonized System of Classification and Labeling of Chemicals) pou jwenn enfòmasyon sou nivo ekspoze pèsonèl akseptab, pwoteksyon respiratwa apwopriye ak enstriksyon sou manyen.
- Si gen yon risk pou kontak elektrik kouran, arc, oswa flash, teknisyen yo DWE mete tout PPE an akò ak OSHA, NFPA 70E, oswa lòt kondisyon espesifik nan peyi a pou pwoteksyon arc flash, AVAN yo fè sèvis inite a. PA JANM FÈ OKENN BOUKE, DEKONEKTE, OSWA VOLTAGE TÈS SAN PPE ELEKTRIK AK BON RAD FLASH AK. ASIRE KI MÈT ELEKTRIK AK EKIPMAN YO BYEN KLASSE POU VOL KI GENYEN.TAGE.
AVÈTISMAN
Swiv Règleman EHS!
Si w pa suiv enstriksyon ki pi ba yo, sa ka lakòz lanmò oswa blesi grav.
- Tout pèsonèl Trane dwe swiv règleman Anviwònman, Sante, ak Sekirite (EHS) konpayi an lè yo fè travay tankou travay cho, elektrik, pwoteksyon tonbe, bloke/tagkote règleman lokal yo pi sevè pase règleman sa yo, règleman sa yo ranplase règleman sa yo.
- Pèsonèl ki pa Trane ta dwe toujou swiv règleman lokal yo.
AVÈTISMAN
Cancer and Reproductive Harm! This product can expose you to chemicals including lead and bisphenol A (BPA), which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Copyright
Dokiman sa a ak enfòmasyon ki ladan l yo se pwopriyete Trane, epi yo pa ka itilize oswa repwodui an antye oswa an pati san pèmisyon alekri. Trane rezève dwa pou revize piblikasyon sa a nenpòt ki lè, epi fè chanjman nan kontni li yo san yo pa obligasyon pou notifye nenpòt moun sou revizyon oswa chanjman sa yo.
Trademark
All trademarks referenced in this document are the trademarks of their respective
pwopriyetè yo.
Nimewo lòd
Order Number/Description
- BMSY500AAA0100011 Symbio 500 Programmable Controller
- BMSY500UAA0100011 Symbio 500 Programmable Controller
Espesifikasyon Depo / Fonksyònman
| Depo | |
| Tanperati: | -67 ° F a 203 ° F (-55 ° C a 95 ° C) |
| Imidite relatif: | Ant 5% a 95% (ki pa kondanse) |
| Opere | |
| Tanperati: | -40 ° F a 158 ° F (-40 ° C a 70 ° C) |
| Imidite: | Ant 5% a 95% (ki pa kondanse) |
| Pouvwa: | 20.4–27.6 Vac (24 Vac, ±15% nominal) 50–60 Hz, 24 VA
For specifics on transformer sizing, see Symbio™500Programmable Controller Installation, Operation, and Maintenance (BAS-SVX090*-EN). |
| Mounting pwa nan kontwolè: | Sifas monte dwe sipòte 0.80 lb (0.364 kg) |
| Evalyasyon anviwònman an (anvlòp): | NEMA 1 |
| Evalyasyon Plenum: | Pa plen rated. Symbio 500 la dwe monte nan yon patiraj nominal lè enstale nan yon plenn. |
Ajans Konfòmite
- UL60730-1 PAZX (Open Energy Management Equipment)
- UL94-5V Enflamabilite
- CE make
- UKCA make
- FCC Pati 15, Sou-pati B, Klas B Limit
- VCCI-CISPR 32:2016: Klas B Limit
- AS/NZS CISPR 32:2015: Klas B Limit
- CAN ICES-003(B)/NMB-003(B)
Dimansyon/Monte/Retire Kontwolè a

Pou monte aparèy:
- Kwòk aparèy sou tèt ray DIN.
- Dousman pouse sou mwatye pi ba aparèy la nan direksyon flèch la jiskaske clip lage a klike sou plas li.

Pou retire/repozisyon aparèy:
- Dekonekte tout konektè anvan yo retire oswa repozisyon.
- Insert the screwdriver into slotted release clip and gently pry upward with the screwdriver to disengage the clip.
- While holding tension on the clip, lift the device upward to remove or reposition.

If repositioned, push on the device until the release clip clicks back into place to secure the device on the DIN rail. Slotted release clip shown from back side.
AVI
Domaj nan patiraj! Si w pa swiv enstriksyon ki pi ba yo, sa ka lakòz domaj nan patiraj plastik la. Pa sèvi ak fòs twòp pou enstale kontwolè a sou ray DIN la. Si w ap itilize ray DIN yon lòt manifakti, swiv enstalasyon yo rekòmande.
AVÈTISMAN
Danjere Voltage! Si w pa dekonekte kouran anvan ou fè sèvis, sa ka lakòz lanmò oswa blesi grav. Dekonekte tout kouran elektrik, ki gen ladan dekonekte aleka anvan ou fè sèvis. Swiv bon jan bloke/ tagsoti pwosedi yo asire pouvwa a pa ka envolontè kouran. Verifye ke pa gen kouran ak yon voltmèt.
ATANSYON
Proper Ground Connection Required! Failure to follow instructions below could result in death or serious injury.After installation, ensure that the 24 Vac transformer is grounded through the controller. Measure the voltage ant tè chasi ak nenpòt tèminal tè sou kontwolè a. Rezilta espere: Vac <4.0 volt.
Kondisyon pou fil elektrik
Pou asire bon operasyon kontwolè a, enstale sikwi ekipman pou pouvwa a an akò ak direktiv sa yo:
- Kontwolè a dwe resevwa pouvwa AC nan yon sikwi pouvwa dedye; echèk yo konfòme yo ka lakòz kontwolè a fonksyone byen.
- Yon switch dekonekte sikwi pouvwa devwe dwe toupre kontwolè a, fasil pou operatè a aksesib, epi make kòm aparèy dekonekte pou kontwolè a.
- PA kouri fil kouran AC nan menm pake fil ak fil antre/sòti; echèk yo konfòme yo ka lakòz kontwolè a fonksyone byen akòz bri elektrik.
- 18 AWG fil kwiv rekòmande pou kous la ant transfòmatè a ak kontwolè a.
Rekòmandasyon transfòmatè
The controller can be powered with 24VAC. Use of a 24 Vac power supply is recommended in order to use the spare 24 Vac outputs for powering relays and TRIACs.
- Kondisyon pou transfòmatè AC: UL ki nan lis, transformateur pouvwa klas 2, 24 Vac ± 15%, chaj max aparèy 24 VA. Transfòmatè a dwe gwosè pou bay kontwolè a ase pouvwa ak rezilta yo.
- Enstalasyon CE-konfòme: transfòmatè a dwe make CE ak SELV konfòme pa estanda IEC.
AVI
Domaj ekipman!
Sharing 24 VAC power between controllers could result in equipment damage
A separate transformer is recommended for each controller. The line input to the transformer must be equipped with a circuit breaker sized to handle the maximum transformer line current. If a single transformer is shared by multiple controllers:
- Transfòmatè a dwe gen ase kapasite
- Polarite dwe konsève pou chak kontwolè ki mache ak transfòmatè a
Enpòtan: Si yon teknisyen ranvèse polarite envolontè ant kontwolè ki mache ak menm transfòmatè a, yon diferans 24 Vac ap fèt ant teren chak kontwolè. Sentòm sa yo ka lakòz:
- Pèt kominikasyon pasyèl oswa total sou tout lyen BACnet® la
- Move fonksyon nan pwodiksyon kontwolè
- Domaj nan transfòmatè a oswa yon fusible transfòmatè kònen
Fil elektrik AC pouvwa
To wire AC power
- Konekte tou de fil segondè ki soti nan transfòmatè 24 Vac ak tèminal XFMR yo sou aparèy la.
- Asire aparèy la byen chita.
Enpòtan: This device must be grounded for proper operation! The factory-supplied ground wire must be connected from any chassis ground connection on the device (
) nan yon tè ki apwopriye (
). The chassis groundconnection used may be the 24 Vac transformer input at the device, or any other chassis ground connection on the device.
Nòt: Aparèy la pa chita atravè koneksyon tren DIN la.
Nòt: Yo ta dwe itilize yon koneksyon pigtail ant tè chasi a sou aparèy la ak yon tè tè, si aparèy la pa chita nan yon sèl janm nan fil elektrik transfòmatè a.
Demaraj ak Tcheke Pouvwa
- Verifye ke konektè 24 Vac a ak tè chasi a byen branche.
- Chak aparèy dwe gen yon adrès inik ak valab. Se adrès la mete lè l sèvi avèk switch rotary adrès yo. Adrès ki valab yo se 001 jiska 127 pou aplikasyon BACnet MS/TP ak 001 jiska 980 pou aplikasyon Trane Air-Fi ak BACnet IP.
Enpòtan: A duplicate address or a 000 address will cause communication problems in a BACnet link: The Tracer SC+ will not discover all devices on the link, and the installation process will fail after discovery. - Retire blokaj la/tagsoti nan liy lan voltage pouvwa nan kabinè elektrik la.
- Aplike pouvwa a kontwolè a epi obsève sekans chèk pouvwa ki anba a:
Pouvwa dirije limyè wouj pou 1 segonn. Lè sa a, li chanje nan vèt, ki endike ke inite a byen demare ak pare pou kòd aplikasyon an. Flache wouj endike ke yon kondisyon fay egziste. Ou ka itilize zouti sèvis Tracer® TU a pou tcheke si gen defo apre yo fin chaje kòd aplikasyon ak pwogramasyon TGP2.
Antre / Sòti Fil elektrik
AVI
Domaj ekipman!
Failure to follow instructions below could result in damage to the controller, power transformer, or input/output devices due to inadvertent connections to power circuits. Remove power to the controller before making input/output connections. Pre-power checks of input/output devices should be performed according to the Symbio™500 Programmable Controller – Installation, Operation, and Maintenance (BAS-SVX090*-EN). Maximum wire lengths are as follows:
| Maksimòm Longè Fil | ||
| Kalite | Antre | Sòti yo |
| Binè | 1,000 pye (300 m) | 1,000 pye (300 m) |
| 0 - 20 mA | 1,000 pye (300 m) | 1,000 pye (300 m) |
| 0 – 10 Vdc | 300 pye (100 m) | 300 pye (100 m) |
| Thermistor/rezistif | 300 pye (100 m) | Pa aplikab |
| • All wiring must be in accordance with the NEC and local codes.
• Use only 18–22 AWG (1.02 mm to 0.65 mm diameter), stranded, tinned-copper, shielded, twisted-pair wire. • Analog and 24 Vdc output wiring distances are dependent on the receiving unit specifications. • DO NOT run input/output wires or communication wires in the same wire bundle with AC power wires. |
||
Tès Tug pou Konektè Tèminal
If using terminal connectors for wiring, strip the wires to expose 0.28-inch (7 mm) of bare wire. Insert each wire into a terminal connector and tighten the terminal screws. A tug test is recommended after tightening terminal screws to ensure that all wires are secure.
BACnet MS/TP Link Wiring
BACnet MS/TP lyen fil elektrik dwe apwovizyone jaden ak enstale an konfòmite ak NEC ak kòd lokal yo. Anplis de sa, fil la dwe kalite sa a: kapasite ki ba, 18 kalib, bloke, fèblan kòb kwiv mete, pwoteje, pè trese. Polarite dwe konsève ant tout aparèy ki sou lyen an.
Fil elektrik BACnet IP
The Symbio™ 500 supports BACnet IP. The device requires a category 5E or newer Ethernet cable with an RJ-45 plug connector. The cable can be plugged into either port on the controller.
Examples de Câblage
Analog Input/Output Wiring Terminals Are Top Tier

Fil elektrik ekipman pou TRIAC
Chanjman segondè-bò; metòd fil elektrik tipik
Low-side Chanje; minimize risk pou yo boule pwodiksyon binè akòz bout pantalon inadvèrtans nan tè a. 
Espesifikasyon Antre / Sòti
| Kalite Antre / Sòti | Kantite | Kalite | Range | Nòt |
|
Antre analòg (AI1 rive AI5)) |
5 |
tèrmik |
10kΩ – Kalite II, 10kΩ – Kalite III, 2252Ω – Kalite II,
20kΩ - Kalite IV, 100 kΩ |
Antre sa yo ka konfigire pou kapasite pase kwonometre. Sipòte *, ** pou detèktè zòn Trane. |
|
RTD |
Balco™ (Ni-Fe) 1kΩ, 385 (Pt) 1kΩ, 375 (Pt) 1kΩ, 672 (Ni) 1kΩ, |
— |
||
| Setpoint (moin pous) | 189Ω a 889Ω | — | ||
| Rezistan | 100Ω pou 100kΩ | Tipikman yo itilize pou switch vitès fanatik. | ||
|
Antre inivèsèl (UI1 ak UI2) |
2 |
Kouran lineyè | 0-20mA |
Antre sa yo ka konfigirasyon yo dwe tèmistè oswa antre reziste, antre 0–10 Vdc, oswa antre 0–20 mA. |
| Lineary Voltage | 0-10Vdc | |||
|
tèrmik |
10kΩ – Kalite II, 10kΩ – Kalite III, 2252Ω – Kalite II,
20kΩ - Kalite IV, 100 kΩ |
|||
|
RTD |
Balco™ (Ni-Fe) 1kΩ, 385 (Pt) 1kΩ, 375 (Pt) 1kΩ, 672 (Ni) 1kΩ, | |||
| Setpoint (moin pous) | 189 W a 889 W | |||
| Rezistan | 100Ω pou 100kΩ | |||
| Binè | Kontak sèk | Kontak relè ba enpedans. | ||
| Batman kè akimilatè | Eta solid pèseptè louvri | Tan pou rete minimòm se 25 milisgond ON ak 25 milisgond OFF. | ||
| Antre binè (BI1 a BI3) |
3 |
— |
24 Vac detekte |
Kontwolè a bay 24Vac ki nesesè pou kondwi entrain binè yo lè w ap itilize koneksyon rekòmande yo. |
| Sòti binè (BO1 rive BO3) |
3 |
Fòm C Relè |
0.5A @ 24Vac devwa pilòt |
Ranje yo bay yo se pou chak kontak. Pouvwa a bezwen branche nan pwodiksyon binè a. Tout pwodiksyon yo izole youn ak lòt ak soti nan tè oswa pouvwa. |
| Sòti binè (BO4 rive BO9) |
6 |
Triak |
0.5A @ 24Vac rezistan ak devwa pilòt |
Ranje yo bay yo se pou chak kontak ak pouvwa soti nan kous la TRIAC SUPPLY. Itilize pou modulation TRIAC yo. Itilizatè detèmine si fèmen bò segondè (bay voltage nan chaj la tè) oswa bò ki ba (bay tè a chaj pouvwa a). |
|
AnalogOutput/BinaryInput (AO1/BI4 and AO2/BI5) |
2 |
Kouran lineyè | 0 - 20mA |
Chak revokasyon dwe configuré kòm swa yon pwodiksyon analòg oswa yon opinyon binè. |
| Lineary Voltage | 0 - 10Vdc | |||
| Antre binè | Kontak sèk | |||
| Batman kè Lajè modulation | 80 Hz siyal @ 15Vdc | |||
| Antre presyon (PI1 ak PI2) |
2 |
— |
0-5 nan H20 |
Antre presyon apwovizyone ak 5 vòlt (ki fèt pou transducteur presyon Kavlico™). |
| Pwen total | 23 | — | — | — |
Nòt: Symbio 500 pwodiksyon binè yo pa konpatib ak voltages over 24 Vac.
Modil ekspansyon
If additional inputs/outputs are needed, the Symbio™ 500 will support an additional 110 (133 total) inputs/outputs. See Tracer XM30, XM32, XM70, and XM90 Expansion Modules – Installation, Operation, and Maintenance (BAS-SVX46*-EN) for more information.
Modil Wi-Fi
Si yo itilize Trane Wi-Fi, Symbio 500 sipòte swa modil:
- X13651743001 Wi-Fi Field Enstale Twous, 1 m kab, 70C
- X13651743002 Wi-Fi Field Enstale Twous, 2.9 m kab, 70C
Trane - pa Trane Technologies (NYSE: TT), yon inovatè klima mondyal - kreye konfòtab, enèji efikas anviwònman andedan kay la pou aplikasyon pou komèsyal ak rezidansyèl yo. Pou plis enfòmasyon, tanpri vizite trane.com oswa tranetechnologies.com. Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices.BAS-SVN231D-EN 07 Oct 2025 Supersedes BAS-SVN231C-EN (Apr 2023)
Kesyon yo poze souvan
Ki moun ki ta dwe enstale ak sèvis ekipman an?
Only qualified personnel should install and service the equipment as it involves specific knowledge and training to prevent hazardous situations.
What are the environmental ratings for the controller?
The controller has a NEMA 1 enclosure rating and is not plenum rated. It must be mounted within a rated enclosure when installed in a plenum.
What are the consequences of improper field wiring and grounding?
Improper field wiring and grounding could pose fire and electrocution hazards, emphasizing the importance of following code requirements and having qualified personnel perform all field wiring.
Why is personal protective equipment (PPE) required?
Failure to wear proper PPE could result in death or serious injury due to potential electrical, mechanical, and chemical hazards. Technicians must follow precautions to protect themselves.
Dokiman / Resous
![]() |
TRANE BAS-SVN231D-EN Symbio 500 Programmable Controller [pdfGid Enstalasyon BAS-SVN231D-EN, BAS-SVX090 -EN, BAS-SVN231D-EN Symbio 500 Programmable Controller, BAS-SVN231D-EN, Symbio 500 Programmable Controller, 500 Programmable Controller, Programmable Controller, Controller |