SoliTek SOLID Series Solar Modules

Itilizasyon Enstriksyon
- Read this guide entirely before installation.
- This document provides minimum requirements and recommendations for safe and successful installation of SoliTek PV modules and is necessary to retain compliance with IEC 61215, IEC 61730, and UL 61730 standards.
- This guide provides basic information on JSC SoliTek Cells SOLID series photovoltaic modules, including their installation and safe handling.
- All instructions should be read and understood before attempting installation. Contact your dealer or JSC SoliTek Cells for further information if needed.
- This documentation refers to the PV modules themselves and is not a comprehensive installation manual for personnel not specifically trained in PV modules.
- It serves as a general but strictly mandatory reference for the installer. Infringement or inaccurate observance of any clause in this documentation voids the warranty.
- The installer must understand and follow all applicable local, state, and federal regulations and standards for building construction, electrical design, fire, and safety.
- Check with local authorities for permitting requirements before installing or maintaining PV modules, and become familiar with mechanical and electrical requirements for photovoltaic systems.
- Si w pa suiv enstriksyon ki nan gid sa a, sa ka andomaje konpozan sistèm yo, mete pèsonèl yo an danje, domaje pwopriyete oswa anile garanti panèl la.
- Rooftop PV systems should only be installed on dwellings formally analyzed for structural integrity and confirmed to be capable of handling the additional weighted load of PV system components (including PV modules) by a certified building specialist or engineer.
KONDISYON JENERAL
- Tanpri li gid sa a nèt anvan enstalasyon an.
- Objektif dokiman sa a se pou bay egzijans minimòm ak rekòmandasyon pou enstalasyon modil SoliTek PV san danje epi reyisi.
- Dokiman sa a genyen tou kondisyon ki nesesè pou kenbe modil SoliTek PV konfòmite ak estanda IEC 61215, IEC 61730, UL 61730.
- Gid sa a gen enfòmasyon debaz konsènan modil fotovoltaik JSC "SoliTek Cells" seri SOLID, enstalasyon yo ak manyen san danje. Tout enstriksyon yo ta dwe li ak konprann anvan ou eseye enstalasyon. Si gen nenpòt kesyon, tanpri kontakte konsesyonè w la oswa JSC "SoliTek Cells" pou plis enfòmasyon.
- This documentation refers to the PV-modules themselves and is not meant to be a complete installation manual for personnel not specifically trained to PV-modules.
- It serves as a general but strictly mandatory reference for the Installer.
- Vyolasyon oswa obsèvasyon kòrèk nan nenpòt kloz nan dokiman sa a anile garanti a.
- Enstalatè a dwe konprann epi swiv tout règleman ak estanda lokal, eta ak federal ki aplikab pou konstriksyon bilding, konsepsyon elektrik, dife, ak sekirite, epi li dwe tcheke avèk otorite lokal yo pou detèmine egzijans otorizasyon ki aplikab yo anvan li eseye enstale oswa kenbe modil PV epi li ta dwe vin abitye ak kondisyon mekanik ak elektrik pou sistèm fotovoltaik.
- Si w pa swiv enstriksyon ki nan gid sa a, sa ka andomaje konpozan sistèm yo, mete pèsonèl yo an danje, domaje pwopriyete oswa anile garanti panèl la.
- Sistèm PV twati yo ta dwe enstale sèlman sou kay ki te analize fòmèlman pou entegrite estriktirèl ak konfime ke yo kapab jere chaj adisyonèl pondéré nan eleman sistèm PV, ki gen ladan modil PV, pa yon espesyalis bilding sètifye oswa enjenyè.
- For your safety, do not attempt to work on a rooftop until safety precautions have been identified and taken, including, without limitation fall protection measures, ladders or stairways, and personal protective equipment (PPE).
- For your safety, do not install or handle PV modules under adverse conditions, including, without limitation strong or gusty winds, and wet or frosted roof surfaces.
- Konstriksyon modil PV plat-plak la konsiste de yon asanble laminated selil solè ankapsule nan yon materyèl posibilite nan de fèy vè.
- Kenbe dokiman sa yo nan yon kote ki an sekirite pou referans nan lavni.
- Pa eseye demonte modil la, epi pa retire okenn plak ak konpozan ki tache! Si w fè sa, sa pral anile garanti a.
Manyen ak aplikasyon
MANYEN
- SoliTek PV modules must be transported in the supplied packaging only and kept in the packaging until they are ready to be installed.
- Protect pallets against movement and exposure to damage during transportation. Secure pallets from falling over.
- Pa depase wotè maksimòm palèt yo dwe anpile, jan sa endike sou anbalaj la palèt.
- Store pallets in a cool and dry location until the PV modules are ready to be unpackaged.
- SoliTek PV modules are heavy and should be handled with care. Never use the junction box or cables as a grip.
- Do not exert mechanical stress on the cables.
- Never step on PV modules or drop or place heavy objects on them.
- Be careful when placing PV modules on hard surfaces and secure them from falling.
- Broken glass can result in personal injury. PV modules with broken glass cannot be repaired and must not be used.
- Broken or damaged PV modules must be handled carefully and disposed of properly.
APLIKASYON
Restriksyon yo
- SoliTek PV modules must be mounted on appropriate mounting structures positioned on suitable buildings, the ground, or other structures suitable for PV modules (e.g. carports, building facades or PV trackers).
- PV modules must not be mounted on moving vehicles of any kind. Modules must not be installed in locations where they could be submerged in water.
- Do not install modules above 2000 m (6561 ft) altitude above sea level
- Limyè konsantre atifisyèlman pa dwe dirije sou modil SoliTek PV.
Rekòmandasyon
- SoliTek rekòmande pou yo monte modil PV nan yon ang enklinezon minimòm de 10 degre pou pèmèt pwòp pwòp tèt ou netwayaj kont lapli.
- Lonbraj pasyèl oswa konplè nan yon modil PV oswa modil ka siyifikativman diminye pèfòmans sistèm.
- SoliTek rekòmande pou minimize kantite lonbraj pandan tout ane a pou ogmante kantite enèji ki pwodui nan modil PV yo.
- Sistèm segondè voltages could be induced in the event of an indirect lightning strike, which could cause damage to PV system components.
- The open area of wire loops should be minimized in order to reduce the risk of lightning-induced voltage monte.
- Pi bon vantilasyon modil ak pi kout kab koneksyon ogmante pwodiksyon enèji elektrik.
Pou modil bifasyal:
- Li rekòmande pou ogmante wotè panèl PV soti nan tè a pou plis limyè ka vwayaje anba modil la ak Lè sa a, reflete
- Benefis bifacial la ogmante siyifikativman si modil yo enstale anwo sifas blan (valè albedo segondè), limyè-reflete.
Enstalasyon elektrik
SEKIRITE
- Modil PV ka pwodwi aktyèl ak voltage lè ekspoze a limyè nan nenpòt entansite. Kouran elektrik ogmante ak entansite limyè ki pi wo. DC voltage nan 50 Volts oswa pi wo se potansyèlman letal. Lè w kontakte sikwi a ap viv nan yon sistèm PV opere anba limyè ka lakòz chòk elektrik letal.
- De-energize modil PV pa retire yo antyèman nan limyè oswa lè yo kouvri sifas devan yo ak yon materyèl opak. Konsènan règleman sekirite pou ekipman elektrik vivan lè w ap travay ak modil ki ekspoze a nenpòt limyè. Sèvi ak zouti izole epi pa mete bijou metalik pandan w ap travay ak modil PV.
- Pou evite arcing ak chòk elektrik, pa dekonekte koneksyon elektrik anba chaj. Koneksyon defo ka lakòz tou arcing ak chòk elektrik. Kenbe konektè sèk ak pwòp epi asire yo ke yo nan bon kondisyon travay. Pa janm mete objè metalik nan konektè yo oswa modifye yo nan okenn fason pou sekirize yon koneksyon elektrik.
- Do not touch or handle PV modules with broken glass unless the PV modules are first disconnected, and you are wearing proper PPE. Avoid handling PV modules when they are wet unless cleaning the PV modules as directed in this manual. Never touch electrical and wet connections without protecting yourself with insulated gloves.
- The modules are qualified for Class II protection against electrical shock, in accordance with clause 4 of IEC 61730-1:2016, which can be used in systems operating at > 50 V DC or >240 W, where general contact access is anticipated and modules qualified for safety through UL 61730 within this application class are considered to meet the requirements of Safety Class II.
- Enstale sistèm solè fotovoltaik mande pou konpetans espesyalize ak konesans. Li ta dwe fèt sèlman pa pèsonèl ki kalifye ak enstriksyon espesyal. Enstalatè a sipoze tout risk pou yo blese, ki gen ladan risk pou chòk elektrik.
- Sèvi ak sèlman ekipman, konektè, fil elektrik ak pyès ki nan konpitè aliye ki fèt espesyalman pou itilize nan yon sistèm fotovoltaik.
- Before any manipulation at an installed PV plant, switch it off first on the AC-side, and then on the DC side of the inverter or the charge controller.
- Lè dekonekte fil ki konekte nan yon modil fotovoltaik ki ekspoze a limyè, yon arc elektrik ka rive. Arcs ka lakòz boule, kòmanse dife, oswa otreman kreye pwoblèm sekirite (jiska letal chòk elektrik).
- Tcheke pou rès voltage before starting and observe the local safety-relevant regulations for such working conditions.
- Anba kondisyon nòmal, yon modil fotovoltaik ka pwodwi plis aktyèl ak/oswa voltage (isit la: 30V DC) pase rapòte nan kondisyon tès estanda.
- Kontakte ak yon vol DCtage nan 30 V oswa plis se potansyèlman danjere. Egzèsis prekosyon lè fil elektrik oswa manyen modil ekspoze a limyè solèy la.
- Sèlman konekte modil ak menm aktyèl pwodiksyon nominal nan seri. Si modil yo konekte nan seri, total voltage egal a sòm volim modil endividyèl latages.
- Sèlman konekte modil oswa seri konbinezon modil ak menm voltage in parallel. If modules are connected in parallel, the total current is equal to the sum of the individual module or series combination currents.
- Toujou itilize menm kalite modil nan yon sistèm fotovoltaik patikilye.
- If the sum of short circuit currents of the parallel-connected modules exceeds the reverse current, string diodes or fuses have to be used in each string of modules connected in parallel. These string diodes or fuses have to be qualified for the maximum expected current and voltage. The fuse rating value is also corresponds to the maximum reverse current that a module can withstand. The reverse current value can be found on the product label, in the product datasheet or in chapter 8 of the installation manual. Observe the instructions and safety precautions for all other components used in the system, including wiring and cables, connectors, DC-breakers, inverters, etc.
- Sèvi ak ekipman sekirite apwopriye (zouti izole, gan dyelèktrik, soulye ak elatriye) apwouve pou itilize sou enstalasyon elektrik.
KONFIGURASYON
- Anba kondisyon nòmal, yon modil fotovoltaik gen chans rive nan fè eksperyans kondisyon ki pwodui plis aktyèl ak / oswa voltage than reported at Standard Test Conditions (STC: 1000 W/ m2, AM 1.5, and 250C/770F cell temperature) or Bifacial nominal power index(BNPl front irradiance 1000 W/m2, back irradiance 135 W/m2 AM 1.5, and 25 OC/770F cell temperature). The short-circuit current (ISC) should be multiplied by a factor of 1.25 and the open-circuit voltage (VOC) ta dwe miltipliye pa yon faktè ki rive jiska 1.25 ki baze sou tanperati anbyen ki pi ba ak pi wo anrejistre pou kote enstalasyon an lè w ap detèmine volim konpozan.tagEvalyasyon, evalyasyon aktyèl kondiktè, gwosè fuse, ak gwosè kontwòl ki konekte ak pwodiksyon PV la.
- Voltages yo aditif lè modil PV yo konekte dirèkteman nan seri, ak kouran modil yo aditif lè modil PV yo konekte dirèkteman nan paralèl. Modil PV ak diferan karakteristik elektrik pa dwe konekte dirèkteman nan seri. Itilizasyon aparèy elektwonik apwopriye twazyèm pati ki konekte ak modil PV ka pèmèt diferan koneksyon elektrik epi yo dwe enstale dapre enstriksyon manifakti a espesifye.
- Vol maksimòm lantage of serial interconnection of the modules must be less than the maximum certified module’s system voltage. Tou, D' maksimòm voltage nan varyateur la ak nan lòt aparèy elektrik yo nan sistèm nan dwe pran an kont. The open circuit voltage of the array string needs to be calculated at the lowest expected a mbient temperature forthe location. The maximal system voltage for the module is indicated in the module’s datasheet.
- Accordingly, for BLACKSTAR, SOLID or MAGNUS series modules, the values of ISC and VOC under STC or BNPI marked on this module should be multiplied by a factor of 1,25 when determining component voltage ratings, conductor current ratings, fuse sizes, and size of controls connected to the PV output. In the USA, referto Section 690-8 of the National Electrical Code (N EC) for an additional multiplying factor of 125 percent (80 percent de-rating) which may be applicable.
APARÈY PWOTEKSYON SOU KORENANT (OCPD)
- When the potential reverse current of a PV string exceeds the rated SoliTek PV module series fuse rating (values indicated at the module datasheet) an overcurrent protection device (OCPD) must be used.
- An overcurrent protection device is required for each series string if more than two series are connected in parallel.
- In this case, it is needed to use one fuse per string rated at 1.25 x Isc or higher (Isc is the PV module’s short circuit current at STC). A PV fuse on each PV string will protect the PV modules and conductors from overcurrent faults and help minimize any safety hazards.
- The PV fuse will also isolate the faulted PV string so the balance of the PV system can continue to generate electricity.
- Fuse amp evalyasyon ≥ 1.25 x Isc
- Chwazi pwochen pi wo evalyasyon estanda nan katalòg la nan Fusibles PV ki disponib.
- Isc = Kout-sikwi aktyèl yon modil nan kondisyon tès estanda (STC).
- Lè nou konsidere valè Isc nan modil SoliTek, bon valè PV Fuses yo dwe itilize nan enstalasyon an se 30 A. SoliTek rekòmande pou itilize PV fusibles nan kondiktè pozitif ak negatif.
KAB & FIL
Modil SoliTek PV yo bay de kab pwodiksyon estanda, ki reziste limyè solèy la ki fini ak konektè PV pare pou pifò enstalasyon yo. Pozitif (+) tèminal la gen yon konektè gason pandan y ap tèminal negatif (-) la gen yon konektè fi. Fil elektrik modil la fèt pou koneksyon seri (sa vle di, gason (+) ak fi (-) entèkoneksyon) men yo ka itilize tou pou konekte aparèy elektrik apwopriye twazyèm pati ki ka gen konfigirasyon fil elektrik altènatif toutotan enstriksyon manifakti a yo swiv.
Sèvi ak fil elektrik jaden ak zòn kwa-seksyonèl apwopriye ki apwouve pou itilize nan aktyèl la maksimòm kout-sikwi nan modil la PV. Tout fil elektrik yo dwe doub izole, câbles kwaze ak yon evalyasyon minimòm de 1,8 kV (plis pase 1500 V vol.tage) ak yon tanperati minimòm nominal 90 ˚C (190 °F). Gwosè fil pa mwens pase 4 mm² (12 AWG). Kalite izolasyon an ta dwe apwopriye pou kalite metòd enstalasyon yo itilize epi li dwe satisfè kondisyon IEC 61730 ak Klas Sekirite II.
- Nivo izolasyon: 1,8 kV (kondiktè-kondiktè).
- Tanperati: -40 °C jiska +90 °C (-40 °F jiska 190 °F) omwen.
- Konstriksyon kondiktè: fèblan fil kwiv bloke ak pite kòb kwiv mete pi gran pase 99,9%.
- Prensipal izolasyon: polyethylene relye (XLPE), limyè solèy la ak imidite rezistan, rezistan flanm dife. Apwopriye pou kanal ak kous enstale anba tè.
- Izolasyon (jakèt): tèrmoplastik, rezistan limyè solèy la, rezistan flanm dife, rezistan dlo.
- Minimòm kab dyamèt ekstèn ak izolasyon - 5,2 mm (2,05 pous).
- Minimòm kondiktè koup transvèsal - 4 mm² (12 AWG).
SoliTek rekòmande pou enstalatè yo itilize sèlman câbles ki reziste limyè solèy la ki kalifye pou fil kouran dirèk (DC) nan sistèm PV. Kab yo ta dwe fikse nan estrikti aliye a nan yon fason pou evite domaj mekanik nan kab la ak / oswa modil la. Pa aplike estrès nan câbles yo. Pou repare, sèvi ak mwayen apwopriye, tankou lyen ki reziste limyè solèy la ak / oswa klip jesyon fil. Pandan ke câbles yo reziste limyè solèy la ak enpèmeyab, kote sa posib, evite ekspoze limyè solèy la dirèk ak imèsyon dlo nan câbles yo.
Longè estanda nan kab ki soti nan bwat junction yo se 1,2 m (47,24 pous). Li gen entansyon ke de panno ta entèkonekte nan sistèm nan.
TÈ
- Module grounding must be done in accordance with the electrical design and construction specifications, procedures, regulations and other special grounding requirements applicable to the installation sites. If grounding is needed, it should be done accordingly:
Framed type modules grounding
Twou ki make ak yon mak baz sou ankadreman an ka itilize sèlman pou baz. Pa fè egzèsis plis twou tè sou ankadreman modil la.
The grounding conductor or strap may be copper, copper alloy, or any other material acceptable foruse as an electrical conductor in accordance with local electric codes and regulations.
Lè sa a, kondiktè tè a dwe fè yon koneksyon sou tè a lè l sèvi avèk yon elektwòd tè apwopriye.
A bolted connection is required; it incorporates:
- Yon gwosè boulon nan M4.
- Yon machin pou lave dan anba tèt boulon an oswa yon boulon krante dwe antre nan kouch ki pa kondiktif tankou ankadreman anodize.
- Yon nwa tache apwopriye pou boulon M4.
- Tout pyès ki nan konpitè yo dwe nan metal ki pa fèr, 300-seri asye pur, oswa apwopriye korozyon-pwoteje.
- Koupl rekòmande pou bloke nwa a se 2 Nm÷2.2 Nm (1,48÷1,62 ft-lb).
- Tè boulon dwe ale nan tout eleman ki konekte yo.

- Aparèy ki nan lis ak idantifye pou mete atè ankadreman metalik modil PV yo gen pèmisyon pou mete ankadreman metal ki ekspoze nan modil la nan estrikti aliye ki baze sou tè.
- In any case the grounding screws or other parts have to be used separately from the mounting parts of the module.
- Alternate grounding options built through the mounting system are acceptable as long as they have been IEC and UL approved.
- Grounding resistance of the grounding structure shall be reached according to local regulations, Eurocodes, or other legal normative references.
Frameless type modules grounding
- Due to that modules are without frame, grounding is not forseen. Other PV plant equipment should be grounded according to the local and national electrical codes.
KONEKTÈ
- Connectors for SoliTek PV panels are Stäubli MC4-Evo 2. Keep connectors dry and clean and ensure that connector caps are hand-tight before connecting the modules.
- Pa eseye fè yon koneksyon elektrik ak konektè mouye, sal, oswa otreman defo.
- Evite ekspoze konektè yo nan limyè solèy la epi evite mete yo nan dlo. Evite konektè yo rete atè oswa sou sifas twati a.
- Do not disconnect under load. Faulty connections can result in arcs and electrical shock.
- Tcheke ke tout koneksyon elektrik yo byen tache. Asire w ke tout konektè bloke yo konplètman angaje ak fèmen.
DIOD BYPASS
The PV module’s junction box contains 3 bypass diodes (one in each part of split junction box; Schottky type) connected in parallel with the PV cell strings. In the case of partial shading (hot-spot effect), the diodes bypass the current generated by the non-shaded cells, therebylimiting module heating and performance losses.
Dyòd bypass yo pa aparèy pwoteksyon surkouran. Dyodes Bypass devye kouran soti nan strings selil yo nan evènman an nan lonbraj pasyèl. Karakteristik dyod sa yo:
- VoltagEvalyasyon - 50 V.
- Evalyasyon aktyèl - 25 A.
KLAS KLAS DIFE
- SoliTek SOLID Bifacial ak Blackstar modil yo te apwouve pa tès dife IEC ak reyalize Klas Enflamabilite A. Yo te fè tès dife nan enklinasyon 127 mm (5 pous) pou chak 300 mm (11,81 pous), jan sa preskri nan pwen A.2.5 nan IEC 61730-2.
- SoliTek SOLID Bifacial has fire rating of 28 according to UL1703-2 standard. SoliTek Blackstar has fire rating of 29 according to UL1703-2 standard.
Mekanik aliye
- The mechanical loads described in this manual are the test loads.
- For calculating the equivalent maximum design loads, a safety factor of 1.5 (Design load×1.5 safety factor=Mechanical test load) needs to be considered in compliance with the requirements of the local laws and regulations.
KONDISYON JENERAL
- Modules can be mounted in landscape or portrait orientation. For the bifacial modules, in order to get notable bifacial gain, the distance between the bottom of the modules and the roof or ground surface shall be at least 0,8 m (31,50 inch).
- Also, the bifacial gain increases significantly if modules are installed above white, light-reflecting surfaces (under surfaces with high albedo value).
- If the mounting rails are installed across the module, the bifaciality effect will be lower due to back-side cells shading.
- Tanpri obsève règleman sekirite yo ak enstriksyon enstalasyon ki enkli ak sistèm aliye a. Si sa nesesè, tanpri kontakte founisè a dirèkteman pou plis enfòmasyon.
- The modules must be safely set onto the mounting rail.
- The whole rail supporting the photovoltaic system must be strong enough to resist potential mechanical pressures caused either by wind or snow, in accordance with local, regional and state safety (and other associated) standards.
- The mounting system shall be tested and inspected by a third-party testing institution with static mechanical analysis capacity in accordance with local national standards or international standards.
- Before installing modules on a roof, ensure that the roof construction is suitable.
- In addition, any roof penetration required to mount the modules must be properly sealed to prevent leaks.
- Asire w ke tren an aliye pa pral defòme oswa afekte modil yo lè li elaji kòm yon rezilta nan ekspansyon tèmik.
- The module can appear thermal expansion and cold contraction; thus, the interval between two adjoining modules shall be no lesser than 10 mm (0,39 inch).
- Pa eseye fè twou nan sifas vè a ak ankadreman yo nan modil yo paske sa a pral anile garanti a.
- The mounting method must not result in the direct contact of dissimilar metals with the aluminum frame of the modules that will result in galvanic corrosion.
Konpozan yo aliye yo dwe fèt ak materyèl dirab, anti-korozif ak UV ki reziste (konpozan asye pur ak anodize aliminyòm yo rekòmande).
MONTE AK CLAMPS
- Sèvi ak omwen 4 Plastifye clamps ranje modil sou ray yo aliye. Modil clampPati metal yo pa ta dwe antre an kontak ak vè devan oswa dèyè. Lè w ap chwazi sa a kalite clamp-metòd aliye, sèvi ak omwen kat clamps sou chak modil; de clampyo ta dwe tache sou chak bò long. Tou depan de chaj van ak nèj lokal yo, plis clamps ka mande pou asire ke modules ka pote chay la.
- Clamps sere koupl ta dwe omwen 15 Nm (11,06 ft-lb), men pa pi gran pase 20 Nm (14,75 ft-lb). Anjeneral, 15 Nm (11,06 ft-lb), yo rive jwenn lè de aliminyòm pro.fileyo manyen youn ak lòt. Lè yon modil enstale nan oryantasyon pòtrè sou do kay la ki gen > 45 ° pant, yo mande yon zen adisyonèl nan pati anba a nan modil la.

SOLID Black, Semi-clear, Satin, Agro Frameless
Avèk ray transversal


BLACKSTAR, SOLID Black 35(40) mm, SOLID Semi-clear 35(40) mm, SOLID Satin 35(40) mm, SOLID Agro 35(40) mm, Magnus Framed mounting
- Lè w ap chwazi sa a kalite clamp-metòd aliye, sèvi ak omwen kat clamps sou chak modil; de clampyo ta dwe tache sou chak bò nan modil la. Modil clamps pa ta dwe antre an kontak ak vè devan an epi yo pa dwe defòme ankadreman an.
- Asire w ke w evite efè lonbraj sou selil solè ki soti nan modil cl laamps.
- The module frame is not to be modified under any circumstances. Do not to block the drain hole of the frame.
- Longè clamp should be at least 30 mm (1,18 inch).
- Cl laamp dwe sipèpoze ankadreman modil la pa omwen 5 mm (0,2 pous), men pa plis pase 10mm (0,4 pous).
Avèk ray transversal

San yo pa ray transversal oswa ray yo pèpandikilè ak ankadreman an bò long

Avèk sistèm ensèsyon

Monte ak boulon
- Modil la dwe tache ak sipòte pa kat boulon asye pur M8 nan twou ki endike yo aliye sou ba yo transversal. Koupl sou cl laamp bolt has to be in range of 8÷10 Nm (5,9÷7,38 ft-lb). The transversal bars positioning is shown in Figure 3.
- If additional mounting points are required, depending on the local wind and snow loads, then a mounting solution with clamping pyès ki nan konpitè yo dwe chwazi.

- Mounting with bolts can be done only through dedicated predrilled holes in the frame.
- Perçage nouvo twou entèdi epi li pral anile garanti a.

POZISYON Bwat junction a
- Pou distans ki genyen ant bwat junction ak kwen nan modil la oswa lòt dimansyon nan pozisyon bwat junction ak zòn tanpri gade nan figi yo montre anba a.

Antretyen
- Pou asire pèfòmans modil pi gwo, SoliTek rekòmande sa ki annapre yo:
- Si sa nesesè, devan an vè modil la ka netwaye ak dlo ak yon eponj mou oswa twal.
- Yo ka itilize yon detèjan ki pa grav, ki pa abrazif pou retire tach ki gen plis tèt di.
- Tcheke koneksyon elektrik ak mekanik detanzantan epi asire w yo pwòp, an sekirite, konplè epi an sekirite.
- Si ta gen yon pwoblèm, konsilte ak yon moun ki gen lisans/kalifye.
SPECIFICATIONS
| Paramèt \ Modèl | BLACKSTAR B.96 | SOLID Black (Semi-Clear) B.96 35(40) mm | BLACKSTAR Satin B.96 | MAGNUS B.108 |
| Kondisyon tès yo | STC | STC | STC | STC |
| Nominal pouvwa | 455 W | 455 W | 445 W | 510 W |
| Done elektrik @STC | ||||
| Maksimòm pouvwa (Pmax), W | 455 | 455 | 445 | 510 |
| Voltage nan maksimòm pouvwa (Vmpp), V | 29,71 | 29,71 | 29,40 | 33,34 |
| Kouran nan pouvwa maksimòm (Impp), A | 15,31 | 15,31 | 15,14 | 15,30 |
| Louvri Awondisman Voltage (Voc), V | 34,82 | 34,82 | 34,40 | 39,06 |
| Kout sikwi Kouran (Isc), A | 15,97 | 15,97 | 15,79 | 15,95 |
| Done tèmik | ||||
| Fonksyone Tanperati Range | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) |
| Koefisyan Tanperati nan Pmax | -0,362%/°C (°F) | -0,362%/°C (°F) | -0,362%/°C (°F) | -0,362%/°C (°F) |
| Koefisyan Tanperati Voc | -0,265%/°C (°F) | -0,265%/°C (°F) | -0,265%/°C (°F) | -0,265%/°C (°F) |
| Koefisyan Tanperati Isc | +0,036% /° C (°F) | +0,036% /° C (°F) | +0,036% /° C (°F) | +0,036% /° C (°F) |
| Done gwosè ak pwa | ||||
| Longè | 1762 mm | 1762 mm | 1762 mm | 1961 mm |
| Lajè | 1134 mm | 1134 mm | 1134 mm | 1134 mm |
| Epesè | 30 mm | 35(40) mm | 30mm | 30 mm |
| Pwa | 25,5 kg | 35 (36) kg | 25,5 kg | 28,5 kg |
| Metòd monte | ||||
| Reference to the chapter | 3.3 | 3.3 | 3.3 | 3.3 |
| Lòt | ||||
| Maksimòm aktyèl ranvèse, A | 30 | |||
| Fire class, IEC 61730/UL 61730 | A/Tip II | |||
| Sistèm maksimòm voltage, V | 1500 | |||
Table 9. Electrical and mechanical parameters table.
| Paramèt \ Modèl | SOLID Semi- clear B.96 | SOLID Black B.96 | SOLID Satin B.96 | SOLID Agro B.64 |
| Kondisyon tès yo | STC | STC | STC | STC |
| Nominal pouvwa | 455 W | 455 W | 445 W | 300 W |
| Done elektrik @STC | ||||
| Maksimòm pouvwa (Pmax), W | 455 | 455 | 445 | 300 |
| Voltage nan maksimòm pouvwa (Vmpp), V | 29,71 | 29,71 | 29,40 | 19,60 |
| Kouran nan pouvwa maksimòm (Impp), A | 15,31 | 15,31 | 15,14 | 15,31 |
| Louvri Awondisman Voltage (Voc), V | 34,82 | 34,82 | 34,40 | 22,76 |
| Kout sikwi Kouran (Isc), A | 15,97 | 15,97 | 15,79 | 15,97 |
| Done tèmik | ||||
| Fonksyone Tanperati Range | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) |
| Koefisyan Tanperati nan Pmax | -0,30%/°C (°F) | -0,30%/°C (°F) | -0,30%/°C (°F) | -0,30%/°C (°F) |
| Koefisyan Tanperati Voc | -0,25%/°C (°F) | -0,25%/°C (°F) | -0,25%/°C (°F) | -0,25%/°C (°F) |
| Koefisyan Tanperati Isc | +0,045% /° C (°F) | +0,045% /° C (°F) | +0,045% /° C (°F) | +0,045% /° C (°F) |
| Done gwosè ak pwa | ||||
| Longè | 1772 ± 2 mm | 1772 ± 2 mm | 1772 ± 2 mm | 1772 ± 2 mm |
| Lajè | 1144±2 | 1144±2 | 1144 ± 2 mm | 1144 ± 2 mm |
| Epesè | 7,2 mm | 7,2 mm | 7,2 mm | 7,2 mm |
| Pwa | 33kg | 33 kg | 33 kg | 33 kg |
| Metòd monte | ||||
| Reference to the chapter | 3.2 | 3.2 | 3.2 | 3.2 |
| Lòt | ||||
| Maksimòm aktyèl ranvèse, A | 30 | |||
| Fire class, IEC 61730/UL 61730 | A/Tip II | |||
| Sistèm maksimòm voltage, V | 1500 | |||
Table 10. Electrical and mechanical parameters table.
| Paramèt \ Modèl | SOLID Satin B.96 35 mm | SOLID Satin B. 96 40 mm | SOLID AgroB.64 35 mm | SOLID AgroB.64 40 mm |
| Kondisyon tès yo | STC | STC | STC | STC |
| Nominal pouvwa | 445 W | 445 W | 300 W | 300 W |
| Done elektrik @STC | ||||
| Maksimòm pouvwa (Pmax), W | 445 | 445 | 300 | 300 |
| Voltage nan maksimòm pouvwa (Vmpp), V | 29,40 | 29,40 | 19,60 | 19,60 |
| Kouran nan pouvwa maksimòm (Impp), A | 15,14 | 15,14 | 15,31 | 15,31 |
| Louvri Awondisman Voltage (Voc), V | 34,40 | 34,40 | 22,78 | 22,78 |
| Kout sikwi Kouran (Isc), A | 15,79 | 15,79 | 15,97 | 15,97 |
| Done tèmik | ||||
| Fonksyone Tanperati Range | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) | -40oC ÷ 85oC (-40°F ÷ 185°F) |
| Koefisyan Tanperati nan Pmax | -0,362%/°C (°F) | -0,362%/°C (°F) | -0,30%/°C (°F) | -0,30%/°C (°F) |
| Koefisyan Tanperati Voc | -0,265%/°C (°F) | -0,265%/°C (°F) | -0,25%/°C (°F) | -0,25%/°C (°F) |
| Koefisyan Tanperati Isc | +0,036% /° C (°F) | +0,036% /° C (°F) | +0,045% /° C (°F) | +0,045% /° C (°F) |
| Done gwosè ak pwa | ||||
| Longè | 1762mm | 1762mm | 1762 mm | 1762 mm |
| Lajè | 1134 mm | 1134 mm | 1134 mm | 1134 mm |
| Epesè | 35 mm | 40 mm | 35 mm | 40 mm |
| Pwa | 35 kg | 36kg | 35 kg | 36 kg |
| Metòd monte | ||||
| Reference to the chapter | 3.3 | |||
| Lòt | ||||
| Maksimòm aktyèl ranvèse, A | 30 | |||
| Fire class, IEC 61730/UL 61730 | A/Tip II | |||
| Sistèm maksimòm voltage, V | 1500 | |||
Table 11.Electrical and mechanical parameters table.
- The electrical characteristics are within of the indicated values of ISC (φISC) ±3%, VOC (ϕVOC) ±3,5% and PMPP (ϕPmax) ±5%, under Standard Test Conditions (STC) (irradiance of 1000 W/m²,AM 1.5 spectrum, and a cell temperature of 25°C / 77°F)
- Tout panno SoliTek SOLID PV koresponn ak klas sekirite elektrik II.
Limit responsabilite nou
- Depi li enposib pou SoliTek kontwole enstalasyon, operasyon, aplikasyon ak antretyen nan sistèm fotovoltaik la dapre enstriksyon sa a. SoliTek pa aksepte responsablite epi li ekspreseman li renonse responsablite pou nenpòt pèt, domaj oswa depans ki soti nan oswa nan nenpòt fason ki konekte ak enstalasyon, operasyon, itilizasyon oswa antretyen.
- SoliTek will not take any responsibility for any possible violation of patent rights and third-party rights that are related to the application of the solar energy system. No permission of patents is given through implication.
- The information of this instruction is from the knowledge and experiences of SoliTek. However, the instructions and suggestions of this instruction do not make an external or internal of guarantee. SoliTek reserves the right to revise this instruction, products and all the information about products without prior notification to customers.
FAQ
- Q: What should I do before installing the PV modules?
- A: Read this entire guide, understand all instructions, and ensure compliance with all local, state, and federal regulations. Consult a certified building specialist for the structural integrity of the dwelling.
- Q: Can I install the PV modules myself without professional training?
- A: This documentation is not a complete installation manual for personnel not specifically trained in PV-modules. It serves as a general but strictly mandatory reference for the installer. Professional installation is highly recommended.
- Q: What happens if I don’t follow the instructions in this guide?
- A: Failure to follow instructions may damage system components, endanger personnel, damage property, or invalidate the panel warranty.
- Q: Is it safe to work on a rooftop during installation?
- A: Do not attempt to work on a rooftop until safety precautions have been identified and taken, including fall protection measures, ladders or stairways, and personal protective equipment (PPE). Avoid adverse conditions like strong winds or wet/frosted roofs.
- Q: How should I store the PV modules before installation?
- A: Store pallets in a cool and dry location until the PV modules are ready to be unpackaged. Do not exceed the maximum stacking height indicated on the packaging.
Dokiman / Resous
![]() | SOLID Series Solar Modules |
Referans
- solitek.euwww.solitek.eu
- Manyèl itilizatèmanual.tools