Omada L3 Campus Stackable Managed Switch User Manual

Omada L3 Campus Stackable Managed Switch

L3 Campus Stackable Managed Switch

Espesifikasyon

  • Modèl: Omada Campus Stackable L3 Managed Switch
  • Front Panel: Mode Selection Button, Management Port, LED,
    Console Port USB2.0 Port (Type-C/RJ45), 1G RJ45 Port, 10G SFP+ Slot
    dirije
  • Endikasyon ki ap dirije:
    • PWR1*: Green On (switch powered by PWR1), Off (PWR2
      disconnected or not working properly)
    • PWR2: Green On (switch powered by PWR1 and PWR2 connected),
      Yellow On** (PWR2 powered), Off (PWR1 disconnected or not working
      byen)
    • LED SYS FAN: Green On (all fans work properly), Yellow On (not
      all fans work properly)
    • MGMT: On (device linked to port), Flashing (transmitting or
      receiving data), Off (no device linked to port)
    • MST: On (device linked to port), Flashing (transmitting or
      receiving data), Off (no device linked to port)

Enstriksyon Itilizasyon Pwodwi

Chapit 2: Enstalasyon

Anvan ou kòmanse pwosesis enstalasyon an, asire w ke ou gen tout
the necessary tools and follow safety precautions.

  • Kontni pake: Check all items mentioned in
    pake a.
  • Prekosyon sekirite: Follow the guidelines to
    asire enstalasyon an sekirite.
  • Zouti enstalasyon: Gather all tools required
    pou enstalasyon.
  • Enstalasyon pwodwi: Swiv etap pa etap la
    instructions provided in the manual for successful
    enstalasyon.

Chapit 3: Koneksyon

After installation, connect the switch to the network using
appropriate cables and ports as per your network setup.

Chapit 4: Konfigirasyon

Configure the switch based on your requirements. You can choose
between Standalone Mode or Controller Mode as per your network
bezwen.

FAQ

Q: What should I do if the LED indications show an error?

A: If the LED indications suggest improper functioning, check
the power sources and connections. Refer to the troubleshooting
seksyon nan manyèl la pou plis asistans.

Loading PDF…
Download PDF

Solisyon rezo biznis
Gid enstalasyon
Omada Campus Stackable L3 Managed Switch

Konsènan Gid Enstalasyon sa a
Gid Enstalasyon sa a dekri karakteristik pyès ki nan konpitè, metòd enstalasyon ak pwen yo ta dwe okipe pandan enstalasyon an. Gid Enstalasyon sa a estriktire jan sa a: Chapit 1 Entwodiksyon Chapit sa a dekri eleman ekstèn switch la. Chapit 2 Enstalasyon Chapit sa a montre kijan pou enstale switch la. Chapit 3 Koneksyon Chapit sa a montre kijan pou fè koneksyon fizik switch la. Chapit 4 Konfigirasyon Chapit sa a montre kijan pou konfigirasyon switch la. Apendis A Depanaj Apendis B Espesifikasyon

Odyans lan

Gid Enstalasyon sa a se pou:

Enjenyè rezo

Administratè Rezo

Konvansyon
· Gen kèk modèl ki nan gid sa a ki ka pa disponib nan peyi w oswa rejyon w lan. Pou enfòmasyon sou lavant lokal yo, vizite https://www.omadanetworks.com/.
· Chif ki nan Chapit 2, Chapit 3, ak Chapit 4 yo se pou rezon demonstrasyon sèlman. Chanjman ou a ka diferan nan aparans ak sa ki dekri.
· Kalkil bidjè PoE yo baze sou tès laboratwa. Aktyèl bidjè pouvwa PoE pa garanti epi yo pral varye kòm rezilta limit kliyan ak faktè anviwònman an.
· Gid sa a sèvi ak fòma espesifik yo pou mete aksan sou mesaj espesyal. Tablo ki anba la a bay lis ikon avi yo itilize nan tout gid sa a.

Raple fè atansyon. Yon prekosyon endike yon potansyèl ki ka lakòz domaj nan aparèy la.
Raple pran avi. Nòt la gen enfòmasyon ki itil pou yon pi bon itilizasyon pwodwi a.

Dokiman ki gen rapò
Gid pou Itilizatè ak Gid Referans CLI nan pwodwi yo bay sou Sant Download. Pou jwenn dènye enfòmasyon sou pwodwi, vizite ofisyèl la websit: https://support.omadanetworks.com/document/.

Kontni
Chapit 1 Entwodiksyon ———————- 01
1.1 Pwodwi souview …………………………………………………………..01 1.2 Aparans………………………………………………………………………..01
Chapit 2 Enstalasyon ———————- 12
2.1 Sa ki pakè a ……………………………………………….12 2.2 Prekosyon sekirite ……………………………………………………………12 2.3 Zouti enstalasyon……………………………………………………..14 2.4 Enstalasyon pwodwi ………………………………………………..14
Chapit 3 Koneksyon ———————- 22
3.1 Ethernet Port …………………………………………………………..22 3.2 10G SFP+/25G SFP28/100G QSFP28 Slot ………..22 3.3 Console Port ……………………………………………………………22 3.4 Verify Installation…………………………………………………….23 3.5 Power On ………………………………………………………………….24 3.6 Initialization………………………………………………………………24 3.7 Stack Topology ……………………………………………………….24
Chapit 4 Konfigirasyon ——————– 27
4.1 Konfigirasyon finiview………………………………………… 27 4.2 Mòd Otonòm…………………………………………………… 27 4.3 Mòd Kontwolè…………………………………………………… 28
Anèks A Depanaj —————- 32
Apendis B Espesifikasyon —————— 33

Omada Campus Stackable L3 Managed Switch

Chapit 1 Entwodiksyon

1.1 Pwodwi souview
Fèt pou antrepriz ak campus, Omada Campus Stackable L3 Managed Switch provides wire-speed performance and abundant L2 and L3 management features. It provides a variety of service features and multiple powerful functions with high security. The EIA-standardized framework and smart configuration capacity can provide flexible solutions for a variable scale of networks. Static Routing, RIP, OSPF, BGP, IS-IS, PIM-SM/DM/SSM, and ECMP come with abundant Layer 3 routing protocols that support a scalable network. Physically stacking for builtin redundancy and performance. Redundant power supplies and fans make it an ideal choice for reliable networking architecture. VRRP allows a group of switches to dynamically back up each other. ERPS supports rapid protection and recovery in a ring topology. MACsec, secure boot, ACL, 802.1x and Dynamic ARP Inspection provide robust security strategies. QoS and IGMP snooping/filtering optimize voice and video application. Link aggregation (LACP) increases aggregated bandwidth, optimizing the transport of business critical data. SNMP, RMON, WEB, Netconf and CLI Log-in bring abundant management policies. These switches integrate multiple functions with excellent performance, and is friendly to manage, which can fully meet the need of the users demanding higher networking performance. S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is also a Power Sourcing Equipment (PSE*). The RJ45 ports that support Power over Ethernet (PoE*) function can automatically detect and supply power to those powered devices (PDs*) complying with IEEE 802.3af, IEEE 802.3at, and IEEE 802.3bt (only for S6500-24MPP4Y/S6500-48MPP6Y). *PSE: a device (switch or hub for instance) that provides power through an Ethernet cable. *PoE: This technology describes a system to transmit electrical power, along with data, to remote devices over standard twisted-pair cable in an Ethernet. *PD: a device powered by a PSE and thus consumes energy. Examples gen ladan kamera rezo alimante, pwen aksè LAN san fil, telefòn IP, sant rezo, òdinatè entegre elatriye.
1.2 Aparans
Front Panel (The figure is for demonstration only. It may differ from your actual product. )
The front panel of S6500-24G4XF is shown as the following figure.
Bouton Seleksyon Mode
Jesyon Port

dirije

Console Port USB2.0 Port (Type-C/RJ45)

1G RJ45 Port

10G SFP+ Slot LED

The front panel of S6500-48G6XF is shown as the following figure.
Bouton Seleksyon Mode
Jesyon Port

dirije

Console Port USB2.0 Port (Type-C/RJ45)

1G RJ45 Port

10G SFP+ Slot LED

Entwodiksyon 01

Omada Campus Stackable L3 Managed Switch

Endikasyon ki ap dirije

PWR1*

PWR2

Vèt Sou

Off

Vèt Sou

Jòn limen**

Off

Vèt Sou

Off

Off

Endikasyon
Se switch la ki mache ak PWR1. PWR2 dekonekte oswa li travay mal.
Se switch la ki mache ak PWR1. PWR1 ak PWR2 konekte.*
Se switch la ki mache ak PWR2. PWR1 dekonekte oswa li travay mal.
Chanjman an koupe oswa tou de PWR1 ak PWR2 travay mal.

LED SYS FAN
MGMT
MST
Port 1-24 of S6500-24G4XF/ Port 1-48 of S6500-48G6XF
(When the SPEED LED is on)
Port 1-24 of S6500-24G4XF/ Port 1-48 of S6500-48G6XF
(Lè LED STK limen)
Port 25-28 of S6500-24G4XF/ Port 49-54 of S6500-48G6XF ***

Endikasyon
Flache: switch la ap travay byen. On oswa Off: switch la travay mal.
Green On: Tout fanatik yo travay byen. Jòn limen: Se pa tout fanatik yo ap travay byen.
Limen: Gen yon aparèy ki konekte ak pò a. Limyè k ap flache: Ap transmèt oswa ap resevwa done. Etenn: Pa gen okenn aparèy ki konekte ak pò a.
Limen: Aparèy la fonksyone kòm switch prensipal la nan topoloji pil la oubyen li fonksyone poukont li. Etenn: Aparèy la fonksyone kòm switch manm nan topoloji pil la.
Green On: Kouri nan 1000 Mbps, men pa gen aktivite. Green Flashing: Kouri nan 1000 Mbps epi transmèt oswa resevwa done. Jòn sou: Kouri nan 10Mbps/100 Mbps, men pa gen aktivite. Flache jòn: Kouri nan 10Mbps/100 Mbps epi transmèt oswa resevwa done. Off: Pa gen okenn aparèy ki lye ak pò ki koresponn lan.
On: Nimewo pò a endike ID inite a nan topoloji pil la.
Green On: Kouri nan 10 Gbps, men pa gen aktivite. Green Flashing: Kouri nan 10 Gbps epi transmèt oswa resevwa done. Jòn Limen: Kouri a 1 Gbps, men pa gen aktivite. Flache jòn: Kouri nan 1 Gbps epi transmèt oswa resevwa done. Off: Pa gen okenn aparèy ki lye ak pò ki koresponn lan.

*PWR1 is the primary power supply and it takes priority over PWR2. When the device is powered by PWR1, PWR2 will be working in the backup mode.
**Lè tou de PWR1 ak PWR2 travay byen epi switch la mache ak PWR1, li pran 10-20 segonn pou LED PWR2 (jòn) soti apre PWR2 deploge.
***All 10 Gbps SFP+ slots can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.

02 Entwodiksyon

Omada Campus Stackable L3 Managed Switch The front panel of S6500-24GP4XF is shown as the following figure.

Bouton Seleksyon Mode
Jesyon Port
LED Console Port USB2.0 Port (Type-C/RJ45)

1G RJ45 Port

10G SFP+ Slot LED

Panèl devan S6500-48GP6XF montre kòm figi sa a.

Bouton Seleksyon Mode
Jesyon Port
LED Console Port USB2.0 Port (Type-C/RJ45)

1G RJ45 Port

10G SFP+ Slot LED

The front panel of S6500-24M4Y is shown as the following figure.

Bouton Seleksyon Mode
Jesyon Port
LED Console Port USB2.0 Port (Type-C/RJ45)

2.5G RJ45 Port

25G SFP28 Slot LED

The front panel of S6500-24MPP4Y is shown as the following figure.

Bouton Seleksyon Mode
Jesyon Port
LED Console Port USB2.0 Port (Type-C/RJ45)

2.5G RJ45 Port

25G SFP28 Slot LED

Entwodiksyon 03

Omada Campus Stackable L3 Managed Switch The front panel of S6500-48M6Y is shown as the following figure.

Bouton Seleksyon Mode
Jesyon Port

LED Console Port USB2.0 Port (Type-C/RJ45)

2.5G RJ45 Port

The front panel of S6500-48MPP6Y is shown as the following figure.

25G SFP28 Slot LED

Bouton Seleksyon Mode
Jesyon Port
LED Console Port USB2.0 Port (Type-C/RJ45)

2.5G RJ45 Port

25G SFP28 Slot LED

LED Indication LED
PWR1* PWR2
SYS FAN PoE MAX
(For S6500-24GP4XF, S6500-48GP6XF, S6500-24MPP4Y, S6500-48MPP6Y)
MGMT
MST

Endikasyon
Green On: The power supply works properly. Green Flashing: The power supply module is not plugged in properly or not compatible with the switch. Yellow On: The power supply works properly but the switch is powered by the other power supply.** Yellow Flashing: The power supply module is plugged in properly but there’s is no AC power input; abnormal power supply. Off: No power supply module is inserted.
Flache: switch la ap travay byen. On oswa Off: switch la travay mal.
Green On: Tout fanatik yo travay byen. Jòn limen: Se pa tout fanatik yo ap travay byen.
Limen: Pouvwa PoE ki rete a se 7 W. Kliyan: Pouvwa PoE ki rete a kenbe 7 W apre LED sa a limen pou 2 minit. Off: rès pouvwa PoE a se > 7 W.
Limen: Gen yon aparèy ki konekte ak pò a. Limyè k ap flache: Ap transmèt oswa ap resevwa done. Etenn: Pa gen okenn aparèy ki konekte ak pò a.
Limen: Aparèy la fonksyone kòm switch prensipal la nan topoloji pil la oubyen li fonksyone poukont li. Etenn: Aparèy la fonksyone kòm switch manm nan topoloji pil la.

04 Entwodiksyon

Omada Campus Stackable L3 Managed Switch

dirije

Endikasyon

Port 1-24 of S6500-24GP4XF/
Port 1-48 of S6500-48GP6XF
(When the SPEED LED is on)

Green On: Kouri nan 1000 Mbps, men pa gen aktivite. Green Flashing: Kouri nan 1000 Mbps epi transmèt oswa resevwa done. Jòn sou: Kouri nan 10Mbps/100 Mbps, men pa gen aktivite. Flache jòn: Kouri nan 10Mbps/100 Mbps epi transmèt oswa resevwa done. Off: Pa gen okenn aparèy ki lye ak pò ki koresponn lan.

Port 1-24 of S6500-24M4Y & S6500-24MPP4Y/
Port 1-48 of S6500-48M6Y & S6500-48MPP6Y
(When the SPEED LED is on)

Green On: Running at 2.5 Gbps, but no activity. Green Flashing: Running at 2.5 Gbps and transmitting or receiving data. Yellow On: Running at 10 Mbps/100 Mbps/1000 Mbps, but no activity. Yellow Flashing: Running at 10 Mbps/100 Mbps/1000 Mbps and transmitting or receiving data. Off: No device is linked to the corresponding port.

Port 1-24 of S6500-24GP4XF, S6500-24M4Y &
S6500-24MPP4Y/
Port 1-48 of S6500-48GP6XF, S6500-48M6Y &
S6500-48MPP6Y
(Lè LED STK limen)

On: Nimewo pò a endike ID inite a nan topoloji pil la.

Port 1-24 of S6500-24GP4XF & S6500-24MPP4Y/
Port 1-48 of S6500-48GP6XF & S6500-48MPP6Y
(Lè LED PoE a limen)

Green On: The port is supplying power normally. Green Flashing: The supply power exceeds the correponding port’s maximum power. Yellow On: Overload or short circuit is detected. Off: Not providing PoE power on the port

Port 25-28 of S6500-24GP4XF/ Port 49-54 of S6500-48GP6XF ***

Green On: Kouri nan 10 Gbps, men pa gen aktivite. Green Flashing: Kouri nan 10 Gbps epi transmèt oswa resevwa done. Jòn Limen: Kouri a 1 Gbps, men pa gen aktivite. Flache jòn: Kouri nan 1 Gbps epi transmèt oswa resevwa done. Off: Pa gen okenn aparèy ki lye ak pò ki koresponn lan.

Port 25-28 of S6500-24M4Y & S6500-24MPP4Y/
Port 49-54 of S6500-48M6Y & S6500-48MPP6Y***

Vèt Limen: Ap fonksyone a 25 Gbps, men pa gen aktivite. Vèt Klike: Ap fonksyone a 25 Gbps epi ap transmèt oswa ap resevwa done. Jòn Limen: Ap fonksyone a 1 Gbps/10 Gbps, men pa gen aktivite. Jòn Klike: Ap fonksyone a 1 Gbps/10 Gbps epi ap transmèt oswa ap resevwa done. Etenn: Pa gen okenn aparèy ki konekte ak pò ki koresponn lan.

*By default, S6500-24GP4XF is shipped with a PSM500-AC power supply module, S6500-24M4Y/S650048M6Y is shipped with a PSM550-AC power supply module, and S6500-48GP6XF/S6500-24MPP4Y/ S6500-48MPP6Y is shipped with a PSM900-AC power supply module. One more power supply module needs to be purchased separately.
**By default, both PWR1 and PWR2 will work simultaneously in the load sharing mode. They can also work simultaneously in the redundant power supply mode: for S6500-24GP4XF/S6500-48GP6XF/S650024MPP4Y/S6500-48MPP6Y, you can specify the primary power supply and the backup power supply according to your needs; for S6500-24M4Y/S6500-48M6Y, you can only set PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
***All 10 Gbps SFP+ slots and 25 Gbps SFP28 slots can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.

Entwodiksyon 05

Omada Campus Stackable L3 Managed Switch The front panel of S7500-26XF6Y is shown as the following figure.
Jesyon Port

dirije

Console Port USB3.0 Port

(RJ45/Kalite-C)

Seleksyon mòd

Bouton

10G SFP+ Slot (Port 1-26)

The front panel of S7500-48XF4C is shown as the following figure.

LED 25G SFP28 Slot (Port 27-32)

Bouton Seleksyon Mode
Jesyon Port
LED Console Port USB3.0 Port (Type-C/RJ45)

10G SFP+ Slot (Port 1-48)

The front panel of S7500-24Y4C is shown as the following figure.

100G QSFP28 Slot LED (Port 49-52)

Jesyon Port

dirije

USB3.0 Port

Pò konsole

(RJ45/Kalite-C)

Bouton Seleksyon Mode

Plas 25G SFP28

dirije

(Pò 1-24)

The front panel of S7500-48Y8C is shown as the following figure.

Plas 100G QSFP28 (Pò 25-28)

LED Mode Selection Button

25G SFP28 Slot (Port 1-48)

06 Entwodiksyon

Plas 100G QSFP28 (Pò 49-56)

Omada Campus Stackable L3 Managed Switch The front panel of S7500-32C is shown as the following figure.

Bouton Seleksyon Mode
Jesyon Port ki ap dirije
USB3.0 Port

Console Port (Type-C/RJ45)

Plas 100G QSFP28

dirije

Note: S7500-24Y4C and S7500-48Y8C are designed for installation in Network Telecommunications Facilities (NTFs) where ambient temperature and humidity are controlled.

LED Indication LED
PWR1* PWR2
SYS FAN
MGMT
MST
Port 1-26 of S7500-26XF6Y/ Port 1-48 of S7500-48XF4C
(Lè SPD ki ap dirije a limen)
Port 1-24 of S7500-24Y4C/ Port 1-48 of S7500-48Y8C
(When the SPD/SPEED LED is on)

Endikasyon
Green On: The power supply works properly. Green Flashing: The power supply module is not plugged in properly or not compatible with the switch. Yellow On: The power supply works properly but the switch is powered by the other power supply.** Yellow Flashing: The power supply module is plugged in properly but there’s is no AC power input; abnormal power supply. Off: No power supply module is inserted.
Flache: switch la ap travay byen. On oswa Off: switch la travay mal.
Green: Tout fanatik yo travay byen. Jòn: Se pa tout fanatik yo travay byen.
Limen: Gen yon aparèy ki konekte ak pò a. Limyè k ap flache: Ap transmèt oswa ap resevwa done. Etenn: Pa gen okenn aparèy ki konekte ak pò a.
Nòt:
For S7500-48Y8C, this LED lights green at 1 Gbps and orange at sub-1 Gbps.
Limen: Aparèy la fonksyone kòm switch prensipal la nan topoloji pil la oubyen li fonksyone poukont li. Etenn: Aparèy la fonksyone kòm switch manm nan topoloji pil la.
Green On: Kouri nan 10 Gbps, men pa gen aktivite. Green Flashing: Kouri nan 10 Gbps epi transmèt oswa resevwa done. Jòn Limen: Kouri a 1 Gbps, men pa gen aktivite. Flache jòn: Kouri nan 1 Gbps epi transmèt oswa resevwa done. Off: Pa gen okenn aparèy ki lye ak pò ki koresponn lan.
Vèt Limen: Ap fonksyone a 25 Gbps, men pa gen aktivite. Vèt Klike: Ap fonksyone a 25 Gbps epi ap transmèt oswa ap resevwa done. Jòn Limen: Ap fonksyone a 1 Gbps/10 Gbps, men pa gen aktivite. Jòn Klike: Ap fonksyone a 1 Gbps/10 Gbps epi ap transmèt oswa ap resevwa done. Etenn: Pa gen okenn aparèy ki konekte ak pò ki koresponn lan.

Entwodiksyon 07

Omada Campus Stackable L3 Managed Switch

dirije

Endikasyon

Port 27-32 of S7500-26XF6Y ***
(Lè SPD ki ap dirije a limen)

Vèt Limen: Ap fonksyone a 25 Gbps, men pa gen aktivite. Vèt Klike: Ap fonksyone a 25 Gbps epi ap transmèt oswa ap resevwa done. Jòn Limen: Ap fonksyone a 1 Gbps/10 Gbps, men pa gen aktivite. Jòn Klike: Ap fonksyone a 1 Gbps/10 Gbps epi ap transmèt oswa ap resevwa done. Etenn: Pa gen okenn aparèy ki konekte ak pò ki koresponn lan.

Port 49-52 of S7500-48XF4C/
Port 25-28 of S7500-24Y4C/ Port 49-56 of S7500-48Y8C/ Port 1-32 of S7500-32C***
(When the SPD/SPEED LED is on)

Green On: Kouri nan 100 Gbps, men pa gen aktivite. Green Flashing: Kouri nan 100 Gbps epi transmèt oswa resevwa done. Jòn Limen: Kouri a 40 Gbps, men pa gen aktivite. Flache jòn: Kouri nan 40 Gbps epi transmèt oswa resevwa done. Off: Pa gen okenn aparèy ki lye ak pò ki koresponn lan.
Nòt:
For S7500-48XF4C/S7500-48Y8C/S7500-32C, the indication above applies only when the 100 Gbps QSFP28 slots work with common cables. When the slots work with 1-to-4 breakout cables, a single slot is split into four 25 Gbps interfaces. In such scenario, the LED will light green only when all four interfaces are working at 25 Gbps (maximum speed), otherwise it will light yellow. When no device is connected to any of the four interfaces, the LED will be off. (The 100 Gbps QSFP28 slots will support 1-to-4 breakout cables in a future software release.)

Port 1-32 of S7500-26XF6Y/
Port 1-48 of S7500-48XF4C/ Port 1-28 of S7500-24Y4C/ Port 1-56 of S7500-48Y8C
(Lè LED STK limen)

On: Nimewo pò a endike ID inite a nan topoloji pil la.

*By default, S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S7500-32C is shipped with a PSM550-AC power supply module installed respectively. One more power supply module needs to be purchased separately. **By default, both PWR1 and PWR2 will work simultaneously in the load sharing mode. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply. ***All 25 Gbps SFP28 slots of S7500-26XF6Y and 100 Gbps QSFP28 slots of S7500-48XF4C/S7500-24Y4C/ S7500-48Y8C/S7500-32C can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.
Port Introduction (The Management Port, Console Ports, and USB Ports of S7500-48Y8C are located on the rear panel.)
Pò Jesyon Ki fèt pou konekte aparèy la pou jesyon atravè web, CLI or SNMP. Do not connect this port to any outdoor device, as this may induce surge and lightning damage. Console Port Designed to connect with a computer for monitoring and configuring the switch. When the switch has an RJ45 console port and a Type-C console port, console input is active on only one console port at a time. By default, the Type-C connector takes priority over the RJ45 connector, or you can change the priority through the web. Do not connect this port to any outdoor device, as this may induce surge and lightning damage. USB Port Designed to install the USB flash disk for data storage. 1000M RJ45 Port Designed to connect to the device with a bandwidth of 10Mbps, 100 Mbps or 1000 Mbps. For PoE switches, the port can also provide power for PDs.

08 Entwodiksyon

Omada Campus Stackable L3 Managed Switch
2.5G RJ45 Port Designed to connect to the device with a bandwidth of 10 Mbps, 100 Mbps, 1000 Mbps or 2.5 Gbps. For PoE switches, the port can also provide power for PDs. 10G SFP+ Slot Designed to install the 10 Gbps/1 Gbps optical module. 25G SFP28 Slot Designed to install the 25 Gbps/10 Gbps/1 Gbps optical module. 100G QSFP28 Slot Designed to install the 100 Gbps/40 Gbps optical module. Port Feature

Modèl

1000M

2.5G 10G SFP+ 25G SFP28 100G QSFP28 Management Console USB

RJ45 Port RJ45 Port Slot

Fant

Fant

Port

Pò Pò

S6500-24G4XF

24

/

4

/

/

S6500-48G6XF

48

/

6

/

/

S6500-24GP4XF

24

/

4

/

/

S6500-48GP6XF

48

/

6

/

/

S6500-24M4Y

/

24

/

4

/

S6500-24MPP4Y

/

24

/

4

/

S6500-48M6Y

/

48

/

6

/

S6500-48MPP6Y

/

48

/

6

/

S7500-26XF6Y

/

/

26

6

/

S7500-48XF4C

/

/

48

/

4

S7500-24Y4C

/

/

/

24

4

S7500-48Y8C

/

/

/

48

8

S7500-32C

/

/

/

/

32

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

Rear Panel (The figure is for demonstration only. It may differ from your actual product. )
The rear panel of S6500-24G4XF/S6500-48G6XF is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.

Kensington Security Slot Grounding Terminal Power Socket

Locking Strap Slot

Remak: PWR1 se ekipman pou pouvwa prensipal la epi li pran priyorite sou PWR2.

Entwodiksyon 09

Omada Campus Stackable L3 Managed Switch
The rear panel of S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.

Plas sekirite Kensington

dirije

Tèminal baz

Power Supply Module

dirije

Locking Strap Slot

Note: By default, S6500-24GP4XF is shipped with a PSM500-AC power supply module, and S650048GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is shipped with a PSM900-AC power supply module. One more power supply module needs to be purchased separately. Both PWR 1 and PWR2 can work simultaneously, or you can specify the primary power supply and the backup power supply according to your needs. Generally, the primary power supply takes priority over the backup power supply.
The rear panel of S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.

Tèminal baz

dirije

Power Supply Module Locking Strap Slot

dirije

Plas sekirite Kensington

Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode: for S6500-24M4Y/S6500-48M6Y, you can only set PWR1 as the primary power supply and PWR2 as the backup power supply; for S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C, you can specify the primary power supply and the backup power supply according to your needs; Generally, the primary power supply takes priority over the backup power supply.

Panèl dèyè S7500-48Y8C a parèt nan figi ki anba a. Figi a se pou rezon demonstrasyon sèlman. Aparans switch ou a ka diferan de sa ki dekri a.

Tèminal baz

dirije

dirije

Bloke senti

Fant

Power Supply Module

10 Entwodiksyon

ManagemeC(nTtoyPnposeor-tCle/RPJoU4rt5S)B3P.o0wPeorrSt upplyLoMcokdiSnulgoletStraLpED

Omada Campus Stackable L3 Managed Switch
Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
The rear panel of S7500-32C is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.

dirije dirije
Locking Strap Slot
Modil Alimantasyon Pouvwa Kensington Sekirite Plas

Tèminal baz

dirije
Locking Strap Slot

Power Supply Module

Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
Power Supply Module The pluggable power supply module PSM500-AC/PSM900-AC/PSM550-AC is an AC-input power supply module. It can convert the input voltage to 53.5 V (12 V for PSM550-AC) with the maximum output power of 500 W/900 W/550 W respectively. Kensington Security Slot Secure the lock (not provided) into the security slot to prevent the device from being stolen.
Grounding Terminal The switch already comes with lightning protection mechanism. You can also ground the switch through the PE (Protecting Earth) cable of AC cord or with Ground Cable. For detailed lightning protection measures, refer to the Lightning Protection Guide from: https://support.omadanetworks.com/r/1004/. Locking Strap Slot Remove the instruction label and insert the AC power cable locking strap into the slot to secure the power cable.

Entwodiksyon 11

Omada Campus Stackable L3 Managed Switch

Chapit 2 Enstalasyon

2.1 Kontni pake a

Asire w ke pake a gen atik sa yo. Tanpri kontakte distribitè w la, si nenpòt nan atik ki nan lis la domaje oswa manke. Chif yo se pou demonstrasyon sèlman. Atik aktyèl yo ka diferan nan aparans ak kantite ak deskripsyon an.

Chanje

Kòd pouvwa ak kab konsole

Gid enstalasyon
Solisyon rezo biznis
Gid enstalasyon
Omada Campus Stackable L3 Managed Switch

Mounting parantèz, vis ak pye kawotchou

2.2 Prekosyon sekirite
Pou evite nenpòt domaj aparèy ak blesi kòporèl ki te koze pa move itilizasyon, ou ta dwe obsève règ sa yo.
Prekosyon Sekirite Kenbe kouran an koupe pandan enstalasyon an. Mete yon braslè ponyèt ki anpeche ESD, epi asire w ke braslè ponyèt la byen an kontak ak po a epi li byen fèmen.
byen konekte ak tè a. Sèvi ak sèlman kòd kouran ki vini ak switch la. Asire w ke vòltaj ekipman pou pouvwa atage matche espesifikasyon yo endike sou panèl la dèyè nan
chanje. Asire w ke switch la enstale nan yon anviwònman ki byen vantile epi twou vantilasyon li yo pa
bloke. Pa louvri oswa retire kouvèti switch la. Anvan w netwaye aparèy la, koupe ekipman pou pouvwa a. Pa netwaye li ak twal dlo a, epi pa janm
use any other liquid cleaning method. Place the device with its bottom surface facing downwards. Only instructed person or skilled person can be allowed to install, replace, or service this device.
Kondisyon pou sit la
Tanperati/Imidite

12 Enstalasyon

Omada Campus Stackable L3 Managed Switch Keep the equipment room at an appropriate level of temperature and humidity. Too much or too little humidity may lead to bad insulation, leakage of electricity, mechanical property changes, and corrosion. High temperatures may accelerate aging of the insulation materials, significantly shortening the service life of the device. To find out the best temperature and humidity conditions for the device, check the Appendix B Specifications. Clearness
Pousyè a akimile sou switch la ka absòbe elektrisite estatik ak rezilta nan kontak pòv nan pwen kontak metal. Gen kèk mezi yo te pran pou aparèy la anpeche elektrisite estatik, men twò fò elektrisite estatik ka lakòz domaj ki ka touye moun nan eleman elektwonik yo sou tablo sikwi entèn la. Pou evite efè elektrisite estatik sou operasyon switch la, bay anpil enpòtans ak atik sa yo: Pousyè aparèy la regilyèman, epi kenbe lè andedan kay la pwòp. Kenbe aparèy la byen chita epi asire ke elektrisite estatik la te transfere. Entèferans elektwomayetik
Eleman elektwonik ki gen ladan kapasite ak enduktans sou aparèy la ka afekte pa entèferans ekstèn, tankou emisyon konduit pa kouple kapasite, kouple inductance, ak kouple enpedans. Pou diminye entèferans yo, asire w ke ou pran mezi sa yo: Sèvi ak ekipman pou pouvwa a ki ka efektivman filtre entèferans nan griy elektrik la. Kenbe aparèy la lwen frekans segondè ak aparèy kouran fò tankou transmèt radyo
estasyon. Sèvi ak pwoteksyon elektwomayetik lè sa nesesè. Pwoteksyon Zeklè
Enstalasyon 13

Omada Campus Stackable L3 Managed Switch
Ekstrèmman wo voltagKouran yo ka pwodwi imedyatman lè zèklè rive ak lè a nan chemen an egzeyat elektrik ka imedyatman chofe jiska 20,000 °C. Kòm aktyèl sa a enstantane ase fò pou domaje aparèy elektwonik, mezi pwoteksyon zèklè pi efikas yo ta dwe pran. Asire w ke etajè a ak aparèy la byen mete latè. Asire w ke priz kouran an gen yon bon kontak ak tè a. Kenbe yon sistèm kabl rezonab epi evite zèklè pwovoke. Sèvi ak siyal SPD (Aparèy Pwoteksyon Surge) lè fil elektrik deyò.
Nòt: Pou mezi pwoteksyon kont zèklè detaye, gade Gid Pwoteksyon kont Zeklè a nan: https://support.omadanetworks.com/r/1004/. Sit Enstalasyon an
When installing the device on a rack or a flat workbench, attach much importance to the following items: Install the device with its bottom surface facing down only. This equipment is not suitable for use in locations where children are likely to be present. The rack or workbench is flat, stable, and sturdy enough to support the weight of 9.5 kg at least. The rack or workbench has a good ventilation system. The equipment room is well ventilated. The rack is well grounded. Keep the device less than 1.5 meters away from the power socket.
2.3 Zouti Enstalasyon
Phillips tournevis ESD-prevantif vlope ponyèt Cables
Remak: Zouti sa yo pa enkli ak pwodwi nou an. Si sa nesesè, ou ka achte yo separeman.
2.4 Enstalasyon pwodwi
Se switch la ki fèt ak karakteristik devan-a-dèyè dissipation chalè. Lè li travay, lè a sikile jan yo montre anba a. Pou pi bon dissipation chalè, tanpri enstale aparèy la nan yon anviwònman ki byen vantile epi kite espas 5 a 10 cm alantou aparèy la.
14 Enstalasyon

Figi 2-1

Sikilasyon lè

Omada Campus Stackable L3 Managed Switch

Enstalasyon Desktop

Pou enstale aparèy la sou Desktop la, swiv etap sa yo:
1. Mete aparèy la sou yon sifas plat ki fò ase pou sipòte tout pwa aparèy la ak tout ekipman yo.

2. Retire papye fè bak adezif yo nan pye kawotchou yo.

3. Tache pye kawotchou yo nan pati anba a nan aparèy la pou anpeche li glise lè yo mete sou yon Desktop.

Figi 2-2

Enstalasyon Desktop

Pye Anba Notch Aparèy la

Enstalasyon etajè

Pake a gen ladan 6 pè diferan etajè-montage parantèz, foto yo montre anba a epi yo ka diferan de pwodwi aktyèl yo.

Figi 2-3

Mounting parantèz

Gwoup Twou Vis 2

Bracket D Bracket C Bracket B Bracket A

Gwoup Twou Vis 1
Gwoup Twou Vis 3

Bracket F

Screw Hole Group 4-2 (for device with 420mm depth)

Gwoup Twou Vis 5

Vis Twou

Gwoup 4-1

Screw Hole Group 4-3

(for device with 380mm depth)

(for device with

460mm depth)

Bracket E

Enstalasyon 15

Omada Campus Stackable L3 Managed Switch

Before installing the device in an EIA standard-sized, 19-inch rack, please check the efficiency of the grounding system and the stability of the rack, then wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well grounded. Bracket B, C & E have two adjustable ears, please measure the distance between the front-post rack and the rear-post rack, and determine a suitable mounting method from below:

Metòd

Demonstrasyon

Front: Bracket A Rear: Bracket D (Screw Hole Group 1) + Bracket B (Ear towards back)

Distans etajè
(For device with a depth of 380mm)

Distans etajè
(For device with a depth of 420mm)

Distans etajè
(For device with a depth of 460mm)

498-640mm 538-680mm 578-720mm

Front: Bracket A Rear: Bracket D (Screw Hole Group 1) + Bracket C (Ear towards back)

477-498mm 517-538mm 557-578mm

Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket C (Ear towards back)

429-477mm 469-517mm 509-557mm

Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket C (Ear towards front)

410-429mm 450-469mm 490-509mm

Front: Bracket A Rear: Bracket D (Screw Hole Group 3) + Bracket C (Ear towards back)

357-410mm 397-450mm 437-490mm

Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket B (Ear towards back)

282-410mm 322-450mm 362-490mm

16 Enstalasyon

Omada Campus Stackable L3 Managed Switch

Front: Bracket A Rear: Bracket F (Screw Hole Group 4) + Bracket E (Ear towards back)

555-936mm 555-936mm 555-936mm

Front: Bracket A Rear: Bracket F (Screw Hole Group 5) + Bracket E (Ear towards back)

743-1121mm 743-1121mm 743-1121mm

Pou enstale aparèy la, swiv enstriksyon ki dekri anba a:

1. Attach the M6 nuts to the racks.

Figi 2-4

Fikse Nwa M6 yo

×8

2. Attach the mounting brackets (B, C or E) to the rear-post racks and secure them with the provided M6 screws, as illustrated in the following figure.

Figi 2-5

Enstale Sipò sou Manch yo

or

3. Attach the brackets A & D/F to the switch with the provided M3 screws.

Enstalasyon 17

Omada Campus Stackable L3 Managed Switch

Figi 2-6

Enstale Sipò yo sou Switch la

4. After the brackets are attached to the device, hold the switch with attached brackets up until it aligns with the brackets on the racks, and gently push the switch backwards until it is in place, then secure the device on the racks with M6 screws and fix brackets B/C or E to brackets D or F with M4 screws on both sides.

Figi 2-7

Enstale Switch sou Rack yo

Caution: Leave 5 to 10 cm gaps around the devices for air circulation. Avoid placing heavy things on the device. Mount devices in the order demonstrated above and ensure a certain clearance between devices for
the purpose of heat dissipation.

18 Enstalasyon

Omada Campus Stackable L3 Managed Switch

Enstalasyon modil ekipman pou pouvwa

S6500-24GP4XF is shipped with a PSM500-AC power supply module installed, S6500-48GP6XF/ S6500-24MPP4Y/S6500-48MPP6Y is shipped with a PSM900-AC power supply module installed, and S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S750032C is shipped with a PSM550-AC power supply module installed. It looks like below, and the image may differ from your actual product.

Figi 2-8

Aparans Modil Alimantasyon an

AC Power Cord Connector
FANATIK

Klip Retainer

Manch Ekstraksyon

dirije

Locking Strap Slot Release Handle

Si ou bezwen ajoute yon lòt modil ekipman pou pouvwa, tanpri swiv etap sa yo:

1. Mete yon braslè ponyèt ki anpeche ESD, epi asire w ke li byen an kontak ak po w epi li byen konekte ak tè a.

2. Peze manch pou retire modil la ak yon men, epi kenbe pati anba modil la ak lòt men an. Pouse modil la dousman sou ray gid fant lan.

3. Lage manch ekstraksyon an pou fikse modil ekipman pou pouvwa a an plas.

Figi 2-9

Enstale modil la Pwovizyon pou pouvwa

Manch lage

Caution: Do not plug the power cord until the power supply module installation is completed. When installing a power supply module, make sure it is set correctly in the operation of installation. Do not use too much force in the installation. If resistance is encountered or positions of the power
supply module appear larger during installation, you must first remove the module and then reinstall the module. If the Retainer Clips cannot spring up naturally and the power module is blocked, it may be due to the power supply module is not installed properly. Please check carefully.
The power supply module is designed with a locking strap slot. If you need to secure the power cable with the included locking strap, please follow the steps:
1. Mete yon braslè ponyèt ki anpeche ESD, epi asire w ke li byen an kontak ak po w epi li byen konekte ak tè a.
Enstalasyon 19

Omada Campus Stackable L3 Managed Switch
2. Remove the instruction label on the AC power cable locking strap slot. 3. Attach the clamp to the AC power cable and insert the locking strap into the slot. 4. Adjust tightness and distance of the locking strap using clips to ensure the cable is securely fastened.
Figure 2-10 Installing the Locking Strap

Si ou bezwen retire modil ekipman pou pouvwa a, tanpri swiv etap sa yo:
1. Mete yon braslè ponyèt ki anpeche ESD, epi asire w ke li byen an kontak ak po w epi li byen konekte ak tè a.
2. Depress the retainer clip to release the locking strap, and then remove the power cord from the external power supply system and the power module.
3. Press the extraction handle of the module with one hand, and pull the extraction handle using your other hand, until the module completely comes out of the chassis.
Caution: Unplug the power cord first, then remove the power supply module. When removing a power supply module, make sure that the power supply module is set correctly in the
operation of installation. In order to better protect the power supply module during removal, it is recommended that you
package it in an antistatic bag.
Enstalasyon Modil Vantilatè
S6500-24GP4XF/S6500-48GP6XF/S6500-24M4Y/S6500-24MPP4Y/S6500-48M6Y/S650048MPP6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S7500-32C is shipped with hot-swappable fan modules installed. They look like below, and the images may differ from your actual product.
Figi 2-11 Aparans Modil fanatik la
dirije

20 Enstalasyon

Extraction Handle Retainer Clips Release Handle

Omada Campus Stackable L3 Managed Switch For normal operation of the switch, please ensure that models with 5 fan modules maintain at least 4 operational modules, while models with 4 fan modules maintain at least 3 operational modules. If one fan module is damaged, please replace it as follows: 1. Wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well
konekte atè. 2. Peze manch pou retire modil la ak yon men, epi rale manch pou retire a jiskaske
Modil la soti nèt nan chasi a.
Figi 2-12 Retire yon modil fanatik ki andomaje
3. Press the extraction handle of a new fan module with one hand, and hold the bottom of the module using your other hand. Gently push the module in along the slot guide rail.
4. Release the extraction handle to fix the power supply module in place. Caution: S6500-24GP4XF/S6500-48GP6XF/S6500-24M4Y/S6500-24MPP4Y/S6500-48M6Y/S6500-48MPP6Y/ S7500-26XF6Y uses hot-swappable fan modules with a maximum speed of 9,000 RPM. S7500-48XF4C/ S7500-24Y4C/S7500-48Y8C/S7500-32C uses hot-swappable fan modules with a maximum speed of 18,000 RPM. Please do not interchange or mix fan modules between models. Sharp edges on the fan module may cause injury, so please operate with caution. Make sure the damaged fan module is in place before you are going to replace it. DO NOT unplug the damaged fan module until the replacement operation. Do not use too much force in the replacement. If resistance is encountered or positions of the fan module appear larger during installation, you must first remove the module and then reinstall the module. If the Retainer Clips cannot spring up naturally and the power module is blocked, it may be due to the fan module is not installed properly. Please check carefully.
Enstalasyon 21

Omada Campus Stackable L3 Managed Switch

Chapit 3 Koneksyon

3.1 Ethernet Port

Konekte yon pò Ethernet nan switch la nan òdinatè a pa RJ45 kab jan figi sa a montre.

Figi 3-1

Konekte pò RJ45 la

Pò RJ45

RJ45 kab

3.2 10G SFP+/25G SFP28/100G QSFP28 Slot

The following figure demonstrates the connection of 10G SFP+/25G SFP28/100G QSFP28 slot to an optical module

Figi 3-2

Inserting the Fiber Module

Slot Fiber Module

3.3 Pò konsole
CLI (Entèfas Liy Kòmand) pèmèt ou jere switch la, kidonk ou ka chaje CLI a apre ou fin konekte PC yo oswa Tèminal yo nan pò konsole sou switch la atravè yon kab (yo bay yon kab konsole RJ45, alòske yo pa bay kab Kalite-C).
Konekte pò konsole RJ45 aparèy la ak òdinatè w lan pa kab konsole a jan figi sa a montre.

22 Koneksyon

Figi 3-3

Konekte pò a konsole (RJ45).

Omada Campus Stackable L3 Managed Switch

Konekte pò konsole Tip-C aparèy la ak òdinatè w lan pa kab Tip-C (ki pa bay la) jan figi sa a montre.

Figi 3-4

Konekte pò konsole (USB).

Note: RJ45 console port and Type-C console port cannot be used concurrently. Type-C Console port takes
priority over the RJ45 console port. The Type-C console port is hot-pluggable while the RJ45 console port is not. Keep the device power
off when plugging the console cable into the RJ45 console port. Do not connect the console port with other ports by RJ45 cable.
3.4 Verifye Enstalasyon
Apre w fin ranpli enstalasyon an, verifye atik sa yo: Ta dwe gen 5 a 10 cm nan clearance alantou aparèy la pou vantilasyon epi asire w ke lè a koule.
se adekwat. Voltage nan ekipman pou pouvwa a satisfè egzijans D 'vol latage nan aparèy la. Priz pouvwa a, aparèy ak etajè yo byen chita. Aparèy la kòrèkteman konekte ak lòt aparèy rezo.
Koneksyon 23

Omada Campus Stackable L3 Managed Switch

3.5 pouvwa sou

Ploge konektè fi nan fil elektrik yo bay la nan priz pouvwa aparèy la epi ploge konektè pozitif la nan yon priz kouran jan figi sa a montre. Asire w ke voltage nan ekipman pou pouvwa a satisfè egzijans D 'vol latage (100-240 V ~ 50/60 Hz).

Figi 3-5

Konekte ak ekipman pou pouvwa

Note: The figure is to illustrate the application and principle. The provided plug and module in your region
may differ from the figures above. Generally PWR1 takes priority over PWR2.

3.6 Inisyalizasyon
Aprè aparèy la mache, li kòmanse pwòp tèt ou-tès la. Yon seri tès kouri otomatikman asire aparèy la fonksyone byen. Pandan tan sa a, endikatè ki ap dirije li yo pral reponn nan lòd sa a:
1. Endikatè PWR dirije limyè yo sou tout tan. SYS ki ap dirije ak endikatè yo ki ap dirije nan tout pò yo kenbe la.
2. Apre apeprè yon minit, endikatè SYS ki ap dirije ak ki ap dirije tout pò yo ap flache pou yon ti tan epi yo fèmen.
3. Plizyè segonn pita, endikatè SYS ki ap dirije a ap flache, ki reprezante yon inisyalizasyon siksè.
3.7 Pile Topoloji
With stackable design, the switches can be stacked into one stack topology for higher reliability, larger bandwidth, and simpler networking. To build the stack topology, you need to prepare 2-12 switches and enough 10G SFP+/25G SFP28/100G QSFP28 modules/cables. For more details, see the table below:

Chanje

Modèl konpatib (yo)

Kantite

S6500-24G4XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-48G6XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-24GP4XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-48GP6XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-24M4Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y S6500-24MPP4Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y

2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode)

24 Koneksyon

Omada Campus Stackable L3 Managed Switch

S6500-48M6Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y

S6500-48MPP6Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y

S7500-26XF6Y S7500-26XF6Y

S7500-48XF4C S7500-48XF4C

S7500-24Y4C S7500-24Y4C

S7500-48Y8C S7500-48Y8C

S7500-32C

S7500-32C

2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode)

Gen twa estrikti topoloji pile pou diferan senaryo, tanpri bati topoloji apwopriye a selon bezwen ou yo:

1. Topoloji chèn: Topoloji chèn se relativman senp epi li pa mande pou koneksyon kab ant premye ak dènye inite a. Li apwopriye pou anpile long distans, men fyab li relativman ba.

Figi 3-6

Topoloji chèn

Gwoup Port 2 anpile
Gwoup Port 1 anpile

...

2. Topoloji bag: Topoloji bag gen pi wo fyab konpare ak topoloji chèn lan. Lè youn nan chenn yo nan topoloji bag la dekonekte, topoloji bag la vin tounen yon topoloji chèn, men tout sistèm chemine a ka toujou travay nòmalman. Topoloji bag la mande pou koneksyon kab ant premye ak dènye inite a, kidonk li pa apwopriye pou anpile long distans.

Figi 3-7

Topoloji bag

Gwoup Port 2 anpile

Gwoup Port 1 anpile

...

Koneksyon 25

Omada Campus Stackable L3 Managed Switch

3. Topoloji Star: Topoloji Star konekte switch yo nan yon switch prensipal santral, Se poutèt sa, li ka siyifikativman ogmante pousantaj transmisyon done ant switch manm pandan y ap bay jesyon inifye.

Figi 3-8

Star Topoloji

Gwoup Port 2 anpile

Gwoup Port 3 anpile

Gwoup Port 1 anpile

...

Note: The stacking port is not allowed to connect to non-stacking port, as it may affect the operation of the
device. Stacking ports with the same group ID are not allowed to connect to stacking ports with different
group IDs, neither to different devices. A stacking port group is a logical port dedicated to stacking and needs to be bound to a stacking port.
A stacking port group can be bound to one or more stacking ports to improve bandwidth and reliability.

26 Koneksyon

Omada Campus Stackable L3 Managed Switch

Chapit 4 Konfigirasyon

4.1 Konfigirasyon finiview
Chanjman an sipòte de opsyon konfigirasyon:
Mòd otonòm: Konfigure ak jere switch la poukont li. Mòd Kontwolè: Konfigure ak jere aparèy rezo yo santralman. Li rekòmande nan la
rezo gwo echèl, ki gen ladann aparèy mas tankou pwen aksè, switch, ak pòtay.
Remak: Lè yo chanje switch la soti nan Mode autonome nan mòd kontwolè, konfigirasyon nan switch la ap pèdi. Pou plis detay, al gade nan dokiman ki gen rapò yo sou sant la download nan ofisyèl nou an websit entènèt la: https://support.omadanetworks.com/product/.

4.2 autonome mòd

Nan mòd otonòm, sèvi ak yon òdinatè pou konfigirasyon ak jere switch la lè l sèvi avèk GUI (Graphical User Interface) oswa CLI (koòdone liy kòmand).

Figi 4-1

Topoloji pou mòd otonòm

Chanje

PC

Sèvi ak entèfas a
1. Pou jwenn aksè nan paj la jesyon nan switch la, asire w ke switch la ak òdinatè yo nan menm subnet la. Louvri yon navigatè epi tape adrès IP switch la nan jaden adrès la, lè sa a peze la Antre nan kle.
Si switch la jwenn adrès IP nan men sèvè DHCP a (jeneralman yon pòtay), jwenn adrès IP switch la sou sèvè DHCP a.
Si ou pa, sèvi ak adrès IP default 192.168.0.1 lanse paj jesyon switch la.

2. Premye fwa ou konekte, mete non itilizatè a ak modpas la pou pi byen pwoteje rezo ou ak aparèy ou yo. Apre sa, sistèm nan ap otomatikman redireksyon ou tounen nan koòdone koneksyon an pou otantifye ak nouvo kalifikasyon ou kreye yo.

3. Apre yon login siksè, paj prensipal la ap parèt. Ou ka klike sou meni yo sou bò anwo ak bò gòch nan konfigirasyon fonksyon ki koresponn lan.
Pou konfigirasyon detaye yo, al gade Gid pou Itilizatè ak Gid pou CLI. Gid yo ka jwenn sou sant la download nan ofisyèl nou an websit entènèt la: https://support.omadanetworks.com/product/.
Sèvi ak CLI a Mete yon koneksyon Telnet oswa SSH pou jwenn aksè nan switch la atravè CLI.

Konfigirasyon 27

Omada Campus Stackable L3 Managed Switch

Sèvi ak pò konsole pou jwenn aksè nan switch la. Lè w ap itilize pò konsole a, kòmanse pwogram imitasyon tèminal la (tankou Hyper Terminal) sou PC a epi configured pwogram imitasyon tèminal la jan sa a:

Pousantaj baud 38400 bps

Done Bits 8

Parite Okenn

One Stop Bits 1

Kontwòl koule Okenn

Pou konfigirasyon detaye yo, al gade Gid pou Itilizatè ak Gid pou CLI. Gid yo ka jwenn sou sant la download nan ofisyèl nou an websit entènèt la: https://support.omadanetworks.com/product/.
Note: You may need to change the password the first time you log in, which will better protect your network and devices.

4.3 Mòd Kontwolè
Controller Mode applies to the large scale network with mass devices. All devices can be centrally configured and monitored via Omada Pro Hardware Controller (C5300), Omada Pro Software Controller, or Omada Pro Cloud-Based Controller.
Note: Before the following configurations, make sure the switch can access the internet. When using Omada Pro Hardware/Software/Cloud-based Controller, make sure the switch and the controller are in the same subnet. Typically, the switch obtains IP address from the DHCP server. You can check the switch’s IP address on the DHCP server.

Via Omada Pro Hardware Controller (C5300)

Omada Pro Hardware Controller (C5300) is a good alternative if you have no spare PC to keep running Omada Pro Software Controller in the network. It needs to be purchased additionally. Follow the steps below to configure the Omada Pro Hardware Controller (C5300).

Figi 4-2

Manage the network via Omada Pro Hardware Controller (C5300)

Gateway switch

Omada Pro Hardware Controller (C5300) EAP
28 Konfigirasyon

EAP

EAP

Kliyan yo

Omada Campus Stackable L3 Managed Switch

Note: Before you start, be sure to power up and connect your devices according to the topology figure. A DHCP server (typically a gateway with DHCP function enabled) is required to assign IP addresses to
the EAPs and clients in your local network. Omada Pro Controller must have network access to some Omada campus devices (the gateway,
switch, or APs) in order to find, adopt, and manage them.

1. Jwenn adrès IP pòtay la. Louvri liy kòmand lan sou PC ou epi antre ipconfig. Nan lis rezilta yo, jwenn Pòtay Defo a, ki se tou adrès IP pòtay la.
2. Lanse yon web navigatè a epi antre adrès IP pòtay la. Konekte sou pòtay la web paj. Lè sa a, ale nan Rezo> LAN> Lis Kliyan DHCP pou jwenn adrès IP kontwolè w ​​la dapre adrès MAC li.
3. Antre adrès IP kontwolè w ​​la nan ba adrès la pou ouvri li web paj.
4. Sou kontwolè Omada Pro a web paj, swiv sòsye an pou konplete konfigirasyon rapid la.
5. Apre konfigirasyon rapid la, paj login la parèt. Antre non itilizatè a ak modpas ou te kreye epi klike sou Log in. Lè sa a, ou ka plis konfigirasyon kontwolè a.
6. Si ou vle jere aparèy yo a distans, swiv etap kap vini yo:
a. Asire w ke Aksè Cloud yo aktive sou kontwolè w ​​la. Pa default, Aksè Cloud yo aktive. Asire w ke Cloud LED la ap flache dousman.

b. Lanse a web navigatè epi antre https://omada.tplinkcloud.com nan ba adrès la. Antre ID TP-Link ou ak modpas ou pou w konekte. Klike sou + Add Controller epi chwazi Hardware Controller pou ajoute kontwolè w ​​la. Lè sa a, ou ka plis konfigirasyon kontwolè a.

For more details, refer to the Installation Guide of C5300.

Via Omada Pro Software Controller

Download the Omada Pro Software Controller on a PC with Windows OS or Linux OS. Then run the file and follow the wizard to install the Omada Pro Software Controller. Follow the steps below to configure the Controller.

Figi 4-3

Jere rezo a atravè Omada Pro Software Controller

Gateway

Chanje

Kontwolè

Kontwolè lojisyèl Omada Pro AP

AP

AP

k ap kouri sou PC lame a

Kliyan yo

Konfigirasyon 29

Omada Campus Stackable L3 Managed Switch

1. Launch the Omada Pro Software Controller on your PC. After the initiation process, the controller automatically opens its web paj. Si ou pa, klike sou Lanse yon navigatè pou jere rezo a.
2. Sou kontwolè Omada Pro a web paj, swiv sòsye an pou konplete konfigirasyon rapid la.
3. Apre konfigirasyon rapid la, paj login la parèt. Antre non itilizatè a ak modpas ou te kreye epi klike sou Log in. Lè sa a, ou ka plis konfigirasyon kontwolè a.
4. Si ou vle jere aparèy yo a distans, swiv etap kap vini yo:
a. Make sure that Cloud Access is enabled on your controller and your controller has been bound with your TP-Link ID. On the Omada Pro Controller’s web paj, ale nan Anviwònman > Cloud Aksè pou pèmèt Cloud Aksè epi mare ID TP-Link ou a. Si ou te mete li nan konfigirasyon rapid la, sote etap sa a.
b. Lanse a web navigatè epi antre https://omada.tplinkcloud.com nan ba adrès la. Antre ID TP-Link ou ak modpas ou pou w konekte. Yon lis kontwolè ki te mare ak ID TP-Link ou a ap parèt. Lè sa a, ou ka klike sou Lanse pou plis konfigirasyon kontwolè a.

Note: To manage your devices, Omada Pro Software Controller needs to keep running on your computer.

Via Omada Pro Cloud-Based Controller

Omada Pro Cloud-Based Controller se yon bon altènatif san yo pa bezwen enstale kontwolè lojisyèl an sou yon PC.

Lisans yo bezwen achte anplis.

Figi 4-4

Jere rezo a atravè Omada Pro Cloud-Based Controller

Nwaj Omada

Gateway

Chanje

AP

AP

AP

AP

Kliyan yo
1. Contact the sales staff to grant the Omada Pro Cloud-Based Controller permission. 2. Launch a web navigatè a epi antre https://omada.tplinkcloud.com nan ba adrès la. Konekte avèk
your TP-Link ID.
30 Konfigirasyon

Omada Campus Stackable L3 Managed Switch 3. Click + Add Controller and choose Cloud-Based Controller to add an Omada Pro Controller. Then
Ou ka lanse kontwolè a pou adopte epi jere aparèy yo. * Aplikasyon Omada Avèk aplikasyon Omada a, ou kapab tou jere kontwolè w ​​la nan yon sit lokal oswa yon sit aleka atravè aparèy mobil ou. Pou konfigirasyon detaye yo, gade Gid Itilizatè kontwolè a. Ou ka jwenn gid la nan sant telechajman ofisyèl nou an. websit entènèt la: https://support.omadanetworks.com/product/.
Konfigirasyon 31

Omada Campus Stackable L3 Managed Switch
Apendis A depanaj
Q1. Kisa mwen ta ka fè si mwen bliye non itilizatè a ak modpas nan switch la?
1. Konekte pò konsole PC a nan pò konsole switch la epi louvri yon pwogram imitasyon tèminal.
2. Etenn epi rekòmanse switch la. Fè aksyon ki endike nan pwogram imitasyon tèminal la pou rive nan meni bootUtil la. Aksyon an diferan de pwodwi a pwodwi. Aksyon posib yo ki nan lis anba a: · Peze nenpòt kle pou sispann otoboot. · Peze CTRL-B pou rive nan meni bootUtil la.
3. Meni bootUtil la ap parèt. Antre nimewo 6 la pou chwazi opsyon "Rekiperasyon modpas" la epi antre Y pou efase tout itilizatè yo ak modpas yo. Apre sa, ou ka retabli non itilizatè a ak modpas la.
K2. Poukisa LED PWR a pa fonksyone byen? LED PWR/Power la ta dwe limen lè sistèm kouran an ap fonksyone nòmalman. Si LED PWR/Power la pa fonksyone byen, swiv etap sa yo:
1. Asire w ke kab kouran an byen konekte, epi kontak kouran an nòmal. 2. Asire w ke vòl latage nan ekipman pou pouvwa a satisfè egzijans D 'vol latage nan
chanje.
Q3. Kisa mwen ta dwe fè si mwen pa ka jwenn aksè a web paj jesyon an? Eseye sa ki annapre yo:
1. Tcheke chak pò ki ap dirije sou switch la epi asire w ke kab Ethernet la konekte byen. 2. Eseye yon lòt pò sou switch la epi asire w ke kab Ethernet la apwopriye epi li travay nòmalman. 3. Etenn switch la epi, apre yon ti tan, limen li ankò. 4. Asire w ke adrès IP PC ou mete nan sous-rezo switch la. 5. Si ou toujou pa ka jwenn aksè nan paj konfigirasyon an, reset switch la nan default faktori li yo. Lè sa a
adrès IP PC ou ta dwe fikse kòm 192.168.0.x ("x" se nenpòt ki nimewo soti nan 2 a 254) ak mask subnet kòm 255.255.255.0.
K4. Poukisa pwogram emulasyon tèminal la pa parèt byen? Eseye sa ki annapre yo:
1. Asire w ke ekipman pou pouvwa a nòmal epi kab konsole a byen konekte. 2. Tcheke si kab konsole a se bon kalite. 3. Asire ke paramèt pwogram imitasyon tèminal la kòrèk: konfigirasyon Bits pa segonn
kòm 38400, Bits Done kòm 8, Parite kòm Okenn, Bits Stop kòm 1, ak Kontwòl Flow kòm Okenn.
32 Apendis A Depanaj

Omada Campus Stackable L3 Managed Switch

Apendis B Espesifikasyon

Specifications for S6500 Series Switches

Atik

Kontni

IEEE 802.3, IEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3z, IEEE 802.3ae, IEEE 802.3x

Estanda

IEEE 802.3af/at (For S6500-24GP4XF, S6500-48GP6XF) IEEE 802.3af/at/bt (For S6500-24MPP4Y, S6500-48MPP6Y)

IEEE 802.3bz, IEEE 802.3by, IEEE 802.3cc (For S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y)

10BASE-T: 2-pair UTP/STP of Cat. 3,4,5 (maximum 100 m) 100BASE-TX: 2-pair UTP/STP of Cat. 5 or above (maximum 100 m) 1000BASE-T: 4-pair UTP/STP of Cat. 5e or above (maximum 100 m) 2.5GBASE-T: 4-pair UTP/STP of Cat. 5e or above (maximum 100 m) Transmission Medium 1000BASE-SX/LX/LX10/BX10: MMF, SMF 10GBASE-SR/LR: MMF, SMF 10G SFP+ Direct Attach Cable (SM5220-1M, SM5220-3M) 25GBASE-SR/LR: MMF, SMF (SM6110-SR, SM6110-LR) 25G SFP28 Direct Attach Cable (SM6220-1M)

S6500-24G4XF/S6500-24M4Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, Port 1-24, Port 25-28 S6500-24GP4XF/S6500-24MPP4Y: PWR1, PWR2, SYS, FAN, PoE Max, MGMT, MST, SPEED, STK, PoE, Port 1-24, Port 25-28 LED S6500-48G6XF/S6500-48M6Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, Port 1-48, Port 49-54 S6500-48GP6XF/S6500-48MPP6Y: PWR1, PWR2, SYS, FAN, PoE Max, MGMT, MST, SPEED, STK, PoE, Port 1-48, Port 49-54

Apendis B Espesifikasyon 33

Omada Campus Stackable L3 Managed Switch

Bidjè PoE

For S6500-24GP4XF: 402W (with 1*PSM500-AC, by default) 720W (with 1*PSM900-AC) 720W (with 2*PSM500-AC) 720W (with 1*PSM500-AC and 1*PSM900-AC) 720W (with 2*PSM900-AC) For S6500-48GP6XF: 764W (with 1*PSM900-AC, by default) 384W (with 1*PSM500-AC) 812W (with 2*PSM500-AC) 1176W (with 1*PSM500-AC and 1*PSM900-AC) 1440W (with 2*PSM900-AC) For S6500-24MPP4Y: 751W (with 1*PSM900-AC, by default) 378W (with 1*PSM500-AC) 802W (with 2*PSM500-AC) 1168W (with 1*PSM500-AC and 1*PSM900-AC) 1534W (with 2*PSM900-AC) For S6500-48MPP6Y: 701W (with 1*PSM900-AC, by default) 328W (with 1*PSM500-AC) 752W (with 2*PSM500-AC) 1118W (with 1*PSM500-AC and 1*PSM900-AC) 1484W (with 2*PSM900-AC)

Tanperati ak Altitid Operasyonèl

For S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y: -5 °C to 50 °C (23 °F to 122 °F) @ 300 meters -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters For S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y: -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters

Tanperati Depo -40 °C a 70 °C (-40 °F a 158 °F)

Operasyon imidite 10% a 90% RH ki pa kondanse

Depo Imidite

5% a 90% RH ki pa kondanse

34 Apendis B Espesifikasyon

Omada Campus Stackable L3 Managed Switch

Specifications for S7500 Series Switches

Atik

Kontni

Estanda

IEEE 802.3, IEEE 802.3x IEEE 802.3z, IEEE 802.3ae (For S7500-26XF6Y, S7500-48XF4C, S7500-24Y4C, S7500-48Y8C IEEE 802.3by, IEEE 802.3cc (For S7500-26XF6Y, S7500-24Y4C, S7500-48Y8C) IEEE 802.3 ba, IEEE 802.3bm (For S7500-48XF4C , S7500-24Y4C, S7500-48Y8C, S7500-32C)

1000BASE-SX/LX/LX10/BX10: MMF, SMF 10GBASE-SR/LR: MMF, SMF 10G SFP+ Direct Attach Cable (SM5220-1M, SM5220-3M) 25GBASE-SR/LR: MMF, SMF (SM6110-SR, SM6110-LR) 25G SFP28 Direct Attach Cable (SM6220-1M) 40GBASE-SR4/LR4: MMF, SMF (For S7500-48XF4C, S7500-24Y4C, Transmission Medium S7500-48Y8C, S7500-32C) 40G QSFP+ Direct Attach Cable (For S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C) 100GBASE-SR4/LR4: MMF, SMF (SM9110-SR4 for S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C) 100G QSFP28 Direct Attach Cable (SM9220-1M for S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C)

dirije
Tanperati ak Altitid Operasyonèl

S7500-26XF6Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPD, STK, SFP+, SFP28 S7500-48XF4C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, SFP+, QSFP28 S7500-24Y4C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPD, STK, SFP28, QSFP28 S7500-48Y8C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, SFP28, QSFP28 S7500-32C: PWR1, PWR2, SYS, MGMT, FAN, MST, SPEED, STK, QSFP28 -5 °C to 45 °C (23 °F to 113 °F) @ 300 meters -5 °C to 40 °C (23 °F to 104 °F) @ 2,000 meters -5 °C to 35 °C (23 °F to 95 °F) @ 3,000 meters

Tanperati Depo -40 °C a 70 °C (-40 °F a 158 °F)

Operasyon imidite 10% a 90% RH ki pa kondanse

Depo Imidite

5% a 90% RH ki pa kondanse

For S7500-26XF6Y, S7500-48XF4C, and S7500-24Y4C, the maximum operating temperature supported can reach 50 °C (122 °F) @ 300 meters, 45 °C (113 °F) @ 2,000 meters, and 40 °C (104 °F) @ 3,000 meters.
Altitid ki sipòte a se soti nan nivo lanmè rive nan 5000 m. Li enpòtan pou note ke lè altitid la pi wo pase 2000 m, pou chak 220 mèt ogmantasyon altitid, tanperati maksimòm fonksyònman an ap bese pa 1°C (1.8°F).

Apendis B Espesifikasyon 35

Omada Campus Stackable L3 Managed Switch

Espesifikasyon pou modil ekipman pou pouvwa

PSM500-AC
(For S6500-24GP4XF/ S6500-48GP6XF/ S6500-24MPP4Y/ S6500-48MPP6Y)

PSM900-AC
(For S6500-24GP4XF/ S6500-48GP6XF/ S6500-24MPP4Y/ S6500-48MPP6Y)

PSM550-AC
(For S6500-24M4Y/ S6500-48M6Y/ S7500-26XF6Y/ S7500-48XF4C/ S7500-24Y4C/ S7500-48Y8C/ S7500-32C)

Antre pouvwa

100 V­240 V~ 50/60 Hz 8A

100-120V (included)~ 50/60Hz 12A (for locations using low voltage, see specifications for specific countries/ regions)
120 (not included)240V~ 50/60Hz 10A (for other locations)

100 V­240 V~ 50/60 Hz 7A

Sòti Voltage

Primary: 53.5 VDC Standby: 12 VDC

Primary: 53.5 VDC Standby: 12 VDC

Primary: 12 VDC Standby: 12 VDC

Sòti aktyèl

9.35 A (Maksimòm)

16.5 A (Maksimòm)

45 A (Maksimòm)

Sortie pouvwa

500 W (Maksimòm)

900 W (Maksimòm)

550 W (Maksimòm)

Opere altitid

For PSM500-AC/PSM900-AC: Sea level to 3000 m For PSM550-AC: Sea level to 5000 m

36 Apendis B Espesifikasyon

Avètisman mak CE
Sa a se yon pwodwi klas A. Nan yon anviwònman domestik, pwodui sa a ka lakòz entèferans radyo, nan ka sa a itilizatè a ka oblije pran mezi apwopriye.
Inyon Ewopeyen Deklarasyon Konfòmite
TP-Link deklare ke switch la konfòm ak egzijans esansyèl yo ak lòt dispozisyon enpòtan nan direktiv 2014/30/EU, 2014/35/EU, 2011/65/EU ak (EU)2015/863. ​​Ou ka jwenn Deklarasyon Konfòmite Inyon Ewopeyen orijinal la nan https://www.tp-link.com/en/support/ce/
UK Deklarasyon Konfòmite
TP-Link deklare ke switch la konfòm ak egzijans esansyèl yo ak lòt dispozisyon ki enpòtan nan Règleman Konpatibilite Elektwomayetik 2016 yo ak Règleman Ekipman Elektrik (Sekirite) 2016 yo. Ou ka jwenn Deklarasyon Konfòmite orijinal Wayòm Ini a nan https://www.tp-link.com/support/ukca/
, .
ATANSYON:
Double poto, fusion net. Dekonekte prensipal la anvan sèvis la.
Enfòmasyon sou Sekirite
· Kenbe aparèy la lwen dlo, dife, imidite oswa anviwònman cho. · Pa eseye demonte, repare, oswa modifye aparèy la. Si ou bezwen sèvis, tanpri kontakte nou. · Mete aparèy la ak sifas anba li anba. · Se ploge nan kòd la ekipman pou pouvwa itilize kòm aparèy la dekonekte, priz-priz la dwe
fasil pou jwenn aksè. · Branche pwodwi a nan priz miray ki gen koneksyon tè atravè kòd alimantasyon an
or plug. · The socket-outlet shall be installed near the equipment and shall be easily accessible. · The PoE ports shall not be used to charge lithium batteries or devices supplied by lithium
pil.

· Operating temperature: For S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/ S7500-48XF4C/S7500-24Y4C: -5 °C to 50 °C (23 °F to 122 °F) @ 300 meters -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters For S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y: -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters S7500-48Y8C/S7500-32C: -5 °C to 45 °C (23 °F to 113 °F) @ 300 meters -5 °C to 40 °C (23 °F to 104 °F) @ 2,000 meters -5 °C to 35 °C (23 °F to 95 °F) @ 3,000 meters
· : S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/ S7500-24Y4C -5°C 50°C23°F 122°F@ 300 -5°C 45°C23°F 113°F@ 2,000 -5°C 40°C23°F 104°F@ 3,000 S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y -5°C 45°C23°F 113°F@ 2,000 -5°C 40°C23°F 104°F@ 3,000 S7500-48Y8C/S7500-32C -5°C 45°C23°F 113°F@ 300 -5°C 40°C23°F 104°F@ 2,000 -5°C 35°C23°F 95°F@ 3,000
This equipment is not suitable for use in locations
where children are likely to be present.

Tanpri li epi swiv enfòmasyon sekirite ki anwo yo lè w ap opere aparèy la. Nou pa ka garanti ke pa gen okenn aksidan oswa domaj ki pral rive akòz move itilizasyon aparèy la. Tanpri itilize pwodui sa a ak swen epi opere sou pwòp risk ou.

Pou sipò teknik, gid itilizatè ak lòt enfòmasyon, tanpri vizite https://support.omadanetworks.com/, oubyen tou senpleman eskane kòd QR la.
© 2026 TP-Link 7100002759 REV2.0.1

Dokiman / Resous

PDF thumbnailL3 Campus Stackable Managed Switch
User Manual · L3 Campus Stackable Managed Switch, L3, Campus Stackable Managed Switch, Stackable Managed Switch, Managed Switch, Switch

Referans

Poze yon Kesyon

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Poze yon Kesyon

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.