©2025 Daikin Applied, Minneapolis, MN. All rights reserved throughout the world.This document contains the most current product information as of this printing. Daikin Applied Americas Inc. has the right to change the information, design, and construction of the product represented within the document without prior notice. For the most up-to-date product information, please go to www.DaikinApplied.com. ™® MicroTech, Rebel, Maverick II, Roofpak, Pathfinder, Trailblazer, Magnitude, Navigator, and Daikin Applied are trademarks or registered trademarks of Daikin Applied Americas Inc. The following are trademarks or registered trademarks of their respective companies: BACnet from American Society of Heating, Refrigeration and Air-Conditioning Engineers, Inc., and Windows from Microsoft Corporation.

Entwodiksyon

  • Enfòmasyon jeneral
  • Manyèl sa a dekri kijan pou enstale epi opere koòdone itilizatè a distans pou itilize avèk MicroTech Applied Rooftops epi tou avèk kontwolè inite refwadisman ki refwadi ak lè ak dlo nan men Daikin Applied.
    Pou sipò teknik sou kontwolè twati oswa inite endepandan, kontakte Sant Repons Teknik Daikin Applied Air nan 800-432-1342 (AAHTechSupport@daikinapplied.com).
  • For chiller unit controller support, contact the Daikin Applied Chiller Technical Response Center at 800-432-1342 (CHLTechSupport@daikinapplied.com).
    For technical support on PreciseLine unit controllers, contact the Daikin Applied Air Technical Response Center at 800-432-3928 (ATSTechSupport@daikinapplied.com)

Enfòmasyon sou pwodwi

  • The remote user interface is designed for display, system configuration, set-up, and management of MicroTech unit controllers:

DAIKIN-1005-7-Micro-Tech-Unit-Controller-Remote-FIG- (1)

  • Anplis klavye/ekran kontwolè ki monte sou inite a, sistèm kontwòl inite MicroTech yo ka ekipe ak yon koòdone itilizatè a distans ki ka jere jiska uit inite pou chak koòdone. Koòdone itilizatè a distans lan bay aksè a dyagnostik inite a ak ajisteman kontwòl menm jan ak kontwolè ki monte sou inite a.

Karakteristik

  • Push-and-roll navigation wheel with an 8-line by 30- character display format
  • Operating conditions, system alarms, control parameters and schedules are monitored
  • RS-485 or KNX interface for local or remote installation
  • Power from controller, no additional power supply necessary
  • Supports panel mounting and wall mounting

Mesaj Enfòmasyon DanjereDANJE

  • Danje endike yon sitiyasyon danjere, ki pral lakòz lanmò oswa blesi grav si yo pa evite.
  • AVÈTISMAN Avètisman endike yon sitiyasyon potansyèlman danjere, ki ka lakòz domaj pwopriyete, blesi pèsonèl, oswa lanmò si yo pa evite.
  • ATANSYON Atansyon endike yon sitiyasyon ki kapab danjere, ki ka lakòz blesi minè oswa domaj ekipman si yo pa evite.
  • AVI Avi endike pratik ki pa gen rapò ak blesi fizik.

Dokiman referans

Nimewo Konpayi Tit Sous
 

OIM 1202

 

Daikin aplike

Pathfinder Chiller Model AWS Installation, Operation, and Maintenance Manual  

 

 

 

 

 

 

 

 

 

 

www.DaikinAplike.com

 

OIM 1206

 

Daikin aplike

Manyèl Enstalasyon, Operasyon ak Antretyen Refwadisè Trailblazer Modèl AGZ
 

OIM 1242

 

Daikin aplike

Manyèl Enstalasyon, Operasyon, ak Antretyen Refwadisè Pathfinder Modèl AWV
 

IOMM 1033

 

Daikin aplike

Magnitude Model WME, B vintage Magnetic Bearing Centrifugal Chiller Installation, Operation, and Maintenance Manual
 

OIM 1264

 

Daikin aplike

Navigator Model WWV/TWV Water-cooled Chiller Installation, Operation, and Maintenance Manual
OIM 1243 Daikin aplike Trailblazer Chiller Model AMZ
 

OM 1382

 

Daikin aplike

Sistèm twati komèsyal Rebel Packaged, Manyèl Operasyon ak Antretyen
 

OM 1373

 

Daikin aplike

Rebel Applied Rooftop Systems, Operation and Maintenance Manual
 

OM 1357

 

Daikin aplike

Manyèl Operasyon ak Antretyen pou Manipulatè Lè PreciseLine

Done konpozan

Jeneral

  • Figi 1 montre detay sou konsepsyon pyès ki nan konpitè pou entèfas itilizatè a distans.

Plan fizik jeneral la gen ladan l:

  • 5.7 × 3.8 × 1 in (144 × 96 × 26 mm) size
  • 9.1 oz (256.7 g) weight, excluding packaging
  • Lojman plastik

Pouvwa

  • Supplied by the MicroTech unit controller for direct connection
  • Separate 24V DAC power supply, optional for daisy chain connections, Max 85 mA
  • REMAK: Kontakte Sant Repons Teknik Daikin Applied Air nan nimewo 800-432-1342 (AAHTechSupport@daikinapplied.com) or the Chiller Technical Response Center at 800-432-1342 (CHLTechSupport@daikinapplied.com) si ou vle yon ekipman pou kouran apa.

Ekspozisyon

  • LCD type FSTN
  • Resolution dot-matrix 96 x 208
  • Backlight blue or white, user selectable

Kondisyon Anviwònman

  • Operation EC 721-3-3
  • Temperature -40…158°F (-40…+70°C)
  • Restriction LCD -4…140°F (-20…+60°C)
  • Restriction Process-Bus -13…158°F (-25….+70°C)
  • Humidity < 90% RH (no condensation)
  • Air pressure Min. 10.2 psi (700 hPa), corresponding to max. 9843 ft (3000 m) above sea level

DAIKIN-1005-7-Micro-Tech-Unit-Controller-Remote-FIG- (2)

Enstalasyon

  • Pre-Enstalasyon
  • Tanpri sonje bagay sa yo anvan ou monte epi enstale koòdone itilizatè a distans lan.

Konsiderasyon kote yo ye

  • Plasman koòdone itilizatè a distans lan nesesè pou asire bon fonksyònman. Lè w ap chwazi yon kote, evite bagay sa yo:
  • Locations that are outside the operating temperature and humidity range (see Environmental Conditions.)
  • Mounting on rooftop without a careful site evaluation and confirmation
  • Walls that are subject to high vibration
  •  Areas with high humidity exterior walls and other walls that have a temperature differential between the two sides
  • Areas that are close to heat sources such as sunlight, appliances, concealed pipes, chimneys, or other heat-generating equipment.

Mounting Sifas

  • Pou enstalasyon sou sifas, monte koòdone itilizatè a distans lan sou yon sifas plat tankou plak plat oswa platre, yon panèl kontwòl, oswa yon bwat koneksyon elektrik.
  • If mounting onto sheet rock or plaster, use anchors, if necessary
  • For mounting in the unit controller panel, electrical junction box, or other metal enclosure, use the supplied magnets.

Pati

Deskripsyon Nimewo Pati
Entèfas Itilizatè MicroTech a Distans 1934080031,2
Connectors (using CE+ CE- connection option) 193410302
  1. Note that part number 193408001 is no longer available.
  2. For daisy-chaining unit controllers together, a 2-pin connector (PN 193410302), is required for each unit controller. The 2-pin connector is not required for direct-connecting unit controllers.
  3. Pou jwenn biwo pati lokal ou a, vizite www.DaikinApplied.com oswa rele 800-37PARTS (800-377-2787).
  4. Montaj ak Konekte
  5. Seksyon sa a dekri kijan pou monte koòdone itilizatè a distans la epi konekte li ak youn oubyen plizyè kontwolè inite MicroTech.
  6. Electrostatic discharge hazard. Can cause equipment damage. This equipment contains sensitive electronic components that may be damaged by electrostatic discharge from your hands. Before you handle a communication module, you need to touch a grounded object, such as the metal enclosure, in order to discharge the electrostatic potential from your body.
  7. WARNING Electric shock hazard. Can cause personal injury or equipment damage. This equipment must be properly grounded.

Only personnel knowledgeable in the operation of the equipment being controlled must perform connections and service to the unit controller.

  1.  Remove plastic cover (Figure 2).
  2. Mount the remote user interface. The remote user interface can be either panel-mounted or wall-mounted as shown in Figure 3. See Figure 4 and Figure 5 for terminal connections for each of the mounting locations.

DAIKIN-1005-7-Micro-Tech-Unit-Controller-Remote-FIG- (3)

DAIKIN-1005-7-Micro-Tech-Unit-Controller-Remote-FIG- (4)

Fil elektrik Entèfas Itilizatè a Aleka

  1. Ou ka konekte koòdone itilizatè a distans lan ak kontwolè inite MicroTech la nan de fason diferan:
  2. 1. Daisy-chain connection to as many as eight units.
  3. 2. Direct connection to a single unit controller. Connection and wiring instructions in each case are described in the following section. See Table 1 for wire sizing and distance limitations.
  4. NOTE: Power is supplied by the MicroTech unit controller. If a separate 24V power supply is desired, please contact either the Daikin Applied Air Technical Response Center at (800) 432- 1342 (AAHTechSupport@daikinapplied.com) or the Chiller Technical
  5. Response Center at 800-432-1342 (CHLTechSupport@daikinapplied.com).

Daisy-Chain Connection Establish a physical connection from the remote user interface to the MicroTech unit controller.

  1.  Connect a twisted pair wire to the CE + and CE – pins of each unit controller and remote user interface (see Figure 4 and Figure 5).
  2. Daisy-chain up to eight MicroTech unit controllers to a single remote user interface. See Figure 5 for wiring details. Note the wire size and distance limitations provided in Table 1.
  3. Cycle power to each MicroTech unit controller once the wiring of the remote user interface is complete.
    NOTE: Downloading and communication using the daisy chain connection may be slower than for the RJ45 (Ethernet) direct connection.

Table 1: Wiring Specifications

Koneksyon otobis la CE+, CE-, not interchangeable
Tèminal 2-screw connector
Max. longè 1000 pye (305 m)
Kalite kab
Wiring distance up to 500 ft Twisted pair, shielded cable 16 AWG
Wiring distance between 500 – 1000 ft Twisted pair, shielded cable 14 AWG
Distans fil elektrik plis pase 1000 pye Not currently supported. Contact the appropriate Daikin Applied Technical Response Center for assistance.

DAIKIN-1005-7-Micro-Tech-Unit-Controller-Remote-FIG- (5)

DAIKIN-1005-7-Micro-Tech-Unit-Controller-Remote-FIG- (6)

Koneksyon dirèk

  1. Ou ka konekte koòdone itilizatè a distans lan dirèkteman ak yon sèl kontwolè inite MicroTech atravè yon koneksyon RJ45 (Ethernet) estanda.

Pwosedi

  1. Locate the connector location as shown in Figure 6
  2. Follow Figure 6 for connection details. Note the distance limitations provided.
  3. Cycle power to the unit(s) once the wiring of the remote user interface is complete.
  4. REMAK: Kontwolè inite a bay kouran. Si ou bezwen yon ekipman pou kouran 24V apa, tanpri kontakte Sant Repons Teknik Daikin Applied Air nan 800-432-1342 (AAHTechSupport@daikinapplied. com) or the Chiller Technical Response Center at 800-432-1342 (CHLTechSupport@daikinapplied.com).

DAIKIN-1005-7-Micro-Tech-Unit-Controller-Remote-FIG- (7)

Operasyon

  • Sèvi ak Entèfas Itilizatè a Distans

Karakteristik Materyèl

  • Klavye/ekran koòdone itilizatè a distans lan gen ladan l yon ekran 8 liy pa 30 karaktè, yon wou navigasyon "pouse epi woule", ak twa bouton: Alam, Meni, ak Retounen (Figi 7).
  • Turn the navigation wheel clockwise (right) or counterclockwise (left) to navigate between lines on a screen and also to increase and decrease changeable values when editing. Press down on the wheel to use it as an Enter button.
  • Press the Back button to display the previous page.
  • Press the Home button to return to the main screen from the current page.
  • Press the Alarm button to view meni Lis Alam yo.

Karakteristik klavye/ekspozisyon

  • The first line on each page includes the page title and the line number to which the cursor is currently “pointing.” The line numbers are X/Y to indicate line number X of a total of Y lines for that page. The left most position of the title line includes an “up” arrow to indicate there are pages “above” the currently displayed items, a “down” arrow to indicate there are pages “below” the currently displayed items or an “up/down” arrow to indicate there are pages “above and below” the currently displayed page. Each line on a page can contain status-only information or include changeable data fields. When a line contains status-only information and the cursor is on that line, all but the value field of that line is highlighted meaning the text is white with a black box around it. When the line contains a changeable value and the cursor is at that line, the entire line is highlighted.
  • Chak liy sou yon paj kapab defini tou kòm yon liy "sote", sa vle di lè w peze wou navigasyon an, sa ap lakòz yon "sote" nan yon nouvo paj. Yon flèch parèt byen lwen adwat liy lan pou endike ke se yon liy "sote" epi tout liy lan make lè kurseur a sou liy sa a.
  • REMAK: Se sèlman meni ak atik ki aplikab pou konfigirasyon inite espesifik la ki ap parèt.

DAIKIN-1005-7-Micro-Tech-Unit-Controller-Remote-FIG- (8)

Alam
The Alarm Details Menu includes active alarm and alarm
log information. See Figure 8 for an exampyon alam aktif. Gade tou Manyèl Operasyon kontwolè inite MicroTech ki apwopriye a (www.DaikinApplied.com) pou opsyon alam ki disponib yo.

DAIKIN-1005-7-Micro-Tech-Unit-Controller-Remote-FIG- (9)

Modpas
Unit controller menu functions have different levels of accessibility. The ability to view ak/oswa chanje paramèt yo depann de nivo aksè itilizatè a ak modpas ki antre a. Gen kat nivo aksè modpas:

  1. 1. Pa gen modpas.
    2. Nivo 2. Pi wo nivo aksè a. San antre yon modpas, itilizatè a gen aksè sèlman a atik meni estati debaz yo. Antre modpas Nivo 2 a (6363) pèmèt yon aksè menm jan ak Nivo 4 la avèk adisyon Meni Konfigirasyon Inite a.
    3. Nivo 4. Antre modpas Nivo 4 la (2526) pèmèt yon aksè menm jan ak Nivo 6 la avèk adisyon gwoup Meni Inite Komisyon an, Kontwòl Manyèl la, ak Meni Sèvis yo.
    4. Nivo 6. Antre modpas Nivo 6 la (5321) pèmèt aksè nan Meni Lis Alam yo, Meni Rapid la, ak ViewGwoup /Mete meni inite yo.
  2. Alarms can be acknowledged without entering a
    modpas.
    Accessing The Password Page
    The main password page is displayed when the remote user
    interface display (HMI) is first accessed.
    1. Peze bouton Kay la.
    2. Press the Back button multiple times, or if the keypad/
    display has been idle longer than the Password Timeout
    (default 10 minutes).
    The main password page provides access to enter a
    password, access the Quick Menu, view the current Unit
    State, access the alarm lists or view enfòmasyon sou
    unit (Figure 9).

DAIKIN-1005-7-Micro-Tech-Unit-Controller-Remote-FIG- (10)

  • Manyèl Operasyon kontwolè inite MicroTech la (www.DaikinApplied.com) bay plis enfòmasyon sou modpas yo, tankou kijan pou itilize paramèt Navigasyon ak Mòd Modifikasyon yo pou jwenn aksè epi modifye modpas yo.

Konfigirasyon

  • The following section describes how to set up the HMI so that it can be used to display, configure, or change unit parameters.
  • Refer to the applicable MicroTech unit controller Operation
  • Manual for a detailed description of chiller or rooftop sequence of operation and keypad menu structure when configuring the unit via the remote user interface (www.DaikinApplied.com).
  • REMAK: Pou chanje ant inite yo, peze bouton Retounen an pandan senk segonn pou retounen nan ekran prensipal la.

Customize User Preferences

  1.  Turn power on to the unit controller(s). Power to the remote user interface is provided automatically from the MicroTech unit controller(s) through the RJ45 (Ethernet) direct connection.
  2.  The main screen with HMI Settings and Controller List appears (Figure 10). Use the HMI Settings screen to change options for backlight color, backlight turn off time, contrast, and brightness.
  3. NOTE: The main screen can be accessed at any time by pressing the Home button for five seconds.
  4. Press the navigation wheel to select the HMI Settings menu, if desired.

DAIKIN-1005-7-Micro-Tech-Unit-Controller-Remote-FIG- (11)

Senkronize ak Kontwolè Inite MicroTech la

1. Peze wou navigasyon an pou chwazi ekran Lis Kontwolè a (Figi 11).

  • The Controller List automatically updates each time the remote user interface is powered up so that information is synchronized from the main unit controller.
  • The Controller List screen displays the unit controller(s) connected to the remote user interface. This screen allows the user to select between units, if more than one unit is connected to the remote user interface

DAIKIN-1005-7-Micro-Tech-Unit-Controller-Remote-FIG- (12)

REMAK: Yon sèl inite parèt sou ekran an kòm yon posiblite seleksyon si se yon sèl kontwolè inite ki konekte ak koòdone itilizatè a distans lan.

  • Turn the navigation wheel clockwise and then press down to select the desired unit.
  • The Information screen appears as the remote user interface performs a download sequence to import the necessary information from the main unit controller. A status bar appears on the Downloading the Objects screen to indicate that the download is in process (Figure 12).
  • NOTE: Refer to the Troubleshooting section if the remote user interface appears to “freeze” during the initial downloading sequence.

DAIKIN-1005-7-Micro-Tech-Unit-Controller-Remote-FIG- (13)

  1. Once the first unit has been downloaded, select the next unit controller, if applicable. The download process is required for each unit controller connected to the remote user interface.
  2.  Press the Home button for five seconds to return to the main screen.
  3. NOTE: The Downloading the Objects sequence generally takes a minute or less when direct-connecting to a single unit. However, the downloading sequence takes longer when using the daisy-chain connection. When the download sequence is complete, the
  4. Main screen of the unit controller appears on the remote user interface. At this point, the remote user interface and unit controller are synchronized.
  5.  Access and adjust the same parameters that are available via the unit controller keypad/display. Refer to the applicable MicroTech unit controller Operation Manual for the keypad menu structure and detailed description the unit controller sequence of operation (www.DaikinApplied.com).

Pwosedi Mizajou Firmware

  1. Follow these steps to update the remote user interface (HMI) firmware (.bin) file.
  2. NOTE: The upgrade procedure requires the use of an SD memory card no larger than 8GB with a FAT32 file fòma sistèm lan.
  3. NOTE: A field update is not possible on units with v1.07 firmware. Contact the Daikin Applied Air Technical Response Center at 800-432-1342 (AAHTechSupport@daikinapplied.com) or the Chiller Technical Response Center at (800) 432- 1342 (CHLTechSupport@daikinapplied.com) pou asistans.

Depanaj

  1. This section contains helpful information, frequently asked questions, and other tips related to the remote user interface.

Tablo 2: Gid depanaj

Pwoblèm Solisyon
 

 

During the initial download sequence, the keypad/display appears to

freeze up and a “Loading….. Lost

Connection” message appears.

The remote user interface is stuck in the downloading sequence due to incompatibility with v1.07 application software. The remote user interface must be updated to v10.22 or newer application software. Contact Daikin Applied Air Technical Response

at 800-432-1342 pou plis enstriksyon.

 

The remote user interface has been connected to the

MicroTech unit controller but the display remains blank after power-up.

 

Verify that the unit controller has power. Check wiring from

the unit controller to the remote user interface. Note that inputs and outputs are polarity-sensitive.

The remote user interface is experiencing a loss of communication. The site may have “dirty power” or electrical noise causing loss of

communication. See below for further instruction.

  1. Access the Power Bus menu on the MicroTech unit controller by the following keypad menu path: service menu/HMI setup/PBusPwrSply=ON (default). See Figure 13.
  2.  Set the default Power Bus supply.
  3. For the first and last units on the daisy-chain trunk, leave the Power Bus supply at the default of ON.
  4. For all other units within the daisy chain trunk, set the Power Bus supply to the OFF position.

DAIKIN-1005-7-Micro-Tech-Unit-Controller-Remote-FIG- (14)

Konsèy itil
Teknisyen sèvis yo souvan twouve li pratik pou gen de klavye/ekran konekte ak yon sèl kontwolè inite. Sèvi ak yon konfigirasyon ekran divize fè li posib pou view multiple menu items at the same time during start-up and also for diagnostic purposes. → Simply hook up the first remote user interface with an RJ45 direct connection, and then use a two-wire twisted  pair cable to connect to the second keypad/display.

Istwa revizyon

Revizyon Dat Chanjman
IM 1005 Janvye 2010 Premye lage
IM 1005-1 Septanm 2010 Added Daikin Trailblazer® chiller model AGZ-D
IM 1005-2 Mas 2012 Added Rebel® packaged rooftop model DPS. Updated Figure 3 with labels and connector cables.
IM 1005-3 Novanm 2016 Added models AWV Pathfinder® chiller and AGZ-E Trailblazer® chiller, added RJ45 direct connection option, corrected bus wiring distance limitations, Troubleshooting section, Daikin branding and formatting updates
IM 1005-4 Janvye 2018 Te ajoute modèl chiller WME & WWV.
IM 1005-5 Out 2019 Updated connections
IM 1005-6 jen 2023 Mizajou sou mak ak lòt fòma.
IM 1005-7 Jiyè 2025 Updated contact information, added Daikin Trailblazer® chiller model AMZ, and removed model lists from front cover.

 

Daikin Applied Fòmasyon ak Devlopman
Now that you have invested in modern, efficient Daikin Applied equipment, its care should be a high priority. For training information on all Daikin Applied HVAC products, please visit us at www. DaikinApplied.com and click on Training, or call 540-248-9646 epi mande Depatman Fòmasyon an.

Garanti
Tout ekipman Daikin Applied yo vann daprè tèm ak kondisyon estanda lavant li yo, ki gen ladan Garanti Limite pou Pwodwi. Konsilte reprezantan lokal Daikin Applied ou a pou detay sou garanti. Pou jwenn reprezantan lokal Daikin Applied ou a, ale sou www.DaikinApplied.com.

Sèvis Aftermarket
Pou jwenn biwo pyès lokal ou a, vizite www.DaikinApplied.com oswa rele 800-37PARTS (800-377-2787). Pou jwenn biwo sèvis lokal ou a, vizite www.DaikinApplied.com oswa rele 800-432-1342. Dokiman sa a gen enfòmasyon ki pi aktyèl sou pwodwi apati de enprime sa a. Pou enfòmasyon ki pi ajou sou pwodwi a, tanpri ale nan www.DaikinApplied.com.Products manufactured in an ISO Certified Facility.

FAQ

Q: How many units can the remote user interface handle?

A: The remote user interface can handle up to eight units per interface.

Is a separate 24V power supply necessary for direct connection?

Non, se kontwolè inite MicroTech la ki bay kouran an.

What type of cable is recommended for daisy-chain connection?

Daikin Applied generally recommends using twisted pair, 16 AWG shielded cable up to 500 ft and 14 AWG from 500 to 1000 ft. Contact the appropriate Technical Response Center for applications requiring longer distances.

Kouman mwen ka konnen si oswa ki lè mwen bezwen mete ajou firmwèr entèfas itilizatè a distans (HMI) an? files?

If the remote user interface seems to freeze during initial download process If wiring has been confirmed (inputs and outputs are polarity sensitive) and HMI is not responding See Firmware Upgrade Procedure section for details.

E si mwen vle mete ajou firmwèr kontwolè inite MicroTech la?
Contact either the Daikin Applied Air Technical Response Center at 800-432-1342 (AAHTechSupport@daikinapplied.com) or the Chiller Technical Response Center at 800-432-1342 (CHLTechSupport@daikinapplied.com) pou asistans.

Dokiman / Resous

DAIKIN 1005-7 MicroTech Unit Controller Remote User Interface [pdfManyèl Enstriksyon
1005-7 MicroTech Unit Controller Remote User Interface, 1005-7, MicroTech Unit Controller Remote User Interface, Controller Remote User Interface, Remote User Interface, User Interface

Referans

Kite yon kòmantè

Adrès imel ou p ap pibliye. Jaden obligatwa yo make *