CyberPower Personal Linux Software

Kòmanse
Non
pwrstat Zouti lòd eta pouvwa UPS la.
Rezime

Deskripsyon
pwrstat is an interface in PowerPaneI for Linux which allows users to receive UPS status and configure UPS settings.
Type the following command to list the manual: man pwrstat
Opsyon
Paramèt pwrstat yo, fonksyon yo, ak ansyen anampyo dekri anba a:


Nòt 1
Agiman sa yo ta dwe swiv -pwrfail.

Nòt 2
Agiman sa yo ta dwe swiv -lowbatt.

Nòt 3
Agiman sa yo ta dwe swiv -cloud.

Nòt 4
- Paramèt yo nan -pwrfail ak -lowbatt bezwen yo dwe mete poukont yo.
- Both the shell scripts pwrstatd-lowbatt.sh and pwrstatd-powerfail.sh will be copied to Jetc during the installation procedure.
- The parameter —cmd can be any shell script in the system, and it should be run as root to modify the settings.
- The default system settings for -pwrfail and -lowbatt
Examples pou Konfigirasyon Opsyon pwrstat
- Example 1: Configure the setting when a power failure event occurs. pwrstat -pwrfail -delay 60 -active on -cmd/etc/pwrstatd-powerfail.sh -duration 60 -shutdown on In the setting above, it will take 60 seconds to run a shell script named pwrstatd-powerfail.sh in the directory /etc, and the system will be shut down after a power failure event occurs for 60 seconds.
- Example 2: Configure the setting when the low battery event occurs. pwrstat-lowbatt -runtime -runtime -capacity -capacity – active on -cmd /etc/pwrstatd-lowbatt.sh -duration 1 -shutdown on In the setting above, it will take 1 minute to run a shell script named pwrstatd-lowbatt.sh in the directory /etc, and the system will be shut down when either the remaining runtime is less than 300 seconds, or the battery capacity is lower than 35%.
- Example 3a: Konfigure koneksyon an ak PowerPanel Cloud.
pwrstat -cloud -active sou -kont example@cyberpower.com - modpas pas123
Assuming PowerPanel Cloud account/password: example@cyberpower.com / pass123. In the setting above, the connection to PowerPanel Cloud will be activated when users correctly enter their PowerPanel Cloud account and password. - Example 3b: Verifye koneksyon ak PowerPanel Cloud.
pwrstat -verify
Pou verifye si kont ak modpas yo kòrèk, antre kòmandman an pi wo a.
Gen twa rezilta, ki dekri anba a:
- Lè tou de kont la ak modpas yo kòrèk, sistèm lan pral montre Verify avèk siksè.
- Lè swa kont la oswa modpas la kòrèk, sistèm lan pral montre Verify failed.
- When a network issue exists, the system will show Connect failed
Paj demon an
Non
pwrstatd Demon eta pouvwa UPS la.
Deskripsyon
pwrstatd is the daemon of PowerPanel for Linux, which runs immediately when the system starts up and communicates with the UPS.
Type the following command to list the operations and the configuration files of the daemon: man pwrstatd
Operasyon demon an
Kòmandman pou opere demon pwrstatd ak fonksyon yo dekri anba a:

Konfigirasyon Files nan Daemon an
Konfigirasyon an fileyo ak fonksyon yo dekri anba a:

Nòt 5
pwrstatd.conf ka modifye lè w itilize nenpòt editè tèks. Pou kòmanse modifye konfigirasyon an file, type the following command as root: vi/etc/pwrstatd.conf *
Take the text editor, vi, for example.
Chanjman yo modifye nan editè tèks la pral pran efè apre rekòmanse pwrstatd. Pou rekòmanse demon an, tape lòd sa a: /etc/init.d/pwrstatd rekòmanse
Nòt 6
To send the e-mail content in /etc/pwrstatd-email.sh, it is necessary to set ENABLE_EMAIL=yes and enter both the RECEIPT_ADDRESS and the SENDER_ADDRESS correctly in /etc/pwrstatd-lowbatt.sh or /etc/pwrstatd- powerfail.sh. For details about installing the e-mail package in Ubuntu, please refer to troubleshooting 6.
Jounal Evènman demon an
The event logs of the pwrstatd daemon are located in the directory: /var/log. The file yo te rele pwrstatd.log anrejistre tout evènman pouvwa yo.
Tcheke Paramèt Daemon
Type the following command to show the configuration of pwrstat:
Anba a se ansyen anample for daemon configuration:

Aksyon pou echèk kouran:
Aksyon pou batri ki ba:

Siveyans Estati UPS
Type the following command to show UPS properties and the current status:
pwrstat -status
Anba a se yon ansyenample pou modèl UPS, CP585:

Nòt 7
Kèk nan atik ki nan lis pi wo a pral parèt sèlman lè modèl UPS la sipòte fonksyon ki gen rapò yo.
CYBERPOWER POWERPANEL
Tanpri vizite https://www.cyberpower.com/content/software/eula/to see the complete EULA terms.
Dokiman / Resous
![]() | Personal Linux Software |
Referans
- cp.mcafee.com/d/2DRPoQ86Qm6jhO-OOVt4TsSepd79EVuKqerCNP9EVd7bOb8USepd79EVuKqekPqdXIzDD4Snzq1foR1lBG637bCXbkc6end-zHO5DT-LObzXXwW_nKnjjhjVBBdBV5zG8FHnjlKejVkffGhBrwqrhdFECXYDtNwse7cFL6XCM0lyN3UHlcv7BPvDOxRysLw2H5y7NmGo-fbCQQPhPtMQsCMmd96y09Q-9EDEq81Locp.mcafee.com
- pwrstatd-email.shpwrstatd-email.sh
- pwrstatd-lowbatt.shpwrstatd-lowbatt.sh
- pwrstatd-powerfail.shpwrstatd-powerfail.sh
- rpmfind.net/rpmfind.net
- sourceforge.net/sourceforge.net
- cyberpower.comwww.cyberpower.com
- cyberpower.com/content/software/eula/www.cyberpower.com
- Manyèl itilizatèmanual.tools