EARU EARU1036

EARU 32A Circuit Breaker Instruction Manual

Model: EARU1036

1. Pwodwi souview

The EARU 32A Circuit Breaker (Model EARU1036) is an Advanced Protection Suite (APS) designed to safeguard electrical circuits, appliances, and personnel. It integrates multiple protection functions into a single device, ensuring comprehensive safety and reliability for various electrical installations.

Karakteristik kle:

2. Enfòmasyon sou Sekirite

Please read all safety instructions carefully before installing, operating, or maintaining this device. Failure to follow these instructions may result in electrical shock, fire, serious injury, or death.

3. Product Components and Wiring Diagram

Familiarize yourself with the main components and the correct wiring configuration of the EARU 32A Circuit Breaker.

Detaye view of EARU 32A Circuit Breaker components and wiring diagram

Imaj 1: Detaye view of the EARU 32A Circuit Breaker, highlighting its terminals, operating handle, test button, wiring diagram, surge protection indicator, reset button, fastening screws, and flame retardant housing. The diagram shows connections for Line (L), Neutral (N), and Protective Earth (PE). It emphasizes that the circuit must be wired and grounded correctly to ensure proper operation and protection.

Product Dimensions and Parameters

Dimensions and key parameters of EARU 32A Circuit Breaker

Imaj 2: This image displays the physical dimensions of the EARU 32A Circuit Breaker (94mm height, 71mm width, 45mm depth) and lists key product parameters such as Product Series (EADZ47L-32SVP), Rated Voltage (AC230V), Mechanical Lifespan (20000 cycles), Compliance Standard (IEC61009-1), Rated Residual Operating Current (30mA), Poles (2P+PE/4Pole), Product Certification (CE), and Breaking Capacity (6000A). It also highlights advanced features like overload, short circuit, lightning, leakage, over-undervoltage protection, smart reset, and real-time monitoring.

4. Enstalasyon

The EARU 32A Circuit Breaker is designed for DIN-rail mounting. Ensure the installation environment is dry, well-ventilated, and free from corrosive substances.

Etap enstalasyon:

  1. Montaj: Securely attach the circuit breaker to a standard DIN rail in your electrical panel.
  2. Koneksyon fil elektrik: Gade Imaj 1 for the wiring diagram. Connect the incoming Line (L) and Neutral (N) wires to the top terminals and the outgoing load wires to the bottom terminals. Ensure the Protective Earth (PE) is correctly connected.
  3. Sereman Tèminal: Use appropriate tools to tighten all fastening screws on the terminals to ensure secure electrical contact and prevent loose connections, which can cause overheating or arcing.
  4. Verifikasyon: Double-check all wiring connections for correctness and tightness before restoring power.
EARU Circuit Breaker installed in an electrical panel

Imaj 3: An EARU Circuit Breaker installed on a DIN rail within an electrical panel, demonstrating a typical installation scenario with connected wiring.

5. Operasyon Enstriksyon

Basic Operation and Leakage Protection Test

Follow these steps for normal operation and to periodically test the leakage protection function of your circuit breaker.

Instructions for powering on and testing leakage protection

Imaj 4: This image illustrates the basic operating instructions. Etap 1: To power on, pull up the operating handle (red switch) and ensure the 'R' button is protruding, indicating a power-on state. Etap 2: If the handle jumps down automatically and the 'R' button bounces, it signifies a normal power-off state. Etap 3: If the 'R' button is pressed and the handle does not jump down, it indicates a problem. Etap 4: After a successful test or reset, the device returns to a powered-on state.

Detailed instructions for leakage protection device inspection

Imaj 5: Detailed instructions for inspecting the leakage protection device. Etap 1: With the operating handle pulled up and the 'R' button not protruding (power-on state), press the 'Test' key to test the leakage protection device. Etap 2: If the handle jumps down automatically and the 'R' button bounces, the device is in a power-off state, indicating the leakage protection device is functioning normally. Etap 3: If the 'Test' switch is pressed and the handle does not jump down, and the 'R' button does not automatically pop up, the device is in an energized state, indicating a problem with the leakage protection device, and it cannot provide protection. A new leakage device needs to be replaced. Etap 4: After a normal inspection (handle automatically jumps down, 'R' button automatically pops up), the device is in a power-off state. Press the 'R' button that just popped up, and then pull up the operating handle to power on the appliance normally.

Parameter Setting (Adjustable Voltage and Current Protector)

The EARU Circuit Breaker allows for adjustment of various protection parameters. The following video demonstrates how to set these parameters.

Videyo 1: This video demonstrates how to adjust the protection parameters on an EARU Adjustable Voltage and Current Protector. It shows setting the overvoltage (P-1, range 240-300V), undervoltage (P-2, range 140-200V), overcurrent (P-3, range 1A-40A/63A/80A), reset/start delay (P-4, range 1s-300s), and relay recovery delay (P-5, range 1s-300s) settings. The video also shows the overcurrent recovery delay (P-6, range 1s-300s). This process involves pressing the 'SET' button to enter programming mode and using the up/down arrows to adjust values.

6. Antretyen

Regular maintenance ensures the longevity and reliable operation of your EARU Circuit Breaker.

NAN. Depanaj

If you encounter issues with your EARU Circuit Breaker, refer to the following common troubleshooting steps. For complex problems, contact a qualified electrician.

PwoblèmKòz posibSolisyon
Aparèy pa limenIncorrect wiring; No input power; Device faultCheck wiring connections (L, N, PE); Verify main power supply; If wiring and power are correct, device may be faulty and require replacement.
Frequent tripping (Over-Voltage/Anba-Voltage)Unstable power supply; Incorrect voltaganviwònman yoTcheke liy k ap rantre voltage stability; Adjust over/under voltage settings (refer to Parameter Setting video) if necessary, ensuring they are within safe operating limits for your appliances.
Frequent tripping (Overload/Short Circuit)Excessive load; Short circuit in connected appliance/wiringReduce connected load; Inspect appliances and wiring for short circuits; Adjust overcurrent settings (refer to Parameter Setting video) if appropriate for the load, but do not exceed device rating.
Frequent tripping (Earth Leakage/Electric Shock)Ground fault in connected appliance/wiring; Device faultInspect appliances and wiring for ground faults; Perform leakage protection test (refer to Operating Instructions); If test fails and no external fault is found, device may be faulty.
Leakage protection test fails (handle does not jump down)Leakage protection mechanism faultThe leakage protection device is faulty and cannot provide protection. It must be replaced immediately.

8. Espesifikasyon teknik

Key technical specifications for the EARU 32A Circuit Breaker, Model EARU1036.

SpesifikasyonValè
MakEARU
Nimewo ModèlEARU1036
Rating aktyèl30 Miliamps (Residual Operating Current)
Voltage230 Volts
Wattage10000 Watts
Dimansyon pwodwi (D x W x H)20P x 12W x 12H santimèt
Kalite Circuit BreakerRCBO, RCCB, ELCB, MCB, Surge Protector
Kalite aliyeDIN Rail mòn
Kantite poto6 (Implied from 2P+PE/4Pole in image, actual product is 2-pole with earth protection)
Pwa atik450 g
Sous pouvwaAC Powered
Konpozan ki enkli2 IN ONE (Circuit Breaker)
Peyi orijinpeyi Zend
Dat Premye Disponib10 Novanm 2022

9. Garanti ak sipò

The EARU 32A Circuit Breaker comes with a 2-year warranty, backed by GE-authorized service. For warranty claims, technical assistance, or product support, please contact your retailer or the authorized service center.

Manifakti: EARU

Vandè: GE INDIA INC.

Tanpri konsève prèv acha ou a pou validasyon garanti a.

Dokiman ki gen rapò - EARU1036

Preview EARU EAL-2 Din Rail Circuit Breaker Instruction Manual
Instruction manual for the EARU EAL-2 series din rail circuit breaker, detailing its features, safety instructions, and product parameters for AC 2P 230V 4P 400V A Type RCBO RCCB MCB electronic residual current circuit breakers.
Preview EARU EAPDX-40/63 Series Adjustable VoltagManyèl Itilizatè Pwotektè Kouran ak E
User manual for the EARU EAPDX-40/63 Series Adjustable Voltage & Current Protector, detailing specifications, features, and operation for electrical protection. Includes setup instructions and parameter configuration.
Preview EARU EAMPManyèl Itilizatè Pwotektè Enèji Entelijan WiFi Seri DW-TY-63 | Volimtage, Kouran, Pwoteksyon kont flit
Manyèl itilizatè konplè pou EARU E aAMPPwotektè Enèji Entelijan WiFi Seri DW-TY-63. Aprann plis sou enstalasyon, karakteristik, espesifikasyon teknik, kontwòl aplikasyon ak depanaj pou vol.tage, kouran, ak pwoteksyon kont flit.
Preview EARU EAMPManyèl Itilizatè Pwotektè Enèji Entelijan WiFi Seri DW-TY-63 la
Manyèl itilizatè konplè pou EARU E aAMPDW-TY-63 series WiFi Smart Energy Protector, detailing features, installation, app connection, parameter settings, and troubleshooting. Covers over/under voltage, over current, leakage protection, energy monitoring, and remote control.
Preview Earu EAMPManyèl Itilizatè Pwotektè Enèji Entelijan WiFi Seri DW-TY-63 la
Manyèl itilizatè ak espesifikasyon teknik pou Earu E aAMPPwotektè Enèji Entelijan WiFi Seri DW-TY-63 la, ki detaye enstalasyon, koneksyon aplikasyon an, konfigirasyon paramèt yo, ak karakteristik sekirite yo.
Preview EARU-X6/8 Metal LED Indicator Light Instruction Manual
User manual for EARU-X6/8 series Metal LED Indicator Lights, detailing safety instructions, warnings, and product description for reliable status indication in industrial and traffic applications.