1. Entwodiksyon
The EARU Electric Single Phase Energy Meter (Model EARU-1006) is designed for accurate monitoring of electrical parameters in single-phase 220V, 80A systems. It provides real-time data for voltage (V), current (A), power (W), power factor (PF), frequency (Hz), and kilowatt-hour (kWh) consumption. This device assists in understanding energy usage and identifying potential inefficiencies in your electrical system.
2. Enfòmasyon sou Sekirite
- Enstalasyon an dwe fèt pa yon elektrisyen kalifye, dapre kòd ak règleman elektrik lokal yo.
- Ensure the main power supply is disconnected before installation or maintenance to prevent electric shock.
- Pa sèvi ak aparèy la si li sanble domaje.
- This device is designed for indoor use in a dry environment. Avoid exposure to moisture or extreme temperatures.
- The maximum current rating is 80A. Do not exceed this limit.
3. Pwodwi souview
The EARU-1006 energy meter features a clear LCD display that shows various electrical parameters simultaneously. It is designed for DIN rail mounting, allowing for easy integration into standard electrical distribution boards.

Figi 1: Devan view of the EARU Electric Single Phase Energy Meter, showing the LCD display with various electrical readings.

Figi 2: Detaye view of the LCD display, illustrating the layout of voltage, current, power, frequency, power factor, and kWh readings.
4. Pake kontni
Pake a anjeneral gen ladan:
- 1 x EARU Electric Single Phase Energy Meter (Model EARU-1006)
5. Espesifikasyon

Figure 3: Technical data table providing detailed specifications of the energy meter.
| Paramèt | Valè |
|---|---|
| Mak | EARU |
| Modèl | EARU-1006 |
| Rated Voltage | AC110V/220V (230 Volts) |
| Rated aktyèl | 80A |
| Frekans | 50/60Hz |
| Presizyon Mezi | ±1% / Class 1 |
| Konsomasyon pouvwa | <2W |
| Enstalasyon | 35mm DIN Rail |
| Tanperati travay | -10°C pou +55°C |
| Tanperati Depo | -40°C pou +70°C |
| Travay imidite | 5% a 95% RH |
| Kalite ekspozisyon | LCD |
| Max kWh Record | 999999 kWh |
| Dimansyon pwodwi | 10 x 5 x 10 cm |
| Pwa atik | 450 g |

Figure 4: Dimensional drawing of the energy meter, showing measurements in both millimeters and inches.
6. Enstalasyon ak Enstalasyon
Enpòtan: Asire w ke tout pouvwa a dekonekte anvan ou kontinye ak enstalasyon an.
- Montaj: The EARU-1006 is designed for 35mm DIN rail mounting. Snap the meter onto the DIN rail securely within your electrical panel.
- Fil elektrik: Refer to the wiring diagram below for correct connection. This is a single-phase, 2-wire direct connection meter.
- Connect the Live (L) input wire to the designated 'L In' terminal.
- Connect the Neutral (N) input wire to the designated 'N In' terminal.
- Connect the Live (L) output wire to the designated 'L Out' terminal.
- Connect the Neutral (N) output wire to the designated 'N Out' terminal.
- Pouvwa sou: Once all connections are secure and verified, restore power to the circuit. The LCD display should illuminate and begin showing readings.

Figure 5: Wiring diagram illustrating the correct connections for the single-phase energy meter.
7. Operasyon Enstriksyon
The energy meter operates automatically once powered on. The LCD display continuously cycles through or shows multiple parameters simultaneously.
- Reading Parameters: The display shows Voltage (V), Current (A), Power (W), Power Factor (PF), Frequency (Hz), and Kilowatt-hour (kWh).
- kWh Reading: The meter records total kWh consumption. This reading is permanent and accumulates over time.
- kWh Reset: The meter features a manual reset function for the kWh reading. Consult the device's physical buttons or specific instructions on the meter itself for the reset procedure. Typically, a long press on a designated button (if present) will reset the temporary kWh value. The total kWh value is usually non-resettable.
8. Antretyen
- Netwayaj: Use a soft, dry cloth to clean the meter's exterior. Do not use abrasive cleaners or solvents.
- Enspeksyon: Periodically inspect the wiring connections to ensure they are tight and free from corrosion.
- Anviwònman: Asire w ke anviwònman operasyon an rete nan limit tanperati ak imidite espesifye yo.
NAN. Depanaj
| Pwoblèm | Kòz posib | Solisyon |
|---|---|---|
| Ekspozisyon an vid | Pa gen ekipman pou kouran; Fil elektrik ki pa kòrèk | Check power connections and ensure power is supplied. Verify wiring against the diagram. |
| Lekti ki pa kòrèk | Incorrect wiring; Faulty connection | Double-check all wiring connections. Ensure wires are securely fastened. |
| kWh not accumulating | No load connected; Meter malfunction | Ensure there is an active electrical load connected through the meter. If problem persists, contact support. |
10. Garanti ak sipò
The EARU Electric Single Phase Energy Meter (Model EARU-1006) typically comes with a 1-year warranty from the date of purchase. Please retain your purchase receipt for warranty claims.
For technical support, troubleshooting assistance, or warranty inquiries, please contact your retailer or the manufacturer directly. Refer to the product packaging or manufacturer's websit pou detay kontak.