1. Entwodiksyon
This manual provides essential information for the safe and effective use of the Wells 30 Amp 240 Volt Fuse. These fuses are designed to provide reliable overcurrent protection for electrical systems, specifically compatible with Wells Disconnect Boxes, and suitable for various applications including AC units, HVAC systems, and general home appliances. Please read this manual thoroughly before installation or replacement.
2. Enfòmasyon sou Sekirite
WARNING: Risk of electric shock. Always disconnect power before working with electrical components. Installation and replacement should only be performed by qualified personnel or individuals with appropriate electrical knowledge. Failure to follow these instructions may result in serious injury or death.
- Ensure the main power supply to the circuit is turned OFF before handling fuses.
- Pa janm sèvi ak yon fusible ki gen yon pi wo ampevalyasyon vòltaj pase sa ki espesifye pou sikwi a.
- Always replace a blown fuse with a fuse of the identical type and rating.
- pa kontoune oswa tamper with fuses.
3. Pwodwi souview
The Wells 30 Amp 240 Volt Fuse is a UL Listed, Class RK5, dual-element, time-delay fuse. It is constructed from high-quality copper and plastic materials, ensuring durability and consistent protection for your electrical devices.

Figure 1: Wells 30 Amp 240 Volt Fuses and Packaging

Figure 2: Key Features of Wells Fuses
4. Enstalasyon (Enstalasyon)
These fuses are designed for easy insertion into compatible disconnect boxes. Follow these steps for proper installation:
- Dekonekte pouvwa: Before beginning, ensure that the main power supply to the disconnect box or appliance is completely turned off at the circuit breaker or main service panel. Verify with a voltage tèsteur.
- Jwenn pòt-fizib la: Open the disconnect box and identify the fuse holders.
- Remove Old Fuses (if applicable): If replacing existing fuses, carefully remove the old fuses from their holders.
- Insert New Fuses: Insert the Wells 30 Amp 240 Volt Fuses firmly into the designated fuse holders. Ensure they are seated correctly.
- Close Disconnect Box: Securely close the disconnect box cover.
- Retabli pouvwa: Remete ekipman pou kouran prensipal la.

Figure 3: Fuse Installed in a Disconnect Box (Note: Breakout box not included)
5. Prensip Operasyon yo
The Wells 30 Amp 240 Volt Fuse functions as a safety device designed to protect electrical circuits from damage caused by overcurrent. When the current flowing through the circuit exceeds 30 Amps for a sustained period (due to the time-delay feature), the fuse's internal element melts, breaking the circuit and preventing potential damage to appliances or wiring. This dual-element, time-delay design allows for temporary, harmless overloads (like motor startup surges) without blowing, while still providing protection against prolonged overcurrents.

Figure 4: Application in HVAC Systems
6. Antretyen
Fuses are generally maintenance-free components. However, periodic inspection is recommended:
- Enspeksyon vizyèl: Occasionally inspect the fuses for any visible signs of damage or discoloration.
- Ranplasman: If a fuse blows, it must be replaced. Always replace with a new Wells 30 Amp 240 Volt Fuse or an equivalent fuse with the exact same specifications (30A, 240V, Class RK5, time-delay).

Figure 5: Fuse Designed for Durability in Various Conditions
NAN. Depanaj
If an electrical circuit protected by this fuse loses power, follow these troubleshooting steps:
- Tcheke pouvwa: Ensure the main power supply to the circuit is on.
- Inspect Fuse: With the power OFF, open the disconnect box and visually inspect the fuse. A blown fuse may show a broken internal element or discoloration.
- Test Fuse (Optional): If visual inspection is inconclusive, a multimeter can be used to test for continuity across the fuse (with power OFF). A blown fuse will show no continuity.
- Ranplase Fuse: If the fuse is confirmed blown, replace it with a new Wells 30 Amp 240 Volt Fuse.
- Idantifye kòz la: If fuses blow frequently, it indicates an underlying electrical issue such as a short circuit, persistent overload, or faulty appliance. In such cases, consult a qualified electrician to diagnose and repair the problem before re-energizing the circuit.
8. Espesifikasyon
| Atribi | Spesifikasyon |
|---|---|
| Mak | Wells |
| AmpRating epòk | 30 Amp (30A) |
| Voltage Rating | 240 Volt (120VAC/240VAC) |
| Fuse Kalite | Class RK5, Dual Element, Time Delay |
| Sètifikasyon | UL ki nan lis 248 |
| Materyèl | Kwiv, Plastik |
| Dimansyon pwodwi (L x W x H) | 5.5 x 2.7 x 1 pous (pakè jeneral) |
| Individual Fuse Dimensions (Approx.) | 1.5 cm (0.59 inch) diameter, 5 cm (1.97 inch) length |
| Pwa pwodwi | 1.45 ounces (overall package) |
| Individual Fuse Weight (Approx.) | 0.04 liv |
| Nimewo Modèl | 7756643c-ffd7-43f3-8835-bca5b96b90a7 |

Figure 6: Wells Fuse Dimensions

Figure 7: Fuse Material and Weight
9. Garanti ak sipò
For specific warranty information regarding your Wells 30 Amp 240 Volt Fuses, please refer to the product packaging or visit the official Wells website. Wells Plumbing and Heating Supplies, INC, established in 2002 and headquartered in Chicago, Illinois, USA, is committed to providing quality HVAC solutions.
You can find more information about Wells products and support by visiting the Wells Store on Amazon.

Figure 8: Wells Brand Logo