Thank you for choosing the Westbrass E507DUS-07 Universal Fit 7-inch Diverter Tub Spout. This product is designed for durability and ease of installation, featuring a universal adapter system to accommodate various plumbing configurations. This manual provides essential information for safe installation, proper operation, and effective maintenance to ensure long-lasting performance.
Enfòmasyon enpòtan sou sekirite
- Toujou fèmen tiyo prensipal dlo a anvan ou kòmanse nenpòt travay plonbri.
- Mete ekipman pwoteksyon pèsonèl ki apwopriye, tankou linèt sekirite ak gan, pandan enstalasyon an.
- Asire w tout koneksyon yo byen sere pou anpeche flit. Pa sere yo twòp.
- Si ou pa sèten sou nenpòt etap, konsilte yon plonbye kalifye.
- Kenbe ti pati yo lwen timoun yo.
Kontni pake
Verifye ke tout konpozan yo prezan anvan ou kòmanse enstalasyon an:
- 7-inch Diverter Tub Spout (Satin Nickel)
- Teflon tep
- 1/2-inch Copper Pipe Fitting Adapter
- Brass Adapter (for 1/2-inch IPS or 3/4-inch IPS connections)
- Kle Egzagòn
- Extension Nipple (4-inch)

Image: The Westbrass E507DUS-07 tub spout with its diverter button, along with the included Teflon tape, 1/2-inch copper pipe fitting adapter, brass adapter, hex wrench, and 4-inch extension nipple.
Espesifikasyon
| Karakteristik | Detay |
|---|---|
| Mak | Westbrass |
| Non modèl | Universal Fit 7" Diverter Tub Spout, Zinc |
| Nimewo Modèl | E507DUS-07 |
| Materyèl | Zenk |
| Fini | Satin Nickel (Brushed) |
| Bekè rive | 7 pous |
| Kalite aliye | Mi mòn |
| Karakteristik espesyal | Leak Resistant, Diverter Function |
| Dimansyon pwodwi | 7"D x 2.5"W x 2.5"H |
| Pwa atik | 12 ons |
| UPC | 747028638821 |

Image: The Westbrass E507DUS-07 tub spout showing its overall length of 7 inches and a base length of 5 3/8 inches, alongside the included installation components.

Imaj: Anwo-anba view of the Westbrass E507DUS-07 tub spout, indicating a 7-inch length and 2.5-inch height, with the diverter button visible.
Enstalasyon ak Enstalasyon
Zouti obligatwa
- Kle reglabl oswa kle tiyo
- Screwdriver (if applicable for set screw)
- Teflon Tape (included)
- Kle Egzagòn (enkli)
Etap enstalasyon yo
The Westbrass E507DUS-07 tub spout is designed for universal fit, accommodating 1/2-inch copper, 1/2-inch IPS, or 3/4-inch IPS connections. Follow the steps below based on your existing plumbing.
- Fèmen rezèv dlo a: Locate and turn off the main water supply to your bathroom or entire house. Open a faucet to relieve pressure.
- Remove Old Tub Spout: If replacing an existing spout, loosen any set screws on the underside of the spout or unscrew it counter-clockwise from the wall pipe. Clean the area around the pipe.
- Determine Connection Type: Identify if your existing pipe is 1/2-inch copper, 1/2-inch Male Threaded (IPS), or 3/4-inch Male Threaded (IPS).
- Prepare Koneksyon an:
- For 1/2-inch Copper Pipe Connection: Ensure the copper pipe extends approximately 1-1/2 inches from the wall. Slide the 1/2-inch copper pipe fitting adapter onto the copper pipe. Secure it with the included hex wrench if there's a set screw.
- For 1/2-inch Male Threaded Connection (IPS): Apply Teflon tape to the threads of the existing 1/2-inch male threaded pipe. Thread the brass adapter onto the pipe.
- For 3/4-inch Male Threaded Connection (IPS): Apply Teflon tape to the threads of the existing 3/4-inch male threaded pipe.
- Install Extension Nipple (if needed): If your pipe does not extend far enough from the wall, use the included 4-inch extension nipple. Apply Teflon tape to the threads and connect it to your wall pipe or adapter.
- Attach Tub Spout:
- For Slip-On (Copper) or Adapter Connections: Slide the tub spout onto the pipe/adapter assembly until it is flush with the wall. Secure it by tightening the set screw on the underside of the spout with the hex wrench.
- For Threaded Connections (1/2-inch or 3/4-inch IPS): Carefully thread the tub spout onto the pipe/adapter assembly clockwise until it is hand-tight and properly aligned. Use a wrench for a final snug turn, but do not overtighten.
- Tès pou Fuites: Slowly turn the main water supply back on. Check all connections for leaks. If leaks occur, turn off the water, re-tighten connections, and re-test.

Image: Diagram illustrating four common installation scenarios for the Westbrass E507DUS-07 diverter tub spout, including 1/2-inch copper pipe, 1/2-inch male threaded, 3/4-inch male threaded, and 1/2-inch male pipe with threaded end connections, showing how the adapters and extension nipple are used.

Imaj: Yon eksplozyon view diagram of the Westbrass E507DUS-07 tub spout, detailing its internal components such as the body, rod, O-rings, knob, gate, insert pipe, bushings, and set screw, along with a parts list.
Enstriksyon Operasyon
The Westbrass E507DUS-07 tub spout features a diverter mechanism to switch water flow between the tub spout and a showerhead.
- For Tub Fill: Ensure the diverter knob on top of the spout is in the down position. Water will flow from the tub spout.
- For Shower: Pull the diverter knob upwards. This will redirect water flow to your showerhead. Push the knob down to return water flow to the tub spout.
Antretyen ak Swen
To maintain the finish and functionality of your tub spout, follow these guidelines:
- Netwayaj: Clean the spout regularly with a soft cloth and mild soap. Avoid abrasive cleaners, harsh chemicals, or scouring pads, as these can damage the satin nickel finish.
- Diverter Maintenance: If the diverter mechanism becomes stiff, a small amount of silicone-based lubricant can be applied to the moving parts.
- Prevansyon Leak: Periodically check for any signs of leaks around the base of the spout. Address any leaks promptly by re-tightening connections or replacing worn seals.
Depanaj
Seksyon sa a adrese pwoblèm komen ou ka rankontre ak bouch basen ou an.
| Pwoblèm | Kòz posib | Solisyon |
|---|---|---|
| Dlo ap koule nan baz tiyo a. | Loose connection, insufficient Teflon tape, or damaged O-ring/gasket. | Turn off water supply. Re-tighten the spout connection. If threaded, ensure adequate Teflon tape is applied. Inspect and replace any damaged O-rings or gaskets. |
| Diverter knob is stiff or not engaging. | Akimilasyon mineral oswa mank lubrifikasyon. | Clean the diverter mechanism. Apply a small amount of silicone-based lubricant to the moving parts of the diverter. |
| Water continues to drip from the tub spout when the diverter is engaged for the shower. | Worn diverter gate or O-rings inside the spout. | This indicates internal wear. Refer to the exploded view diagram (Image: Westbrass E507DUS-07 Exploded View Diagram) and consider replacing the internal gate or O-rings. If the issue persists, replacement of the spout may be necessary. |
| Spout does not fit existing plumbing. | Incorrect adapter used or incompatible pipe type. | Review the "Setup and Installation" section and the installation diagram (Image: Westbrass E507DUS-07 Installation Diagram) to ensure the correct adapter is selected for your pipe type (1/2-inch copper, 1/2-inch IPS, or 3/4-inch IPS). Confirm pipe extension from the wall is adequate. |
Garanti ak sipò
Westbrass products are manufactured to high-quality standards. For specific warranty information or technical support, please refer to the official Westbrass websit la oubyen kontakte depatman sèvis kliyan yo. Kenbe resi acha w la pou reklamasyon garanti.
For additional information and products, you may visit the Westbrass Storefront.