Thank you for choosing the Westbrass E507DUS-07 Universal Fit 7-inch Diverter Tub Spout. This product is designed for durability and ease of installation, featuring a universal adapter system to accommodate various plumbing configurations. This manual provides essential information for safe installation, proper operation, and effective maintenance to ensure long-lasting performance.

Enfòmasyon enpòtan sou sekirite

Kontni pake

Verifye ke tout konpozan yo prezan anvan ou kòmanse enstalasyon an:

Westbrass E507DUS-07 Tub Spout and Included Components

Image: The Westbrass E507DUS-07 tub spout with its diverter button, along with the included Teflon tape, 1/2-inch copper pipe fitting adapter, brass adapter, hex wrench, and 4-inch extension nipple.

Espesifikasyon

KarakteristikDetay
MakWestbrass
Non modèlUniversal Fit 7" Diverter Tub Spout, Zinc
Nimewo ModèlE507DUS-07
MateryèlZenk
FiniSatin Nickel (Brushed)
Bekè rive7 pous
Kalite aliyeMi mòn
Karakteristik espesyalLeak Resistant, Diverter Function
Dimansyon pwodwi7"D x 2.5"W x 2.5"H
Pwa atik12 ons
UPC747028638821
Westbrass E507DUS-07 Tub Spout with 7-inch and 5 3/8-inch dimensions

Image: The Westbrass E507DUS-07 tub spout showing its overall length of 7 inches and a base length of 5 3/8 inches, alongside the included installation components.

Westbrass E507DUS-07 Tub Spout top view with 7-inch length and 2.5-inch height

Imaj: Anwo-anba view of the Westbrass E507DUS-07 tub spout, indicating a 7-inch length and 2.5-inch height, with the diverter button visible.

Enstalasyon ak Enstalasyon

Zouti obligatwa

Etap enstalasyon yo

The Westbrass E507DUS-07 tub spout is designed for universal fit, accommodating 1/2-inch copper, 1/2-inch IPS, or 3/4-inch IPS connections. Follow the steps below based on your existing plumbing.

  1. Fèmen rezèv dlo a: Locate and turn off the main water supply to your bathroom or entire house. Open a faucet to relieve pressure.
  2. Remove Old Tub Spout: If replacing an existing spout, loosen any set screws on the underside of the spout or unscrew it counter-clockwise from the wall pipe. Clean the area around the pipe.
  3. Determine Connection Type: Identify if your existing pipe is 1/2-inch copper, 1/2-inch Male Threaded (IPS), or 3/4-inch Male Threaded (IPS).
  4. Prepare Koneksyon an:
    • For 1/2-inch Copper Pipe Connection: Ensure the copper pipe extends approximately 1-1/2 inches from the wall. Slide the 1/2-inch copper pipe fitting adapter onto the copper pipe. Secure it with the included hex wrench if there's a set screw.
    • For 1/2-inch Male Threaded Connection (IPS): Apply Teflon tape to the threads of the existing 1/2-inch male threaded pipe. Thread the brass adapter onto the pipe.
    • For 3/4-inch Male Threaded Connection (IPS): Apply Teflon tape to the threads of the existing 3/4-inch male threaded pipe.
  5. Install Extension Nipple (if needed): If your pipe does not extend far enough from the wall, use the included 4-inch extension nipple. Apply Teflon tape to the threads and connect it to your wall pipe or adapter.
  6. Attach Tub Spout:
    • For Slip-On (Copper) or Adapter Connections: Slide the tub spout onto the pipe/adapter assembly until it is flush with the wall. Secure it by tightening the set screw on the underside of the spout with the hex wrench.
    • For Threaded Connections (1/2-inch or 3/4-inch IPS): Carefully thread the tub spout onto the pipe/adapter assembly clockwise until it is hand-tight and properly aligned. Use a wrench for a final snug turn, but do not overtighten.
  7. Tès pou Fuites: Slowly turn the main water supply back on. Check all connections for leaks. If leaks occur, turn off the water, re-tighten connections, and re-test.
Westbrass E507DUS-07 Installation Diagram for various pipe types

Image: Diagram illustrating four common installation scenarios for the Westbrass E507DUS-07 diverter tub spout, including 1/2-inch copper pipe, 1/2-inch male threaded, 3/4-inch male threaded, and 1/2-inch male pipe with threaded end connections, showing how the adapters and extension nipple are used.

Westbrass E507DUS-07 Exploded View Dyagram

Imaj: Yon eksplozyon view diagram of the Westbrass E507DUS-07 tub spout, detailing its internal components such as the body, rod, O-rings, knob, gate, insert pipe, bushings, and set screw, along with a parts list.

Enstriksyon Operasyon

The Westbrass E507DUS-07 tub spout features a diverter mechanism to switch water flow between the tub spout and a showerhead.

Antretyen ak Swen

To maintain the finish and functionality of your tub spout, follow these guidelines:

Depanaj

Seksyon sa a adrese pwoblèm komen ou ka rankontre ak bouch basen ou an.

PwoblèmKòz posibSolisyon
Dlo ap koule nan baz tiyo a.Loose connection, insufficient Teflon tape, or damaged O-ring/gasket.Turn off water supply. Re-tighten the spout connection. If threaded, ensure adequate Teflon tape is applied. Inspect and replace any damaged O-rings or gaskets.
Diverter knob is stiff or not engaging.Akimilasyon mineral oswa mank lubrifikasyon.Clean the diverter mechanism. Apply a small amount of silicone-based lubricant to the moving parts of the diverter.
Water continues to drip from the tub spout when the diverter is engaged for the shower.Worn diverter gate or O-rings inside the spout.This indicates internal wear. Refer to the exploded view diagram (Image: Westbrass E507DUS-07 Exploded View Diagram) and consider replacing the internal gate or O-rings. If the issue persists, replacement of the spout may be necessary.
Spout does not fit existing plumbing.Incorrect adapter used or incompatible pipe type.Review the "Setup and Installation" section and the installation diagram (Image: Westbrass E507DUS-07 Installation Diagram) to ensure the correct adapter is selected for your pipe type (1/2-inch copper, 1/2-inch IPS, or 3/4-inch IPS). Confirm pipe extension from the wall is adequate.

Garanti ak sipò

Westbrass products are manufactured to high-quality standards. For specific warranty information or technical support, please refer to the official Westbrass websit la oubyen kontakte depatman sèvis kliyan yo. Kenbe resi acha w la pou reklamasyon garanti.

For additional information and products, you may visit the Westbrass Storefront.

Dokiman ki gen rapò - E507DUS-07

Preview Gid Enstalasyon Tiyo Beny Inivèsèl | WESTBRASS
Enstriksyon konplè pou enstalasyon tiyo WESTBRASS Universal Sea Breakers, ki kouvri divès kalite koneksyon tiyo tankou kwiv ak koneksyon gason filete. Aprann kijan pou enstale nouvo tiyo basen ou an byen.
Preview Gid Enstalasyon Tib Pwovizyon Westbrass D123
Enstriksyon enstalasyon ak detay pwodwi pou Tib Alimantasyon an Kwiv Masif Westbrass D123 la (3/8" OD x 12" Tèt Plat). Gen ladan etap pou konekte ak twalèt oswa lavabo.
Preview Gid Enstalasyon Westbrass D321H oswa 79417H pou Dlo Beny ak Debòdman
Enstriksyon enstalasyon ak gid antretyen pou drenaj Westbrass D321H oswa 79417H pou debòdman ak egou beny.
Preview Gid Enstalasyon Westbrass pou Dlo Beny ak Debòdman 2 Twou
Enstriksyon detaye pou enstalasyon ak lis pyès pou ekipman plonbri Westbrass 2-Hole Bathwaste & Overflow la. Gen ladan zouti ak etap ki nesesè pou yon bon enstalasyon.
Preview Westbrass HotMaster DigiHot Instant Hot Water Appliance Installation, Operation, and Care Guide
Comprehensive guide for installing, operating, and maintaining the Westbrass HotMaster DigiHot DT1F271-XX instant hot water appliance. Includes safety instructions, requirements, troubleshooting, and care tips.
Preview Westbrass HHF Shower Head Filter Replacement Guide
Information on Westbrass HHF-Series shower head filter replacements, including model compatibility, service life, and benefits for hair and skin.