OREiN OL3600140

OREiN OL3600140 Motion Sensor Outdoor Flood Light User Manual

Modèl: OL3600140

1. Entwodiksyon

This manual provides detailed instructions for the installation, operation, and maintenance of your OREiN Motion Sensor Outdoor Flood Light. Designed for outdoor use, this hardwired LED flood light features a 180° motion sensor, 450° adjustable light heads, and three distinct operating modes to enhance security and convenience around your property.

OREiN Motion Sensor Outdoor Flood Light, front view

Yon anlè view of the OREiN motion sensor outdoor flood light, showcasing its two adjustable light heads and central motion sensor in a black finish.

2. Enfòmasyon sou Sekirite

  • Sekirite elektrik: Installation must be performed by a qualified electrician or a person with adequate knowledge of electrical wiring. Ensure power is turned off at the circuit breaker before installation or servicing.
  • Voltage: This product operates on 110V-220V (AC) power. Verify your electrical supply matches this requirement.
  • Atè: Asire bon baz pou anpeche chòk elektrik.
  • Itilizasyon deyò: This fixture is rated IP65 waterproof for outdoor use. Do not submerge in water.
  • Chalè: LED lights can generate heat. Do not touch the light heads immediately after operation.

3. Pake kontni

Verifye ke tout konpozan yo prezan anvan ou kòmanse enstalasyon an:

  • OREiN Motion Sensor Flood Light (1 unit)
  • Manyèl Enstriksyon (dokiman sa a)
  • Mounting Bracket
  • Vis ak nwa fil

4. Espesifikasyon

KarakteristikSpesifikasyon
MakOREiN
Non modèlOL3600140
KoulèNwa
MateryèlAcrylonitrile Butadiene styrene
Fòm aparèy limyèFloodlight
Itilizasyon Andedan kay la / DeyòDeyò
Sous pouvwaFil elektrik (AC)
Voltage110-220 Vòlt (AC)
Kalite sous limyèdirije
Kantite sous limyè2
Limyè Koulè Tanperati5000K (Blan)
Klète1600 Lumen
Wattage12W (150W ekivalan)
Ang Capteur Mouvman180°
Mouvman Sensor RangeJiska 40 pye
Limyè Ajisteman Tèt450° (3 flexible joints per arm)
Nivo rezistans dloIP65 ki enpèmeyab
Viv lavi50,000 èdtan
SètifikasyonCE, FCC, RoHS

5. Enstalasyon ak Enstalasyon

The OREiN flood light is designed for hardwired installation and requires connection to a standard electrical junction box. It is not solar-powered, battery-operated, or plug-in.

5.1 Chèk Pre-Enstalasyon

  • Asire w ke ekipman pou kouran nan zòn enstalasyon an koupe nan disjonktè a.
  • Confirm that your junction box is compatible. The light's base measures 5.1in x 5.1in and is compatible with standard 2.75in or 3.5in junction boxes.
Diagram showing hardwired installation requirements for the OREiN flood light

This diagram illustrates that the OREiN flood light is hardwired and requires installation on a standard junction box, which is not included. Dimensions for the mounting bracket (3.54in and 2.75in) and the light base (5.1in x 5.1in) are provided.

5.2 Etap enstalasyon yo

  1. Monte bracket la: Securely attach the provided mounting bracket to your existing junction box using appropriate screws.
  2. Konekte fil elektrik: Carefully connect the wires from the flood light to your household wiring. Match the colors (e.g., black to black, white to white, ground to ground) and secure connections with the included wire nuts.
  3. Koneksyon an sekirite: Ensure all wire nut connections are tight and insulated.
  4. Tache limyè a: Align the flood light base with the mounting bracket and secure it with the provided screws.
Four-step visual guide for hardwired installation of the OREiN flood light

A visual guide detailing the four steps for hardwired installation: 1. Fix the bracket to a junction box. 2. Connect wires of the same color. 3. Tighten connections with wire nuts. 4. Fix the light with screws.

5.3 Montaj Opsyon

The flood light can be installed in various outdoor locations, including wall-mounted or soffit-mounted (under an eave).

Examples of soffit mounted and wall mounted installations for the OREiN flood light

This image displays two common installation methods: soffit mounted (under an eave) and wall mounted, illustrating the versatility of the flood light's placement.

6. Operasyon Enstriksyon

6.1 Ajiste tèt limyè yo

The flood light features three flexible joints on each light arm, allowing for a 450° superwide adjustment. This enables you to direct the light precisely where needed, minimizing light spill into unwanted areas or illuminating specific corners.

Diagram showing the 6 adjustable joints on the OREiN flood light

A detailed diagram highlighting the six adjustable joints on the light arms and sensor, allowing for 450° superwide adjustment. It shows the LED spotlights for farther and brighter illumination.

6.2 Mòd Fonksyònman

The OREiN flood light offers three distinct operating modes, selectable via the red button on the base of the unit:

  • 1. Dim Light Dusk-to-Dawn Mode (DIM-ON-DIM): The light automatically turns on at 30% brightness at dusk and remains at this level. Upon detecting motion, it switches to 100% brightness for a set duration, then returns to 30% brightness.
  • 2. Security Mode (OFF-ON-OFF): The light remains off at night. Upon detecting motion, it turns on to 100% brightness for a set duration, then turns off completely.
  • 3. Mòd manyèl: The light can be manually turned on or off using your wall switch, operating at 100% brightness when on.
Illustrations of the three operating modes: Dimmable Dusk-to-Dawn, Motion Mode, and Manual Mode

This image visually explains the three operational modes: Dimmable Dusk-to-Dawn (30% brightness at night, 100% on motion), Motion Mode (off at night, 100% on motion), and Manual Mode (controlled by a wall switch).

6.3 Switching Modes and Resetting

Use the red button located on the base of the flood light for control:

  • On/Off: Long press the red button for 2 seconds.
  • Chanje mòd: Single click the red button. Observe the light's flash pattern to identify the current mode:
    • A. Light flashes quickly twice: Dimmable Dusk-to-Dawn Mode
    • B. Light flashes slowly twice: Motion Mode
    • C. Light is fixed: Manual Mode
  • Reyajiste: Long press the red button for 10 seconds.
Instructions for using the red button to set modes and reset the OREiN flood light

This image provides instructions for the red button on the light's base: long press for 2 seconds to turn On/Off, single click to switch modes (indicated by light flashes), and long press for 10 seconds to reset.

6.4 Motion Sensor Settings

The motion sensor has three adjustable knobs: TIME, SENS, and LUX. These allow you to customize the sensor's behavior.

  • TAN: Adjusts the duration the light stays on after motion is detected, ranging from 10 seconds to 8 minutes.
  • SENS (Sensiblite): Controls the detection range and sensitivity of the motion sensor.
  • LUX (Daylight Threshold): Determines the ambient light level at which the sensor becomes active. For night-only operation, set the LUX knob to the minimum value (moon side). If set to the maximum (sun side), the light may activate during the day.
Diagram showing the 180 degree motion sensor detection range and adjustment knobs

An illustration demonstrating the 180° motion sensor's 40-foot detection range. It also shows the adjustment knobs for TIME (10s-8mins delay), SENS (sensitivity), and LUX (daylight threshold).

7. Antretyen

To ensure optimal performance and longevity of your OREiN flood light, follow these maintenance guidelines:

  • Netwayaj: Netwaye tèt limyè yo ak lantiy detèktè mouvman an detanzantan avèk yon savon mou.amp cloth. Avoid abrasive cleaners or solvents that could damage the finish or sensor.
  • Enspeksyon: Regularly inspect the wiring and mounting for any signs of wear, damage, or loosening. Ensure the light heads and sensor are free from obstructions like spiderwebs oswa debri.
  • Rezistans move tan: The IP65 rating ensures protection against dust and water jets. While designed for various weather conditions, extreme conditions may require additional checks.
OREiN flood light operating in heavy rain, demonstrating IP65 waterproof rating

The image shows the OREiN flood light functioning during heavy rain, highlighting its IP65 waterproof rating, heat resistance, and snowproof capabilities for various extreme weather conditions.

NAN. Depanaj

If you encounter issues with your OREiN flood light, refer to the following common problems and solutions:

  • Limyè a pa limen lannwit:
    • Check the LUX setting. Ensure it is set to the minimum value (moon side) for night-only operation. If set to the sun side, the light will not activate in darkness.
    • Verify the power supply to the fixture.
  • Light does not detect motion:
    • Adjust the SENS (sensitivity) knob to a higher setting.
    • Asire w pa gen okenn obstak ki bloke chan mayetik detèktè a. view.
    • Confirm the light is in either 'Dim Light Dusk-to-Dawn' or 'Security Mode'.
  • Limyè a rete limen san rete:
    • Tcheke paramèt TAN an; li ka fikse sou yon dire ki long anpil.
    • Ensure the sensor is not continuously detecting motion (e.g., from moving branches, pets, or traffic). Adjust the sensor's angle or sensitivity.
    • If in Manual Mode, the light will remain on until switched off.
  • Light flickers or operates erratically:
    • Check all electrical connections for tightness and proper insulation.
    • Asire voltagPwovizyon an stab epi li nan limit espesifye a.

9. Garanti

This OREiN product is covered by a 2-ane garanti apati dat acha a. Garanti sa a kouvri domaj nan materyèl ak nan fabrikasyon anba itilizasyon nòmal. Tanpri konsève prèv acha ou pou reklamasyon garanti.

10. Sipò

For any questions, technical assistance, or warranty claims, please contact OREiN customer support:

  • Sipò telefòn: 1-844-506-1530 (during working hours)
  • Èd sou entènèt: 7 days a week, 24 hours a day. Please refer to the official OREiN website or your purchase platform for online contact options.

Dokiman ki gen rapò - OL3600140

Preview OREIN Sensor Adjustment Instructions
A guide to adjusting the settings for OREIN motion sensor outdoor lights, covering TIME, SENS, and LUX adjustments for various lighting modes.
Preview Limyè Sekirite LED OREIN ak Capteur Mouvman: Gid Enstalasyon ak Operasyon
Gid detaye pou enstalasyon, konfigirasyon ak depanaj pou Limyè Sekirite LED OREIN ak Capteur Mouvman (Modèl OL3600140). Aprann sou paramèt capteur yo, mòd fonksyònman yo, ak espesifikasyon pwodwi yo.
Preview Limyè deyò OREIN OL3600140 LED ak detèktè mouvman: Gid enstalasyon ak operasyon
Gid sa a bay enstriksyon detaye pou enstale, opere, ak kenbe limyè deyò OREIN OL3600140 LED Motion Sensor yo. Aprann sou paramèt detèktè yo, mòd yo, depanaj la, ak espesifikasyon pwodwi yo.
Preview Manyèl Enstalasyon ak Itilizatè pou Limyè Deyò OREiN Smart Motion Sensor OL36002440
Gid konplè pou enstale ak itilize Limyè Deyò ak Capteur Mouvman Entelijan OREiN yo, Modèl OL36002440. Gen ladan l konfigirasyon, ajisteman capteur, mòd, depanaj, ak enstriksyon koneksyon aplikasyon an.
Preview Manyèl Itilizatè OREIN Limyè Inondasyon Entelijan Deyò ak Capteur Mouvman OL27002546
Manyèl itilizatè pou Limyè Entelijan Deyò OREIN ak Capteur Mouvman (Modèl OL27002546). Gen ladan gid enstalasyon, paramèt capteur, deskripsyon mòd, depanaj, espesifikasyon pwodwi, ak enstriksyon koneksyon aplikasyon an.
Preview Limyè Sekirite LED OREiN ak Capteur Mouvman: Manyèl Enstalasyon ak Operasyon
Gid konplè pou enstale ak itilize Limyè Sekirite LED OREiN ak Capteur Mouvman (30W, 4500LM). Gen ladan l prekosyon sekirite, enstriksyon enstalasyon, depanaj, ak konsèy antretyen.