1. Entwodiksyon

This manual provides detailed instructions for the assembly, installation, and operation of your Perlegear 10U Open Frame Network Rack (Model PGSER02B). Please read this manual thoroughly before installation to ensure proper setup and safe use. Keep this manual for future reference.

Perlegear 10U Open Frame Network Rack, front view with two vented shelves installed.

Figure 1: Perlegear 10U Open Frame Network Rack with shelves.

2. Enfòmasyon sou Sekirite

Obsève prekosyon sekirite sa yo pandan asanblaj ak itilizasyon:

  • Asire w tout konpozan yo prezan epi yo pa domaje anvan asanblaj la.
  • Do not exceed the maximum load capacity of 200 lbs for the rack and 22 lbs for the top panel.
  • When wall-mounting, ensure the mounting surface (e.g., wood studs, concrete wall) can safely support the rack's weight and its contents. Do not mount on drywall alone.
  • Sèvi ak zouti ki apwopriye yo epi swiv tout etap enstalasyon yo ak anpil atansyon.
  • Kenbe timoun ak bèt kay lwen zòn asanble a.

3. Pake kontni

Verify that all parts are included in your package:

Diagram showing all components included in the Perlegear 10U Network Rack package: Rack Frame x2, Shelf x2, Back Brace x2, Front Brace x2, M6 Bolt x40, Cage Nut x8, M6 Nut x12, Wall Anchor x6, Lag Screw x6, Wall Plate Template.

Figure 2: Complete Package Contents.

  • Rack Frame (x2)
  • Etajè (x2)
  • Back Brace (x2)
  • Front Brace (x2)
  • M6 Bolt (x40)
  • Cage Nut (x8)
  • M6 nwa (x12)
  • Anchor mi (x6)
  • Lag Screw (x6)
  • Wall Plate Template (x1)

4. Espesifikasyon

KarakteristikSpesifikasyon
Nimewo ModèlPGSER02B
Rack Units (U)10U
Dimansyon pwodwi (D x W x H)20.12" x 20.5" x 19.39" (51.1cm x 52.1cm x 49.2cm)
Pwa atik30.5 liv (13.8 kg)
MateryèlCold-rolled Steel
KoulèNwa
Max Load Capacity (Rack)200 liv (90.7 kg)
Max Load Capacity (Top Panel)22 liv (10 kg)
Konpatibilite19-inch networking, AV, and IT equipment
Diagram showing the product dimensions of the Perlegear 10U Open Frame Network Rack, including depth, width, and height, along with a visual representation of the included hardware kit.

Figure 3: Product Dimensions and Hardware Kit Overview.

5. Enstalasyon ak Enstalasyon

The Perlegear 10U Open Frame Network Rack offers flexible installation options: wall-mounted or floor-standing. Follow these steps for assembly and installation.

5.1. Assembly Overview

Three-step diagram showing the assembly process: 1. Assemble Frame, 2. Mount to Wall, 3. Install Shelves.

Figure 4: Simple Setup Overview.

5.2. Detailed Assembly Steps

Pou yon gid vizyèl, tanpri gade videyo enstalasyon ofisyèl ki anba a:

Video 1: Perlegear 10U Network Rack Installation Tutorial. This video demonstrates the step-by-step assembly and installation process for the rack.

  1. Rasanble ankadreman an:
    • Identify the Left and Right Frames, Back Braces, and Front Braces.
    • Attach the Back Braces to the bottom of the Left and Right Frames using M6 Bolts and M6 Nuts. Ensure the side with three holes on the frame faces the front.
    • Attach the Front Braces to the top of the Left and Right Frames, again ensuring the side with three holes faces the front. The 'PERLEGEAR' logo on the front brace should be visible.
    • Tighten all M6 Nuts using a PH2 or PZ2 screwdriver and a 10mm wrench for secure assembly.
  2. Enstale etajè:
    • Insert the two 1U vented shelves into the desired rack unit positions.
    • Utilize the provided shelf reinforcement brackets to support the shelves and prevent sagging, especially for heavier equipment. These brackets can be installed on one shelf or across two different shelves for added stability.
    Diagram illustrating two options for shelf reinforcement: installing both brackets on one shelf or installing brackets on two different shelves.

    Figure 5: Shelf Reinforcement Options.

  3. Opsyon Montaj:
    • Floor-Standing: Place the assembled rack on a stable, level surface. The rack includes caster holes at the bottom for optional mobility (casters not included).
    • Mi-monte: Use the provided drilling template to mark pilot holes. Mount the rack to 16-inch wood studs (without anchors) or concrete walls (with anchors) using the lag screws. Ensure the rack is securely fastened before loading equipment.
    Image showing the Perlegear 10U rack in two configurations: wall-mounted with equipment and floor-standing with a laptop on top and equipment inside.

    Figure 6: Flexible Setup - Wall-mounted and Floor-standing configurations.

6. Operasyon Enstriksyon

Once assembled and installed, the Perlegear 10U Open Frame Network Rack is ready for use.

6.1. Ekipman Enstalasyon

  • Install your 19-inch rack-mounted networking, AV, and IT equipment into the rack units.
  • Utilize the two 1U vented shelves for non-rack-mountable devices such as smaller switches, storage devices, or UPS units.
  • Ensure proper cable management to maintain airflow and prevent obstruction.
Image showing a wall-mounted Perlegear 10U rack filled with various 19-inch networking and AV equipment, highlighting the 10U space and compatibility with 16-inch wood studs.

Figure 7: Rack with 10U Space and Equipment.

6.2. Airflow and Cooling

The open frame design and vented shelves promote optimal airflow, which is crucial for keeping your networking, audio, and video equipment cool and preventing overheating.

Diagram showing a wall-mounted Perlegear 10U rack with equipment, illustrating airflow arrows to demonstrate how the open rack and vented shelves help improve cooling.

Figure 8: Enhanced Airflow for Equipment Cooling.

6.3. Expandability

This server rack features an expandable design. You can stack two 10U racks to create a 20U rack, doubling your storage capacity for growing equipment needs. Ensure to remove the top panel of the bottom rack when stacking.

Image showing two Perlegear 10U racks stacked to form a 20U rack, with a close-up of the caster holes at the bottom (casters not included).

Figure 9: Stackable Design for Increased Capacity.

Image showing a Perlegear 10U rack with equipment, positioned under a staircase, demonstrating how additional items can be stored on the top surface of the rack.

Figure 10: Utilizing the Top Surface for Additional Storage.

7. Antretyen

Regular maintenance ensures the longevity and optimal performance of your network rack:

  • Netwayaj: Wipe the rack surfaces with a soft, dry cloth to remove dust. For stubborn marks, use a mild, non-abrasive cleaner.
  • Enspeksyon: Periodically check all bolts and nuts to ensure they remain tight. Re-tighten if necessary.
  • Verifikasyon Chaj: Verify that the total weight of equipment does not exceed the maximum load capacity.

NAN. Depanaj

If you encounter any issues, consider the following:

  • Enstabilite etajè: Ensure all bolts and nuts are securely tightened. If wall-mounted, confirm the mounting hardware is correctly installed into appropriate structural supports.
  • Equipment Overheating: Check for proper cable management that might obstruct airflow. Ensure the rack is not placed in an enclosed space without adequate ventilation.
  • Difficulty Installing Equipment: Verify that your equipment is 19-inch rack-mountable. Ensure cage nuts are correctly inserted into the square holes before attaching equipment with M6 bolts.

9. Garanti ak sipò

Perlegear products are designed for durability and performance. For warranty information, technical support, or to purchase replacement parts, please visit the official Perlegear website or contact customer service through your retailer.

Dokiman ki gen rapò - PGSER02B

Preview Manyèl Enstriksyon pou Etajè Odinatè Sèvè Perlegear PGSER02 la
Manyèl enstriksyon detaye pou rasanble ak enstale etajè òdinatè sèvè Perlegear PGSER02 la. Gen ladan lis pyès, zouti ki nesesè yo, avètisman sekirite, ak gid enstalasyon etap pa etap pou poto an bwa ak mi beton solid.
Preview Perlegear PGTVMC04 TV Stand Instruction Manual
Comprehensive assembly and safety guide for the Perlegear PGTVMC04 mobile TV stand with casters. This manual provides detailed instructions, parts lists, hardware specifications, and step-by-step procedures for securely mounting televisions and shelves.
Preview Kesyon yo poze souvan (FAQ) sou sipò miray pou televizyon Perlegear
Jwenn repons pou kesyon komen sou sipò miray pou televizyon Perlegear, tankou modèl VESA, kalite miray, defi enstalasyon, ak etap depanaj.
Preview Manyèl Enstriksyon pou Sipò Televizyon Perlegear PGFS06
Manyèl enstriksyon konplè pou Sipò Televizyon atè Perlegear PGFS06 la. Gid sa a bay etap detaye pou verifikasyon konpatibilite, asanblaj, montaj televizyon, enstalasyon etajè, jesyon kab, ak ajisteman, pou asire yon konfigirasyon televizyon ki an sekirite e optimal.
Preview PERLEGEAR PGFS10/PGFS10W TV Stand Assembly Instructions
Comprehensive guide for assembling the PERLEGEAR PGFS10 and PGFS10W TV stands, including compatibility checks, parts list, and step-by-step instructions with safety precautions.
Preview Manyèl Enstriksyon pou Sipò Televizyon Perlegear PGFS09
Manyèl enstriksyon konplè pou sipò televizyon Perlegear PGFS09 la, ki detaye asanblaj la, verifikasyon konpatibilite, ak direktiv sekirite pou monte televizyon soti nan 32 a 70 pous.