1. Entwodiksyon
This manual provides comprehensive instructions for the installation, operation, maintenance, and troubleshooting of your Longriver Tem8(R7Pro) Shower Filter with Wireless Temperature Display. Please read this manual thoroughly before use to ensure proper function and longevity of the product. Retain this manual for future reference.
2. Pwodwi souview
The Longriver Tem8(R7Pro) is a 2-in-1 shower filter system designed to improve water quality and provide real-time temperature monitoring. It features advanced filtration and a wireless temperature display for enhanced showering comfort and safety.
- Hydroelectric Power: The filter incorporates a micro hydroelectric generator that powers the wireless temperature display, eliminating the need for external power sources for the filter unit.
- Filtraj Avanse: The R7Pro model effectively removes up to 99.99% of chlorine and heavy metals from your shower water, contributing to healthier skin and hair.
- Wireless Temperature Display: An external display unit shows the current water temperature in real-time (response time of 0.25 seconds), preventing water from being too hot or too cold.
- Consistent Water Pressure: The design ensures that the installation of this filter does not negatively impact your bathroom's water pressure.
- Enstalasyon fasil: Designed for quick and tool-free setup with standard 1/2 inch ports.

Figure 2.1: The Longriver Tem8(R7Pro) Shower Filter and its Wireless Temperature Display.

Figure 2.2: Diagram illustrating the multi-stage filtration layers designed to improve water quality for skin and hair health.
3. Enfòmasyon sou Sekirite
- Asire ke tout koneksyon yo sere pou anpeche koule.
- Do not expose the wireless temperature display to direct water spray for extended periods, as it is designed for splash resistance, not submersion.
- Kenbe pwodwi a soti nan atenn timoun yo.
- Pa eseye demonte oswa repare aparèy la tèt ou. Kontakte sèvis kliyan pou asistans.
- Use only genuine replacement filter cartridges to ensure optimal performance and avoid damage.
4. Pake kontni
Verifye ke tout konpozan yo prezan nan pake ou a:
- Tem8(R7Pro) Shower Filter Unit
- Wireless Temperature Display Screen
- Mounting Plate for Display (with 3M adhesive tape)
- Manyèl Itilizatè (dokiman sa a)
5. Gid Enstalasyon
The Tem8(R7Pro) shower filter is designed for easy, tool-free installation. Follow these steps:
5.1. Shower Filter Installation
- Remove your existing showerhead from the shower arm.
- Screw the Tem8(R7Pro) shower filter onto the shower arm. Ensure the connection is hand-tight.
- Screw your showerhead onto the bottom of the Tem8(R7Pro) shower filter. Ensure this connection is also hand-tight.
- Verify that the water inlet and outlet directions on the filter are correct. Incorrect connection will prevent proper function.
5.2. Wireless Temperature Display Installation
- Remove the mounting plate from the back of the wireless display unit.
- Peel off the protective film from the 3M adhesive tape on the back of the mounting plate.
- Attach the mounting plate to a clean, dry wall surface near your shower, within 6.56 feet (2 meters) of the filter unit for optimal signal reception.
- Press the power button on the back of the display unit to activate it.
- Mete ekran ekspozisyon an nan plak zen an depi anwo jouk anba.

Figure 5.1: Step-by-step installation guide for the shower filter and wireless temperature display.

Figure 5.2: The filter is compatible with rain showers, fixed showers, and handheld showers, featuring standard G1/2 inch ports.
6. Operasyon Enstriksyon
Once installed, the Tem8(R7Pro) system operates automatically when water flows through the filter.
6.1. Real-time Temperature Display
The wireless display unit will show the water temperature in Fahrenheit (°F) as soon as water begins to flow. The display updates rapidly, typically within 0.25 seconds.
- Limyè ble: Indicates water temperature is below 86°F (too low).
- Limyè vèt: Indicates water temperature is between 86°F and 104°F (suitable).
- Limyè wouj: Indicates water temperature is above 104°F (too high).
The temperature sensing range is 0°F to 188°F.

Figure 6.1: The wireless display provides real-time temperature readings with color indicators for easy temperature assessment.

Figure 6.2: The temperature display assists in setting appropriate water temperatures for various users, such as pets (102°F), babies (95°F), and adults (98°F).
7. Antretyen
7.1. Ranplasman Katouch Filtè a
The filter cartridge should be replaced regularly to maintain optimal filtration performance. The recommended replacement interval is every 3 months, or after approximately 250 baths or 500 showers, depending on water quality and usage.
- Fèmen tiyo dlo ki nan douch ou a.
- Unscrew the shower filter unit from the shower arm.
- Carefully separate the two halves of the filter housing.
- Remove the old filter cartridge and dispose of it responsibly.
- Insert a new, genuine Longriver replacement cartridge into the filter housing, ensuring it is seated correctly.
- Reassemble the filter housing, ensuring a tight seal.
- Screw the filter unit back onto the shower arm, then reattach your showerhead.
- Turn on the water supply and check for leaks. Flush the filter with cold water for a few minutes before use.

Figi 7.1: Koupe view of the shower filter, illustrating the internal cartridge that requires periodic replacement.
NAN. Depanaj
| Pwoblèm | Kòz posib | Solisyon |
|---|---|---|
| No temperature displayed / Display flickering | Low battery in display unit; Display out of signal range; Sensor malfunction. | Ensure the display unit is within 6.56 feet (2 meters) of the filter. Check if the display unit needs charging (if applicable, though hydroelectric power is for the filter, the display might have its own battery). Contact customer support if the issue persists. |
| Dlo k ap koule nan koneksyon yo | Loose connections; Missing or damaged rubber washers. | Ensure all connections are hand-tight. Check that rubber washers are properly seated and not damaged. Do not overtighten. |
| Presyon dlo redwi | Clogged filter cartridge; Incorrect installation. | Replace the filter cartridge if it's due for replacement. Recheck installation steps to ensure correct assembly. |
| Filter unit appears cracked or damaged | Physical impact; Overtightening during installation. | Discontinue use immediately. Contact customer service for a replacement. Avoid overtightening during installation. |
9. Espesifikasyon
- Nimewo Modèl: MX08
- Manifakti: Foshan Microcore Electronics Technology Co.Ltd
- Pwa atik: 1.28 liv
- Dimansyon pwodwi: 6.1 x 4.1 x 5.91 pous
- Koulè: Nwa
- Batri: 1 Lithium Polymer battery required (included for display)
- Eleman ki enkli: Showerhead Filter, Wireless Temperature Display Screen
- Kalite koneksyon: Standard 1/2 inch port
- Temperature Sensing Range: 0°F pou 188°F
- Temperature Response Speed: 0.25 segonn
10. Sipò pou Kliyan
For any questions, concerns, or assistance with your Longriver Tem8(R7Pro) Shower Filter, please contact our customer service team. We offer 24/7 online customer service to address any issues you may encounter.
Please refer to your product packaging or the retailer's websit la pou jwenn enfòmasyon kontak espesifik.