1. Pwodwi souview
The Browin DragON Jet 2 Long Cold Smoke Generator is designed for enthusiasts of homemade smoked products, offering an efficient and professional method for cold and hot smoking. This device ensures intense smoke aromas for various foods like meats, fish, and cheeses, without the need for unnecessary chemical additives. Its innovative design provides excellent quality and efficiency in the smoking process.
The generator is versatile and can be integrated into various smoking chambers, both large and small. It has been tested with smokers up to 300 liters capacity, demonstrating its broad applicability.
Karakteristik kle:
- Professional smoking tool providing intense smoke aromas.
- Ensures perfect and uniform smoke injection into the smoker.
- High efficiency with low wood chip consumption.
- Innovative ash tray for continuous smoking without interruption.
- Suitable for various devices including barbecues, smokers, and smokehouses.
2. Konpozan enkli
Before assembly, please ensure all components listed below are present in your package:
- Kouvèti an bwa
- Cylinder (feed body) with smoke generator made of 304 stainless steel
- Ponp elektrik (3.8 W)
- Smoke generator nozzle with angled tube
- Stainless steel mounting base
- Set of connectors (T-piece, silicone hoses)
- M8 stainless steel washers (4 pieces)
- M8 x 40 stainless steel screws (2 pieces) - suitable for wall thickness up to 3 cm. For thicker walls, appropriate screws must be sourced separately.
- M8 stainless steel nuts (2 pieces)
- Manyèl enstriksyon
- Package of incense chips (wood chips)

Image: All components of the Browin DragON Jet 2 Long Cold Smoke Generator, including the main cylinder, pump, mounting bracket, tubes, and small parts.
3. Enstalasyon ak Enstalasyon
Follow these steps to correctly assemble and install your cold smoke generator:
- Attach the Mounting Base: Secure the stainless steel mounting base to the side of your smoker or barbecue using the provided M8 screws, washers, and nuts. Ensure the base is firmly attached and level.
- Mount the Cylinder: Slide the main stainless steel cylinder onto the mounting base. The cylinder should sit securely in the designated slots on the base.
- Connect the Angled Tube: Insert the smoke generator nozzle with the angled tube into the opening on the side of the cylinder. Ensure it points into the smoking chamber.
- Install the Ash Tray: Position the innovative ash tray at the bottom of the cylinder. This tray collects spent wood chips and allows for easy removal.
- Connect the Electric Pump: Attach the electric pump to the smoke generator using the silicone hoses and T-piece connector. Ensure all connections are airtight to maintain proper airflow. The pump provides the necessary air pressure for smoke generation.
- Place the Wooden Lid: Once assembled, place the wooden lid on top of the cylinder.

Image: The fully assembled Browin DragON Jet 2 Long Cold Smoke Generator, showing the main cylinder, mounting bracket, angled tube, and attached electric pump.

Imaj: Bò kote view of the assembled smoke generator, indicating the 20 cm length of the smoke outlet tube.
4. Operasyon Enstriksyon
Operating the DragON Jet 2 Long is straightforward. Follow these steps for effective cold smoking:
- Prepare bato bwa yo: Fill the cylinder with appropriate wood chips for smoking. Ensure the chips are dry and of a suitable size for smoke generation. The included package of incense chips can be used for your first smoking session.
- Limen bato bwa: Ignite the wood chips at the bottom of the cylinder. A small torch or lighter can be used for this purpose. Ensure a consistent ember is established.
- Aktive ponp lan: Plug in the electric pump and turn it on. The pump will supply air to the burning wood chips, creating a steady flow of cold smoke into your smoking chamber. Adjust the pump's airflow if necessary to control smoke density.
- Monitor Smoking Process: Allow the smoking process to continue for the desired duration, depending on the food item and desired flavor intensity. The innovative ash tray allows for easy removal of spent chips without interrupting the smoking process, enabling longer smoking sessions.
- Refill Wood Chips (if needed): If smoking for extended periods, you may need to refill the wood chips. Carefully remove the wooden lid and add more chips, ensuring the embers are not extinguished.
- Konplete: Once smoking is complete, turn off the electric pump and allow the remaining wood chips to burn out or extinguish them safely.

Image: The smoke generator in operation, attached to a traditional brick smokehouse, producing smoke for curing meats.

Image: The smoke generator attached to a modern electric smoker, demonstrating its versatility with different types of smoking chambers.
5. Antretyen ak Swen
Regular cleaning and maintenance will ensure the longevity and optimal performance of your smoke generator:
- Empty Ash Tray: After each use, allow the unit to cool completely, then remove and empty the ash tray. Dispose of ashes safely.
- Clean Cylinder: Periodically clean the inside of the stainless steel cylinder to remove creosote buildup. A stiff brush and warm soapy water can be used. Rinse thoroughly and dry completely before next use.
- Enspekte tiyo ak koneksyon yo: Regularly check the silicone hoses and connectors for any cracks, blockages, or signs of wear. Replace if necessary to maintain an airtight system.
- Swen Ponp: Keep the electric pump clean and free from dust and debris. Ensure its air intake is not obstructed. Do not immerse the pump in water.
- Depo: Store the smoke generator in a dry, protected area when not in use to prevent rust and damage.
NAN. Depanaj
If you encounter issues with your smoke generator, refer to the following common problems and solutions:
- No Smoke Production:
- Ensure wood chips are properly ignited and glowing embers are present.
- Check if the electric pump is powered on and functioning.
- Verify that all silicone hose connections are secure and airtight.
- Ensure the air intake of the pump is not blocked.
- Clean any creosote buildup in the cylinder or angled tube that might be obstructing airflow.
- Inconsistent Smoke Flow:
- Check for blockages in the angled tube or cylinder.
- Ensure the wood chips are not packed too tightly, which can restrict airflow.
- Verify the pump is providing consistent air pressure.
- Wood Chips Not Burning Completely:
- Ensure wood chips are dry. Damp chips will not burn efficiently.
- Increase the airflow from the electric pump.
- Ensure the initial ignition is thorough, creating a good bed of embers.
- Kondansasyon twòp:
- This can be a common issue with cold smoke generators. Ensure adequate ventilation in your smoking chamber.
- Consider adding a condensation trap if your smoker setup allows for it.
7. Spécifications pwodwi
| Karakteristik | Detay |
|---|---|
| Mak | BROWIN rok zał. 1979 |
| Nimewo Modèl | 330146 |
| Koulè | Steel |
| Materyèl | Nerjaveèi asye |
| Pwa atik | 3.7 Kilogram |
| Sous pouvwa | Electric (Cable) |
| Electric Pump Power | 3.8 W (as per description) / 5 W (as per image) - Note: Please refer to product packaging for exact pump wattage. |
| Pump Airflow | 420 L/h (as per image) |
| Dimansyon rasanble (apeprè) | Height: 383 mm, Length: 489 mm, Width: 153 mm (refer to diagram) |
| Dimansyon pake | 39 x 30 x 10.5 cm |
| Konpatibilite | Suitable for smokers up to 300 liters capacity |

Image: Technical diagram illustrating the approximate height (383 mm), length (489 mm), and width (153 mm) of the assembled smoke generator.

Image: Close-up of the electric pump, highlighting its 5W power consumption and 420 L/h airflow capacity.
8. Garanti ak sipò
Information regarding specific warranty terms for the Browin DragON Jet 2 Long Cold Smoke Generator is not provided in the product details. Please refer to the product packaging or contact the manufacturer directly for warranty details and customer support.
For technical assistance or inquiries about spare parts, please reach out to Browin customer service. Contact information can typically be found on the product packaging or the official Browin websit.
Manifakti: Browin