1. Entwodiksyon
This manual provides essential information for the safe and efficient installation, operation, and maintenance of the Weidmuller UR20-FBC-MOD-TCP-ECO I/O Module. Please read this manual thoroughly before attempting to install or operate the device.
The UR20-FBC-MOD-TCP-ECO is an industrial I/O module designed for robust performance in various automation applications. It features a 24 VDC input voltage and push-in termination style for reliable connections.
2. Enfòmasyon sou Sekirite
- Always disconnect power before installing, wiring, or servicing the module.
- Se sèlman pèsonèl kalifye ki ta dwe fè enstalasyon ak antretyen.
- Ensure proper grounding to prevent electrical shock and ensure correct operation.
- Operate the module within the specified environmental conditions (temperature, humidity).
- Do not expose the module to excessive moisture or corrosive substances.
3. Pwodwi souview
The Weidmuller UR20-FBC-MOD-TCP-ECO is a compact I/O module designed for distributed control systems. It integrates seamlessly into industrial networks, providing reliable data acquisition and control capabilities.

3.1 Karakteristik kle
- Konsepsyon kontra enfòmèl ant pou enstalasyon ekonomize espas.
- Push-in termination technology for quick and reliable wiring.
- Wide ranje tanperati opere (-20 ° C a + 60 ° C).
- Ethernet/TCP communication capabilities.
4. Enstalasyon ak Enstalasyon
4.1 Montaj
- Ensure the DIN rail is securely mounted in a suitable enclosure.
- Aliyen klip ray DIN modil la ak kwen anwo ray DIN nan.
- Press the module firmly downwards until it clicks into place on the DIN rail.
- Verifye ke modil la byen fikse epi li pa tranble.
4.2 fil elektrik
The UR20-FBC-MOD-TCP-ECO utilizes push-in termination for electrical connections. Ensure all wires are stripped to the recommended length before insertion.
- Pwovizyon pou pouvwa: Connect a stable 24 VDC power supply to the designated power terminals. Observe correct polarity (+ and -).
- Rezo Koneksyon: Connect standard Ethernet cables to the RJ45 ports for network communication.
- Koneksyon I/O: Connect field devices to the appropriate input/output terminals as per your system design. Refer to the system documentation for specific pin assignments.
- Ensure all connections are firm and free from loose strands.
4.3 Premye pouvwa-up
After all connections are made and verified, apply power to the module. Observe the status indicator LEDs for proper initialization.
5. Operasyon
Once powered, the UR20-FBC-MOD-TCP-ECO module will establish communication with the connected network controller. The module's operational status can be monitored via its integrated LED indicators.
5.1 Endikatè Estati yo
Refer to the module's labeling for the exact meaning of each LED. Typically, these include:
- Pouvwa dirije: Indicates power supply status.
- Estati Rezo ki ap dirije: Indicates network connection and communication activity.
- I/O Status LEDs: Indicate the status of individual input/output channels.
5.2 Kominikasyon rezo
The module communicates over Ethernet using TCP/IP protocols. Configuration of network parameters (e.g., IP address) is typically performed via the connected controller or a dedicated configuration tool.
6. Antretyen
Regular maintenance ensures the longevity and reliable operation of the I/O module.
- Netwayaj: Periodically clean the module's exterior with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure power is disconnected before cleaning.
- Enspeksyon: Regularly inspect wiring connections for tightness and signs of damage or corrosion. Check for any physical damage to the module housing.
- Mizajou mikrolojisyèl: Consult the Weidmuller website or your system integrator for information on available firmware updates. Follow all instructions carefully when performing updates.
NAN. Depanaj
Seksyon sa a bay konsèy pou pwoblèm komen. Pou pwoblèm konplèks, kontakte sipò teknik.
| Pwoblèm | Kòz posib | Solisyon |
|---|---|---|
| Pa gen okenn endikasyon LED pouvwa | Pa gen ekipman pou kouran; fil elektrik ki pa kòrèk; modil ki gen pwoblèm. | Check 24 VDC power supply; verify wiring polarity; test with a known good power source. |
| Network Status LED off/flashing incorrectly | No network connection; incorrect network settings; faulty cable. | Check Ethernet cable connection; verify network configuration (IP address, subnet mask); replace cable. |
| Antre/Sòti pa reponn | Incorrect I/O wiring; faulty field device; software configuration error. | Verify I/O wiring; test field device independently; check controller software configuration. |
8. Espesifikasyon teknik
| Paramèt | Valè |
|---|---|
| Nimewo Modèl | UR20-FBC-MOD-TCP-ECO |
| Nimewo Pati | 2659700000 |
| Manifakti | Weidmuller |
| Antre Voltage | 24 VDC |
| Style revokasyon | Pouse-nan |
| Tanperati Minimòm Fonksyònman | -20°C |
| Maksimòm Tanperati Fonksyònman | +60°C |
| Pwa atik | 6.99 liv |
9. Enfòmasyon sou Garanti
Weidmuller products are manufactured to high-quality standards. For specific warranty terms and conditions, please refer to the official Weidmuller warranty statement available on their websit la oubyen kontakte distribitè lokal ou a. Kenbe prèv acha ou pou reklamasyon garanti.
10. Sipò teknik
For technical assistance, product inquiries, or service requests, please contact your authorized Weidmuller distributor or visit the official Weidmuller websit pou resous sipò ak enfòmasyon pou kontakte yo.