1. Entwodiksyon
This manual provides essential information for the proper installation, operation, and maintenance of the Bunn 4623-GTLU0087 Thermostat Kit 200F-COTHERM. This genuine OEM replacement part is designed to ensure accurate temperature control in compatible Bunn equipment. Please read this manual thoroughly before proceeding with installation or operation.
2. Enfòmasyon sou Sekirite
WARNING: Risk of Electric Shock and Burns.
- Always disconnect power to the equipment before installing, servicing, or removing the thermostat.
- Enstalasyon ak sèvis yo ta dwe fèt sèlman pa pèsonèl kalifye.
- Asire w tout koneksyon fil yo byen fèm epi konfòm ak kòd elektrik lokal yo.
- The thermostat operates at high temperatures. Allow equipment to cool before handling components.
- Do not bypass or modify safety devices.
3. Pwodwi souview
The Bunn 4623-GTLU0087 Thermostat Kit 200F-COTHERM is a critical component for maintaining precise temperature within Bunn commercial beverage equipment. It is designed to regulate heating elements to achieve and maintain a target temperature of 200°F (93°C).

Figi 1: Bunn 4623-GTLU0087 Thermostat Kit. This image displays the complete thermostat kit, including the main control unit with electrical terminals, the temperature sensing bulb, and the capillary tube. The bulb is typically inserted into the liquid or air path to monitor temperature, and the capillary tube connects it to the control unit, which then activates or deactivates the heating element based on the set temperature.
4. Enstalasyon ak Enstalasyon
This thermostat kit is a direct replacement part. Refer to your specific Bunn equipment's service manual for detailed installation instructions. The following are general steps:
- Dekonekte pouvwa: Ensure the equipment is completely disconnected from its power source.
- Tèmosta Aksè: Locate and access the existing thermostat within the equipment. This may require removing panels or covers.
- Kablaj Dokiman: Carefully note or photograph the wiring connections to the old thermostat before removal.
- Retire ansyen tèmostat: Disconnect wires and carefully remove the old thermostat, including its sensing bulb and capillary tube.
- Enstale nouvo tèmosta a: Mount the new Bunn 4623-GTLU0087 thermostat in the same location. Ensure the sensing bulb is correctly positioned in the designated temperature-sensing area.
- Konekte fil elektrik: Reconnect the electrical wires to the new thermostat terminals, matching the documented configuration. Ensure all connections are tight and secure.
- Eleman sekirite: Ensure the capillary tube is routed without kinks or sharp bends and secured to prevent damage.
- Retabli pouvwa: Once installation is complete and all covers are replaced, restore power to the equipment.
- Operasyon tès: Verify proper function by monitoring the equipment's temperature and ensuring the thermostat cycles the heating element as expected.
5. Operasyon Enstriksyon
The Bunn 4623-GTLU0087 Thermostat is a fixed-temperature device, pre-calibrated to maintain a temperature of 200°F (93°C). It operates automatically to regulate the heating cycle of the connected equipment. There are no user-adjustable settings on this specific thermostat model.
- Upon power-up, the thermostat will sense the current temperature.
- If the temperature is below 200°F, the thermostat will engage the heating element.
- Once the temperature reaches 200°F, the thermostat will disengage the heating element.
- The thermostat will cycle on and off as needed to maintain the target temperature.
6. Antretyen
Regular inspection of the thermostat and its connections is recommended to ensure continued reliable operation.
- Enspeksyon vizyèl: Periodically inspect the thermostat, wiring, and capillary tube for any signs of damage, corrosion, or loose connections.
- Netwayaj: Ensure the area around the thermostat and sensing bulb is free from debris, dust, or buildup that could impede accurate temperature sensing. Disconnect power before cleaning.
- Tcheke fonksyonalite: If the equipment is not maintaining the correct temperature, or if the heating element is constantly on or off, the thermostat may require further inspection or replacement.
Note: Do not attempt to repair a faulty thermostat. Replace it with a genuine Bunn OEM part if it is not functioning correctly.
NAN. Depanaj
| Pwoblèm | Kòz posib | Solisyon |
|---|---|---|
| Equipment not heating | Pa gen kouran pou ekipman yo Eleman chofaj defo Termostat defo Koneksyon fil elektrik ki lach | Tcheke ekipman pou pouvwa Test heating element (qualified personnel) Test thermostat continuity (qualified personnel) Enspekte epi an sekirite fil elektrik |
| Equipment overheating | Faulty thermostat (stuck closed) Sensing bulb improperly seated | Ranplase tèmostat Ensure sensing bulb is correctly positioned |
| Tanperati enkonsistan | Sensing bulb not making good contact Thermostat cycling too frequently/infrequently | Verify sensing bulb placement Replace thermostat if cycling is abnormal |
If troubleshooting steps do not resolve the issue, contact a qualified service technician or the product manufacturer for assistance.
8. Espesifikasyon
- Nimewo Pati: 4623-GTLU0087
- Kalite: Twous Thermostat
- Anviwònman Tanperati: 200 ° F (93 ° C)
- Mak konpatibilite: Bunn
- Manifakti: Fits Bunn (OEM Part)
9. Enfòmasyon sou Garanti
As a genuine OEM part, this thermostat kit is typically covered by the original equipment manufacturer's warranty for replacement parts. Please refer to the warranty documentation provided with your Bunn equipment or contact the seller/manufacturer for specific warranty terms and conditions.
10. Sipò pou Kliyan
For technical assistance, replacement parts, or further inquiries regarding the Bunn 4623-GTLU0087 Thermostat Kit, please contact your authorized Bunn service provider or the original seller of the product. When contacting support, please have your equipment model number and the thermostat part number (4623-GTLU0087) available.