ZTYXUX ZS3-VA

ZTYXUX ZS3-VA Survoltage ak UndervoltagManyèl Itilizatè Disjonktè Pwoteksyon e

1. Entwodiksyon

This manual provides essential information for the safe and effective installation, operation, and maintenance of the ZTYXUX ZS3-VA Overvoltage ak Undervoltage Protection Circuit Breaker. This device is designed to protect electrical equipment from damage caused by abnormal voltage fluctuations and overcurrent conditions in AC 220V systems. Please read this manual thoroughly before use and retain it for future reference.

2. Enfòmasyon sou Sekirite

AVÈTISMAN: Electrical work should only be performed by qualified personnel. Failure to follow these safety instructions may result in electric shock, fire, or serious injury.

  • Always disconnect power to the circuit before installation, wiring, or maintenance.
  • Asire w tout koneksyon fil yo byen fèm epi konfòm ak kòd elektrik lokal yo.
  • Pa sèvi ak aparèy la si li sanble domaje.
  • Pa depase vol espesifye atage ak evalyasyon aktyèl aparèy la.
  • Kenbe aparèy la lwen dlo ak imidite twòp.

3. Pwodwi souview

The ZS3-VA is an intelligent protection device featuring a digital display for real-time voltage and current monitoring. It automatically disconnects the circuit when voltage or current exceeds user-defined safe limits and reconnects once conditions return to normal after a set delay. The device includes control buttons for parameter adjustment.

Devan view of the ZTYXUX ZS3-VA Overvoltage ak Undervoltage Protection Circuit Breaker

Figi 3.1: Devan view of the ZS3-VA protector, showing the digital display for voltage (red) and current (green), and control buttons (M, Up, Down, Power).

4. Espesifikasyon

ParamètValè
Rated Operating VoltageAC 220V
Rated aktyèl40A or 63A (model dependent)
OvervoltagRanje Pwoteksyon eAdjustable, typically 230V - 300V
UndervoltagRanje Pwoteksyon eAdjustable, typically 130V - 210V
Overcurrent Protection RangeAdjustable, typically 1A - 40A/63A
Tan reta rekiperasyon anAdjustable, typically 1 - 999 seconds
Montaj35mm DIN Rail
Dimensional drawing of the ZTYXUX ZS3-VA Overvoltage ak Undervoltage Protection Circuit Breaker

Figi 4.1: Dimensions of the ZS3-VA protector, showing measurements such as 86mm height, 38mm width, and 66mm depth.

5. Enstalasyon ak Enstalasyon

The ZS3-VA protector is designed for installation on a standard 35mm DIN rail. Ensure the installation location is dry, well-ventilated, and free from corrosive gases.

5.1 Enstriksyon fil elektrik

  1. Dekoneksyon pouvwa: Before starting, ensure the main power supply to the circuit is completely disconnected.
  2. Montaj: Snap the device onto a 35mm DIN rail securely.
  3. Fil elektrik Antre: Connect the incoming live (L) and neutral (N) wires to the 'IN' terminals of the protector. Ensure correct polarity.
  4. Fil elektrik Sòti: Connect the outgoing live (L) and neutral (N) wires to the 'OUT' terminals of the protector, which will lead to the load.
  5. Koneksyon an sekirite: Tighten all terminal screws firmly to prevent loose connections, which can cause overheating or malfunction.
  6. Retablisman pouvwa: Yon fwa tout koneksyon yo verifye, retabli kouran an nan sikwi a.
Side view of the ZTYXUX ZS3-VA protector showing input and output terminals

Figi 5.1: Side view of the ZS3-VA protector, illustrating the 'IN' (input) and 'OUT' (output) terminals for live (L) and neutral (N) connections.

6. Operasyon Enstriksyon

Upon power-up, the device will display real-time voltage and current. The red display shows voltage, and the green display shows current.

6.1 Fonksyon bouton

  • M bouton: Enters/exits parameter setting mode, cycles through parameters.
  • Bouton flèch moute: Increases parameter value.
  • Bouton flèch desann: Decreases parameter value.
  • Bouton Pouvwa (Wouj): Manually turns the output ON/OFF.

6.2 Anviwònman Paramèt

Pou ajiste paramèt pwoteksyon yo:

  1. Press and hold the 'M' button for approximately 3 seconds to enter the setting mode. The display will show the first adjustable parameter (e.g., 'P-1' for overvoltage papòt).
  2. Use the 'Up' and 'Down' arrow buttons to adjust the value of the displayed parameter.
  3. Press the 'M' button briefly to confirm the current setting and move to the next parameter (e.g., 'P-3' for undervoltage threshold, 'P-5' for overcurrent threshold, 't' for recovery delay time).
  4. Repeat step 2 and 3 for all desired parameters.
  5. After setting all parameters, press and hold the 'M' button again for 3 seconds to save the settings and exit the setting mode. If no button is pressed for a period, the device will automatically exit setting mode and save changes.

6.3 Display Modes and Fault Indication

The device continuously displays real-time voltage and current. In case of an overvoltage, undervoltage, or overcurrent event, the device will trip, disconnect the load, and display an error code or flashing indicator. After the fault clears and the set recovery delay time expires, the device will automatically reconnect the load.

Series of ZTYXUX ZS3-VA devices showing various display states and parameter settings

Figi 6.1: Examples of ZS3-VA display states, including 'ON' (normal operation), 'OFF' (manual shutdown), and parameter setting modes like 'P-1' (overvoltage), 'P-3' (undervoltage), and 'P-5' (overcurrent).

7. Antretyen

The ZS3-VA protector requires minimal maintenance. Follow these guidelines:

  • Netwayaj: Netwaye deyò aparèy la detanzantan avèk yon twal mou epi sèk. Pa sèvi ak pwodui netwayaj abrazif oswa solvan.
  • Tcheke Koneksyon: Annually inspect all wiring connections to ensure they remain tight and free from corrosion.
  • Kondisyon anviwònman: Asire w ke anviwònman operasyon an rete nan limit tanperati ak imidite espesifye yo.

NAN. Depanaj

PwoblèmKòz posibSolisyon
Aparèy pa limenPa gen ekipman pou kouran; fil elektrik ki pa kòrèkCheck main power supply; verify input wiring (L and N)
Frequent trippingProtection parameters set too low/high; unstable power supply; overloaded circuitAdjust overvoltage/undervoltage/overcurrent thresholds; consult an electrician to check power quality or load
Device trips but does not resetFault condition persists; recovery delay time too longVerify the fault condition has cleared; check recovery delay time setting
Display is blank or erraticInternal fault; power issueDisconnect power, wait a few minutes, then reconnect. If issue persists, contact support.

9. Garanti ak sipò

For warranty information and technical support, please refer to the documentation provided with your purchase or contact your retailer/manufacturer directly. Ensure you have your product model number (ZS3-VA) and purchase details available when seeking support.

Dokiman ki gen rapò - ZS3-VA

Preview VaneAims All-in-One Smart Protector with Auto-Reconnect: User Manual
Comprehensive user manual for the VaneAims All-in-One Smart Protector with Auto-Reconnect, detailing setup, technical specifications, and operational instructions for voltage and current protection.
Preview Energenie EG-AVR-1001 Otomatik AC Voltage Manyèl Itilizatè regilatè ak estabilize
Manyèl itilizatè pou Energenie EG-AVR-1001 Otomatik AC Vol latagRegilatè ak Estabilizatè. Karakteristik yo enkli AVR, pwodiksyon AC sinisoyidal pi, estati LED, ak pwoteksyon. Espesifikasyon, garanti, ak enfòmasyon sekirite yo bay.
Preview Gid Itilizatè Kamera ak Pakè Endoskop USB Vividia Ablescope
Gid sa a bay enfòmasyon sou Kamera ak Pakè Endoskop USB Vividia Ablescope yo, ki gen ladan karakteristik, avantaj, enstriksyon konfigirasyon, konpatibilite lojisyèl, opsyon pakè, ak prekosyon sekirite.
Preview SVC Automatic Voltage Stabilizers FL Series (600-5000 VA) User Manual
User manual for SVC Automatic Voltage Stabilizers, FL Series (600-5000 VA). Covers installation, connection, operation, technical specifications, and safety instructions for models FL-600, FL-1000, FL-1500, FL-2000, FL-3000, and FL-5000.
Preview Instrukcja Obsługi Pojemników Szklanych VacSy® Zepter
Kompletna instrukcja obsługi, wskazówki dotyczące użytkowania, konserwacji, bezpieczeństwa i gwarancji dla szklanych pojemników na żywność VacSy® firmy Zepter, wraz z danymiachcja techniczmi enfòmasyon.
Preview Intermatic T105 24-Hour Dial Time Switch: Installation, Wiring, and Operation Guide
Comprehensive guide for the Intermatic T105 24-hour mechanical dial time switch. Covers model specifications, safety warnings, wiring instructions for various configurations (SPNO, SPNC, SPDT), programming procedures, and manual operation. Includes a detailed table of electrical ratings and wire gauge recommendations.