1. Entwodiksyon
This manual provides detailed instructions for the installation, operation, and maintenance of the DIGITEN DHC312 Humidity Controller. This pre-wired digital humidistat is designed to regulate and maintain desired humidity levels in various environments, offering both humidification and dehumidification capabilities. It also features a real-time temperature display for comprehensive environmental management.

Image 1.1: The DIGITEN DHC312 Humidity Controller, showing the main unit, power outlet, power plug, and humidity sensor.
2. Pwodwi Features
- High-Precision Swiss-Imported Humidity Sensor: Regulates humidity within 5% to 99% RH with an accuracy of ±3%RH.
- Ekspozisyon tanperati an tan reyèl: Monitors ambient temperature (Note: The device measures temperature but does not control it).
- Convenient Plug & Play Operation: Non-programmable design for ease of use; no complex programming required.
- Intelligent Dual-Stage Kontwòl: Seamlessly switches between humidification and dehumidification modes. Requires humidifiers with automatic restart functions.
- Aplikasyon versatile: Suitable for home brewing, reptile habitats, greenhouses, mushroom cultivation, grow tents, meat drying, and incubation.
- Fonksyon adisyonèl: Supports switching between °C/°F, calibration, and compressor delay functions.

Imaj 2.1: Plis paseview of the DHC312 controller highlighting its key features such as large screen, dual-mode operation, and plug-and-play functionality.

Imaj 2.2: Detaye view of the high-precision Swiss-imported humidity sensor, emphasizing its compact design and internal components.
3. Pake kontni
The DIGITEN DHC312 Humidity Controller package includes the following items:
- 1 x DIGITEN DHC312 Humidity Controller Unit
- 1 x manyèl itilizatè

Image 3.1: The complete package contents, showing the main controller unit, the dual-outlet power strip, the humidity sensor, and the instruction manual.
4. Espesifikasyon
| Spesifikasyon | Valè |
|---|---|
| Nimewo Modèl | DHC312 |
| Kontwòl Range | 5-99% RH |
| Imidite Rezolisyon | 0.1% RH |
| Presizyon | ± 3% RH |
| Mòd kontwòl | Humidify or Dehumidify |
| Antre pouvwa | 100 ~ 240VAC, 50/60Hz |
| Relay Contact Capacity (Humidify) | 10A, 100~240VAC |
| Relay Contact Capacity (Dehumidify) | 10A, 100~240VAC |
| Sensor Lead Length | 2m / 6.56ft |
| D 'pouvwa kab longè | 150cm / 4.92ft |
| Sòti pouvwa kab longè | 18cm / 0.59ft |
| Koulè | Nwa |
| Materyèl | Plastik |
| Kalite ekspozisyon | Digital |
| Pwa atik | 15.8 ons |
| Dimansyon pake | 7.8 x 3.5 x 3.5 pous |

Image 4.1: Visual representation of the controller's dimensions and key technical specifications.
5. Enstriksyon Enstalasyon
The DIGITEN DHC312 is designed for plug-and-play convenience. Follow these steps for initial setup:
- Plasman: Position the main controller unit in a stable location.
- Koneksyon Capteur: Ensure the humidity sensor is securely connected to the main controller unit. Place the sensor probe in the environment where humidity needs to be monitored and controlled. Avoid placing it near direct airflow or heat sources for accurate readings.
- Koneksyon pouvwa: Plug the controller's power plug into a standard electrical outlet (100-240VAC).
- Appliance Connection:
- For humidification, plug your humidifier into the outlet labeled "HUMIDIFICATION" on the dual-stage power strip.
- For dehumidification, plug your dehumidifier or exhaust fan into the outlet labeled "DEHUMIDIFICATION".
Enpòtan: Ensure your humidifier has an automatic restart function for seamless operation with this controller.

Image 5.1: The dual-relay power strip connected to the controller, illustrating the separate outlets for humidification and dehumidification appliances.
6. Operasyon Enstriksyon
The DHC312 features a clear digital display and intuitive buttons for easy operation.
6.1 Ekspozisyon souview

Imaj 6.1: Detaye view of the controller's LCD screen, indicating various display elements such as current temperature, current humidity, and set humidity.
- Mòd travay: Indicates whether the unit is in humidification or dehumidification mode.
- Tanperati aktyèl: Displays the real-time ambient temperature.
- Current Humidity: Shows the real-time ambient humidity percentage.
- Setting Humidity (SET): Displays the target humidity percentage ou te mete.
- Difference (DIFF): Indicates the humidity differential setting.
- Calibration (CA): Indicates if calibration is active.
6.2 Fikse Imidite Sib la
- Peze a Up (▲) oswa Desann (▼) button to adjust the target humidity value (SET).
- After setting the desired value, wait approximately 5 seconds. The controller will automatically save the setting and return to the normal display mode.
6.3 Advanced Settings (Temperature Unit, Difference, Calibration)
- Long peze la SET button for 3 seconds until the °C or °F indicator flashes.
- While the indicator is flashing, short press the SET button to cycle through the advanced settings: Temperature Unit (°C/°F), Difference (DIFF), and Calibration (CA).
- Sèvi ak la Up (▲) oswa Desann (▼) buttons to adjust the value for the selected setting.
- Long peze la SET button for 3 seconds to save the changes and exit the advanced settings menu.

Image 6.2: Step-by-step guide on setting the target humidity and accessing advanced functions like °C/°F switching, difference, and calibration.
6.4 Humidification and Dehumidification Logic
The controller operates based on the set humidity value and the difference (DIFF) setting:
- Imidifikasyon: The humidification outlet turns ON when the measured humidity is ≤ (Setting Value - DIFF). It turns OFF when the measured humidity is ≥ Setting Value.
- Dezumidifikasyon: The dehumidification outlet turns ON when the measured humidity is ≥ (Setting Value + DIFF). It turns OFF when the measured humidity is ≤ Setting Value.

Imaj 6.3: Egzanpamples of the controller managing humidity in a greenhouse (humidification) and a poultry farm (dehumidification).
7. Kalibrasyon
The DHC312 allows for humidity calibration to ensure accuracy. If you have a trusted reference hygrometer, you can adjust the controller's reading.
- Access the advanced settings menu by long pressing the SET bouton pou 3 segonn.
- Kout peze la SET button until 'CA' (Calibration) is displayed.
- Sèvi ak la Up (▲) oswa Desann (▼) buttons to adjust the calibration value. This value will offset the measured humidity.
- Long peze la SET bouton pou 3 segonn pou sove epi sòti.
NAN. Depanaj
If you encounter issues with your DIGITEN DHC312, refer to the following common problems and solutions:
| Pwoblèm | Kòz posib | Solisyon |
|---|---|---|
| Ekspozisyon kontwolè a koupe. | Pa gen ekipman pou pouvwa. | Check if the power plug is securely inserted into a live outlet. Verify the outlet is functioning. |
| Inaccurate humidity readings. | Sensor dirty or improperly placed; calibration needed. | Clean the sensor gently. Relocate the sensor away from direct airflow or heat. Perform a calibration as described in Section 7. |
| Humidifier/Dehumidifier not activating. | Incorrect settings; appliance not working; appliance lacks auto-restart. | Verify the target humidity and DIFF settings. Ensure the appliance is plugged into the correct outlet and is functional. Confirm your appliance has an auto-restart function. |
| Ekspozisyon tanperati a pa kòrèk. | Sensor issue or environmental factors. | Ensure the sensor is not exposed to extreme temperatures or direct sunlight. The controller measures, but does not control, temperature. |
9. Antretyen
To ensure the longevity and accurate performance of your DIGITEN DHC312 Humidity Controller, follow these maintenance guidelines:
- Netwayaj: Periodically wipe the main unit and display with a soft, dry cloth. Do not use abrasive cleaners or immerse the unit in water.
- Swen Capteur: Keep the humidity sensor clean and free from dust, debris, or moisture buildup. Gently clean the sensor housing if necessary.
- Depo: If storing the controller for an extended period, disconnect it from power, clean it, and store it in a cool, dry place away from direct sunlight and extreme temperatures.
- Kondisyon anviwònman: Avoid exposing the controller to corrosive gases, high humidity (beyond its operating range), or extreme temperatures, which can affect its performance and lifespan.
10. Garanti ak sipò
DIGITEN provides a one-year warranty for any quality problems encountered with this product. For technical support, warranty claims, or further assistance, please contact DIGITEN customer service through your purchase platform or the official DIGITEN websit.
For more information about DIGITEN products, please visit the DIGITEN Store.