Manyèl Itilizatè Sistèm Ponp Chalè Santral Envèseur ACiQ 2.5 Tòn 17 SEER2

Model: B0DHFF2DKL

1. Entwodiksyon

This manual provides essential information for the installation, operation, and maintenance of your ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System. This system is designed to provide efficient heating and cooling for residential and light commercial applications. Please read this manual thoroughly before attempting any installation or operation to ensure proper function and safety.

2. Enfòmasyon sou Sekirite

Always prioritize safety. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. Consult a qualified installer, service agency, or the gas supplier for information or assistance. The information contained in this manual is intended for use by qualified service personnel only.

  • Sekirite elektrik: Ensure the power supply is disconnected before performing any service or maintenance. All electrical wiring must comply with local and national electrical codes.
  • Manyen frijidè: This system uses R-454B refrigerant. Only certified technicians should handle refrigerants.
  • Enstalasyon: Enstalasyon an dwe fèt pa yon pwofesyonèl HVAC ki gen lisans.
  • Ekipman Pwoteksyon Pèsonèl: Always wear appropriate personal protective equipment (PPE) such as gloves and safety glasses during installation and maintenance.

3. Karakteristik kle

  • Teknoloji varyateur: Provides precise temperature control, reduced energy consumption, and quieter operation.
  • Segondè efikasite: 18.8 SEER2 and 9.7 HSPF2 ratings for energy savings.
  • Lajè ranje operasyon: Reliable performance from -13°F to 122°F.
  • Operasyon trankil: Indoor noise levels as low as 44 dBA, outdoor unit at 60 dBA.
  • Eleman dirab: Rotary compressor, aluminum coil, and fiberglass-free insulation.
  • Refrijeran ekolojik-zanmi: Utilizes R-454B refrigerant.
  • Enstalasyon fleksib: Supports horizontal and vertical air handler installation.
  • Kontwòl entelijan: Compatible with wired controllers, WiFi, and third-party thermostats.
  • Integrated Back-up Heat: Includes a 10kW back-up heat kit for supplemental heating.

4. Konpozan souview

The ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System includes the following main components:

  • Outdoor Condensing Unit (Heat Pump)
  • Indoor Air Handler Unit
  • 10kW Back-up Heat Kit
  • 30' Line Set
  • Gauge Electrical Whip
  • 60A Non-Fused Disconnect Switch
  • WiFi Thermostat
  • Pwotèksè
  • CPS Charging Adapter
  • Mi manch
ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System components

Figi 1: Plis paseview of the ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System, showing the outdoor unit, indoor air handler, 10kW back-up heat kit, thermostat, line set, and various installation accessories.

5. Enstalasyon ak Enstalasyon

Installation of this ACiQ heat pump system requires specialized knowledge and tools. It must be performed by a qualified and licensed HVAC technician to ensure safety, compliance with local codes, and optimal performance. Refer to the detailed installation manual provided with the product for specific instructions.

5.1 Chèk Pre-Enstalasyon

  • Verify that the electrical supply matches the unit's requirements (Indoor: 115/208/230V, 60Hz, 1Ph; Outdoor: 208/230V, 60Hz, 1Ph).
  • Asire ase espas pou inite andedan ak deyò yo, pou pèmèt bon sikilasyon lè ak aksè pou antretyen.
  • Confirm that the maximum piping length (164 ft / 50m) and height difference (82 ft / 25m) are not exceeded.

5.2 Air Handler Installation

The indoor air handler unit is designed for flexible installation, supporting upflow, downflow, and horizontal configurations to suit various space requirements.

Multi-Positional Air Handler Unit installation options

Figi 2: Diagram illustrating the multi-positional capabilities of the indoor air handler unit, showing options for upflow, downflow, and horizontal installation.

5.3 Outdoor Unit Placement

Consider the outdoor unit's dimensions and required clearances for optimal performance and maintenance. The unit features a compact design compared to traditional systems.

Outdoor unit size comparison with traditional units

Figi 3: Graphic comparing the smaller footprint of the ACiQ outdoor unit (20 inches clearance) versus a traditional unit (36 inches clearance), highlighting its high efficiency and self-cleaning features.

6. Operasyon Enstriksyon

Your ACiQ heat pump system offers advanced control options for comfortable and efficient operation.

6.1 Mòd Operasyon Debaz yo

  • Mòd refwadisman: Provides cooling with a capacity of 31,000 BTU/hr. Operates efficiently from -13°F to 122°F ambient temperatures.
  • Mòd chofaj: Provides heating with a capacity of 30,000 BTU/hr at 47°F. Reliable warmth down to -13°F. The 10kW back-up heat kit provides supplemental heat when needed.
  • Mòd fanatik: Fè lè sikile san li pa chofe ni refwadi.
  • Mòd oto: Chanje otomatikman ant chofaj ak refwadisman pou kenbe tanperati ki fikse a.
ACiQ outdoor unit operating in extreme heat

Figi 4: The ACiQ outdoor unit installed on a patio, demonstrating its ability to operate effectively in extreme heat conditions, up to 122°F.

ACiQ outdoor unit operating in extreme cold

Figi 5: The ACiQ outdoor unit partially covered in snow, illustrating its capability to operate in extreme cold temperatures, down to -13°F.

6.2 Smart Controls

The system can be controlled via the included wired thermostat, WiFi-enabled app, or compatible third-party thermostats. The WiFi app allows for remote control and monitoring of your system.

ACiQ Smart Home app and wired thermostat

Figi 6: Image showing the ACiQ Smart Home mobile application interface on a smartphone alongside a wired thermostat, demonstrating the system's smart control capabilities for climate management.

7. Antretyen

Regular maintenance ensures the longevity and efficiency of your ACiQ heat pump system. Always disconnect power before performing any maintenance.

  • Ranplasman filtè lè: Check and replace air filters in the indoor air handler every 1-3 months, or more frequently if needed. Dirty filters restrict airflow and reduce efficiency.
  • Netwayaj Inite Eksteryè a: Keep the outdoor unit free from debris, leaves, and dirt. Periodically clean the coils with a soft brush or water hose (ensure power is off).
  • Sistèm drenaj: Ensure the condensate drain line is clear and free of blockages to prevent water overflow.
  • Enspeksyon pwofesyonèl: Schedule annual inspections and maintenance by a qualified HVAC technician.

NAN. Depanaj

This section provides solutions for common issues. For complex problems, contact a qualified HVAC technician.

  • Pa gen pouvwa: Check circuit breakers and ensure the disconnect switch is in the ON position.
  • Chofaj/Refwadisman ensifizan: Verify thermostat settings, check air filters for blockage, and ensure outdoor unit is not obstructed.
  • Bwi ki pa nòmal: Minor operational noises are normal. Loud or unusual noises may indicate a problem requiring professional inspection.
  • Dlo koule: Check condensate drain line for blockages.

9. Espesifikasyon

Dimensions of ACiQ indoor and outdoor units

Figi 7: Image displaying the dimensions of both the indoor air handler unit (49.02" H x 21.02" W x 21.02" D) and the outdoor condensing unit (35.04" H x 37.24" W x 16.14" D).

Cooling capacity chart for ACiQ heat pump

Figi 8: Chart detailing the cooling capacity of the ACiQ system at various outdoor temperatures: 86°F (118% capacity), 95°F (113% capacity), 110°F (99% capacity), and 122°F (48% capacity).

Heating capacity chart for ACiQ heat pump

Figi 9: Chart detailing the heating capacity of the ACiQ system at various outdoor temperatures: -22°F (N/A), -13°F (41% capacity), 0°F (57% capacity), 17°F (70% capacity), and 32°F (73% capacity).

KarakteristikDetay
Kapasite refwadisman31,000 BTU/h
Kapasite chofaj30,000 BTU/hr (at 47°F)
Evalyasyon SEER218.8
Evalyasyon HSPF29.7
Kalite febrifujR-454B
Andedan kay la Inite Power Supply115/208/230V, 60Hz, 1Ph
Alimantasyon pou inite deyò a208/230V, 60Hz, 1Ph
Max Piping Longè164 pye (50m)
Diferans wotè maksimòm82 pye (25m)
Indoor Unit Dimensions (W × D × H)21.02" × 21.02" × 49.02"
Outdoor Unit Dimensions (W × D × H)37.24" × 16.14" × 31.89"
Pwa nèt inite andedan an128.97 liv
Pwa nèt inite deyò a164.02 liv

10. Garanti ak sipò

ACiQ offers a comprehensive warranty for this heat pump system:

  • Pati garanti: 7 ane
  • Garanti compressor: 12 ane

These warranty terms are valid when the system is installed by a certified technician and registered online with the manufacturer. For technical support, service inquiries, or warranty claims, please refer to the contact information provided in your product packaging or visit the official ACiQ websit.

Dokiman ki gen rapò - B0DHFF2DKL

Preview ACiQ 9K-24K Standard Heat Single-Zone Systems: Installation & Owner's Manual
ACiQ 9K-24K Standard Heat Single-Zone Systems Installation & Owner's Manual. This guide details installation, operation, safety, and maintenance for ACiQ air conditioners, including model specifics and R454B refrigerant information.
Preview ACiQ Central Inverter Systems Installation Manual
Comprehensive installation manual for ACiQ Central Inverter Air Conditioning and Heat Pump Systems, detailing safety precautions, refrigerant piping, outdoor unit installation, wiring, power specifications, air evacuation, and test run procedures.
Preview ACiQ Wall-Mounted Air Handler & Extreme Heat Single-Zone Condenser Installation & Owner's Manual
This manual provides detailed installation, operation, and safety guidelines for ACiQ wall-mounted air handlers and extreme heat single-zone condensers, covering models ACIQ-06W-HH-MD through ACIQ-24ZPL-HP230C.
Preview ACiQ Central Inverter Systems Outdoor Unit Installation Manual
Comprehensive installation manual for ACiQ Central Inverter Systems outdoor units, covering safety precautions, refrigerant piping, wiring, unit installation, and testing procedures for models like ACiQ-18-AC, ACiQ-24-AC, ACiQ-18-EHPB, and others.
Preview ACiQ Next Gen Ducted Heat Pump System: Quick Start Guide for Thermostat Wiring
This guide provides essential information for connecting and wiring thermostats to the ACiQ Next Gen Ducted Heat Pump System. It details recommended and alternative connection options, including DIP switch settings and terminal block configurations for various thermostat types.
Preview ACiQ Essentials Mini-Split Air Handler & Condenser Installation and Owner's Manual
Comprehensive installation and owner's manual for ACiQ Essentials Mini-Split Air Handler and Condenser systems, covering safety precautions, parts identification, remote control operation, installation procedures, test runs, maintenance, and troubleshooting for various models. The manual also includes critical information regarding the servicing of systems using flammable refrigerant R454B, emphasizing safety protocols and regulatory compliance. It is designed for professional installers and end-users to ensure safe and efficient operation of ACiQ mini-split heat pump systems.