1. Entwodiksyon
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your ACiQ 4 Ton 15.5 SEER2 High Efficiency Central Air Conditioner System. Please read this manual thoroughly before installation and use, and retain it for future reference. Proper installation and maintenance are crucial for optimal performance and longevity of the unit.
2. Enfòmasyon sou Sekirite
Enstriksyon enpòtan pou sekirite:
- Installation and servicing must be performed by a qualified HVAC technician. Improper installation can result in electric shock, fire, or water leakage.
- Asire w ke aparèy la byen konekte atè pou anpeche chòk elektrik.
- Turn off all power to the unit before performing any maintenance or servicing.
- Do not block the air intake or outlet of the outdoor or indoor units.
- Use only specified refrigerants (R410A) and follow all environmental regulations.
- Kenbe timoun ak bèt kay lwen inite deyò a pandan l ap fonksyone.
3. Pwodwi souview ak Karakteristik
The ACiQ 4 Ton 15.5 SEER2 Central Air Conditioner System is designed for high-efficiency cooling, featuring inverter technology for precise temperature control and energy savings. This system includes an outdoor condenser, an indoor multi-positional evaporator cased coil, and a comprehensive installation kit.
Karakteristik kle:
- Inverter AC Technology: Adjusts compressor speed for optimal temperature control, reduced energy consumption, and quieter operation.
- Multi-Positional Cased Coil: Factory-integrated TXV ensures efficient operation and flexibility in various installation configurations, enhancing HVAC performance.
- Segondè efikasite: 15.5 SEER2 rating for significant energy savings.
- Konstriksyon dirab: Features a Gold Fin condenser coil for enhanced corrosion resistance and longevity.
- Operasyon trankil: Engineered for ultra-quiet performance, with a noise level of 56 dB.
- Capteur entelijan: Integrated smart sensors for intelligent operation and performance monitoring.
- All-Climate Performance: Designed to operate effectively across a wide range of outdoor temperatures.
- Deteksyon koule: System includes alerts for refrigerant leaks to prevent hazards.
Eleman ki enkli:
The complete system includes the following components:
- Inite Kondansasyon Deyò
- Indoor Multi-Positional Evaporator Cased Coil
- Smart WiFi Thermostat
- 50' Insulated Line Set (3/8" LL x 3/4" SL x 3/8")
- 1/2" x 6' 10 Gauge Electrical Whip
- 60A Non-fused Disconnect Switch
- Controls Surge Protector
- CPS Charging Adapter
- Mi manch
- Mi Mount Support
- Manyèl Itilizatè (dokiman sa a)

Figi 3.1: Plis paseview of the ACiQ 4 Ton Central Air Conditioner System, showing the outdoor condenser, indoor evaporator coil, smart thermostat, and various installation kit components.

Figi 3.2: Detaye view of the ACiQ Split System Installation Kit, including the insulated line set, electrical whip, disconnect switch, surge protector, and smart thermostat.

Figi 3.3: Close-up of the ACiQ outdoor condenser unit, highlighting its robust construction and fan design.
4. Enstalasyon ak Enstalasyon
Enstalasyon pwofesyonèl obligatwa: Due to the complexity of HVAC systems, installation and initial setup of this ACiQ unit must be performed by a certified and qualified HVAC technician. Attempting to install the system without proper training and tools can lead to property damage, personal injury, and void the product warranty.
The installation process typically involves:
- Seleksyon sit: Choosing appropriate locations for the outdoor condenser and indoor evaporator coil, ensuring adequate airflow and drainage.
- Mounting Units: Securely mounting the outdoor condenser (using the provided wall mount bracket if applicable) and positioning the indoor evaporator coil.
- Koneksyon Liy Frijidè: Connecting the insulated line set between the indoor and outdoor units, ensuring proper brazing and leak testing.
- Fil elektrik: Connecting the electrical whip, disconnect switch, and surge protector according to local electrical codes and the unit's wiring diagram.
- Drenaj kondansasyon: Installing proper drainage for the indoor evaporator coil.
- Vacuum and Charging: Evacuating the refrigerant lines and charging the system with the correct amount of R410A refrigerant.
- Enstalasyon Thermostat: Wiring and configuring the Smart WiFi Thermostat.
- Tès sistèm: Performing a comprehensive test run to ensure all components are functioning correctly and efficiently.
Refer to the detailed installation guide provided to your HVAC technician for specific instructions and diagrams.
5. Operasyon Enstriksyon
Your ACiQ system is controlled by the included Smart WiFi Thermostat. Once installed and configured by a professional, operating the system is straightforward.
Smart WiFi Thermostat Operation:
The thermostat allows you to control various aspects of your air conditioning system. Consult the separate thermostat user manual for detailed instructions on its specific features, including:
- Seleksyon mòd: Switch between cooling, fan-only, or off modes.
- Anviwònman Tanperati: Adjust the desired indoor temperature.
- Orè: Program daily or weekly temperature schedules for energy efficiency.
- Kontwòl vitès fanatik: Adjust fan speed (if applicable).
- Koneksyon: Connect to your home WiFi network for remote control via a smartphone app and integration with smart home systems (e.g., Alexa, Google Home, SmartThings, IFTTT).
- Siveyans imidite: View indoor humidity levels.
- Estati sistèm: Monitor current indoor temperature, cooling set point, and system operational status.

Figi 5.1: Diagram illustrating the features and interface of the Smart WiFi Thermostat, including mode, humidity, temperature settings, and connectivity options.
For optimal performance, set the thermostat to a comfortable temperature and avoid frequent, drastic changes. The inverter technology will maintain the set temperature efficiently.
6. Antretyen
Regular maintenance is essential to ensure the longevity, efficiency, and optimal performance of your ACiQ air conditioning system. Some maintenance tasks can be performed by the homeowner, while others require a qualified technician.
Antretyen Itilizatè (Chak mwa/Chak trimès):
- Netwaye oswa ranplase filtè lè yo: Check and clean or replace the air filters in your indoor unit (or furnace/air handler, if applicable) monthly, or more frequently if the system is used heavily or in dusty environments. The system uses washable, reusable mesh filters.
- Klè Inite Eksteryè: Ensure the outdoor condenser unit is free from debris, leaves, grass clippings, and other obstructions that could block airflow. Keep vegetation trimmed around the unit.
- Check Condensate Drain: Tcheke tiyo drenaj kondansasyon an detanzantan pou wè si gen blokaj. Yon drenaj bouche ka lakòz dlo debòde.
Antretyen Pwofesyonèl (Chak ane):
It is highly recommended to schedule annual maintenance with a qualified HVAC technician. This typically includes:
- Cleaning of condenser and evaporator coils.
- Tcheke nivo ak presyon frijidè a.
- Enspekte koneksyon elektrik ak konpozan yo.
- Lubrifyan pati k ap deplase yo (si sa aplikab).
- Tcheke kalibrasyon tèmosta a.
- Enspekte kanalizasyon yo pou flit.
- Verifying proper system operation and performance.
NAN. Depanaj
Anvan ou kontakte yon teknisyen sèvis, review the following common issues and their potential solutions. For complex problems, always consult a qualified HVAC professional.
| Pwoblèm | Kòz posib | Solisyon |
|---|---|---|
| System Not Cooling |
|
|
| Fèb Airflow |
|
|
| Bwi etranj |
|
|
| Water Leakage (Indoor Unit) |
|
|
If the problem persists after attempting these solutions, or if you encounter any other issues, contact a qualified HVAC service technician.
8. Espesifikasyon
Detailed technical specifications for the ACiQ 4 Ton 15.5 SEER2 Central Air Conditioner System:
| Spesifikasyon | Valè |
|---|---|
| Mak | ACiQ |
| Nimewo Modèl | ACiQ-48-AC / ACIQ-60-ACL / IKIC51 |
| Kapasite | 4 Tons (48,000 BTU/h) |
| Efikasite (SEER2) | 15.5 VWA 2 |
| Kalite febrifuj | R410A |
| Voltage | 230 Volts |
| Wattage | 4000 wat |
| Nivo bri | 56 dB |
| Outdoor Unit Dimensions (D x W x H) | 16.14" x 37.24" x 52.48" |
| Indoor Coil Dimensions (W x D x H) | 24.49" x 20.98" x 27.99" (622 x 533 x 711 mm) |
| Kalite enstalasyon | Sistèm Split |
| Faktè fòm | Central Split System |
| Kalite filtre | Washable, Reusable Mesh Filter |
| Kouvèti zòn etaj | Apeprè 2400 pye kare |
| Karakteristik espesyal | Inverter Unit, Smart Sensors, Gold Fin Coil, Ultra-Quiet, All-Climate Performance |

Figi 8.1: Dimensional measurements for the ACiQ outdoor condenser unit and the indoor evaporator coil.

Figi 8.2: Detailed specifications for the ACiQ evaporator coil, including air flow, pressure, dehumidification, and dimensions.

Figi 8.3: AHRI (Air-Conditioning, Heating, and Refrigeration Institute) certification details and EnergyGuide label, confirming the system's efficiency rating.
9. Garanti ak sipò
Kondisyon garanti: The ACiQ system comes with a 7 ane garanti pati ak yon 12-ane garanti COMPRESSOR. This warranty is valid when the unit is installed by a qualified technician and registered online with the manufacturer. Please ensure your installer registers the product to activate the full warranty coverage.
Sipò Kliyan: For technical assistance, warranty claims, or to locate a certified service provider, please refer to the contact information provided on the ACiQ official websit la oswa dokiman ki vini ak acha ou a. Ou kapab vizite tou ACiQ Store on Amazon pou plis enfòmasyon.