ACiQ ACiQ-48-AC

Manyèl Itilizatè Sistèm Èkondisyone Santral ACiQ 4 Tòn 15.5 SEER2

Model: ACiQ-48-AC / ACIQ-60-ACL / IKIC51

1. Entwodiksyon

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your ACiQ 4 Ton 15.5 SEER2 High Efficiency Central Air Conditioner System. Please read this manual thoroughly before installation and use, and retain it for future reference. Proper installation and maintenance are crucial for optimal performance and longevity of the unit.

2. Enfòmasyon sou Sekirite

Enstriksyon enpòtan pou sekirite:

3. Pwodwi souview ak Karakteristik

The ACiQ 4 Ton 15.5 SEER2 Central Air Conditioner System is designed for high-efficiency cooling, featuring inverter technology for precise temperature control and energy savings. This system includes an outdoor condenser, an indoor multi-positional evaporator cased coil, and a comprehensive installation kit.

Karakteristik kle:

Eleman ki enkli:

The complete system includes the following components:

ACiQ 4 Ton Central Air Conditioner System components

Figi 3.1: Plis paseview of the ACiQ 4 Ton Central Air Conditioner System, showing the outdoor condenser, indoor evaporator coil, smart thermostat, and various installation kit components.

ACiQ Split System Installation Kit components

Figi 3.2: Detaye view of the ACiQ Split System Installation Kit, including the insulated line set, electrical whip, disconnect switch, surge protector, and smart thermostat.

ACiQ Air Conditioner Condenser Unit Features

Figi 3.3: Close-up of the ACiQ outdoor condenser unit, highlighting its robust construction and fan design.

4. Enstalasyon ak Enstalasyon

Enstalasyon pwofesyonèl obligatwa: Due to the complexity of HVAC systems, installation and initial setup of this ACiQ unit must be performed by a certified and qualified HVAC technician. Attempting to install the system without proper training and tools can lead to property damage, personal injury, and void the product warranty.

The installation process typically involves:

  1. Seleksyon sit: Choosing appropriate locations for the outdoor condenser and indoor evaporator coil, ensuring adequate airflow and drainage.
  2. Mounting Units: Securely mounting the outdoor condenser (using the provided wall mount bracket if applicable) and positioning the indoor evaporator coil.
  3. Koneksyon Liy Frijidè: Connecting the insulated line set between the indoor and outdoor units, ensuring proper brazing and leak testing.
  4. Fil elektrik: Connecting the electrical whip, disconnect switch, and surge protector according to local electrical codes and the unit's wiring diagram.
  5. Drenaj kondansasyon: Installing proper drainage for the indoor evaporator coil.
  6. Vacuum and Charging: Evacuating the refrigerant lines and charging the system with the correct amount of R410A refrigerant.
  7. Enstalasyon Thermostat: Wiring and configuring the Smart WiFi Thermostat.
  8. Tès sistèm: Performing a comprehensive test run to ensure all components are functioning correctly and efficiently.

Refer to the detailed installation guide provided to your HVAC technician for specific instructions and diagrams.

5. Operasyon Enstriksyon

Your ACiQ system is controlled by the included Smart WiFi Thermostat. Once installed and configured by a professional, operating the system is straightforward.

Smart WiFi Thermostat Operation:

The thermostat allows you to control various aspects of your air conditioning system. Consult the separate thermostat user manual for detailed instructions on its specific features, including:

Smart WiFi Thermostat features and interface

Figi 5.1: Diagram illustrating the features and interface of the Smart WiFi Thermostat, including mode, humidity, temperature settings, and connectivity options.

For optimal performance, set the thermostat to a comfortable temperature and avoid frequent, drastic changes. The inverter technology will maintain the set temperature efficiently.

6. Antretyen

Regular maintenance is essential to ensure the longevity, efficiency, and optimal performance of your ACiQ air conditioning system. Some maintenance tasks can be performed by the homeowner, while others require a qualified technician.

Antretyen Itilizatè (Chak mwa/Chak trimès):

Antretyen Pwofesyonèl (Chak ane):

It is highly recommended to schedule annual maintenance with a qualified HVAC technician. This typically includes:

NAN. Depanaj

Anvan ou kontakte yon teknisyen sèvis, review the following common issues and their potential solutions. For complex problems, always consult a qualified HVAC professional.

PwoblèmKòz posibSolisyon
System Not Cooling
  • Thermostat mete mal
  • Filtè lè sal
  • Outdoor unit obstructed
  • Pwoblèm ekipman pou pouvwa
  • Refrigerant leak (system alert)
  • Check thermostat settings (mode, temperature).
  • Netwaye oswa ranplase filtè lè a.
  • Clear debris from outdoor unit.
  • Check circuit breaker; ensure disconnect switch is ON.
  • Kontakte yon teknisyen kalifye pou enspeksyon ak reparasyon.
Fèb Airflow
  • Filtè lè sal
  • Ti vantilasyon retou bloke
  • Pwoblèm kanalizasyon
  • Netwaye oswa ranplase filtè lè a.
  • Ensure all return air vents are open and unobstructed.
  • Consult a technician to inspect ductwork.
Bwi etranj
  • Pati ki lach
  • Debri nan vantilatè a
  • Pwoblèm motè
  • Turn off unit and inspect for loose panels or debris.
  • If noise persists or is severe, contact a technician.
Water Leakage (Indoor Unit)
  • Tiyo drenaj kondansasyon bouche
  • Frozen evaporator coil
  • Clear the condensate drain line.
  • Turn off cooling and allow coil to defrost; check airflow and refrigerant levels. Contact technician if problem persists.

If the problem persists after attempting these solutions, or if you encounter any other issues, contact a qualified HVAC service technician.

8. Espesifikasyon

Detailed technical specifications for the ACiQ 4 Ton 15.5 SEER2 Central Air Conditioner System:

SpesifikasyonValè
MakACiQ
Nimewo ModèlACiQ-48-AC / ACIQ-60-ACL / IKIC51
Kapasite4 Tons (48,000 BTU/h)
Efikasite (SEER2)15.5 VWA 2
Kalite febrifujR410A
Voltage230 Volts
Wattage4000 wat
Nivo bri56 dB
Outdoor Unit Dimensions (D x W x H)16.14" x 37.24" x 52.48"
Indoor Coil Dimensions (W x D x H)24.49" x 20.98" x 27.99" (622 x 533 x 711 mm)
Kalite enstalasyonSistèm Split
Faktè fòmCentral Split System
Kalite filtreWashable, Reusable Mesh Filter
Kouvèti zòn etajApeprè 2400 pye kare
Karakteristik espesyalInverter Unit, Smart Sensors, Gold Fin Coil, Ultra-Quiet, All-Climate Performance
Dimensions of ACiQ outdoor condenser and indoor evaporator coil

Figi 8.1: Dimensional measurements for the ACiQ outdoor condenser unit and the indoor evaporator coil.

Specifications for ACiQ evaporator coil

Figi 8.2: Detailed specifications for the ACiQ evaporator coil, including air flow, pressure, dehumidification, and dimensions.

AHRI Rating Conditions and EnergyGuide label for ACiQ system

Figi 8.3: AHRI (Air-Conditioning, Heating, and Refrigeration Institute) certification details and EnergyGuide label, confirming the system's efficiency rating.

9. Garanti ak sipò

Kondisyon garanti: The ACiQ system comes with a 7 ane garanti pati ak yon 12-ane garanti COMPRESSOR. This warranty is valid when the unit is installed by a qualified technician and registered online with the manufacturer. Please ensure your installer registers the product to activate the full warranty coverage.

Sipò Kliyan: For technical assistance, warranty claims, or to locate a certified service provider, please refer to the contact information provided on the ACiQ official websit la oswa dokiman ki vini ak acha ou a. Ou kapab vizite tou ACiQ Store on Amazon pou plis enfòmasyon.

Dokiman ki gen rapò - ACiQ-48-AC

Preview ACiQ Central Inverter Systems Outdoor Unit Installation Manual
Comprehensive installation manual for ACiQ Central Inverter Systems outdoor units, covering safety precautions, refrigerant piping, outdoor unit installation, wiring, power specifications, air evacuation, and test run procedures. Includes model details and important notes for proper setup.
Preview ACiQ Central Inverter Systems Installation Manual
Comprehensive installation manual for ACiQ Central Inverter Air Conditioning and Heat Pump Systems, detailing safety precautions, refrigerant piping, outdoor unit installation, wiring, power specifications, air evacuation, and test run procedures.
Preview ACiQ Central Inverter Systems Outdoor Unit Installation Manual
Comprehensive installation manual for ACiQ Central Inverter Systems outdoor units, covering safety precautions, refrigerant piping, wiring, unit installation, and testing procedures for models like ACiQ-18-AC, ACiQ-24-AC, ACiQ-18-EHPB, and others.
Preview ACiQ R32 Unitary Air Handler & Heat Pump Condenser Technical Sales Guide
This technical sales guide provides detailed specifications, performance data, dimensions, and wiring diagrams for the ACiQ R32 Unitary Air Handler and Heat Pump Condenser series, covering models ACiQ-24/36/48/60-AH32 and ACiQ-24/36/48/60-HP32.
Preview Manyèl Enstalasyon Sistèm Manipulatè Lè ACiQ ak Konduit (12K-60K BTU/h)
Manyèl enstalasyon sa a soti nan ACiQ bay enstriksyon detaye pou enstalasyon an sekirite ak kòrèk inite Ducted Air Handler yo, modèl 12K jiska 60K BTU/h. Li kouvri direktiv sekirite esansyèl yo, plasman inite a, tiyo refrijeran, fil elektrik, espesifikasyon, ak tès operasyonèl pou asire pèfòmans optimal ak lonjevite sistèm nan.
Preview Gid pou kòmanse rapid sistèm ponp chalè ACiQ Next Gen Ducted la
Gid demaraj rapid pou Sistèm Ponp Chalè ACiQ Next Gen Ducted la, ki kouvri dyagram fil elektrik, koneksyon tèmosta, ak paramèt switch DIP pou divès senaryo enstalasyon.