This manual provides detailed instructions for the setup, operation, and maintenance of the Elitech Loget 260-TH 4G Real-time Temperature Humidity Data Logger. This device is designed for monitoring temperature, humidity, light, shock, and location in various cold chain applications, providing real-time data transmission via 4G network.
1.1. Pake kontni
- Elitech Loget 260-TH Data Logger (Reusable version)
- Kat SIM 4G entegre
- Manyèl itilizatè
- USB Kalite-C kab
2. Pwodwi souview
The Loget 260-TH is a multi-sensor data logger equipped with a display and control buttons for easy interaction. It features internal sensors for temperature, humidity, light, and shock, along with LBS (Location-Based Service) for location tracking.

Figure 2.1: Elitech Loget 260-TH Data Logger with numbered components.
2.1. Idantifikasyon konpozan
- Ekran LCD Display: Shows current readings, status, and alerts.
- Limyè endikatè ki ap dirije: Provides visual status updates (e.g., OK, Alarm).
- Activate/Airplane Mode Button: Used to activate the device or toggle airplane mode.
- Entèn sensor: Measures ambient temperature and humidity.
- Back Hanging Hole: For mounting or securing the device.
- Kòmanse / Stop bouton: Initiates or terminates data logging.
- Nimewo seri: Unique identifier for the device.
- Capteur limyè: Detects ambient light levels.
- Data Transmission Indicator: Shows network activity and data upload status.
2.2. Karakteristik kle
- Doub Sekirite Done: Features offline storage for up to 100,000 points to prevent data loss and supports shadow data recording for continuous monitoring even if logging is mistakenly stopped.
- Deteksyon plizyè sous: Monitors internal temperature (-30~60℃), humidity (0~100%RH), light (0~52000Lux), shock (0g~16g), and location (LBS). Optional external sensors for pH value or CO2 are available separately.
- Remote Monitoring via APP/Web: Real-time data is uploaded to the Elitech iCold Cloud platform via a built-in 4G SIM card. Upload intervals are configurable from 1 minute to 24 hours.
- Sistèm Alam Konplè: Cloud-based alarms can be received via Elitech iCold APP, SMS, Email, or the web platfòm. Aparèy la bay tou son lokal, ekran, ak alam limyè endikatè pou evènman offline.
- Auto Flight Mode & Electronic Fence: Complies with Do160 for aviation safety. Flight mode can be activated manually, scheduled, or automatically via an electronic fence (custom area activation).
- iCold Platform: A cloud-based platform compatible with RCW series products for real-time monitoring, automatic alerts, online data analysis, and management. It complies with FDA CFR 21 Part 11 requirements and supports iOS and Android apps.
3. Enstalasyon
3.1. Premye Chajman
Before first use, connect the Loget 260-TH to a power source using the provided USB Type-C cable and a standard USB charger (not included) to ensure the internal battery is fully charged. The battery indicator on the LCD will show charging status.
3.2. Device Activation and Platform Connection
- Pouvwa sou: Press and hold the 'Start/Stop' button for a few seconds until the device powers on and the LCD screen illuminates.
- Rezo Koneksyon: The built-in 4G SIM card will automatically attempt to connect to the network. The signal strength indicator on the LCD will show connection status.
- iCold Account Setup:
- Download the Elitech iCold APP from your mobile app store or visit the Elitech iCold web platfòm (http://new.i-elitech.com).
- Enskri pou yon nouvo kont oubyen konekte si ou deja genyen youn.
- Add your Loget 260-TH device to your account using the serial number found on the device (refer to Figure 2.1, item 7).
- Konfigirasyon: Once added, you can configure logging parameters such as upload interval, alarm thresholds, and sensor settings via the iCold platform.
4. Operasyon Enstriksyon
4.1. Kòmanse epi sispann anrejistreman anrejistreman
- Kòmanse konekte: Press and hold the 'Start/Stop' button until the logging indicator appears on the LCD. The device will begin recording data according to the configured settings.
- Sispann Anrejistreman: Press and hold the 'Start/Stop' button again until the logging indicator disappears. Data logging will cease.
4.2. Mòd Avyon
Airplane mode disables all wireless communication (4G) to comply with aviation regulations. Data logging continues internally.

Figure 4.1: Loget 260-TH illustrating Flight Mode activation methods.
- Aktivasyon manyèl: Press the 'Activate/Airplane Mode' button (Figure 2.1, item 3) to toggle airplane mode on or off.
- Aktivasyon Pwograme: Configure specific times for airplane mode activation via the iCold platform.
- Electronic Fence Activation: Set up a custom geographical area in the iCold platform. The device will automatically enter airplane mode upon entering this area and exit upon leaving.
4.3. Data Access and Alarms

Figure 4.2: Loget 260-TH data displayed on the Elitech iCold mobile application.
- Done an tan reyèl: View live temperature, humidity, light, shock, and location data on the Elitech iCold APP or web platfòm.
- Done Istorik: Access and analyze historical data, generate reports (PDF/CSV), and track routes through the iCold platform.
- Notifikasyon alam: Receive instant alerts via APP, SMS, or Email when configured parameters exceed set thresholds. The device also provides local visual and audible alarms.

Figure 4.3: Elitech iCold platform demonstrating PDF and CSV report export functionality.
5. Antretyen
5.1. Swen batri
- Recharge the device regularly, especially if it will be stored for an extended period.
- Avoid exposing the device to extreme temperatures during charging or storage, as this can degrade battery life.
5.2. Netwayaj
- Siye aparèy la ak yon mou, twal sèk.
- Pa sèvi ak pwodui netwayaj abrazif oswa solvan, paske sa yo ka domaje c la.asing or sensors.
5.3. Depo
- Sere aparèy la nan yon kote ki fre, sèk lwen limyè solèy la dirèk.
- Ensure the battery is partially charged (around 50%) before long-term storage.
NAN. Depanaj
6.1. Aparèy la pa limen
- Asire w aparèy la byen chaje. Konekte l nan yon sous kouran avèk kab USB Kalite-C a.
- Verify that the 'Start/Stop' button is pressed and held for the required duration.
6.2. No 4G Network Connection
- Check the signal strength indicator on the LCD. If weak, move to an area with better network coverage.
- Ensure airplane mode is not active.
- Contact Elitech support if the issue persists, as the built-in SIM card may require troubleshooting.
6.3. Data Not Uploading to iCold Platform
- Confirm the device has a stable 4G connection.
- Verify that the device is correctly added and configured in your iCold account.
- Check the upload interval settings in the iCold platform.
6.4. Lekti ki pa egzak
- Ensure the sensors are not obstructed or exposed to direct heat/cold sources that do not reflect the ambient environment.
- Allow the device to stabilize in a new environment for a few minutes before taking critical readings.
7. Espesifikasyon
| Paramèt | Valè |
|---|---|
| Nimewo Modèl | US-LogEt260-TH-10PACK |
| Ranje Tanperati (Entèn) | -30 ℃ a 60 ℃ (-22 ℉ a 140 ℉) |
| Ranje Imidite (Entèn) | 0% a 100% RH |
| Limyè Sensor Range | 0 a 52000 Lux |
| Ranje Capteur Chòk | 0g a 16g |
| Kote Tracking | LBS (Location-Based Service) |
| Done Kapasite Depo | 100,000 points (offline) |
| Koneksyon | 4G (Built-in SIM Card) |
| Voye Entèval | Configurable (1 minute to 24 hours) |
| Kalite batri | Lityòm Ion (enkli) |
| Entèfas | USB Kalite-C |
| Konfòmite | Do160 (Aviation Safety), FDA CFR 21 Part 11 |
8. Garanti ak sipò
For warranty information, technical support, or service inquiries, please contact Elitech Technology Inc. directly. Refer to the official Elitech websit la oswa enfòmasyon kontak yo te bay ak acha ou a pou jwenn dènye detay sipò yo.
Platfòm Elitech iCold: http://new.i-elitech.com