1. Enfòmasyon enpòtan sou sekirite
Please read all instructions carefully before installation and use. Failure to follow these instructions may result in electric shock, fire, or other hazards. Keep this manual for future reference.
- AVÈTISMAN: Risk pou chòk elektrik. Dekonekte kouran an nan disjonktè a oswa bwat fizib la anvan enstalasyon oswa antretyen.
- This product is designed for use in dry or damp kote yo ye. Pa sèvi ak kote dirèkteman ekspoze a dlo.
- Do not attempt to modify the tube or its components.
- Asire ke aparèy la byen chita.
- For Type B (ballast bypass) installation, wiring should be performed by a qualified electrician to ensure safety and compliance with local electrical codes.
- Do not look directly into the operating LED tube.
2. Pwodwi souview
The LumeGen 2ft LED Universal Tube is an energy-efficient lighting solution designed for versatile applications. It features a color temperature selector, allowing you to choose from five different white light options. Its shatterproof design ensures durability and safety.

Image: Two LumeGen 2ft LED Universal Tubes, highlighting the adjustable color temperature switch on each tube.
Karakteristik kle:
- Konpatibilite versatile: Supports both Type A (ballast compatible) and Type B (ballast bypass/direct wire) installations.
- Tanperati Koulè Customizable: Easily switch between 3000K (Warm White), 3500K (Neutral White), 4000K (Cool White), 5000K (Daylight), and 6500K (Bright Daylight).
- Shatterproof and Durable Design: Constructed with a PET-coated glass body and frosted lens for enhanced safety and longevity. UL Listed for quality assurance.
- Enèji-efikas: Consumes only 8W while delivering 1100 lumens, offering significant energy savings compared to traditional fluorescent tubes.
- Long Lifespan: Rated for 50,000 hours of operation, reducing the need for frequent replacements.
3. Espesifikasyon
| Spesifikasyon | Valè |
|---|---|
| Mak | LumeGen |
| Nimewo Modèl | LG-2T8-8-AB-5CCT |
| Kalite limyè | dirije |
| Wattage | 8 Watts |
| Klète | 1100 Lumen |
| Efikasite | 137.5 lumèn pou chak watt |
| Gwosè fòm anpoul | T8 |
| Baz anpoul | G13 |
| Tanperati Koulè | 3000K/3500K/4000K/5000K/6500K (Selectable) |
| Voltage | 100-120 vòlt |
| Frekans | 60 Hertz |
| Mwayèn lavi | 50,000 èdtan |
| Materyèl | Plastic (PET-coated glass) |
| Fini Kalite | Frosted |
| Itilizasyon Andedan kay la / Deyò | Andedan kay la |
| Dimansyon (Apeprè) | 49.37 inches (Length) |

Image: Product dimensions and color temperature selector detail.
4. Enstalasyon (Enstalasyon)
The LumeGen Universal Tube supports both Type A (ballast compatible) and Type B (ballast bypass/direct wire) installations. Always ensure power is OFF before beginning installation.

Image: The LED tube is compatible with both Type A (ballast compatible) and Type B (ballast bypass) systems.
4.1. Type A (Ballast Compatible) Installation
This method uses your existing electronic ballast. Ensure your ballast is compatible with LED T8 tubes. Refer to your ballast's specifications for compatibility.
- Etenn pouvwa: Locate the circuit breaker controlling the fixture and turn off the power. Verify power is off using a voltage tèsteur.
- Retire Tib Ansyen yo: Retire tib fliyoresan ki deja egziste yo nan aparèy la avèk prekosyon.
- Install LED Tubes: Insert the LumeGen LED tubes into the fixture's sockets. Ensure they are securely seated.
- Retabli pouvwa: Retounen kouran nan disjoncteurs a.
4.2. Type B (Ballast Bypass / Direct Wire) Installation
This method bypasses the existing ballast and wires the fixture directly to the main power supply. This installation should only be performed by a qualified electrician.
- Etenn pouvwa: Locate the circuit breaker controlling the fixture and turn off the power. Verify power is off using a voltage tèsteur.
- Remove Old Tubes and Ballast: Carefully remove the existing fluorescent tubes. Then, open the fixture and disconnect the wiring from the ballast. Remove the ballast from the fixture.
- Refè fil elektrik: Wire the fixture's lamp holders directly to the main power supply (100-120V AC, 60Hz). The LumeGen LED tube is single-ended powered, meaning power is supplied to one end of the tube. Connect the live (L) and neutral (N) wires to the pins on one end of the tube's socket. Consult the wiring diagram provided with the product packaging for specific instructions.
- Install LED Tubes: Insert the LumeGen LED tubes into the rewired fixture's sockets. Ensure they are securely seated.
- Retabli pouvwa: Retounen kouran nan disjoncteurs a.

Image: Visual representation of the LED tube installation process.
5. Operasyon
The LumeGen LED Universal Tube features a convenient switch to select your desired color temperature.
- Ensure Power is On: After installation, turn on the power to the fixture.
- Jwenn switch CCT a: On one end of the LED tube, you will find a small slider switch labeled with color temperature options (3000K, 3500K, 4000K, 5000K, 6500K).
- Chwazi Tanperati Koulè: Gently slide the switch to the desired Kelvin (K) setting. The light output will change immediately to reflect your selection.
- Ajiste jan sa nesesè: You can change the color temperature at any time while the tube is powered on.
6. Antretyen
The LumeGen LED Universal Tube requires minimal maintenance.
- Netwayaj: Asire w ou koupe kouran an anvan ou netwaye. Sèvi ak yon twal mou, sèk oswa yon ti kras mouye.amp cloth to wipe the surface of the tube. Do not use harsh chemicals, abrasive cleaners, or solvents, as these can damage the tube's finish or coating.
- Enspeksyon: Periodically inspect the tubes and fixture for any signs of damage or loose connections. If any issues are found, disconnect power and address them promptly.
- Depo: If storing the tubes, keep them in their original packaging in a cool, dry place away from direct sunlight and extreme temperatures.
NAN. Depanaj
If you encounter issues with your LumeGen LED Universal Tube, refer to the following common problems and solutions:
| Pwoblèm | Kòz posib | Solisyon |
|---|---|---|
| Tib la pa limen. | Pa gen pouvwa nan aparèy la. Improper installation (loose connection). Incompatible ballast (for Type A). Faulty tube. | Tcheke disjonktè a ak switch miray la. Ensure tubes are securely seated in sockets. For Type B, verify wiring. If Type A, confirm ballast compatibility or consider Type B installation. Test with another known working tube if available. |
| Tube flickers. | Incompatible ballast (for Type A). Koneksyon ki lach. Voltage fluctuations. | If Type A, ensure ballast is compatible. Some older ballasts may cause flickering. Consider Type B installation. Tcheke koneksyon. Konsilte yon elektrisyen si vòltagYo sispèk pwoblèm e yo. |
| Tanperati koulè ki pa kòrèk. | Switch CCT a pa byen regle. | Adjust the CCT selector switch on the tube to the desired setting. |
| Redwi klète. | Dust or dirt on tube surface. End of tube lifespan. | Clean the tube surface with a soft, dry cloth. If tube is near end of its rated lifespan, replacement may be necessary. |
8. Garanti ak sipò
LumeGen products are manufactured to high-quality standards. This product comes with a limited warranty against defects in materials and workmanship. For specific warranty details, please refer to the product packaging or contact LumeGen customer support.
If you require technical assistance, have questions about installation, or need to report a defect, please contact LumeGen customer support through the retailer where the product was purchased or visit the official LumeGen websit pou enfòmasyon kontak.
LumeGen Store: Visit the LumeGen Store on Amazon