LumeGen LG-2T8-8-AB-5CCT

LumeGen 2-Pack 2ft LED Universal Tube Instruction Manual

Model: LG-2T8-8-AB-5CCT

1. Enfòmasyon enpòtan sou sekirite

Please read all instructions carefully before installation and use. Failure to follow these instructions may result in electric shock, fire, or other hazards. Keep this manual for future reference.

  • AVÈTISMAN: Risk pou chòk elektrik. Dekonekte kouran an nan disjonktè a oswa bwat fizib la anvan enstalasyon oswa antretyen.
  • This product is designed for use in dry or damp kote yo ye. Pa sèvi ak kote dirèkteman ekspoze a dlo.
  • Do not attempt to modify the tube or its components.
  • Asire ke aparèy la byen chita.
  • For Type B (ballast bypass) installation, wiring should be performed by a qualified electrician to ensure safety and compliance with local electrical codes.
  • Do not look directly into the operating LED tube.

2. Pwodwi souview

The LumeGen 2ft LED Universal Tube is an energy-efficient lighting solution designed for versatile applications. It features a color temperature selector, allowing you to choose from five different white light options. Its shatterproof design ensures durability and safety.

Two LumeGen 2ft LED Universal Tubes showing the color temperature selector switch.

Image: Two LumeGen 2ft LED Universal Tubes, highlighting the adjustable color temperature switch on each tube.

Karakteristik kle:

  • Konpatibilite versatile: Supports both Type A (ballast compatible) and Type B (ballast bypass/direct wire) installations.
  • Tanperati Koulè Customizable: Easily switch between 3000K (Warm White), 3500K (Neutral White), 4000K (Cool White), 5000K (Daylight), and 6500K (Bright Daylight).
  • Shatterproof and Durable Design: Constructed with a PET-coated glass body and frosted lens for enhanced safety and longevity. UL Listed for quality assurance.
  • Enèji-efikas: Consumes only 8W while delivering 1100 lumens, offering significant energy savings compared to traditional fluorescent tubes.
  • Long Lifespan: Rated for 50,000 hours of operation, reducing the need for frequent replacements.

3. Espesifikasyon

SpesifikasyonValè
MakLumeGen
Nimewo ModèlLG-2T8-8-AB-5CCT
Kalite limyèdirije
Wattage8 Watts
Klète1100 Lumen
Efikasite137.5 lumèn pou chak watt
Gwosè fòm anpoulT8
Baz anpoulG13
Tanperati Koulè3000K/3500K/4000K/5000K/6500K (Selectable)
Voltage100-120 vòlt
Frekans60 Hertz
Mwayèn lavi50,000 èdtan
MateryèlPlastic (PET-coated glass)
Fini KaliteFrosted
Itilizasyon Andedan kay la / DeyòAndedan kay la
Dimansyon (Apeprè)49.37 inches (Length)
Diagram showing the dimensions of the LumeGen LED tube and its color temperature selector.

Image: Product dimensions and color temperature selector detail.

4. Enstalasyon (Enstalasyon)

The LumeGen Universal Tube supports both Type A (ballast compatible) and Type B (ballast bypass/direct wire) installations. Always ensure power is OFF before beginning installation.

Graphic indicating the LED tube supports both Type A and Type B installations.

Image: The LED tube is compatible with both Type A (ballast compatible) and Type B (ballast bypass) systems.

4.1. Type A (Ballast Compatible) Installation

This method uses your existing electronic ballast. Ensure your ballast is compatible with LED T8 tubes. Refer to your ballast's specifications for compatibility.

  1. Etenn pouvwa: Locate the circuit breaker controlling the fixture and turn off the power. Verify power is off using a voltage tèsteur.
  2. Retire Tib Ansyen yo: Retire tib fliyoresan ki deja egziste yo nan aparèy la avèk prekosyon.
  3. Install LED Tubes: Insert the LumeGen LED tubes into the fixture's sockets. Ensure they are securely seated.
  4. Retabli pouvwa: Retounen kouran nan disjoncteurs a.

4.2. Type B (Ballast Bypass / Direct Wire) Installation

This method bypasses the existing ballast and wires the fixture directly to the main power supply. This installation should only be performed by a qualified electrician.

  1. Etenn pouvwa: Locate the circuit breaker controlling the fixture and turn off the power. Verify power is off using a voltage tèsteur.
  2. Remove Old Tubes and Ballast: Carefully remove the existing fluorescent tubes. Then, open the fixture and disconnect the wiring from the ballast. Remove the ballast from the fixture.
  3. Refè fil elektrik: Wire the fixture's lamp holders directly to the main power supply (100-120V AC, 60Hz). The LumeGen LED tube is single-ended powered, meaning power is supplied to one end of the tube. Connect the live (L) and neutral (N) wires to the pins on one end of the tube's socket. Consult the wiring diagram provided with the product packaging for specific instructions.
  4. Install LED Tubes: Insert the LumeGen LED tubes into the rewired fixture's sockets. Ensure they are securely seated.
  5. Retabli pouvwa: Retounen kouran nan disjoncteurs a.
Collage of images showing a person installing an LED tube into a light fixture.

Image: Visual representation of the LED tube installation process.

5. Operasyon

The LumeGen LED Universal Tube features a convenient switch to select your desired color temperature.

  1. Ensure Power is On: After installation, turn on the power to the fixture.
  2. Jwenn switch CCT a: On one end of the LED tube, you will find a small slider switch labeled with color temperature options (3000K, 3500K, 4000K, 5000K, 6500K).
  3. Chwazi Tanperati Koulè: Gently slide the switch to the desired Kelvin (K) setting. The light output will change immediately to reflect your selection.
  4. Ajiste jan sa nesesè: You can change the color temperature at any time while the tube is powered on.

6. Antretyen

The LumeGen LED Universal Tube requires minimal maintenance.

  • Netwayaj: Asire w ou koupe kouran an anvan ou netwaye. Sèvi ak yon twal mou, sèk oswa yon ti kras mouye.amp cloth to wipe the surface of the tube. Do not use harsh chemicals, abrasive cleaners, or solvents, as these can damage the tube's finish or coating.
  • Enspeksyon: Periodically inspect the tubes and fixture for any signs of damage or loose connections. If any issues are found, disconnect power and address them promptly.
  • Depo: If storing the tubes, keep them in their original packaging in a cool, dry place away from direct sunlight and extreme temperatures.

NAN. Depanaj

If you encounter issues with your LumeGen LED Universal Tube, refer to the following common problems and solutions:

PwoblèmKòz posibSolisyon
Tib la pa limen.Pa gen pouvwa nan aparèy la.
Improper installation (loose connection).
Incompatible ballast (for Type A).
Faulty tube.
Tcheke disjonktè a ak switch miray la.
Ensure tubes are securely seated in sockets. For Type B, verify wiring.
If Type A, confirm ballast compatibility or consider Type B installation.
Test with another known working tube if available.
Tube flickers.Incompatible ballast (for Type A).
Koneksyon ki lach.
Voltage fluctuations.
If Type A, ensure ballast is compatible. Some older ballasts may cause flickering. Consider Type B installation.
Tcheke koneksyon.
Konsilte yon elektrisyen si vòltagYo sispèk pwoblèm e yo.
Tanperati koulè ki pa kòrèk.Switch CCT a pa byen regle.Adjust the CCT selector switch on the tube to the desired setting.
Redwi klète.Dust or dirt on tube surface.
End of tube lifespan.
Clean the tube surface with a soft, dry cloth.
If tube is near end of its rated lifespan, replacement may be necessary.

8. Garanti ak sipò

LumeGen products are manufactured to high-quality standards. This product comes with a limited warranty against defects in materials and workmanship. For specific warranty details, please refer to the product packaging or contact LumeGen customer support.

If you require technical assistance, have questions about installation, or need to report a defect, please contact LumeGen customer support through the retailer where the product was purchased or visit the official LumeGen websit pou enfòmasyon kontak.

LumeGen Store: Visit the LumeGen Store on Amazon

Dokiman ki gen rapò - LG-2T8-8-AB-5CCT

Preview LumeGen LED Panel Instruction Manual and Specifications
This document provides comprehensive instructions for installing and using LumeGen LED Panel lights, including safety guidelines, electrical specifications, installation methods for recessed and surface mounting, emergency battery backup wiring, troubleshooting tips, and a 5-year limited warranty. It covers models LEDLFPN1000051817-3500K, LEDLFPN1000051817-4000K, and LEDLFPN1000051817-5000K.
Preview LumeGen LED Square Canopy Light J-CP100/130/150W-3CCT - Specifications
Detailed specifications for the LumeGen J-CP100/130/150W-3CCT LED Square Canopy Light. Features include wattage and color tunability, 50,000-hour lifespan, ETL and DLC Premium certifications, and suitability for outdoor applications like gas stations and parking garages.
Preview LumeGen Adjustable LED Backlit Flat Panel - 2x4, 2x2, 1x4 Specifications
Comprehensive specifications for the LumeGen Adjustable LED Backlit Flat Panel series, featuring wattage and color tunability, energy savings, and various sizes (2x4, 2x2, 1x4). Includes electrical data, dimensions, mounting options, emergency capabilities, and photometrics.
Preview Limyè plat LumeGen reglabl ak LED ki gen limyè dèyè (2x4, 2x2, 1x4) - Espesifikasyon ak Karakteristik
Espesifikasyon detaye pou limyè plat LumeGen yo ki gen ekleraj LED reglabl ak koulè reglabl. Karakteristik yo enkli plizyè wat.tagOpsyon tanperati koulè ak e, dire lavi 50,000 èdtan, lis ETL, sètifikasyon DLC Premium V5.1, ak kapasite backup ijans. Disponib nan gwosè 2x4, 2x2, ak 1x4.
Preview Limyè plat LumeGen estatik ak limyè LED - Pwodwi finiview
Espesifikasyon ak karakteristik detaye pou limyè LumeGen Static LED Backlit Flat Panel, disponib nan gwosè 2x4, 2x2, ak 1x4. Gen ladan karakteristik pwodwi, espesifikasyon elektrik, desen dimansyon, fotometrik, detay anbalaj, ak enfòmasyon sou akseswa.
Preview Limyè Solè LumeGen pou Poto Drapo ki gen Gwo Pwodiksyon FLG-ST-SF889 | 1100 Lumèn, IP65
Eksplore Limyè Solè pou Poto Drapo LumeGen FLG-ST-SF889 ki gen gwo puisans. Li gen 1100 lumèn, ekleraj 360°, 12 èdtan fonksyon, klasman IP65, panno solè monokristalin, ak yon detèktè fotoselil. Ideyal pou poto drapo,...amping, ak teras.