1. Entwodiksyon
This manual provides comprehensive instructions for the installation, operation, and maintenance of your ACiQ 3 Tons 14.4 SEER2 Central Inverter Heat Pump System. Please read this manual thoroughly before installation and operation to ensure proper function and safety.
The ACiQ Inverter Heat Pump System is designed for high efficiency heating and cooling, adapting its output to meet changing weather conditions. It includes an inverter heat pump, a multi-positional cased evaporator coil, and a complete installation kit.
2. Enfòmasyon sou Sekirite
Always adhere to local and national electrical and building codes. Installation and servicing should only be performed by qualified personnel.
- Sekirite elektrik: Disconnect all power before servicing. Ensure proper grounding.
- Manyen frijidè: Only certified technicians should handle refrigerants.
- Ekipman Pwoteksyon Pèsonèl (PPE): Wear appropriate PPE, including gloves and eye protection, during installation and maintenance.
- Pwa: Components can be heavy. Use proper lifting techniques or seek assistance.
3. Konpozan sistèm
The ACiQ 3 Tons 14.4 SEER2 Central Inverter Heat Pump System includes the following main components:
- Inverter Heat Pump: Converts AC power to DC, adjusting compressor speed and BTU output.
- Bobin evaporatè: Cased multi-positional coil with factory-integrated TXV kit.
- Enstalasyon Twous: Includes Cielo Smart Thermostat, 50' insulated line set, 1/2" x 6' 10-gauge electrical whip, 60A non-fused disconnect switch, ICM Controls Surge Protector, CPS Charging Adapter, Wall Sleeve, and Wall Mount Bracket.

Figi 3.1: Plis paseview of the ACiQ Heat Pump System components, including the outdoor unit, indoor coil, thermostat, and various installation accessories.

Figi 3.2: Detaye view of the complete installation kit, showing the line set, electrical whip, disconnect switch, surge protector, and smart thermostat.
4. Espesifikasyon
4.1. Heat Pump Condenser Specifications
- Summer Cooling Control: 36,000 BTU/H cooling precision
- Winter Warmth Control: 36,000 to 35,000 BTU/H heating power
- Efikasite enèji: Up to 14.4 SEER (9.30 EER2) performance
- Summer Proof Cooling: 5°F to 122°F outdoor temp operation
- Winter Proof Heating: 5°F to 75°F outdoor temp operation
- Bobin kondansateur: Gold fin for durability
- Operasyon: Quietest operation at maximum workloads

Figure 4.1: Visual representation of the heat pump condenser and its key specifications.
4.2. Evaporator Coil Specifications
- Koule lè: 1058.82 CFM
- Presyon: 0.28 In. wg.
- Dezumidifikasyon: 4.64
- Dimansyon (W x P x H): 21.52 x 20.98 x 23.58 pous (547 x 533 x 599 mm)
- Packing (W x D x H): 23.47 x 26.18 x 25.39 pous (596 x 665 x 645 mm)
- Net/Pwa Brit: 62.19 / 71.00 lbs (28.20 / 32.20 kg)
Note: The coil is specifically designed for use with gas furnaces or modular blowers and cannot be substituted for a one-piece air handler.

Figi 4.2: Detaye view of the evaporator coil with its dimensions and performance metrics.
4.3. Dimansyon jeneral

Figure 4.3: Overall dimensions of the outdoor heat pump unit and the evaporator coil.
5. Enstalasyon ak Enstalasyon
Installation of this system requires specialized knowledge and tools. It is strongly recommended that installation be performed by a certified HVAC technician.
5.1. Lis Verifikasyon Pre-Enstalasyon
- Verifye tout eleman yo prezan epi yo pa domaje.
- Ensure proper electrical supply is available (voltage, ampepòk).
- Confirm adequate space for both indoor and outdoor units, allowing for proper airflow and service access.
- Review local building codes and obtain necessary permits.
5.2. Outdoor Unit Placement
Place the outdoor unit on a level, stable surface, away from obstructions that could impede airflow. Ensure sufficient clearance around the unit for maintenance and proper operation.

Figi 5.1: Egzample of an outdoor unit installed on a wall mount bracket, demonstrating proper clearance.
5.3. Evaporator Coil Installation
The evaporator coil is multi-positional. Install it in conjunction with a gas furnace or modular blower. Ensure proper drainage for condensate.
5.4. Line Set and Electrical Connections
- Connect the insulated line set between the outdoor unit and the evaporator coil. Ensure proper flaring and torque.
- Install the electrical whip and disconnect switch according to electrical codes.
- Connect the ICM Controls Surge Protector for electrical protection.
5.5. Enstalasyon Thermostat
Install the Cielo Smart Thermostat according to its dedicated instructions. This thermostat allows for app control and integration with smart home systems like Alexa, Google Home, Siri, SmartThings, and IFTTT.

Figure 5.2: Diagram illustrating the features and connectivity options of the Cielo Smart Thermostat.
6. Operasyon Enstriksyon
Once installed, the system can be operated via the Cielo Smart Thermostat or its associated mobile application.
6.1. Operasyon debaz
- Pouvwa sou: Ensure the disconnect switch is in the ON position.
- Seleksyon mòd: Use the thermostat to select operating modes: Cooling, Heating, Fan Only, or Auto.
- Anviwònman Tanperati: Ajiste tanperati a vle lè l sèvi avèk kontwòl tèmostat yo.
6.2. Smart Thermostat Features
The Cielo Smart Thermostat offers advanced features for enhanced comfort and energy savings:
- Orè: Program daily or weekly schedules to optimize energy use.
- Aksè Remote: Control your system from anywhere using the mobile app.
- Kontwòl vwa: Integrate with Amazon Alexa, Google Assistant, or Apple Siri for hands-free control.
- Entegrasyon kay entelijan: Connect with SmartThings and IFTTT for advanced automation.
7. Antretyen
Regular maintenance is crucial for optimal performance and longevity of your ACiQ system. It is recommended to have a qualified technician perform annual inspections.
7.1. Antretyen itilizatè
- Ranplasman filtè lè: Check and replace air filters monthly or as needed, especially during peak usage seasons.
- Netwayaj Inite Eksteryè a: Keep the area around the outdoor unit clear of debris, leaves, and obstructions. Gently clean the exterior coils with a soft brush and water if necessary.
- Drenaj kondansasyon: Periodically check the condensate drain line for clogs and ensure proper drainage.
7.2. Professional Maintenance
An annual professional tune-up typically includes:
- Refrigerant level check and adjustment.
- Coil cleaning (indoor and outdoor).
- Enspeksyon ak sere boulon koneksyon elektrik.
- Blower motor and fan inspection.
- Thermostat calibration.
NAN. Depanaj
This section provides solutions to common issues. For problems not listed here, or if solutions do not resolve the issue, contact a qualified HVAC technician.
| Pwoblèm | Kòz posib | Solisyon |
|---|---|---|
| Sistèm pa limen | No power, tripped breaker, thermostat issue | Check disconnect switch, reset breaker, ensure thermostat is powered and set correctly. |
| Chofaj/refwadisman ensifizan | Dirty air filter, blocked outdoor unit, low refrigerant, incorrect thermostat setting | Replace air filter, clear obstructions from outdoor unit, check thermostat settings. Contact technician for refrigerant issues. |
| Bwi etranj | Loose parts, fan obstruction, compressor issue | Inspect for loose panels or debris. If noise persists, contact a technician. |
| Dlo koule nan inite andedan kay la | Clogged condensate drain line, frozen evaporator coil | Clear drain line. If coil is frozen, turn off system and allow to thaw, then check airflow. Contact technician if issue persists. |
9. Enfòmasyon sou Garanti
The ACiQ 3 Tons 14.4 SEER2 Central Inverter Heat Pump System comes with a comprehensive warranty:
- Pati: 7-year warranty on parts.
- COMPRESSOR: 12-ane garanti sou COMPRESSOR la.
Kondisyon garanti: The warranty is valid when the unit is installed by a qualified technician and registered online with the manufacturer at no additional charge. Please retain your proof of purchase and installation records.
10. Sipò ak Kontak
For technical support, warranty claims, or service inquiries, please contact ACiQ customer service or visit our official websit.
ACiQ Official Websit: Visit the ACiQ Store on Amazon
Please have your model number (B0D522DYZ7) and purchase date ready when contacting support.