Extech ET11

Manyèl Itilizatè Tèsè Priz Extech ET11 GFCI

Modèl: ET11

1. Pwodwi souview

The Extech ET11 is a GFCI Receptacle Tester designed for Type B electrical outlets. It is used to test for correct wiring of 3-wire receptacles in 110-125 V AC, 50/60 Hz circuits and to confirm the operation of Ground Fault Circuit Interrupter (GFCI) protective devices.

Extech ET11 GFCI Receptacle Tester front view

Imaj: Devan view of the Extech ET11 GFCI Receptacle Tester, showing the indicator lights and test button.

Extech ET11 GFCI Receptacle Tester with text overlay

Image: The Extech ET11 GFCI Receptacle Tester with text indicating its purpose for Type B electrical outlets and its ability to detect wiring faults.

2. Karakteristik

  • Tests for correct wiring of 3-wire receptacles in 110-125 V AC, 50/60 Hz circuits.
  • Detects 5 common wiring faults: Correct, Open Ground, Open Neutral, Open Hot, Hot/Ground Reverse, and Hot/Neutral Reverse.
  • Works on GFCI outlets and confirms operation of the ground fault protective device.
  • Conveniently verifies both ‘ground bottom’ and ‘ground top’ style sockets with a test code light legend on both sides of the device.
  • Ergonomic pull bar design for easy removal from outlets.
Extech ET11 showing ergonomic pull bar

Image: Close-up of the Extech ET11 highlighting its ergonomic pull bar for easy removal from outlets.

3. Operasyon Enstriksyon

3.1. Testing Standard Receptacles

  1. Ensure the receptacle is powered and safe to approach.
  2. Insert the Extech ET11 tester firmly into the 3-wire receptacle.
  3. Observe the indicator lights on the tester. Refer to the wiring fault legend printed on the tester for interpretation.
  4. The combination of illuminated lights will indicate the wiring status (e.g., Correct, Open Ground, Open Neutral, Open Hot, Hot/Ground Reverse, Hot/Neutral Reverse).
  5. Remove the tester from the receptacle once the reading is taken.
Extech ET11 in use on a GFCI outlet

Image: The Extech ET11 GFCI Receptacle Tester plugged into a GFCI outlet, demonstrating its use for testing wiring.

Electrician using Extech ET11

Image: A person wearing work gloves and safety vest using the Extech ET11 to test an electrical outlet.

3.2. Testing GFCI Receptacles

  1. First, perform a standard wiring test as described above to ensure the receptacle is correctly wired.
  2. If the wiring is correct, press the GFCI test button on the Extech ET11 tester.
  3. A working GFCI outlet should trip, cutting power to the receptacle. The GFCI reset button on the outlet should pop out.
  4. If the GFCI does not trip, it indicates a fault with the GFCI mechanism or wiring.
  5. To restore power, press the reset button on the GFCI outlet.

3.3. Interpreting Indicator Lights

The Extech ET11 features a clear light legend on both the front and back to help interpret wiring conditions. The legend uses combinations of three indicator lights (typically amber/orange) to show the status.

Extech ET11 front and back with wiring legend

Imaj: Devan ak dèyè views of the Extech ET11 GFCI Receptacle Tester, clearly showing the wiring fault legend with light patterns for 'Open Ground', 'Open Neutral', 'Open Hot', 'Hot/Ground Reverse', 'Hot/Neutral Reverse', and 'Correct' wiring.

Wiring Fault Legend
KondisyonLight 1 (Left)Light 2 (Middle)Light 3 (Right)
KòrèkOffOnOn
Open GroundOffOnOff
Louvri netOnOffOn
Louvri choOffOffOff
Ranvèse cho/tèOnOnOff
Hot/Neutral ReverseOnOffOff

4. Antretyen ak Swen

  • Keep the tester clean and free from dust and debris. Wipe with a dry, soft cloth.
  • Do not expose the tester to extreme temperatures or moisture.
  • Store the tester in a safe place when not in use to prevent damage to the prongs or casing.
  • The Extech ET11 does not require batteries or user-serviceable parts. Do not attempt to open or repair the device.

NAN. Depanaj

If the Extech ET11 tester does not function as expected, consider the following:

  • No lights illuminate: Ensure the receptacle is live and properly powered. Test with a known working outlet.
  • Inconsistent readings: Ensure the tester is fully inserted into the receptacle. Check for loose connections in the outlet itself.
  • GFCI does not trip: If the GFCI test button is pressed and the GFCI outlet does not trip, this indicates a fault with the GFCI mechanism or the wiring to the GFCI. Consult a qualified electrician.
  • Domaj fizik: If the tester appears physically damaged, discontinue use immediately and replace the unit.

6. Espesifikasyon

Extech ET11 product dimensions and weight

Image: The Extech ET11 GFCI Receptacle Tester shown alongside its product size (4.26 x 1.78 x 1.1 inches) and weight (1.6 oz), and a note that it includes the tester and user manual.

SpesifikasyonDetay
Nimewo ModèlET11
ManifaktiExtech
Nimewo PatiET11
Pwa atik2.29 ons
Dimansyon pwodwi0.63 x 0.63 x 0.12 pous
Peyi orijinLachin
Kantite pake atik1
Presizyon Mezi+/-0.5%
Konpozan ki enkliTèstè elektrik
Batri obligatwa?Non
ASINB0D431PZXS
Dat Premye Disponib13 me 2024

7. Garanti ak sipò

Specific warranty information for the Extech ET11 GFCI Receptacle Tester is typically provided with the product packaging or can be found on the official Extech website. For detailed warranty terms, service, or technical support, please refer to the contact information provided by Extech.

You can visit the official Extech websit pou plis asistans: www.extech.com

Dokiman ki gen rapò - ET11

Preview Manyèl Itilizatè Tès Kontinuite Extech ET40 pou Travay Lou
Manyèl itilizatè pou aparèy pou teste kontinite Extech ET40 Heavy Duty la. Aprann kijan pou teste kontinite konpozan, fizib, switch, relè, fil elektrik ak sikwi elektrik ki pa gen kouran yon fason ki an sekirite epi efikas.
Preview EXTECH 40180 Tone jeneratè ak AmpManyèl itilizatè sonde pi vi
User manual for the EXTECH 40180 Tone Generator and Amplifier Probe. Learn about its features, operation, specifications, and troubleshooting for cable tracing and phone line testing.
Preview Extech ET20 Endikatè Doub Volimtage Manyèl Itilizatè Detektè
Manyèl itilizatè pou Extech ET20 Doub Endikatè Vol latagDetektè e, yon vòltaj AC/DC 2-fasontagAparèy tès e (100-250V). Bay enfòmasyon sou operasyon, garanti ak sèvis.
Preview Extech CT20 Continuity Tester Pro User Manual - Features, Specifications, and Operation
Comprehensive user manual for the Extech CT20 Continuity Tester Pro. Learn about its features, specifications, safety precautions, local continuity testing, and advanced remote continuity and wire identification capabilities.
Preview Gid Itilizatè Kalibratè Kouran Extech PRC10 la
Gid konplè pou itilizatè a pou kalibratè kouran Extech PRC10 la. Aprann plis sou karakteristik li yo, mòd operasyon li yo (Mezi, Sous), direktiv sekirite, espesifikasyon, ak sèvis kalibrasyon nan men Extech Instruments, yon konpayi FLIR Systems.
Preview Manyèl Itilizatè Minutè Dijital Extech 375475
Manyèl itilizatè pou revèy dijital Extech 375475 la, ki detaye konfigirasyon, pwogramasyon ak operasyon pou kontwole aparèy yo.