Entwodiksyon
Thank you for choosing the OLMO 8,000 BTU 115V Through-the-Wall Air Conditioner and Heat System. This unit is designed to provide efficient heating and cooling for residential, commercial, or hotel use. It features a built-in wireless smart kit for convenient control via smartphone, an included remote control, and comes with a wall sleeve for installation.
This manual provides essential information for the safe and effective setup, operation, and maintenance of your OLMO unit. Please read it thoroughly before installation and use.
Figure 1: OLMO Through-the-Wall Air Conditioner and included accessories.
Enstalasyon ak Enstalasyon
The OLMO Through-the-Wall Air Conditioner is designed for packaged installation. A wall sleeve is included with your unit to facilitate proper mounting.
Lis Verifikasyon Pre-Enstalasyon:
- Verify power supply: This unit requires a 115V, 1-phase, 60Hz power supply. Ensure you have the correct receptacle.
- Check dimensions: The product dimensions are approximately 20.28 x 24.21 x 14.53 inches. Ensure your wall opening is appropriately sized for the unit and wall sleeve.
- Confirm refrigerant: The unit is pre-charged with R-32 refrigerant.
Wall Sleeve Installation:
The included wall sleeve (Model: OW-TTWSLV) is crucial for secure and proper installation. Follow the detailed instructions provided in the separate installation guide for precise measurements and mounting procedures. Proper sealing and insulation around the sleeve are essential for optimal performance and energy efficiency.

Figure 2: Included Wall Sleeve (OW-TTWSLV).
Plasman inite:
Ensure the unit is installed in a location that allows for proper airflow around the intake and exhaust vents. Avoid placing objects directly in front of or on top of the unit that could obstruct air circulation.
Enstriksyon Operasyon
Your OLMO Through-the-Wall unit offers multiple control options for your convenience:
- Digital Push Button Control Panel: Located on the unit with an LED display for direct control.
- Included Remote Controller: Provides full functionality from a distance.
- Built-In Wireless Smart Kit: Allows control via a compatible smartphone application.
Fonksyon kontwòl remote:
The remote control allows you to adjust temperature, change modes (Cool, Heat, Fan, Dry, Auto), set fan speeds, and activate special features like Sleep Mode and Timer.

Figure 3: Remote Control for OLMO AC Unit.
Smart Connect (Wi-Fi) Operation:
The built-in Smart Connect feature enables you to control your unit remotely using a smartphone app. Download the official OLMO app from your device's app store and follow the in-app instructions to pair your unit. This allows for convenient control from anywhere with an internet connection.

Figure 4: Smartphone App for Smart Control.
Karakteristik kle:
- Mòd dòmi: Adjusts temperature automatically for comfortable sleep and energy saving.
- Rekòmanse Auto: Aparèy la ap rekòmanse otomatikman ak ansyen paramèt yo apre yon pann kouran.tage.
- Plizyè vitès fanatik: Choose from various fan speeds for customized airflow.
- Revèy: Pwograme aparèy la pou l limen oswa etenn nan moman espesifik.
- Self-Evaporative System: Helps manage condensate, reducing the need for manual draining in most conditions.
- Dirije ekspozisyon: Provides clear indication of settings and operating status.
- Fresh Air Input: Allows for introduction of fresh outdoor air.
Videyo: Finiview of OLMO Through-the-Wall Air Conditioner features and capabilities. This video demonstrates the unit's design and highlights its smart connectivity and remote control options.
Antretyen
Regular maintenance ensures optimal performance and longevity of your OLMO air conditioner. Always disconnect power to the unit before performing any maintenance.
Netwayaj filtè lè:
The air filter should be cleaned every two weeks, or more frequently depending on usage and air quality. A dirty filter can reduce cooling/heating efficiency and airflow.
- Louvri panèl devan aparèy la.
- Retire filtè lè a (yo) avèk prekosyon.
- Lave filtè a avèk dlo tyèd savon. Rense l byen.
- Allow the filter to air dry completely before reinserting. Do not expose to direct sunlight or heat.
Netwayaj jeneral:
Siye eksteryè inite a ak yon mou, damp cloth. Do not use harsh chemicals, abrasives, or solvents, as these can damage the surface. Ensure the drainage area is clear of debris.
Depanaj
If you experience issues with your OLMO air conditioner, refer to the following common troubleshooting steps. For problems not listed here, or if issues persist, please contact OLMO customer support.
| Pwoblèm | Kòz posib | Solisyon |
|---|---|---|
| Inite pa limen | No power supply; Circuit breaker tripped; Unit unplugged. | Check power cord connection; Reset circuit breaker; Ensure unit is plugged into a functional 115V outlet. |
| Refwadisman/chofaj ensifizan | Dirty air filter; Obstructed airflow; Temperature setting too high/low; Room size exceeds capacity. | Clean air filter; Remove obstructions from vents; Adjust temperature setting; Ensure unit capacity matches room size. |
| Inite a fè bwi | Pyès ki lach; Inite a pa nivo; Vantilatè a bloke. | Check for loose components; Ensure unit is level; Inspect fan for obstructions. |
| Remote kontwòl pa travay | Pil mouri; Gen obstak ant kontwòl remote la ak aparèy la. | Ranplase pil yo; Asire w ke liy vizyon an klè ak reseptè inite a. |
Espesifikasyon
Detailed technical specifications for the OLMO 8,000 BTU 115V Through-the-Wall Air Conditioner and Heat System (Model: OW-P08HS115WF/ OW-TTWSLV).
| Spesifikasyon | Valè |
|---|---|
| Non mak | ELM |
| Enfòmasyon sou modèl | OW-P08HS115WF/ OW-TTWSLV |
| Pwa atik | 80 liv |
| Dimansyon pwodwi (D x W x H) | 20.28 x 24.21 x 14.53 pous |
| Peyi orijin | Lachin |
| Efikasite | Bon |
| Kapasite | 0.66 tòn |
| Nivo bri | 52 dB |
| Kalite enstalasyon | Packaged, Through-the-Wall |
| Karakteristik espesyal | Kontwole adistans, aktive WiFi |
| Eleman chofaj | 1 |
| Koulè | Blan |
| Voltage | 115 Volts |
| Konpozan ki enkli | Through the Wall Air Conditioner, Wall Sleeve and Remote Control |
| Pouvwa refwadisman | 8000 Inite tèmik Britanik yo |
| Refrijeran | R-32 |

Figure 5: Comprehensive Technical Specifications Table.
Garanti ak sipò
For technical assistance, warranty inquiries, or further support, please contact OLMO customer service. Refer to your product packaging or the official OLMO websit la pou jwenn enfòmasyon kontak ki pi resan yo.
You can also visit the official OLMO store for more product information and resources: OLMO Store on Amazon.