Elitech LMG-10W, LMC-100A+, ILD-200

Elitech 2-Way Valve Manifold Gauge LMG-10W, Refrigerant Scale LMC-100A+, Infrared Refrigeration Leak Detector ILD-200 User Manual

Model: LMG-10W, LMC-100A+, ILD-200

Entwodiksyon

This user manual provides comprehensive instructions for the Elitech HVAC/R service kit, which includes the Elitech LMG-10W 2-Way Valve Manifold Gauge, the Elitech LMC-100A+ Refrigerant Scale, and the Elitech ILD-200 Infrared Refrigeration Leak Detector. This kit is designed for professional HVAC/R technicians to perform accurate refrigerant charging, recovery, and leak detection tasks.

Elitech HVAC/R Service Kit including manifold gauge, refrigerant scale, and leak detector

Figure 1: Elitech HVAC/R Service Kit components.

Pwodwi konpozan

Elitech LMG-10W 2-Way Valve Manifold Gauge

The LMG-10W is a digital manifold gauge designed for precise measurement of pressure, temperature, and vacuum in HVAC/R systems. It features a clear display and robust construction for reliable performance.

  • Kontwòl APP: Seamless integration with the Elitech Tools App for remote monitoring and control.
  • Remote Firmware Upgrade: Allows for convenient updates to the device's software.
  • Accurate Tightness Test Results: Provides precise data for system integrity checks.
  • Instant Report Export: Generate and export reports for documentation.
  • Automatic Calculation: Calculates subcooling and superheat automatically.
  • Long lavi batri: Up to 200+ hours of operation.
  • Ranje mezi: -14.5 to 800 psi.
  • Presizyon: ±0.5% FS.
  • Inite: psi, kg/cm3, kPa, MPa, bar.
  • Tanperati travay: 14~122°F / -10~50°C.
Elitech LMG-10W digital manifold gauge with hoses and temperature clamps

Figure 2: Elitech LMG-10W Digital Manifold Gauge with included accessories.

Elitech LMG-10W digital manifold gauge display showing various data points and features like APP control and remote firmware upgrade

Figure 3: Key features and display of the Elitech LMG-10W.

Elitech LMG-10W digital manifold gauge dimensions and specifications

Figure 4: Dimensions and detailed specifications of the Elitech LMG-10W.

Elitech LMC-100A+ Refrigerant Scale

The LMC-100A+ is a high-capacity electronic refrigerant charging and recovery scale, essential for accurate refrigerant handling.

  • Kapasite: Up to 220lbs (100kg).
  • Presizyon: ±0.05% readings +10g.
  • Inite: Kg/Lb/Oz.
  • Long lavi batri: Jiska 40 èdtan.
  • Auto Fèmen-off: After 10 minutes of inactivity to conserve battery.
Elitech LMC-100A+ refrigerant scale in its protective case

Figure 5: Elitech LMC-100A+ Refrigerant Scale within its carrying case.

Elitech LMC-100A+ refrigerant scale showing battery life and auto shut-off features

Figure 6: Battery life and auto shut-off features of the Elitech LMC-100A+.

Elitech ILD-200 Infrared Refrigeration Leak Detector

The ILD-200 is an advanced infrared leak detector designed to quickly and accurately pinpoint refrigerant leaks in HVAC/R systems.

  • Detects All Halogenated Gases: Including CFCs, HFCs, HCFCs, HCs, HFOs, and mixed refrigerants (e.g., R11, R22, R404a, R410a, R600a, R1234yf, AZ-50, HP62, MP39).
  • Anti-interference & High Precision: Ensures reliable detection in various environments.
  • NDIR Sensor: Provides longer sensor life.
  • Repons Enstantane: Quick detection of leaks.
  • Nòm Konfòmite: Meets SAE-2791 and SAE-2913 standards.
  • Sansiblite Maksimòm: 0.1oz/yr.
  • Batri: 3.7V 3000mAh.
  • Sètifika CE: Sètifye pou sekirite ak kalite.
Elitech ILD-200 infrared refrigerant leak detector

Figure 7: Elitech ILD-200 Infrared Refrigerant Leak Detector.

Elitech ILD-200 infrared refrigerant leak detector showing features like anti-interference and NDIR sensor

Figure 8: Key features of the Elitech ILD-200.

Elitech ILD-200 infrared refrigerant leak detector dimensions and specifications

Figure 9: Dimensions and detailed specifications of the Elitech ILD-200.

Enstalasyon

Before operating the Elitech HVAC/R service kit, ensure all components are properly set up and charged.

  1. Debake: Carefully remove all items from the packaging. Verify that all components listed in the packing list are present and undamaged.
  2. Battery Installation/Charging:
    • LMG-10W: Ensure the manifold gauge is charged or has sufficient battery life. Refer to the individual LMG-10W manual for specific battery type and charging instructions.
    • LMC-100A+: Install batteries as per the scale's instructions.
    • ILD-200: Charge the leak detector using the provided charger until the battery indicator shows full.
  3. App Installation (Optional but Recommended): Download the "Elitech Tools" app from your device's app store (iOS and Android). This app allows for integrated management of Elitech tools.
  4. Initial Calibration/Zeroing:
    • LMG-10W: Power on the manifold gauge. Perform a zero calibration as instructed in its specific manual to ensure accurate pressure readings.
    • LMC-100A+: Place the scale on a flat, stable surface. Power it on and press the "Z/T" button to zero the scale before placing any refrigerant cylinders on it.
    • ILD-200: Allow the leak detector to warm up as per its instructions. Ensure it is in a clean air environment when powered on to establish a baseline.
  5. Hose Connection (LMG-10W): Connect the appropriate refrigerant hoses to the LMG-10W manifold gauge and to the HVAC/R system service ports as required for your specific task (e.g., charging, recovery, evacuation).

Enstriksyon Operasyon

This section provides general operating guidelines for using the Elitech HVAC/R service kit. Always refer to the specific manuals for each device for detailed operational procedures.

Refrigerant Charging/Recovery (Using LMG-10W and LMC-100A+)

  1. Konekte kawotchou: Connect the LMG-10W to the HVAC/R system's high and low-pressure service ports using the appropriate hoses. Connect the center hose to the refrigerant cylinder or recovery machine.
  2. Place Cylinder on Scale: Place the refrigerant cylinder on the LMC-100A+ scale. Ensure the scale is zeroed before placing the cylinder.
  3. Siveye Lekti: Use the LMG-10W to monitor system pressures and temperatures. The LMC-100A+ will display the refrigerant weight.
  4. Charge/Recover: Open the manifold valves as required for charging or recovery. Monitor the LMC-100A+ to ensure the correct amount of refrigerant is transferred.
  5. Dekonekte: Once the process is complete, close all valves and carefully disconnect the hoses.

Leak Detection (Using ILD-200)

  1. Pouvwa sou: Turn on the ILD-200 leak detector. Allow it to warm up and self-calibrate in a clean air environment.
  2. Ajiste sansiblite: Adjust the sensitivity setting (Low, Medium, High) based on the suspected leak size and environment. Start with a higher sensitivity for general scanning.
  3. Scan System: Slowly move the probe tip around suspected leak areas (e.g., joints, fittings, valves, coils). The detector will alarm and indicate the presence of refrigerant.
  4. Pinpoint Leak: Once a leak is detected, move the probe slowly back and forth to pinpoint the exact source. The alarm intensity will typically increase as you get closer to the leak.
  5. Verifye: After identifying a leak, ventilate the area and re-scan to confirm the leak location.

Antretyen

Proper maintenance ensures the longevity and accuracy of your Elitech HVAC/R service kit.

Depanaj

This section addresses common issues you might encounter with your Elitech HVAC/R service kit.

PwoblèmKòz posibSolisyon
LMG-10W: Lekti presyon ki pa egzak.Needs zero calibration; sensor contamination; faulty hose connection.Perform zero calibration. Clean sensor if accessible. Check hose connections for leaks or blockages.
LMG-10W: Ekspozisyon pa limen.Low battery; power button issue.Charge the device. Press and hold the power button firmly.
LMC-100A+: Lekti pwa ki pa egzak.Scale not zeroed; unstable surface; battery low.Zero the scale before use. Place on a flat, stable surface. Replace batteries.
LMC-100A+: Echèl pa limen.Pil mouri; move enstalasyon pil.Ranplase pil yo. Asire w ke pil yo mete ak polarite ki kòrèk la.
ILD-200: No leak detection/false alarms.Sensor contaminated; low sensitivity setting; strong air currents.Clean sensor tip. Increase sensitivity. Shield the area from drafts.
ILD-200: Aparèy pa alimante.Battery depleted; power button issue.Charge the device fully. Press and hold the power button.

Espesifikasyon

Detailed specifications for each component of the Elitech HVAC/R service kit.

Elitech LMG-10W 2-Way Valve Manifold Gauge

Elitech LMC-100A+ Refrigerant Scale

Elitech ILD-200 Infrared Refrigeration Leak Detector

Garanti ak sipò

Elitech provides dedicated customer support for its products.

For technical questions, troubleshooting assistance, or warranty inquiries, please contact Elitech's US-based customer service team. They are available 24/7 via email or phone.

Refer to the Elitech official websit la oswa anbalaj pwodwi a pou jwenn enfòmasyon kontak ki pi resan yo.

Dokiman ki gen rapò - LMG-10W, LMC-100A+, ILD-200

Preview Elitech ILD Seri enfrawouj detektè fwit frijidè manyèl itilizatè
Manyèl itilizatè konplè pou detektè flit frijidè enfrawouj seri Elitech ILD yo (ILD-100, ILD-200, ILD-300), ki kouvri espesifikasyon yo, operasyon an, antretyen an ak karakteristik yo. Aprann kijan pou detekte flit frijidè efektivman ak aparèy avanse sa a.
Preview Manyèl Itilizatè Detektè Fwit Enfrawouj Elitech ILD-100/ILD-200/ILD-300
Manyèl itilizatè pou detektè flit frijidè enfrawouj seri Elitech ILD (ILD-100, ILD-200, ILD-300). Li bay enfòmasyon detaye sou operasyon, espesifikasyon, karakteristik ak antretyen pou yon deteksyon flit frijidè ki egzat.
Preview Elitech MS-100 PLUS Smart Digital Manifold Gauge User Manual
Comprehensive user manual for the Elitech MS-100 PLUS Smart Digital Manifold Gauge, covering product introduction, safety instructions, overview, button functions, technical parameters, and quick operation guides for refrigeration and HVAC systems.
Preview Manyèl Itilizatè Detektè Fwit Dyòd Enfrawouj ak Chofe Elitech IR-200
Manyèl itilizatè konplè pou Elitech IR-200 la, yon detektè flit ak doub captè ki prezante teknoloji enfrawouj ak dyòd chofe. Aprann plis sou espesifikasyon li yo, operasyon li, antretyen li, ak karakteristik li yo pou detekte flit frijidè.
Preview Elitech WJL-6000S Corona Detektè Manyèl Itilizatè
Manyèl itilizatè pou Detektè Corona Elitech WJL-6000S la, ki bay enstriksyon detaye sou operasyon, deteksyon, depanaj ak antretyen pou deteksyon flit refrijeran nan divès sistèm.
Preview Manyèl Itilizatè Kalib Manifoul Dijital Elitech Seri MS
Manyèl itilizatè pou kalib dijital manifoul Elitech Seri MS la, ki kouvri deskripsyon pwodwi a, jeneral sou sijè a.view, fonksyon bouton, espesifikasyon, gid demaraj rapid, etap operasyon, aplikasyon entelijan, ak antretyen.