1. Enstriksyon Sekirite Enpòtan
Please read and understand all safety instructions before operating your ALLPOWERS R600 portable power station. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Pa demont, repare, oswa modifye inite a.
- Pa mete aparèy la toupre sous chalè oswa anba limyè solèy dirèk pou yon bon bout tan.
- Evite ekspoze a lapli oswa imidite.
- Sèvi ak sèlman kab chaje ak akseswa orijinal oswa sètifye.
- Kenbe lwen timoun ak bèt kay.
- Asire w ke sistèm nan byen vantile pandan w ap itilize l epi pandan w ap chaje l.
- Pa mete objè etranje nan pò yo.
- Nan ka dife, sèvi ak yon aparèy pou etenn dife poud sèk.
The ALLPOWERS R600 includes multiple protection features: High Temperature protection, Low Temperature protection, Over Discharge protection, Over Charge protection, Over Load protection, Short Circuit protection, and Over Current protection.

Imaj: Entèn view of the ALLPOWERS R600 highlighting the LiFePO4 battery and its comprehensive safety protection systems.
2. Pwodwi souview
The ALLPOWERS R600 is a portable power station designed to provide reliable power for various applications, from outdoor camping to home backup. It features a durable LiFePO4 battery, multiple output ports, and a fast-charging capability.
2.1 Kontni pake a
- ALLPOWERS R600 Portable Power Station
- AC chaje kab
- Solè chaje kab
- Manyèl itilizatè
- Kat Garanti
2.2 Unit Diagram and Ports
Familiarize yourself with the various components and ports of your R600 unit.

Imaj: Devan ak bò view of the ALLPOWERS R600, detailing the location and type of each port and control button.
- Priz kouran altènatif (x2): 110V, 600W Max (1200W surge)
- Pò USB-A (x2): 18W Max
- Pò USB-C (x2): 100W Max
- Cigarette Lighter Port (x1): 120W Max
- Wireless Charger (x1): 15W Max
- Pò Antre AC: For wall charging (400W Max)
- Solar Input Port (XT60): For solar panel charging (220W Max)
- Ekspozisyon LCD: Shows charge percentage, input/output power, time remaining, and status indicators.
- Pouvwa sou / Off bouton: Kontwòl prensipal pouvwa a.
- Bouton On/Off AC: Aktive/dezaktive priz kouran AC yo.
- DC On/Off Button: Activates/deactivates DC outputs (USB, cigarette lighter).
- Limyè ki ap dirije: Built-in illumination.
- Bouton Reyajiste: Pou reset sistèm nan.
- Pwoteksyon Surcharge: Safety feature.
2.3 Endikatè ekran LCD
The LCD display provides real-time information about the power station's status.

Imaj: Detaye view of the LCD screen with numbered labels explaining each indicator, such as charge percentage, input/output power, time remaining, and various mode icons.
- Pousantage nan chaj
- Antre pouvwa (W)
- Pouvwa pwodiksyon (W)
- AC pwodiksyon nimewo hertz
- Time remaining (for charge/discharge)
- Power saving mode indicator
- Fast charge mode indicator
- Endikatè mòd bèbè
- Output overload indicator
- DC pwodiksyon endikatè
- Endikatè pwodiksyon AC
- UPS indicator
- Fan operating indicator
- Car charge output indicator
- Endikatè koneksyon Bluetooth
3. Enstalasyon ak Premye Itilizasyon
3.1 Debalaj ak enspeksyon
Upon receiving your ALLPOWERS R600, carefully unpack all components and inspect for any damage. If any items are missing or damaged, contact ALLPOWERS customer support immediately.
3.2 Premye chaj
It is recommended to fully charge the R600 before first use. This helps calibrate the battery management system (BMS) for accurate charge percentage lekti.
- Connect the provided AC charging cable to the AC input port on the R600.
- Ploge lòt bout la nan yon priz estanda miray la.
- The LCD display will show the input power and charging status. The unit will fully charge in approximately 1 hour.
Note: The R600 supports three charging modes: Fast Mode (400W Max), Standard Mode (300W Max), and Mute Mode (100W Max). These can be adjusted via the ALLPOWERS app or unit settings.

Image: The ALLPOWERS R600 being charged via an AC wall outlet, illustrating the different charging speed modes available.
4. Operasyon
4.1 Limen/Etenyen
- To turn on: Press and hold the main Power On/Off button until the LCD screen illuminates.
- To turn off: Press and hold the main Power On/Off button until the LCD screen turns off and the unit beeps.
4.2 Itilizasyon Sòti AC yo
- Ensure the R600 is powered on.
- Press the AC On/Off button to activate the AC outlets. The AC indicator will appear on the LCD.
- Plug your AC devices into the outlets.
- To turn off AC outputs, press the AC On/Off button again.
Caution: Do not exceed the maximum 600W continuous output. The unit supports a 1200W surge, but sustained loads above 600W will trigger overload protection.
4.3 Itilizasyon Sòti DC ak USB yo
- Ensure the R600 is powered on.
- Press the DC On/Off button to activate the DC outputs (USB-A, USB-C, Cigarette Lighter, Wireless Charger). The DC indicator will appear on the LCD.
- Konekte aparèy ou yo nan pò ki apwopriye yo.
- To turn off DC outputs, press the DC On/Off button again.
4.4 Fonksyon Sistèm Alimantasyon san Enteripsyon (UPS)
The R600 features a UPS function, providing seamless power during outages.
- Connect the R600 to a wall outlet using the AC charging cable.
- Plug your critical devices (e.g., computer, router) into the AC outlets of the R600.
- When the wall power is interrupted, the R600 will automatically switch to battery power in less than 10 milliseconds, preventing device shutdown.

Image: The ALLPOWERS R600 acting as an Uninterruptible Power Supply (UPS) for a desktop computer, ensuring continuous power during an outage.
4.5 ALLPOWERS App Control
Control and monitor your R600 remotely via the ALLPOWERS mobile application.
- Download the ALLPOWERS app from your device's app store.
- Asire w ke Bluetooth aktive sou smartphone ou.
- On the R600, press the DC output button twice (one short press, one long press) to activate Bluetooth pairing. The Bluetooth icon will appear on the LCD.
- Open the app and follow the on-screen instructions to connect to your R600.
- Through the app, you can monitor battery status, control outputs, and adjust charging modes (Mute/Standard/Fast Mode) and Eco mode settings.

Image: A smartphone screen showing the ALLPOWERS app, which allows users to monitor and control the R600 power station remotely via Bluetooth.
5. Charging the ALLPOWERS R600
The R600 offers multiple charging options to suit your needs.
5.1 AC miray chaje
Connect the provided AC charging cable to the R600's AC input port and a standard wall outlet. Max input is 400W, allowing a 0-100% charge in approximately 1 hour.
5.2 Solè chaje
Utilize solar panels (sold separately) to charge your R600 sustainably.
- Connect your solar panel(s) to the R600's XT60 solar input port using the provided solar charging cable.
- Position the solar panels in direct sunlight for optimal charging efficiency.
- The R600 supports up to 220W max solar input.

Image: The ALLPOWERS R600 being charged by solar panels in an outdoor environment, showcasing its solar input feature.
5.3 Chaje machin
Charge your R600 from your vehicle's 12V cigarette lighter port.
- Connect a car charging cable (not included, available separately) to the R600's DC input port.
- Branche lòt bout la nan priz alimyè sigarèt 12V machin ou an.
- The R600 supports up to 200W max car input.

Image: The ALLPOWERS R600 charging inside a vehicle using the car's 12V power outlet.
6. Antretyen ak Depo
6.1 Swen Batri
The ALLPOWERS R600 uses LiFePO4 battery cells, designed for longevity (3500+ cycles, 6X longer lifespan than traditional batteries, up to 10 years of regular use).
- Pou yon batri ki an bon eta, evite vide batri a nèt souvan.
- Si w ap sere l pou yon bon bout tan, chaje aparèy la apeprè 50-80% epi rechaje l chak 3-6 mwa.
- Sere nan yon kote ki fre, sèk lwen limyè solèy la dirèk ak tanperati ekstrèm.
6.2 Netwayaj
Wipe the unit with a dry, soft cloth. Do not use abrasive cleaners or immerse the unit in water.
NAN. Depanaj
If you encounter issues with your ALLPOWERS R600, refer to the following common solutions:
7.1 Unit Not Turning On or Charging
- Ensure the main Power On/Off button is pressed and held until the screen illuminates.
- Check if the AC charging cable is securely connected to both the unit and the wall outlet.
- Verifye si priz miray la fonksyone byen.
- If using solar, ensure panels are in direct sunlight and connections are secure.
- If the unit was completely drained, it might take a few minutes for the screen to respond after connecting to power.
- Try pressing the Reset Button if available (refer to unit diagram).
7.2 AC/DC Outputs Not Working
- Ensure the respective AC On/Off or DC On/Off button has been pressed and the corresponding indicator is visible on the LCD.
- Check if the total power draw of connected devices exceeds the R600's output capacity (600W for AC). If an overload occurs, the overload protector may trip. Disconnect devices, press the reset button (if applicable), and restart.
- Verify that the devices themselves are functioning correctly.
7.3 Pwoblèm Koneksyon Bluetooth
- Asire w ke Bluetooth aktive sou smartphone ou.
- Activate Bluetooth on the R600 by pressing the DC output button twice (short press, then long press). The Bluetooth icon should appear on the LCD.
- Make sure the R600 is within Bluetooth range of your smartphone.
- Restart the ALLPOWERS app and try pairing again.
7.4 UPS Function Not Activating
- Ensure the R600 is connected to both the wall outlet and the device you wish to protect.
- Confirm that the R600 is powered on and the AC output is active.
8. Espesifikasyon
Detailed technical specifications for the ALLPOWERS R600 Portable Power Station.
| Karakteristik | Spesifikasyon |
|---|---|
| Non modèl | AP-SS-005PRO-CA (R600) |
| Kapasite batri | 299Wh |
| Kalite batri | LiFePO4 |
| AC Sòti | 600W (Pure Sine Wave), 1200W Surge, 110V |
| USB-A Sòti | 2 x 18W Max |
| USB-C Sòti | 2 x 100W Max |
| Sigarèt pi lejè Sòti | 1 x 120W Max |
| Wireless Charger | 1 x 15W Max |
| AC Antre | 400W Max |
| Solar Input (XT60) | 220W Max |
| Machin Antre | 200W Max |
| Fonksyon UPS | Wi (<10ms chanjman) |
| Dimansyon | 7.6"L x 11.2"L x 7.5"H |
| Pwa | 12.8 liv |
| Tanperati Fonksyònman | Gade direktiv manifakti a |
Nòt: Espesifikasyon yo ka chanje san avètisman. Gade etikèt pwodwi a pou jwenn enfòmasyon ki pi egzak yo.
9. Garanti ak sipò
The ALLPOWERS R600 Portable Power Station comes with a 6-ane garanti, ensuring a worry-free experience.
- For warranty claims or technical support, please contact ALLPOWERS customer service.
- Have your purchase receipt and product serial number ready when contacting support.
- Contact information can typically be found on the ALLPOWERS official website or the warranty card included in your package.