U.S. Solid USS-SV-Parent05

U.S. Solid 2-Inch 110V AC Brass Electric Solenoid Valve Instruction Manual

Model: USS-SV-Parent05

1. Entwodiksyon

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your U.S. Solid 2-Inch 110V AC Brass Electric Solenoid Valve. Please read these instructions thoroughly before installation and retain this manual for future reference.

The U.S. Solid 2-Inch 110V AC Brass Electric Solenoid Valve is a normally closed, two-port, two-position valve designed for controlling the flow of various media. Constructed from industrial-grade brass with a Viton seal, it offers corrosion resistance and is suitable for a wide range of applications, including those involving gasoline, diesel fuel, kerosene oil, natural gas, air, and drinking water.

U.S. Solid 2-inch 110V AC Brass Electric Solenoid Valve, front-side view.

This image displays the U.S. Solid 2-inch 110V AC Brass Electric Solenoid Valve from a front-side perspective, highlighting its brass body and black solenoid coil with red electrical wires.

2. Enfòmasyon sou Sekirite

  • Sekirite elektrik: Ensure all electrical connections are made by a qualified professional and comply with local electrical codes. Disconnect power before installation or maintenance.
  • Pressure and Temperature: Do not exceed the maximum operating pressure or temperature specified for this valve.
  • Medya konpatibilite: Verify that the valve material (brass) and seal material (Viton) are compatible with the fluid or gas being controlled.
  • Sik devwa: This valve is PA a continuous duty valve. It should not be in continuous use for more than 10 hours in a single cycle. Exceeding this limit can shorten the valve's lifespan and may cause the solenoid coil to burn out. For applications requiring continuous duty, consider U.S. Solid Motorized Ball Valves.
  • Direksyon koule: Always observe the flow direction arrow stamped on the valve body to ensure correct installation. Incorrect installation can lead to improper operation.
  • Avètisman Pwopozisyon 65 Kalifòni: This product can expose you to Lead, which is known to the State of California to cause cancer. For more information, visit www.P65Warnings.ca.gov.
Information graphic on IP65 rating, seal materials, overheating warning, and California Proposition 65.

This graphic provides crucial information: the valve's IP65 ingress protection rating (dust-tight, protected from water jets), details on VITON and NBR seal materials and their temperature ranges, a warning against continuous operation for more than 8 hours to prevent overheating, and the California Proposition 65 warning regarding lead exposure.

3. Pwodwi Features

  • Konstriksyon dirab: Made from industrial-grade brass for corrosion resistance and suitability in various environments.
  • Viton Seal: Equipped with a high-performance Viton seal, offering excellent resistance to high temperatures and corrosive chemicals, including gasoline, diesel fuel, oils, and lubricants.
  • Repons rapid: Opens and closes in less than 3 seconds when actuated, providing instantaneous flow control.
  • Operasyon nòmalman fèmen: The valve remains closed when de-energized and opens when electrical power is applied.
  • Gamme Aplikasyon Lajè: Suitable for use with water (including drinking water), air, natural gas, gasoline, diesel fuel, and kerosene oil.
  • Lavi Sik Segondè: Engineered for over a million cycles under proper operating conditions and maintenance.

4. Espesifikasyon

SpesifikasyonDetay
Nimewo ModèlUSS-SV-Parent05
Kalite valv2-Way, Normally Closed
Materyèl kòKwiv
Materyèl seleViton
Voltage110V AC
Inlet/Outlet Connection Size2 pous
Kalite KoneksyonNPT (National Pipe Tapered)
Maksimòm Presyon Fonksyònman101 PSI (liv pou chak pous kare)
Operating Temperature Range (Viton)-10 ° C a 120 ° C (14 ° F a 148 ° F)
Tan reponsMwens pase 3 segonn
Evalyasyon Pwoteksyon Ingress (IP).IP65 (Dust-tight, protected from water jets)
Kantite pò2
Dimansyon atik (L x W x H)7.9 x 6.9 x 5 pous
Pwa atik9.3 liv
SètifikasyonCE
Diagram showing dimensions of the U.S. Solid 2-inch solenoid valve.

An illustration detailing the physical dimensions of the solenoid valve, including its height (7.1 inches), width (5.3 inches), and coil width (3.6 inches), along with its weight (6.4 lbs).

Close-up of the U.S. Solid solenoid valve label with specifications.

Yon detaye view of the label on the solenoid coil, indicating model number (USS2-00116), orifice size (50mm), pipe size (2"), volts (AC110V), temperature range (-10°C to 120°C), and pressure ratings for air/water and oil.

5. Enstalasyon ak Enstalasyon

5.1 Chèk Pre-Enstalasyon

  • Inspect the valve for any signs of damage during shipping.
  • Ensure the valve's specifications (voltage, pressure, temperature, media compatibility) match your application requirements.
  • Confirm that the power supply is disconnected before beginning installation.

5.2 Mounting the Valve

  1. Identify the inlet and outlet ports. The valve body has a flow direction arrow stamped on it. Ensure the valve is installed so that the fluid or gas flows in the direction indicated by the arrow.
  2. Apply appropriate thread sealant (e.g., PTFE tape or pipe dope) to the NPT threads of your piping connections.
  3. Thread the valve onto the pipes, ensuring a secure, leak-free connection. Do not overtighten, as this can damage the valve or threads.
  4. Mount the valve in a position that allows for easy access for electrical connections and future maintenance. The valve can be mounted in any orientation, but vertical mounting with the solenoid coil upwards is generally recommended for optimal performance and lifespan.
Side view of the U.S. Solid 2-inch 110V AC Brass Electric Solenoid Valve.

Yon bò view of the solenoid valve, showing the brass body, the black solenoid coil, and the electrical connections. A flow direction arrow is visible on the brass housing, indicating proper installation orientation.

5.3 Koneksyon elektrik

  1. Ensure the power supply is OFF.
  2. Connect the two electrical wires from the solenoid coil to your 110V AC power source. This valve is not polarity sensitive for AC power.
  3. Secure all electrical connections to prevent accidental disconnection or short circuits.
  4. Once connections are complete, you may restore power and test the valve's operation.

6. Operasyon Enstriksyon

The U.S. Solid 2-Inch 110V AC Brass Electric Solenoid Valve is a normally closed valve. This means it will remain in the closed position, blocking flow, when no electrical power is supplied to the solenoid coil.

  1. Pou ouvri valv la: Apply 110V AC electrical power to the solenoid coil. The valve will open rapidly (in less than 3 seconds), allowing fluid or gas to flow through.
  2. Pou fèmen valv la: Remove the 110V AC electrical power from the solenoid coil. The valve will close rapidly (in less than 3 seconds), stopping the flow.

Important Operating Considerations:

  • Sik devwa: As noted in the safety section, this valve is designed for intermittent use. Avoid continuous operation for more than 10 hours in a single cycle to prevent overheating and premature failure of the solenoid coil.
  • Media Purity: While the valve is robust, using clean media free of large particulates will help prolong its lifespan and prevent blockages.
Diagram illustrating direct, semi-direct, and pilot-operated solenoid valve mechanisms.

A diagram explaining the operational principles of different solenoid valve types: direct-acting, semi-direct-acting, and pilot-operated, showing how they open and close when de-energized and energized. This U.S. Solid valve operates as a direct-acting or semi-direct valve.

7. Antretyen

Regular maintenance helps ensure the longevity and reliable operation of your solenoid valve.

  • Enspeksyon peryodik: Periodically inspect the valve for any signs of leaks, corrosion, or damage to the electrical wiring.
  • Netwayaj: If operating with media that may leave residue, occasional cleaning of the internal components may be necessary. Ensure power is disconnected and pressure is relieved before disassembling the valve.
  • Ranplasman sele: The Viton seal is durable but may eventually wear out. If leaks occur around the valve body or plunger, the seal may need replacement. Contact U.S. Solid support for replacement parts.
  • Bobin Solenoid: The solenoid coil is generally maintenance-free. If the valve fails to actuate, check the electrical connections and ensure the coil is receiving the correct voltage.

NAN. Depanaj

PwoblèmKòz posibSolisyon
Valve does not open when energizedNo power to coil; Incorrect voltage; Damaged coil; Obstruction in valve; Incorrect flow directionCheck electrical connections and power supply; Verify correct 110V AC voltage; Inspect coil for damage (replace if necessary); Disassemble and clean valve; Reinstall valve in correct flow direction.
Valve does not close when de-energizedCoil remains energized; Obstruction preventing closure; Damaged seal/internal componentsCheck power supply to ensure it's disconnected; Disassemble and clean valve; Inspect and replace seals or internal components if damaged.
Flit nan kò valv laLoose connections; Damaged seals; Cracked valve bodyTighten pipe connections (ensure proper thread sealant); Inspect and replace internal seals; Replace valve if body is cracked.
Valve overheats during operationContinuous operation exceeding duty cycle; High ambient temperatureEnsure operation adheres to the 10-hour maximum continuous duty cycle; Improve ventilation around the valve if ambient temperatures are high.

9. Garanti ak sipò

U.S. Solid provides a YON ANE GARANTI for this solenoid valve from the date of purchase. If the valve becomes defective within the first year due to manufacturing defects, U.S. Solid will gladly replace it.

For technical support, warranty claims, or inquiries regarding replacement parts, please contact U.S. Solid customer service through their official websit la oubyen détayan kote yo te achte pwodwi a.

Dokiman ki gen rapò - USS-SV-Parent05

Preview U.S. Solid Motorized Ball Valve Installation and Maintenance Manual
Comprehensive guide for U.S. Solid Motorized Ball Valves, covering installation, wiring schematics, DC/AC operation, manual override, FAQs, environmental protection, warranty, and detailed specifications for models USS-MSV00201-216.
Preview U.S. Solid Electric Ball Valve (Two-Way) - USS-EBV Models Instruction Manual
Instruction manual for U.S. Solid USS-EBV series electric ball valves, covering product features, specifications, wiring diagrams, manual operation, and frequently asked questions.
Preview U.S. Solid USS-HSV Solenoid Valves: Installation and Maintenance Manual
Comprehensive guide for installing and maintaining U.S. Solid USS-HSV series solenoid valves, covering high pressure, vacuum, high temperature, and explosion-proof models with detailed specifications and safety instructions.
Preview U.S. Solid Motorized Ball Valves: Installation, Maintenance, and Specifications
Comprehensive guide to the installation, maintenance, manual operation, and specifications of U.S. Solid Motorized Ball Valves, including wiring schematics and FAQs.
Preview U.S. Solid Smart Solenoid Valve: Instruction Manual & Operation Guide
Comprehensive instruction manual for the U.S. Solid Smart Solenoid Valve (Version 23.05), detailing setup, Wi-Fi connection via eWeLink app, scheduling, timers, and third-party integrations.
Preview U.S. Solid Motorized Ball Valves: Installation and Maintenance Manual
Comprehensive installation and maintenance manual for U.S. Solid Motorized Ball Valves (USS-MSV series). Covers product features, threading standards (NPT, BSPT), wiring schematics, manual operation procedures, frequently asked questions, technical specifications, warranty information, and environmental disposal guidelines.