The Elitech CLD-100 Refrigerant Leak Detector is an advanced tool designed for precise detection of halogenated refrigerants, including CFCs, HCFCs, and HFCs. This manual provides comprehensive instructions for the proper setup, operation, and maintenance of your CLD-100 detector to ensure optimal performance and longevity.
2. Karakteristik kle
- Upgraded Corona Sensor: Features a traditional corona sensor with an updated analog circuit for fast detection of R11, R22, R134A, R404a, R410A, and all halogenated refrigerants, including HFCs, CFCs, HCFCs, and blends.
- Rapid Response: Offers a quick 6-second preheating time and instantaneous response to refrigerant leaks.
- Sansiblite reglabl: Provides 6 adjustable sensitivity levels, with a maximum sensitivity of 0.21 oz/yr, allowing for precise leak identification.
- Sond fleksib: Equipped with an 8.26-inch flexible probe for easy access to difficult and hard-to-reach areas.
- Audible & Visual Alarms: Direct status indication with clear audible and visual leakage alarms.
- Dual Color Battery Indicators: Provides clear indication of battery status.
- Integrated UV Light: Includes a UV light feature to assist in detecting refrigerant leaks that contain UV dye, often visible as oil spotting.

Figure 2.1: Elitech CLD-100 highlighting its main features.
3. Pake kontni
Lè w ap ouvri pake a, tanpri verifye si tout atik ki nan lis anba a yo la epi yo an bon eta:
- 1 x Elitech CLD-100 Refrigerant Leak Detector
- 1 x pote sak
- 1 x Manyèl Itilizatè (dokiman sa a)
- 1 x UV Light attachment

Figure 3.1: Contents included in the Elitech CLD-100 package.
4. Pwodwi souview
Familiarize yourself with the main components of the Elitech CLD-100 detector:

Figure 4.1: Main components of the CLD-100 detector.
- Sond fleksib: Allows for reaching confined spaces.
- Limyè UV: Aids in detecting leaks with fluorescent dye.
- Sensor Tip: The primary detection point for refrigerants.
- Limyè Endikatè: Provides visual feedback on leak detection and battery status.
- Buzzer: Emits an audible alarm when a leak is detected.
- Power On/Off & Sensitivity Adjustment Switch: Rotary knob to power on/off and select sensitivity levels.
- Lòj batri: Located at the bottom, holds 4 AAA batteries (not included).
5. Enstalasyon
Anvan premye itilizasyon an, enstale pil yo:
- Locate the battery compartment cover at the bottom of the detector.
- Open the cover and insert 4 AAA batteries, ensuring correct polarity (+/-).
- Byen fèmen kouvèti lòj batri a.
Remak: Batri yo pa enkli nan pake a.

Figure 5.1: Elitech CLD-100 ready for use.
6. Operasyon Enstriksyon
Follow these steps to operate your Elitech CLD-100 detector:
- Pouvwa sou: Turn the Power On/Off & Sensitivity Adjustment Switch to the "ON" position. The detector will emit a continuous beeping sound, indicating it is preheating.
- Prechofaj: Allow approximately 6 seconds for the detector to preheat and stabilize. The beeping sound will become steady.
- Ajiste sansiblite: Rotate the switch to select the desired sensitivity level (1-6). For maximum sensitivity, it is recommended to turn the device on outdoors, away from any potential refrigerant sources, to allow it to calibrate to the ambient environment.
- Deteksyon koule:
- Point the flexible probe towards the area suspected of a leak.
- Move the probe slowly (approximately 1 inch per second) around the suspected leak points, such as AC system high-side and low-side lines, condenser coils, and compressor gaskets.
- If a refrigerant leak is detected, the beeping sound will increase in frequency, and the indicator light will change, signaling the presence of a leak. The closer the probe is to the leak, the faster the beeping will become.
- Fonksyon limyè UV: The UV light feature can be activated by sliding the light switch on the probe.
- The light has two settings: a regular flashlight mode for illuminating dark work areas and a UV light mode.
- When a refrigerant leak occurs, it often involves oil mixed with the refrigerant. If a UV dye has been added to the system, the UV light will illuminate any oil spotting, helping to pinpoint the exact leak location.
- Pouvwa Off: When finished, turn the Power On/Off & Sensitivity Adjustment Switch to the "OFF" position.

Figure 6.1: Using the CLD-100 for quick leak detection.

Figure 6.2: The CLD-100 is capable of detecting a wide range of halogenated refrigerants.
7. Espesifikasyon

Figure 7.1: Key specifications of the CLD-100 detector.
| Atribi | Valè |
|---|---|
| Mak | Elitech |
| Modèl | CLD-100UV |
| Style | Endistriyèl |
| Sous pouvwa | Batri Powered (4 pil AAA obligatwa, pa enkli) |
| Koulè | Orange |
| Dimansyon pwodwi (D x W x H) | 8.66" x 2.36" x 2.36" |
| Pwa atik | 3.53 ons (100 gram) |
| Materyèl | Plastik |
| Max sansiblite | 0.21 oz/yr |
| Tan prechofaj | 6 segonn |
| Tan repons | Enstantane |
| Tanperati travay | 0°C - 52°C |
| Lavi batri | ~ 50 èdtan |
| Peyi orijin | Lachin |
8. Antretyen
To ensure the longevity and accuracy of your Elitech CLD-100, follow these maintenance guidelines:
- Netwayaj: Wipe the detector with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Swen Capteur: The sensor tip is a delicate component. Avoid physical damage and keep it clean. Over time, the sensor may wear out or become unstable, requiring replacement for optimal performance.
- Ranplasman batri: Replace batteries when the dual color battery indicators show low power. Always use fresh AAA batteries.
- Depo: Store the detector in its provided carry bag in a cool, dry place when not in use.
NAN. Depanaj
If you encounter issues with your CLD-100, refer to the following common problems and solutions:
| Pwoblèm | Kòz posib | Solisyon |
|---|---|---|
| Detector not turning on. | Pil ki mouri oswa ki mal enstale. | Tcheke polarite pil yo epi ranplase yo ak nouvo pil AAA. |
| Constant beeping or false positives. | High sensitivity setting in a contaminated environment; sensor needs calibration or replacement. | Turn on the device in a clean, outdoor environment for proper calibration. Reduce sensitivity if necessary. If problem persists, consider sensor replacement. |
| No detection or low sensitivity. | Low battery; sensor tip is dirty or worn out; sensitivity setting too low. | Replace batteries. Clean the sensor tip. Increase sensitivity. If still no detection, the sensor may need replacement. |
| Limyè UV a pa fonksyone. | Light switch not activated; low battery. | Ensure the light switch is fully engaged. Check and replace batteries if needed. |
Pou plis asistans, tanpri kontakte sèvis kliyan Elitech.
10. Garanti & Sipò
Elitech stands behind the quality of its products. For any technical assistance, warranty claims, or product inquiries, please utilize our dedicated support channels:
- US Technician Support: Available 24/7 via Email and Phone.
- Please refer to the product packaging or Elitech's official websit la pou jwenn enfòmasyon kontak espesifik.
For more information about Elitech and our range of products, visit the Magazen Elitech.