Entwodiksyon
Thank you for choosing the PRIME 12,000 BTU Ductless Air Conditioner and Heat Pump Mini Split system. This manual provides essential information for the safe and efficient operation, installation, and maintenance of your new unit. Please read this manual thoroughly before installation and use, and keep it for future reference.
This versatile system offers 5 modes for your comfort: Auto, Cool, Dry, Heat, and Fan. It is designed for ease of control with the included backlit LCD remote controller, ensuring optimal climate control in your space. The PRIME mini split system is engineered for energy efficiency, contributing to significant energy savings over time.
Enfòmasyon sou Sekirite
Pou anpeche aksidan itilizatè a oswa lòt moun ak domaj sou pwopriyete, enstriksyon sa yo dwe swiv. Move operasyon akòz inyore enstriksyon ka lakòz domaj oswa domaj.
- Enstalasyon pwofesyonèl: Installation must be performed by qualified personnel in accordance with all applicable local and national codes.
- Sekirite elektrik: Ensure the power supply matches the unit's requirements (110/120V). Do not operate with a damaged power cord or plug. Always disconnect power before servicing.
- Frijidè: This unit uses R410A refrigerant. Only qualified technicians should handle refrigerant.
- Clearance: Kenbe yon espas ase ozalantou inite andedan ak deyò yo pou bon sikilasyon lè ak bon antretyen.
- Timoun ak bèt kay: Keep children and pets away from the unit during operation and maintenance. Do not allow them to play with the unit or remote control.
- Materyèl ki ka pran dife: Pa mete materyèl ki ka pran dife oswa flite ayewosòl toupre aparèy la.
- Ekspozisyon dlo: Do not expose the indoor unit to water. Do not wash the unit with water.
Pwodwi konpozan
Your PRIME Mini Split system is shipped in two separate packages and includes the following main components:
- Inite andedan kay la
- Inite Deyò
- Full installation accessory kit with quick connector
- Backlit LCD Remote Controller
- Manyèl Itilizatè (dokiman sa a)

Image: The indoor unit (top) and outdoor unit (bottom) of the PRIME mini split air conditioner system. The indoor unit is a sleek white rectangular shape, and the outdoor unit features a protective grille over its fan and a PRIME logo.
Enstalasyon ak Enstalasyon
Installation of a ductless mini split system requires specialized tools and knowledge. It is highly recommended that installation be performed by a certified HVAC professional to ensure proper operation, safety, and warranty validity.
Debake
Carefully unpack both the indoor and outdoor units. Inspect all components for any shipping damage. Report any damage to your supplier immediately. Keep all packaging materials until the unit is fully installed and tested.

Image: Several PRIME mini split air conditioner units in their original cardboard packaging, stacked in a warehouse setting. The boxes display product information and branding.
Konsiderasyon plasman
- Inite Andedan kay la: Choose a location that allows for optimal air distribution throughout the room, away from direct sunlight or heat sources. Ensure sufficient space for maintenance.
- Deyò Inite: Select a well-ventilated area, away from obstacles that might impede airflow. Ensure it is on a stable, level surface and has proper drainage.
Koneksyon elektrik
The unit requires a 110/120V power supply. All electrical wiring must comply with local and national electrical codes. A dedicated circuit is recommended.
Koneksyon liy frijidè
The system includes a full installation accessory kit with a quick connector for the refrigerant lines. This simplifies the connection process, but proper vacuuming and leak testing are still crucial and should be performed by a professional.
Enstriksyon Operasyon
Your PRIME mini split system is controlled via the included backlit LCD remote controller. Familiarize yourself with the remote's buttons and display for optimal use.
Remote kontwòl souview
The remote features a clear LCD display showing current settings, temperature, and mode. Buttons are intuitively placed for easy access to various functions. Refer to the remote control's dedicated section in the full manual for a detailed button layout.
Mòd fonksyònman
- Mòd oto: The unit automatically selects the appropriate operating mode (Cool, Heat, or Fan) based on the room temperature and your set temperature.
- Mòd fre: Provides cooling to lower the room temperature. Adjust the temperature setting to your desired comfort level.
- Dry Mode (Dehumidify): Reduces humidity in the room without significant temperature change. Ideal for damp kondisyon yo.
- Chalè Mode: Bay chofaj pou ogmante tanperati chanm nan.
- Mòd fanatik: Circulates air without heating or cooling. You can select fan speed.
Ajisteman Tanperati
Use the temperature up/down buttons on the remote to set your desired room temperature. The display will show the set temperature.
Kontwòl vitès fanatik
The unit offers three fan speeds (Low, Medium, High) and an Auto-speed setting. In Auto-speed, the unit adjusts the fan speed automatically based on the operating mode and temperature difference.
Fonksyon dòmi
Activate the Sleep function for energy savings and quiet operation during nighttime hours. The unit will gradually adjust the temperature and fan speed for comfortable sleep.
Automatic Air Swing
The Automatic Air Swing feature ensures even distribution of conditioned air throughout the room by automatically moving the louver. This can be toggled on or off via the remote.

Image: The sleek white indoor unit of the PRIME mini split system, featuring a digital display showing "24" and a prominent green circular label indicating "Eco-friendly Refrigerant R410A".
Antretyen
Regular maintenance is crucial for the efficient and long-lasting operation of your PRIME mini split system. Always disconnect power to the unit before performing any maintenance.
Netwayaj filtè
The indoor unit is equipped with washable filters. Clean these filters every two weeks or more frequently if the unit is used heavily or in dusty environments. Dirty filters can reduce efficiency and airflow.
- Louvri panèl devan inite andedan kay la.
- Retire filtè lè yo.
- Lave filtè yo ak dlo tyèd ak yon savon dou. Rense yo byen.
- Allow the filters to dry completely in a shaded area before reinserting them. Do not expose to direct sunlight.
- Remete filtè sèk yo epi fèmen panèl devan an.
Netwayaj Inite Eksteryè
Periodically check the outdoor unit for debris, leaves, or dirt that may accumulate on the coils or fan blades. Gently clean with a soft brush or vacuum. Do not spray water directly onto electrical components.
Antretyen sezonye
Before the start of each cooling or heating season, it is advisable to have a qualified technician perform a comprehensive check of the system, including refrigerant levels, electrical connections, and overall performance.
Depanaj
Before contacting customer support, please refer to the following table for common issues and their potential solutions. Many minor problems can be resolved by the user.
| Pwoblèm | Kòz posib | Solisyon |
|---|---|---|
| Inite pa limen. | Pa gen kouran; disjonktè a sote; pil kontwòl remote yo mouri. | Tcheke koneksyon kouran an; retabli disjonktè a; ranplase pil kontwòl remote la. |
| Refwadisman/chofaj ensifizan. | Dirty air filters; blocked outdoor unit; wrong mode selected; low refrigerant. | Clean air filters; clear obstructions from outdoor unit; select correct mode; contact professional for refrigerant check. |
| Bri dwòl ki soti nan inite a. | Pyès ki lach; vantilatè bloke; inite a pa nivo. | Check for loose screws; remove any obstructions; ensure unit is level. If noise persists, contact service. |
| Dlo ap koule nan inite andedan an. | Tiyo drenaj bouche; move enstalasyon. | Check and clear drain pipe; contact professional for inspection. |
Espesifikasyon teknik
| Karakteristik | Spesifikasyon |
|---|---|
| Non mak | PRIME (Generic) |
| Model Info / Item Model Number | e2prime |
| Nimewo Pati | 502259-444237 |
| Kapasite refwadisman | 12,000 BTU |
| Voltage | 110/120 vòlt |
| Rapò Efikasite Enèji Sezonye (SEER) | 12.6 (as per feature bullets) / 12.2 (as per specifications) |
| Nivo bri | 32 dB |
| Pwa atik | 22 pounds (likely indoor unit only, total weight is higher for two packages) |
| Capacity (Air Volume) | 550 pye kib |
| Konsomasyon enèji chak ane | 2800 kilowat èdtan pa ane |
| Kalite enstalasyon | Sistèm Split |
| Faktè fòm | Mini-Split |
| Karakteristik espesyal | Heating And Cooling Function, Sleep Function, Automatic Air Swing, Washable Filters |
| Koulè | Blan |
| Konpozan ki enkli | Indoor Unit, Outdoor Unit, Full installation accessory kit with quick connector |
| Sifas Planche Rekòmande | Jiska 600 pye kare |
| Cable Length (Refrigerant Line) | 13 pye |
| Dimansyon pwodwi (inite andedan kay la) | 7"D x 30"W x 10"H |
| Evalyasyon Zetwal BEE | 5 Star |
Enfòmasyon sou Garanti
The PRIME Mini Split system comes with a limited warranty. Specific warranty terms, including coverage duration for parts and compressor, are typically provided with the product documentation or can be obtained from your point of purchase. Please retain your proof of purchase for warranty claims.
Note: Improper installation or unauthorized servicing may void the product warranty.
Sipò pou Kliyan
If you encounter issues that cannot be resolved using the troubleshooting guide, or if you require technical assistance or parts, please contact your retailer or the manufacturer's customer support. Have your model number (e2prime) and purchase date ready when contacting support.
For the most up-to-date contact information, please refer to the packaging or the official product websit.