1. Entwodiksyon
This manual provides essential information for the proper installation, operation, and maintenance of the Fire-Lite HPF-PS6 Remote Power Supply. Please read this manual thoroughly before attempting to install or operate the unit. Retain this manual for future reference.
2. Enfòmasyon enpòtan sou sekirite
AVÈTISMAN: Risk pou chòk elektrik. Dekonekte kouran an anvan ou fè antretyen.
- Se sèlman pèsonèl kalifye ki dwe fè enstalasyon ak antretyen.
- Obsève tout kòd ak règleman elektrik lokal ak nasyonal yo.
- Asire ke ekipman pou pouvwa a byen chita.
- Pa ekspoze aparèy la nan imidite oswa tanperati ekstrèm.
- Verify opinyon voltage matches the unit's specifications (120VAC).
3. Pwodwi souview
The Fire-Lite HPF-PS6 is a 6.0 Amp, 120VAC remote power supply designed to provide reliable power for fire alarm and security systems. Its robust design ensures stable operation in critical applications.
3.1 Karakteristik kle
- 6.0 Amps output current capacity.
- 120VAC antre voltage.
- Red enclosure for easy identification in fire safety installations.
- Designed for remote power applications in fire detection signaling service.
3.2 Eleman
The HPF-PS6 unit consists of a durable red metal enclosure housing the power supply circuitry and terminal blocks for connections.

Figure 1: Fire-Lite HPF-PS6 Remote Power Supply, showing the red enclosure and Honeywell branding.
4. Enstalasyon ak Enstalasyon
Proper installation is crucial for the safe and reliable operation of the HPF-PS6. Always consult a qualified electrician or fire alarm technician for installation.
4.1 Debake
- Retire ekipman pouvwa a nan anbalaj li avèk prekosyon.
- Enspekte aparèy la pou wè si li montre nenpòt domaj pandan transpò a. Rapòte nenpòt domaj bay founisè w la imedyatman.
- Verifye ke tout konpozan ki nan lis nan fich anbalaj la prezan.
4.2 Montaj
- Select a suitable location that is dry, well-ventilated, and within the specified operating temperature range.
- Mount the unit securely to a wall or other stable surface using appropriate fasteners. Ensure the mounting surface can support the weight of the unit.
- Allow adequate clearance around the unit for ventilation and access to wiring terminals.
4.3 fil elektrik
All wiring must comply with local and national electrical codes. Refer to the wiring diagram inside the unit's enclosure for specific connection points.
- Antre pouvwa: Connect the 120VAC input power to the designated terminals. Ensure the power source is protected by an appropriate circuit breaker.
- Sòti pouvwa: Connect the output terminals to the devices requiring power, observing correct polarity.
- Atè: Asire w ke aparèy la byen konekte ak yon tè ki fyab.
- Battery Connections (if applicable): If the unit supports backup batteries, connect them according to the internal wiring diagram, observing polarity.
5. Operasyon Enstriksyon
Once properly installed and wired, the HPF-PS6 operates automatically to provide regulated power.
5.1 Limen
- After all wiring is complete and verified, apply 120VAC power to the unit.
- The unit should power up and begin supplying regulated DC power to connected devices.
5.2 Endikatè Estati yo
The HPF-PS6 may include LED indicators to show its operational status. Refer to the label on the unit or internal documentation for specific indicator meanings (e.g., Power ON, Fault, Battery Low).
6. Antretyen
The Fire-Lite HPF-PS6 is designed for minimal maintenance. However, periodic checks are recommended to ensure continued reliable operation.
- Enspeksyon anyèl: Annually inspect the unit for any signs of physical damage, loose connections, or excessive dust accumulation.
- Netwayaj: Si sa nesesè, netwaye deyò aparèy la dousman avèk yon twal sèk epi mou. Pa sèvi ak pwodui netwayaj likid oswa solvan.
- Battery Check (if applicable): If backup batteries are used, check their condition and voltage periodically as per battery manufacturer recommendations. Replace batteries as needed.
NAN. Depanaj
This section provides solutions to common issues. For problems not listed here, contact Fire-Lite technical support.
| Pwoblèm | Kòz posib | Solisyon |
|---|---|---|
| Pa gen pwodiksyon pouvwa | No 120VAC input power; Blown fuse/breaker; Internal fault. | Check input power source and circuit breaker. Verify fuses. If problem persists, contact support. |
| Endikatè Fay la ON | Overload; Short circuit on output; Battery fault (if applicable). | Check connected devices for short circuits or overloads. Inspect battery connections and condition. |
| Surchof inite | Vantilasyon ensifizan; Twòp chaj. | Ensure adequate airflow around the unit. Reduce load if exceeding specifications. |
8. Espesifikasyon teknik
| Spesifikasyon | Valè |
|---|---|
| Non modèl | HPF-PS6 |
| Manifakti | FIRE-LITE |
| Nimewo Pati | GHPFPS6 |
| Antre Voltage | 120VAC |
| Sòti aktyèl Rating | 6 Amps |
| Sòti Wattage | 720 Watts |
| Metòd refwadisman | Air |
| Kantite pake atik | 1 |
9. Garanti ak sipò
Fire-Lite products are manufactured to high standards and are backed by a limited warranty. For specific warranty terms and conditions, please refer to the documentation included with your purchase or visit the official Fire-Lite websit.
For technical support, service, or replacement parts, please contact your authorized Fire-Lite distributor or customer service representative. Provide the model number (HPF-PS6) and serial number (if applicable) when contacting support.





