OREiN OL27002

Manyèl Enstriksyon pou Limyè Inondasyon Deyò OREiN 3CCT

Modèl: OL27002

1. Entwodiksyon

Thank you for choosing the OREiN 3CCT Flood Light. This outdoor security light is designed to provide versatile and efficient illumination for your garage, yard, or other outdoor spaces. Featuring adjustable color temperature, multiple lighting modes, and a sensitive motion sensor, it enhances both security and convenience. Please read this manual thoroughly before installation and use to ensure proper operation and safety.

OREiN 3CCT Flood Light showing its design and three color temperature options

Image: The OREiN 3CCT Flood Light with examples of its 2700K (warm), 4000K (natural), and 6500K (cold) light outputs.

2. Pwodwi Features

3. Pake kontni

Tanpri verifye sa ki nan pake a pou asire w tout atik yo la epi yo pa domaje:

4. Espesifikasyon

AtribiDetay
MakOREiN
Non modèlOL27002
Kalite sous limyèLED (122 pèl)
Klète3500 Lumen
Wattage35 Watts
Tanperati Koulè2700K / 4000K / 6500K (Selectable)
Voltage120 Volts
MateryèlAliminyòm, polikarbonat
Dimansyon pwodwi7.7"L x 4.3"L x 5.3"H
Pwa atik2.2 liv
Nivo rezistans dloIP65 ki enpèmeyab
Ang Capteur Mouvman180°
Distans Capteur MouvmanJiska 40 pye
Viv lavi50,000 èdtan
SètifikasyonCE, FCC, RoHS

5. Gid Enstalasyon

This OREiN flood light is designed for hardwired installation to a standard junction box. Please ensure the power is turned off at the circuit breaker before beginning installation.

5.1 Prekosyon sekirite

5.2 Zouti ki nesesè (pa enkli)

5.3 Etap enstalasyon yo

Follow these steps to install your OREiN flood light:

  1. Prepare Bwat Koneksyon an: Ensure the existing junction box is securely mounted and the power is off. Pull the house wiring through the center of the mounting plate.
  2. Diagram showing the dimensions of the OREiN flood light and its mounting plate, indicating it's hardwired and needs a junction box.

    Image: Product dimensions and mounting plate details for hardwired installation.

  3. Tache Plak Montaj: Fix the provided mounting plate to the junction box using the screws from the hardware kit. Ensure it is flush and level.
  4. Konekte fil elektrik: Connect the wires from the flood light to the house wiring using the provided wire nuts.
    • Konekte a nwa wire from the light to the live (black) wire from the house.
    • Konekte a blan wire from the light to the neutral (white) wire from the house.
    • Konekte a ground (green or bare copper) wire from the light to the wire from the house.
    Secure all connections with electrical tape if desired.
  5. Four-step diagram showing the installation process: fixing the panel, connecting wires, securing connections, and securing the lamp.

    Image: Step-by-step visual guide for easy installation.

  6. Monte aparèy limyè a: Carefully push the connected wires into the junction box. Align the light fixture with the mounting plate and secure it using the remaining screws.
  7. Adjust Light and Sensor: Adjust the angle of the light head and the motion sensor to cover your desired area. The light can be adjusted left/right (120°) and up/down (90°). The sensor can be adjusted up/down (180°) and left/right (350°).
  8. Images showing the flood light mounted under a soffit and in a narrow corner, demonstrating flexible mounting options.

    Imaj: Egzamples of soffit and narrow space mounting.

  9. Retabli pouvwa: Yon fwa enstalasyon an fini epi tout koneksyon yo byen fèm, limen kouran an ankò nan disjonktè a.

6. Operasyon Enstriksyon

Your OREiN flood light offers three distinct operating modes and adjustable settings for optimal performance.

6.1 Selecting Color Temperature (3CCT)

The flood light features a switch on the back of the fixture to select between three color temperatures:

Image showing the three selectable color temperatures: 2700K Warm Light, 4000K Natural White Light, and 6500K Cold White Light.

Image: Visual representation of the three adjustable light temperatures.

6.2 Understanding Lighting Modes

The flood light has a mode selector switch on the motion sensor. Choose from the following:

Diagram illustrating the three lighting modes: Manual Override, Security Mode, and Dimmable Dusk to Dawn Mode with their respective behaviors.

Image: Explanation of Manual, Security, and Dimmable Dusk to Dawn modes.

Visual comparison of the Dimmable Dusk to Dawn mode: 30% brightness in standby at night, and 100% brightness when motion is activated.

Image: Detailed illustration of the Dimmable Dusk to Dawn mode.

6.3 Motion Sensor Adjustments

The motion sensor has three adjustable knobs:

Image showing the motion sensor with labels for TIME, SENS, and LUX adjustments, indicating a 180-degree wide sensing angle and max 40ft sensing distance.

Image: Motion sensor adjustment controls and detection capabilities.

7. Antretyen

Regular maintenance ensures the longevity and optimal performance of your OREiN flood light.

Diagram showing the internal components of the flood light, highlighting the 122 enhanced LEDs, aluminum heat sink, and PC material for excellent heat dissipation.

Image: Internal structure demonstrating excellent heat dissipation.

Image showing the flood light being sprayed with water, illustrating its IP65 waterproof rating.

Image: Visual confirmation of IP65 waterproof rating.

NAN. Depanaj

If you encounter issues with your OREiN flood light, please refer to the following common problems and solutions:

PwoblèmKòz posib ak solisyon
Limyè pa limen.
  • Pa gen pouvwa: Check the circuit breaker and wall switch to ensure power is supplied to the fixture.
  • Fil elektrik ki pa kòrèk: Verify all wiring connections are secure and correctly matched (Live to Live, Neutral to Neutral, Ground to Ground).
  • Anviwònman LUX: If in D2D or Security mode, the LUX setting might be too high for current ambient light. Adjust the LUX knob to a lower setting (e.g., 20 LUX for daytime testing).
  • Obstriksyon Capteur: Ensure the motion sensor is not blocked by debris or obstructions.
Limyè rete limen kontinyèlman.
  • Anviwònman mòd: Ensure the light is not set to Manual Mode. Switch to Security or D2D mode.
  • Constant Motion: The sensor might be detecting continuous motion (e.g., tree branches, passing traffic). Adjust the SENS (sensitivity) knob to a lower setting or reposition the sensor.
  • Anviwònman TAN: The TIME setting might be set to maximum. Adjust it to a shorter duration.
Limyè a flache oubyen li tranble.
  • Koneksyon ki lach: Turn off power and check all wiring connections for looseness.
  • Fluktiyasyon pouvwa: Inconsistent power supply can cause flickering. Consult an electrician if this persists.
Capteur mouvman an pa detekte.
  • SENS Setting: The SENS (sensitivity) knob might be set too low. Increase the sensitivity.
  • Angle detèktè: The sensor might not be angled correctly to cover the desired detection area. Adjust its position.
  • Obstak: Objects like walls, large plants, or furniture might be blocking the sensor's field of view.
  • Tanperati: Extreme temperatures can sometimes affect sensor performance.

9. Garanti ak sipò

OREiN products are built with quality and durability in mind. Your OREiN 3CCT Flood Light comes with a 12-mwa garanti soti nan dat acha a.

If you have any questions, require technical assistance, or need to claim warranty service, please do not hesitate to contact our customer support team. We are committed to providing high-quality service within 24 hours.

Sipò Kliyan:

Dokiman ki gen rapò - OL27002

Preview OREIN Sensor Adjustment Instructions
A guide to adjusting the settings for OREIN motion sensor outdoor lights, covering TIME, SENS, and LUX adjustments for various lighting modes.
Preview OREiN Motion Sensor Security Light Outdoor User Manual
User manual for the OREiN Motion Sensor Security Light Outdoor, model OL27001-DW-EU. Features 24W LED floodlight, adjustable white light, IP65 waterproofing, PIR motion detection, and dusk-to-dawn functionality.
Preview Gid pou Itilizasyon ak Antretyen Limyè Zòn LED Orein
Gid konplè pou itilizasyon ak antretyen pou Limyè Zòn LED Orein, modèl SLFAL01LM416001. Gen ladan l enfòmasyon sou sekirite, depanaj, detay sou garanti, espesifikasyon, enstriksyon enstalasyon pou divès opsyon montaj, detay sou fotoselil, ak rekòmandasyon pou netwayaj.
Preview Limyè Sekirite LED OREIN ak Capteur Mouvman: Gid Enstalasyon ak Operasyon
Gid detaye pou enstalasyon, konfigirasyon ak depanaj pou Limyè Sekirite LED OREIN ak Capteur Mouvman (Modèl OL3600140). Aprann sou paramèt capteur yo, mòd fonksyònman yo, ak espesifikasyon pwodwi yo.
Preview Manyèl Enstalasyon ak Itilizatè pou Limyè Deyò OREiN Smart Motion Sensor OL36002440
Gid konplè pou enstale ak itilize Limyè Deyò ak Capteur Mouvman Entelijan OREiN yo, Modèl OL36002440. Gen ladan l konfigirasyon, ajisteman capteur, mòd, depanaj, ak enstriksyon koneksyon aplikasyon an.
Preview Manyèl Itilizatè OREIN Limyè Inondasyon Entelijan Deyò ak Capteur Mouvman OL27002546
Manyèl itilizatè pou Limyè Entelijan Deyò OREIN ak Capteur Mouvman (Modèl OL27002546). Gen ladan gid enstalasyon, paramèt capteur, deskripsyon mòd, depanaj, espesifikasyon pwodwi, ak enstriksyon koneksyon aplikasyon an.