The KKnoon MH13 Digital Insulation Resistance Tester is a high-stability and reliable instrument designed for measuring insulation resistance, AC/DC voltage, and more. It features a large LCD display with backlight, auto-ranging capabilities, and data storage, making it suitable for various electrical testing applications.

This manual provides detailed instructions for the safe and effective operation, maintenance, and troubleshooting of your MH13 tester. Please read this manual thoroughly before use to ensure proper functionality and safety.

2. Enfòmasyon sou Sekirite

WARNING: Improper use of this instrument can cause damage, shock, injury, or death. Read and understand all safety information and operating instructions before use.

  • Always ensure the device is powered off and disconnected from any circuits before connecting or disconnecting test leads.
  • Do not use the tester if it appears damaged or is operating abnormally.
  • Obsève tout kòd sekirite lokal ak nasyonal yo.
  • Avoid touching the test leads or the circuit under test during high voltage mezi.
  • Ensure proper battery installation and replacement as specified.
  • The device indicates high voltage during testing; exercise extreme caution.

3. Pwodwi souview

MH13 Digital Insulation Resistance Tester front view

Figi 3.1: Devan view of the MH13 Digital Insulation Resistance Tester, showing the LCD display, control buttons, and input terminals.

MH13 Digital Insulation Resistance Tester dimensions and button functions

Figi 3.2: Detaye view of the MH13 tester, illustrating its dimensions and the functions of each button, including TEST, HOLD, SELECT, MEM READ, and PI/DAR.

3.1 Kontni pake a

Verifye ke tout atik ki nan lis anba a yo enkli nan pakè ou a:

  • 1 x Insulation Resistance Tester (MH13)
  • 1 x Signal Shielding Wire
  • 2 x tès kondwi
  • 2 x Alligator Clips
  • 1 x depo sak
  • 1 x Manyèl Itilizatè (Angle)

4. Enstalasyon

4.1 Enstalasyon batri

The MH13 tester requires 8 x 1.5V AA batteries (not included). To install the batteries:

  1. Jwenn konpatiman batri a sou dèyè aparèy la.
  2. Sèvi ak yon tournevis pou ouvri kouvèti konpatiman batri a.
  3. Mete 8 pil AA, asire polarite kòrèk (+/-).
  4. Ranplase kouvèti lòj batri a epi an sekirite li ak vis la.

Note: The device features a low battery indication to remind you when to replace batteries.

4.2 Konekte fil tès yo

Connect the test leads to the appropriate input terminals on the tester. For most measurements, the red lead connects to the "LINE" terminal and the black lead to the "EARTH" terminal. For specific measurements like AC/DC voltage, refer to the relevant operating instructions.

5. Operasyon Enstriksyon

5.1 Power On/Off

Peze epi kenbe la POUVWA bouton pou 2 segonn pou limen oswa etenn aparèy la.

5.2 Mezi rezistans izolasyon

This function is used to measure the insulation resistance of various electrical equipment and insulating materials.

MH13 Digital Insulation Resistance Tester measuring insulation resistance on a motor

Figure 5.1: The MH13 tester connected to a motor for insulation resistance measurement, demonstrating the high voltage output capability.

  1. Ensure the circuit under test is de-energized and safely isolated.
  2. Connect the test leads to the two ends of the component or circuit you wish to test.
  3. Chwazi vol pwodiksyon an vletage (250V, 500V, 1000V, 2000V, or 2500V) using the Up/Down arrow buttons.
  4. Peze a TÈS button to initiate the measurement. The red light on the TEST button will illuminate.
  5. The insulation resistance value will be displayed on the LCD.
  6. After the measurement, the device will automatically discharge the circuit. Do not touch the test leads until the discharge is complete.

Note: The device has a high voltage indication to alert users during testing.

5.3 AC/DC Voltage Mezi

The MH13 can also measure AC and DC voltages within the range of 10V to 600V.

MH13 Digital Insulation Resistance Tester measuring AC and DC voltage

Figure 5.2: Illustration of how to connect the test leads for measuring AC voltage (left) and DC voltage (right) using the MH13 tester.

  1. In the standby interface, short press the CHWAZI button to enter the AC voltage function. Press it again to switch to the DC voltage fonksyon.
  2. Adjust the gear to the ACV or DCV voltage gear for measurement.
  3. Insert the test lead plug into the appropriate terminals (AC and G for AC, DC and G for DC).
  4. Vol latage reading will be displayed on the LCD.

5.4 Absorption Ratio (DAR) and Polarization Index (PI)

The MH13 supports the calculation of Absorption Ratio (DAR) and Polarization Index (PI), which are crucial for assessing the quality of insulation.

MH13 Digital Insulation Resistance Tester Absorption Ratio (DAR) explanation

Figure 5.3: Explanation of Absorption Ratio (DAR) measurement, showing 15-second and 1-minute insulation resistance readings and the calculation formula.

MH13 Digital Insulation Resistance Tester Polarization Index (PI) explanation

Figure 5.4: Explanation of Polarization Index (PI) measurement, showing 1-minute and 10-minute insulation resistance readings and the calculation formula.

To perform DAR/PI tests:

  1. Set up for insulation resistance measurement as described in Section 5.2.
  2. Peze a PI/DAR button to initiate the test. The device will automatically compute and display the DAR and PI values based on timed measurements.
  3. Refer to the judgment standards provided in the product documentation for interpreting the results.

5.5 Data Hold and Storage

The MH13 can store up to 100 sets of measured insulation resistance values.

MH13 Digital Insulation Resistance Tester data storage display

Figure 5.5: The display showing multiple stored data sets, indicating the device's 100-set data storage capability.

  • Done kenbe: During a measurement, single press the KENBE bouton an pou bloke lekti aktyèl la sou ekran an. Peze ankò pou lage.
  • Depo done: Apre yon mezi, peze bouton an MEM READ button to save the data.
  • View Stored Data: Peze a MEM READ button to enter data browsing mode. Use the Up/Down arrow buttons to navigate through stored data groups.
  • Delete Stored Data: Refer to the full manual for instructions on deleting stored data, if applicable.

5.6 Signal Shielding for Measurement Accuracy

To minimize errors caused by "word jumping" phenomena in measurements, especially with sensitive insulation tests, utilize the signal shielding wire.

MH13 Digital Insulation Resistance Tester with signal shielding wire connected

Figure 5.6: The MH13 tester connected with a signal shielding wire, demonstrating how to reduce measurement errors by connecting the inner jack to the cable shell.

When a serious word jumping phenomenon occurs, insert the signal shielding wire's inner jack into the "G" (Guard) terminal. Connect the other end of the shielding wire to the cable shell or the inner insulation of the core to eliminate the error.

6. Antretyen

6.1 Netwayaj

Wipe the device with a dry, soft cloth. Do not use abrasive cleaners or solvents. Ensure no liquids enter the device.

6.2 Depo

When not in use for extended periods, remove the batteries to prevent leakage. Store the tester in its provided storage bag in a cool, dry place, away from direct sunlight and extreme temperatures.

MH13 Digital Insulation Resistance Tester with anti-drop silicone case

Figure 6.1: The MH13 tester protected by its anti-drop silicone case, highlighting its durable design for outdoor use and protection against damage.

The device is designed with a durable anti-drop silicone case, offering protection against accidental drops and impacts.

NAN. Depanaj

PwoblèmKòz posibSolisyon
Aparèy pa limen.Pil ki fèb oswa ki mouri; move enstalasyon pil.Ranplase pil yo ak nouvo; asire polarite ki kòrèk la.
"OL" or "Out of Range" displayed during measurement.Resistance is higher than the maximum range; open circuit.Verify circuit continuity; ensure proper connection of test leads.
Lekti ki pa egzak oswa ki varye.Poor test lead connection; external interference; dirty terminals; "word jumping" phenomenon.Ensure secure connections; use signal shielding wire; clean terminals; move away from strong electromagnetic fields.
Segondè voltage warning remains after test.Sikwi a pa dechaje nèt.Wait for automatic discharge to complete. Do not touch leads until warning clears.

8. Espesifikasyon

ParamètValè
Sòti Voltage250V / 500V / 1000V / 2000V / 2500V
Ranje rezistans izolasyon1MΩ ~ 200GΩ
AC Voltage Range10V ~ 600V
DC Voltage Range10V ~ 600V
Maks. Montre2000 konte
Depo Done100 ansanm
RangeRanje oto
Tanperati Fonksyònman0-35 °C
Tanperati Depo-10 ~ 50 ° C
Pwovizyon pou pouvwa8 * 1.5V AA battery (NOT included)
Gwosè Atik180 * 140 * 70mm / 7.09 * 5.51 * 2.76in
Pwa atik640g / 22.58oz

9. Garanti ak sipò

For warranty information, technical support, or service inquiries, please refer to the official KKnoon website or contact their customer service directly. Details are typically provided in the full product manual or on the manufacturer's official channels.

Dokiman ki gen rapò - MH13

Preview ANENG MH13 Insulation Resistance Tester Manual
Comprehensive user manual for the ANENG MH13 series insulation resistance tester. Covers safety guidelines, product features, technical specifications, operational procedures for insulation resistance, AC/DC voltage testing, data management, and battery replacement. Designed for electrical maintenance, repair, and verification.
Preview ANENG 1000V/2500V/5000V Series Insulation Resistance Tester User Manual
Comprehensive user manual for the ANENG 1000V, 2500V, and 5000V series Insulation Resistance Testers, covering safety, operation, technical specifications, and measurement procedures for electrical equipment.
Preview ANENG MH13 Insulation Resistance Tester - Technical Specifications and Features
Detailed specifications, features, and measurement explanations for the ANENG MH13 Insulation Resistance Tester, including Polarization Index (PI) and Absorption Ratio (DAR) testing. Covers AC/DC voltage measurement, product accessories, and operational guidance.
Preview Tableau de Correspondance FACOM : Anciennes et Nouvelles Références Outils
Gade tablo korespondans FACOM pou jwenn nouvo referans ou zouti FACOM à partir des anciennes références. Sa gid referans de nombreux produits FACOM.