The Fluke 1507 Digital Megohmmeter Insulation Resistance Tester is a robust and reliable instrument designed for comprehensive insulation testing in industrial and electrical environments. This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of your Fluke 1507 tester.

Key features include multiple insulation test voltages, automatic calculation of Polarization Index (PI) and Dielectric Absorption Ratio (DAR), a Compare (Pass/Fail) function for repetitive testing, and live circuit detection for enhanced safety.

2. Enfòmasyon sou Sekirite

WARNING: Always read and understand all safety information before operating the Fluke 1507 tester. Failure to do so may result in serious injury or death.

3. Components and Included Accessories

The Fluke 1507 Insulation Resistance Tester package typically includes the following items:

Fluke 1507 Insulation Tester with included accessories
Figure 3.1: The Fluke 1507 Insulation Tester shown with its standard included accessories, including test leads, probes, alligator clips, and the remote probe.

4. Enstalasyon

4.1. Enstalasyon batri

The Fluke 1507 requires four AA alkaline batteries for operation. These are typically included with the unit. To install or replace batteries:

  1. Ensure the tester is turned OFF.
  2. Jwenn konpatiman batri a sou dèyè aparèy la.
  3. Sèvi ak yon tournevis pou ouvri kouvèti konpatiman batri a.
  4. Insert the four AA batteries, observing the correct polarity as indicated inside the compartment.
  5. Ranplase kouvèti lòj batri a epi an sekirite li ak vis la.

4.2. Konekte fil tès yo

Connect the test leads to the appropriate input jacks on the tester. For insulation resistance measurements, use the 'V Ω' and 'COM' jacks. Ensure connections are secure before proceeding with any tests.

5. Operasyon Enstriksyon

5.1. Powering On / Off

To power on the Fluke 1507, rotate the rotary switch from the 'OFF' position to any desired measurement function. The large, backlit display will illuminate. To power off, rotate the switch back to 'OFF'. The unit also features an auto-power off function to conserve battery life.

Devan view of the Fluke 1507 Insulation Tester display and controls
Figure 5.1: The front panel of the Fluke 1507, showing the display, rotary switch, and function buttons.

5.2. Chwazi Volim Tès latages

The Fluke 1507 offers multiple insulation test voltages. Rotate the main rotary switch to the 'INSULATION' section. Then, use the dedicated voltage selection buttons (50 V, 100 V, 250 V, 500 V, 1000 V) to choose the appropriate test voltage pou aplikasyon w lan.

5.3. Performing Insulation Tests

Once the desired test voltage is selected and test leads are connected to the circuit under test:

  1. Peze epi kenbe la TÈS button to initiate the insulation test. The display will show the measured insulation resistance.
  2. For hands-free operation during repetitive tests, utilize the remote test probe.
  3. The live circuit detection feature will prevent a test if voltage exceeds 30V, indicated by a warning on the display.
Fluke 1507 Insulation Tester held in a gloved hand during operation
Figure 5.2: The Fluke 1507 being held by a technician, demonstrating its compact and ergonomic design for field use.
Technician using Fluke 1507 to test an industrial motor
Figure 5.3: A technician performing an insulation test on an industrial motor using the Fluke 1507, highlighting its application in preventative maintenance.

5.4. Compare (Pass/Fail) Function

The Compare (Pass/Fail) function simplifies repetitive testing by allowing you to set a pass/fail threshold. Refer to the on-screen prompts and the user interface for setting this function. The tester will then indicate whether the measured resistance meets the predefined criteria.

5.5. Endèks polarizasyon (PI) ak rapò absòpsyon Dielectric (DAR)

The Fluke 1507 automatically calculates Polarization Index (PI) and Dielectric Absorption Ratio (DAR), saving time and ensuring accurate assessment of insulation condition. These functions are typically accessed via dedicated buttons on the front panel.

Technician using Fluke 1507 with magnetic hanging system for overhead work
Figure 5.4: A technician utilizing the optional magnetic hanging system with the Fluke 1507, allowing for hands-free operation during overhead electrical work.

6. Antretyen

6.1. Netwayaj

To clean the exterior of the tester, use a damp cloth and a mild detergent. Do not use abrasive cleaners or solvents. Ensure the unit is completely dry before storage or next use.

6.2. Ranplasman batri

Replace batteries when the low battery indicator appears on the display. Refer to Section 4.1 for detailed battery installation instructions. Always use fresh alkaline batteries.

6.3. Kalibrasyon

For optimal performance and accuracy, periodic calibration by an authorized service center is recommended. Refer to your warranty information or contact Fluke support for calibration schedules and services.

NAN. Depanaj

This section provides solutions to common issues you might encounter with your Fluke 1507 tester.

PwoblèmKòz posibSolisyon
Tèstè a pa limen.Pil ki mouri oswa ki mal enstale.Tcheke polarite pil yo epi ranplase yo ak pil AA nèf.
Insulation test does not start.Live voltage detected on the circuit.Ensure the circuit is de-energized or voltage is below 30V. The tester will not perform an insulation test if live voltage is present for safety.
Lekti ki pa kòrèk.Damaged test leads or improper connection.Inspect test leads for damage. Ensure leads are securely connected to the tester and the circuit.
Ekran an fèb oswa li ap tranble.Batri ki ba.Ranplase pil.

8. Espesifikasyon

SpesifikasyonValè
MakFluke
Nimewo Modèl1507
Sous pouvwaMache ak pil (4 pil AA)
Tès izolasyon Voltages50 V, 100 V, 250 V, 500 V, 1000 V
Min. Operating Voltage50 Vòlt (DC)
Voltage Rating600 Volts
Presizyon Mezi+/-0.5%
Pwa atik2.2 liv (1 kilogram)
Dimansyon pwodwi (L x W x H)11.77 x 15.2 x 3.07 pous
MateryèlPlastik
KoulèJòn
KonfòmiteEN 61010-1, CAT IV 600 V
Konpozan ki enkliRemote probe, test leads, test probes, alligator clips

9. Garanti ak sipò

9.1. Enfòmasyon sou Garanti

The Fluke 1507 Digital Megohmmeter Insulation Resistance Tester comes with a 1-Year warranty. Please retain your proof of purchase for warranty claims. The warranty covers defects in materials and workmanship under normal use.

9.2. Sipò pou Kliyan

For technical assistance, service, or to inquire about calibration services, please visit the official Fluke website or contact their customer support. You can also refer to the comprehensive User Manual (PDF) available online for more detailed information:

Dokiman ki gen rapò - 1507

Preview Fluke 1535/1537/1537-II Insulation Tester User Manual
Comprehensive user manual for Fluke 1535, 1537, and 1537-II Insulation Testers, covering features, operation, testing procedures, maintenance, and specifications.
Preview Fluke 1550C/1555 Insulation Tester Users Manual
User manual for the Fluke 1550C and 1555 Insulation Testers, detailing features, operation, measurements, maintenance, and specifications.
Preview Fluke SMFT-1000: Voc and Operational Current Testing Guide for PV Systems
This application note from Fluke Corporation details how to perform Voc (Open Circuit Voltage) and Ioperational (Operational Current) tests on photovoltaic (PV) modules and strings using the Fluke SMFT-1000 tester, adhering to IEC 62446-1 standards. It provides step-by-step instructions and explains the interpretation of test results for ensuring PV system performance and identifying wiring faults.
Preview Fluke 1507/1503 Insulation Testers User Manual
Comprehensive user manual for Fluke 1507 and 1503 Insulation Testers, detailing operation, safety precautions, measurement procedures, technical specifications, and maintenance.
Preview Gid Referans Rapid pou Analizè PV Miltifonksyon Fluke SMFT-1000 la
A quick reference guide for the Fluke SMFT-1000 Multifunction PV Analyzer, providing step-by-step instructions for essential solar photovoltaic system tests including loop resistance, polarity, Voc/Isc, insulation resistance, and I-V curve tracing.
Preview Twous Inite Pwouve Fluke T5-1000 / PRV240: Done Teknik ak Enfòmasyon sou Kòmand
Done teknik konplè ak enfòmasyon sou kòmann pou tès elektrik Fluke T5-1000 la ak twous inite prèv PRV240 la, ki detaye espesifikasyon pwodwi yo, konpozan yo, ak enfòmasyon pou kontakte Fluke Corporation.