1. Entwodiksyon
The Fluke 1507 Digital Megohmmeter Insulation Resistance Tester is a robust and reliable instrument designed for comprehensive insulation testing in industrial and electrical environments. This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of your Fluke 1507 tester.
Key features include multiple insulation test voltages, automatic calculation of Polarization Index (PI) and Dielectric Absorption Ratio (DAR), a Compare (Pass/Fail) function for repetitive testing, and live circuit detection for enhanced safety.
2. Enfòmasyon sou Sekirite
WARNING: Always read and understand all safety information before operating the Fluke 1507 tester. Failure to do so may result in serious injury or death.
- Deteksyon Awondisman Live: The tester is equipped with live circuit detection, which prevents insulation tests if a voltage greater than 30 Volts is detected. This feature is crucial for user protection.
- Auto-Discharge: The 1507 provides auto-discharge of capacitive voltage for added user protection after testing.
- Kategori Mezi: This instrument complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 No. 61010-1-04, and IEC/EN 61010-1 2nd edition for Measurement Category IV 600 V (CAT IV). Always use the tester within its specified measurement category.
- Itilizasyon apwopriye: Use only the test leads and accessories supplied or approved by Fluke. Inspect test leads for damage before each use.
- Kondisyon anviwònman: Do not use the tester in wet or explosive environments. Ensure the operating area is dry and well-ventilated.
3. Components and Included Accessories
The Fluke 1507 Insulation Resistance Tester package typically includes the following items:
- Fluke 1507 Insulation Resistance Tester Unit
- Fil tès TL224 yo
- TP74 Test Probes
- Klip Kayiman
- Holster
- Sond Remote
- Four AA Batteries (pre-installed or included separately)

4. Enstalasyon
4.1. Enstalasyon batri
The Fluke 1507 requires four AA alkaline batteries for operation. These are typically included with the unit. To install or replace batteries:
- Ensure the tester is turned OFF.
- Jwenn konpatiman batri a sou dèyè aparèy la.
- Sèvi ak yon tournevis pou ouvri kouvèti konpatiman batri a.
- Insert the four AA batteries, observing the correct polarity as indicated inside the compartment.
- Ranplase kouvèti lòj batri a epi an sekirite li ak vis la.
4.2. Konekte fil tès yo
Connect the test leads to the appropriate input jacks on the tester. For insulation resistance measurements, use the 'V Ω' and 'COM' jacks. Ensure connections are secure before proceeding with any tests.
5. Operasyon Enstriksyon
5.1. Powering On / Off
To power on the Fluke 1507, rotate the rotary switch from the 'OFF' position to any desired measurement function. The large, backlit display will illuminate. To power off, rotate the switch back to 'OFF'. The unit also features an auto-power off function to conserve battery life.

5.2. Chwazi Volim Tès latages
The Fluke 1507 offers multiple insulation test voltages. Rotate the main rotary switch to the 'INSULATION' section. Then, use the dedicated voltage selection buttons (50 V, 100 V, 250 V, 500 V, 1000 V) to choose the appropriate test voltage pou aplikasyon w lan.
5.3. Performing Insulation Tests
Once the desired test voltage is selected and test leads are connected to the circuit under test:
- Peze epi kenbe la TÈS button to initiate the insulation test. The display will show the measured insulation resistance.
- For hands-free operation during repetitive tests, utilize the remote test probe.
- The live circuit detection feature will prevent a test if voltage exceeds 30V, indicated by a warning on the display.


5.4. Compare (Pass/Fail) Function
The Compare (Pass/Fail) function simplifies repetitive testing by allowing you to set a pass/fail threshold. Refer to the on-screen prompts and the user interface for setting this function. The tester will then indicate whether the measured resistance meets the predefined criteria.
5.5. Endèks polarizasyon (PI) ak rapò absòpsyon Dielectric (DAR)
The Fluke 1507 automatically calculates Polarization Index (PI) and Dielectric Absorption Ratio (DAR), saving time and ensuring accurate assessment of insulation condition. These functions are typically accessed via dedicated buttons on the front panel.

6. Antretyen
6.1. Netwayaj
To clean the exterior of the tester, use a damp cloth and a mild detergent. Do not use abrasive cleaners or solvents. Ensure the unit is completely dry before storage or next use.
6.2. Ranplasman batri
Replace batteries when the low battery indicator appears on the display. Refer to Section 4.1 for detailed battery installation instructions. Always use fresh alkaline batteries.
6.3. Kalibrasyon
For optimal performance and accuracy, periodic calibration by an authorized service center is recommended. Refer to your warranty information or contact Fluke support for calibration schedules and services.
NAN. Depanaj
This section provides solutions to common issues you might encounter with your Fluke 1507 tester.
| Pwoblèm | Kòz posib | Solisyon |
|---|---|---|
| Tèstè a pa limen. | Pil ki mouri oswa ki mal enstale. | Tcheke polarite pil yo epi ranplase yo ak pil AA nèf. |
| Insulation test does not start. | Live voltage detected on the circuit. | Ensure the circuit is de-energized or voltage is below 30V. The tester will not perform an insulation test if live voltage is present for safety. |
| Lekti ki pa kòrèk. | Damaged test leads or improper connection. | Inspect test leads for damage. Ensure leads are securely connected to the tester and the circuit. |
| Ekran an fèb oswa li ap tranble. | Batri ki ba. | Ranplase pil. |
8. Espesifikasyon
| Spesifikasyon | Valè |
|---|---|
| Mak | Fluke |
| Nimewo Modèl | 1507 |
| Sous pouvwa | Mache ak pil (4 pil AA) |
| Tès izolasyon Voltages | 50 V, 100 V, 250 V, 500 V, 1000 V |
| Min. Operating Voltage | 50 Vòlt (DC) |
| Voltage Rating | 600 Volts |
| Presizyon Mezi | +/-0.5% |
| Pwa atik | 2.2 liv (1 kilogram) |
| Dimansyon pwodwi (L x W x H) | 11.77 x 15.2 x 3.07 pous |
| Materyèl | Plastik |
| Koulè | Jòn |
| Konfòmite | EN 61010-1, CAT IV 600 V |
| Konpozan ki enkli | Remote probe, test leads, test probes, alligator clips |
9. Garanti ak sipò
9.1. Enfòmasyon sou Garanti
The Fluke 1507 Digital Megohmmeter Insulation Resistance Tester comes with a 1-Year warranty. Please retain your proof of purchase for warranty claims. The warranty covers defects in materials and workmanship under normal use.
9.2. Sipò pou Kliyan
For technical assistance, service, or to inquire about calibration services, please visit the official Fluke website or contact their customer support. You can also refer to the comprehensive User Manual (PDF) available online for more detailed information: