N1 Critical N1C.L1500

N1 Critical N1C.L1500 1500VA/1350W Lithium Ion Rack/Tower UPS User Manual

Model: N1C.L1500

1. Entwodiksyon

The N1 Critical N1C.L1500 is a high-performance 1500VA/1350W Uninterruptible Power Supply (UPS) designed to provide reliable power protection for critical electronic equipment. Featuring advanced Lithium-Ion (LiFePO4) battery technology, this UPS offers extended battery life, higher power density, and improved thermal performance compared to traditional VRLA battery systems. It supports both rackmount and tower configurations, making it versatile for various IT environments.

2. Enstriksyon Sekirite

Please read and follow all safety instructions carefully before installing, operating, or servicing the UPS. Failure to comply with these instructions may result in electric shock, fire, or serious injury.

3. Pake kontni

Verifye ke tout atik yo prezan lè w ap debale yo:

4. Pwodwi souview

4.1 Panèl devan

The front panel features the LCD display and control buttons for monitoring and configuring the UPS.

N1 Critical N1C.L1500 UPS Front View

Figi 4.1: Devan view of the N1 Critical N1C.L1500 UPS, showing the integrated LCD display and control buttons.

N1 Critical N1C.L1500 UPS LCD Display

Figure 4.2: Close-up of the N1 Critical N1C.L1500 UPS LCD display, indicating input voltage, battery status, and operational modes.

4.2 Panèl dèyè

The rear panel provides all necessary connections for input power, protected equipment, and communication interfaces.

N1 Critical N1C.L1500 UPS Rear View with Outlets and Ports

Figi 4.3: Dèyè view of the N1 Critical N1C.L1500 UPS, showing six NEMA 5-15R outlets, AC input, circuit protector, USB port, EPO port, and an intelligent slot.

5. Enstalasyon

5.1 Plasman

The N1C.L1500 UPS can be installed in either a rackmount or tower configuration.

Ensure the installation location is well-ventilated, free from excessive heat or moisture, and has stable ambient temperatures.

5.2 Konekte sou pouvwa

  1. Connect the supplied input power cord to the AC Input port on the rear panel of the UPS.
  2. Plug the other end of the input power cord into a grounded 120V AC wall outlet.

5.3 Konekte Ekipman

  1. Ensure all equipment to be connected to the UPS is turned off.
  2. Plug your critical equipment (computers, servers, network devices) into the NEMA 5-15R outlets on the rear panel of the UPS.
  3. Do not connect surge suppressors or power strips to the UPS outlets, as this may overload the UPS.

5.4 Premye demaraj

  1. After connecting the UPS to utility power and your equipment, press and hold the power button on the front panel for a few seconds until the UPS powers on.
  2. The LCD display will illuminate, and the UPS will perform a self-test.
  3. Once the self-test is complete, the UPS will enter normal operating mode, providing conditioned power to your connected devices.

6. Operasyon Enstriksyon

6.1 Power On/Off

6.2 Konprann Ekran LCD a

The LCD display provides real-time information about the UPS status, including input/output voltage, battery charge level, load percentage, and various operational modes or warnings. Refer to Figure 4.2 for a visual reference.

6.3 Operasyon Batri Sekou

Pandan yon pouvwa outage oswa volim siyifikatiftage fluctuation, the UPS will automatically switch to battery power, providing continuous power to connected equipment. An audible alarm may sound, and the display will indicate battery mode. The duration of backup power depends on the connected load and battery charge level.

6.4 Karakteristik Kominikasyon

7. Antretyen

7.1 Swen Batri

The N1C.L1500 utilizes Lithium-Ion (LiFePO4) batteries, which offer a significantly longer lifespan (10-15 years) and better thermal tolerance compared to traditional lead-acid batteries. These batteries are not user-replaceable. For battery service or replacement, contact qualified service personnel.

7.2 Netwayaj

Periodically clean the exterior of the UPS with a soft, dry cloth. Ensure ventilation openings are free from dust and debris to maintain proper airflow. Do not use liquid or aerosol cleaners.

7.3 Depo

If storing the UPS for an extended period, ensure it is fully charged before storage. Store in a cool, dry environment. Recharge the UPS every 3-6 months to maintain battery health.

NAN. Depanaj

This section provides solutions to common issues you may encounter with the UPS.

PwoblèmKòz posibSolisyon
UPS la pa limenNo AC input power; UPS not fully charged; Power button not pressed correctly.Check AC power connection and outlet; Allow UPS to charge for several hours; Press and hold power button firmly.
UPS is in battery mode frequentlyUnstable utility power; Sensitivity setting too high.Check utility power quality; Adjust UPS sensitivity setting via software (if available).
Avètisman SurchargeConnected equipment exceeds UPS capacity.Disconnect non-essential equipment; Reduce the total load to within UPS capacity.
Battery fault indicatorPwoblèm batri entèn.Contact N1 Critical support for assistance. Do not attempt to replace the battery yourself.

9. Espesifikasyon

Technical specifications for the N1 Critical N1C.L1500 UPS:

10. Garanti ak sipò

For warranty information, technical support, or service inquiries, please refer to the official N1 Critical website or contact their customer service department. Keep your purchase receipt for warranty validation.