MAXWELL 2MX18AXVJU+CTX09AXVJU+CTX09AXVJU

Daikin 2-Zone CIRRA Series Mini Split Air Conditioner Heat Pump System

Model: 2MX18AXVJU+CTX09AXVJU+CTX09AXVJU

Mak: MAXWELL

1. Pwodwi souview

The Daikin 2-Zone CIRRA Series Mini Split Air Conditioner Heat Pump System is designed for multi-room applications, providing individual comfort in a space-saving design. This system allows connection of two wall-mounted indoor units to a single outdoor unit, offering a compact and efficient solution for various spaces. It features advanced technologies for enhanced performance and durability.

Daikin 2-Zone Mini Split System Components

Figure 1.1: Complete Daikin 2-Zone Mini Split System, showing two indoor units, one outdoor condenser, two remote controls, two pre-flared line sets, two communication cables, and a wall mounting bracket kit.

Karakteristik kle:

Daikin 2-Zone System Components Diagram

Figure 1.2: Diagram illustrating the main components included in your system: two wall-mount indoor units, two remote controls, two pre-flared line sets, two communication cables, an outdoor unit bracket, and an R410A pre-charged outdoor condenser.

2. Enstalasyon ak Enstalasyon

Proper installation is crucial for optimal performance and longevity of your Daikin Mini Split System. It is highly recommended that installation be performed by a qualified HVAC professional.

Eleman ki enkli:

Maxwell 15 ft. Installation Kit

Figure 2.1: The Maxwell 15 ft. installation kit, which includes pre-flared refrigerant lines and electrical communication cables, essential for connecting the indoor and outdoor units.

Wall Mounting Bracket for Outdoor Unit

Figure 2.2: The robust wall mounting bracket and associated hardware, designed to securely support the outdoor condenser unit.

Installation Steps (Summary - Refer to full installation manual for detailed instructions):

  1. Chwazi Kote: Choose appropriate locations for indoor units (wall-mounted) and the outdoor condenser, ensuring proper airflow and drainage.
  2. Mount Indoor Units: Securely attach the mounting plates to the wall and install the indoor units.
  3. Install Outdoor Condenser: Mount the outdoor unit using the provided wall bracket or a suitable ground-level pad.
  4. Konekte liy frijidè yo: Carefully connect the pre-flared refrigerant lines between the indoor and outdoor units. Ensure proper torque to prevent leaks.
  5. Fil elektrik: Connect the communication cables and power supply according to local electrical codes and the wiring diagram in the detailed manual.
  6. Aspirasyon ak Chaj: Evacuate the refrigerant lines to remove air and moisture. The system comes pre-charged, but additional refrigerant may be needed depending on line length.
  7. Operasyon tès: Power on the system and test all modes (cooling, heating, fan) to ensure correct operation.

3. Operasyon Enstriksyon

Your Daikin Mini Split System is controlled via the included wireless remote controls, one for each indoor unit. Familiarize yourself with the remote's functions for optimal comfort.

Kontwòl remote Daikin Mini Split

Figure 3.1: The wireless remote control for the Daikin Mini Split indoor unit, featuring buttons for power, temperature adjustment, mode selection (Cool, Heat, Fan), and special functions like Eco+ and Sleep.

Operasyon debaz:

Fonksyon avanse:

4. Antretyen

Regular maintenance ensures efficient and reliable operation of your Daikin Mini Split System. Always disconnect power before performing any maintenance.

Indoor Unit Maintenance:

Antretyen Inite Eksteryè a:

NAN. Depanaj

This section provides solutions for common issues. For complex problems, contact a qualified technician.

PwoblèmKòz posibSolisyon
Inite pa limenNo power; Remote control batteries low; Circuit breaker tripped.Check power supply; Replace remote batteries; Reset circuit breaker.
Refwadisman/chofaj ensifizanDirty air filters; Blocked outdoor unit; Low refrigerant; Incorrect mode setting.Clean filters; Clear obstructions; Contact technician for refrigerant check; Verify mode.
Bri etranjPyès ki lach; Vantilatè bloke; Bri koule frijidè (nòmal).Check for loose parts; Remove obstructions; If noise persists, contact technician.
Flit dlo nan inite andedan anClogged drain line; Improper installation.Clear drain line; Contact professional for inspection.

6. Espesifikasyon

Detailed technical specifications for the Daikin 2-Zone CIRRA Series Mini Split System.

Daikin Dual-Zone System Specification Diagram

Figure 6.1: Detailed diagram showing dimensions of both indoor and outdoor units, along with key specifications such as power supply, operating ranges, rated capacity, piping connections, refrigerant type, and pre-charged piping length.

SpesifikasyonValè
Non makMAXWELL
Enfòmasyon sou modèl2MX18AXVJU+CTX09AXVJU+CTX09AXVJU
Pwa atik145 liv
Dimansyon pwodwi9 x 31 x 11 pous (Inite Anndan)
Efikasite (SEER)17.0
Kapasite1.5 Tons (Total)
Nivo bri51 dB (Outdoor)
Kalite enstalasyonSistèm Split
Karakteristik espesyalAnti-Corrosion Treatment, Automatic Defrosting, Eco+ Mode, Quick Warming Function
Voltage230 Volts
Wattage5125 wat
Kouvèti zòn etaj800 pye kare
Ranje Refwadisman Operasyonèl50° - 115°F
Ranje Chofaj Operasyonèl5° - 65°F
Heating Seasonal Performance Factor (HSPF)9.00
Energy Guide Label for Daikin 2MX18AXVJU

Figure 6.2: The official Energy Guide label for the Daikin 2MX18AXVJU model, indicating a Cooling Efficiency Rating (SEER) of 17.00 and a Heating Efficiency Rating (HSPF) of 9.00.

7. Garanti ak sipò

Enfòmasyon sou garanti:

This Daikin Mini Split System comes with a 10-Year Daikin Manufacturer Warranty. Please retain your proof of purchase for warranty claims. For specific warranty terms and conditions, refer to the documentation provided with your product or contact Daikin customer service.

Sipò Kliyan:

For technical assistance, troubleshooting beyond this manual, or warranty service, please contact MAXWELL customer support. You can typically find contact information on the product packaging, the official MAXWELL websit la, oubyen atravè pwen acha ou a.

When contacting support, please have your product model number (2MX18AXVJU+CTX09AXVJU+CTX09AXVJU) and serial number ready to expedite the process.

Dokiman ki gen rapò - 2MX18AXVJU+CTX09AXVJU+CTX09AXVJU

Preview Enstriksyon Enstalasyon Sipò Maxwell WAFR24 la
Gid enstalasyon detaye pou sipò Maxwell WAFR24 ki monte sou twati a ak yon pant reglabl, ki gen ladan yon lis akseswa ak enstriksyon asanblaj etap pa etap.
Preview RC12-HD Windlass Vètikal - Manyèl Enstalasyon, Operasyon, ak Antretyen
Manyèl konplè pou Maxwell RC12-HD Vertical Windlass la, ki kouvri enstalasyon, operasyon, antretyen, espesifikasyon, depanaj, ak pyès rezèv. Gen ladan l dyagram detaye ak chema fil elektrik.
Preview CFT 100 Digital Timer and Counter (2-in-1) User Manual
User manual for the CFT 100 digital timer and counter, covering features, panel description, ordering information, dimensions, wiring, parameter settings, and RS-485 communication protocols.
Preview Maxwell 25700 Automatic Digital Multimeter User Manual
User manual for the Maxwell 25700 Automatic Digital Multimeter, featuring non-contact voltage detection, comprehensive measurement functions, and safety guidelines.
Preview Maxwell MW-1441 W Machin Krèm Glase - Manyèl Itilizatè ak Enstriksyon
Manyèl itilizatè ofisyèl ak enstriksyon pou machin krèm glase Maxwell MW-1441 W la. Aprann kijan pou rasanble, itilize, netwaye epi depanaj aparèy ou an. Gen ladan l resèt ak espesifikasyon teknik.
Preview Manyèl Itilizatè Miltimèt Dijital MAXWELL MX 25 313
Manyèl itilizatè konplè pou miltimèt dijital MAXWELL MX 25 313 ​​la, ki kouvri karakteristik, espesifikasyon teknik, enfòmasyon sekirite, ak enstriksyon operasyon pou yon mezi volim egzat.tage, kouran, rezistans, ak plis mezi.