1. Pwodwi souview
The Coby CBPAC815 is a versatile 3-in-1 portable air conditioner designed to provide efficient cooling, effective dehumidification, and powerful fan functions for various indoor spaces. With a robust cooling capacity of 12,000 BTU (ASHRAE 128) and 8,150 BTU (SACC/CEC), this unit is capable of cooling rooms up to 550 square feet. It features user-friendly electronic controls with a clear LED display and comes with a full-function remote control for convenient operation. Its compact design, coupled with built-in handles and 360-degree casters, ensures easy mobility from room to room.
Karakteristik kle:
- Fonksyonalite 3-an-1: Air Conditioner, Dehumidifier, and Fan modes.
- Kapasite refwadisman: 12,000 BTU (ASHRAE 128) / 8,150 BTU (SACC/CEC) for spaces up to 550 sq. ft.
- Plizyè vitès: 3 cooling speeds and 3 fan speeds for customized comfort.
- Kontwòl Elektwonik: Intuitive LED display for easy setting adjustments.
- Kontwòl Remote: Full-function remote for convenient operation from a distance.
- Revèy 24 èdtan: Pwograme aparèy la pou l limen oswa etenn otomatikman.
- Evaporasyon Dlo Otomatik: Reduces the need for manual drainage.
- Auto Air Swing: Ensures even air distribution.
- Fasil Mobilite: Equipped with four 360-degree casters and two side handles.
- Filtre ou ka lave: Removable and reusable filter for easy maintenance.
Vizyèl pwodwi yo:



Videyo pwodwi ofisyèl la:
Prezantasyon videyo pwodwi ofisyèl laasing the Coby CBPAC815 Portable Air Conditioner's features and benefits.
2. Enfòmasyon sou Sekirite
Please read all safety instructions carefully before operating the unit to prevent injury or damage. Keep this manual for future reference.
- Always plug the unit into a grounded 3-prong outlet. Do not use extension cords or adapter plugs.
- Pa sèvi ak aparèy la si kòd kouran an oswa ploge a domaje. Si kòd la domaje, manifakti a oswa yon ajan sèvis kalifye dwe ranplase li.
- Ensure the unit is placed on a stable, level surface to prevent tipping and water leakage.
- Do not block the air intake or exhaust vents. Maintain at least 20 inches (50 cm) of clearance around the unit for proper airflow.
- Debranche aparèy la nan priz kouran an anvan ou netwaye li, anvan ou fè antretyen, oswa lè w pa ap itilize li.
- Pa mete dwèt ou oswa objè etranje nan ouvèti lè yo.
- This appliance uses R-32 refrigerant. Handle with care and ensure proper ventilation during installation and servicing.
- Kenbe aparèy la lwen sous chalè, limyè solèy dirèk, ak materyèl ki ka pran dife.
- Supervise children and individuals with reduced physical, sensory, or mental capabilities when the appliance is in use.
3. Enstalasyon
Debake:
- Ak anpil atansyon retire inite a nan anbalaj li yo.
- Remove all packing materials, including foam and tape.
- Check for any shipping damage. If the unit is damaged, do not operate it and contact customer support.
Plasman:
- Place the portable air conditioner on a firm, level surface in a location that allows for proper ventilation.
- Ensure there is at least 20 inches (50 cm) of space around the unit for optimal performance.
- Position the unit near a window or sliding door for easy installation of the exhaust hose.
- The unit is equipped with 360-degree casters and side handles for easy movement.
Enstalasyon twous fenèt:
The unit comes with a complete window installation kit for hassle-free setup.
- Assemble the window slider kit according to your window size (horizontal or vertical).
- Insert the exhaust hose into the exhaust hose adapter.
- Connect the exhaust hose adapter to the window slider kit.
- Place the window slider kit in the window opening and secure it.
- Connect the other end of the exhaust hose to the exhaust port on the back of the air conditioner.
- Asire w tout koneksyon yo byen fèm pou anpeche flit lè.

4. Operasyon Enstriksyon
Kontwòl Panel ak Remote Control:
The unit can be operated using the electronic control panel on top of the unit or the included full-function remote control.


Mòd operasyon:
- Mòd fre: Press the MODE button until the snowflake icon appears. Use the UP/DOWN arrows to set your desired temperature (61°F-88°F / 16°C-31°C).
- Mòd fanatik: Press the MODE button until the fan icon appears. The unit will circulate air without cooling. Adjust fan speed using the FAN SPEED button.
- Mòd dezimidifikatè: Press the MODE button until the water drop icon appears. The unit will remove moisture from the air. The fan speed is fixed in this mode.
Fonksyon adisyonèl:
- Vitès fanatik: Press the FAN SPEED button to cycle through Low, Medium, and High fan speeds.
- Revèy: Press the TIMER button to set the auto-on or auto-off time (1-24 hours).
- Auto Air Swing: Press the SWING button to activate or deactivate the automatic vertical louver movement for wider air distribution.
- Mòd dòmi: Activates a quiet operation mode with gradual temperature adjustments for comfortable sleep.
5. Antretyen
Antretyen regilye asire pèfòmans optimal epi pwolonje dire lavi èkondisyone pòtab ou a. Toujou debranche aparèy la anvan ou fè nenpòt antretyen.
Netwaye filtè lè a:
The unit features a washable pre-filter that should be cleaned regularly (every two weeks or as needed) to maintain efficiency.
- Etenn aparèy la epi debranche li nan priz kouran an.
- Locate the air filter panel (typically on the back or side of the unit).
- Retire filtè a lè w rale l dousman.
- Wash the filter under warm, running water with a mild detergent.
- Rense byen epi kite filtè a seche nèt nan lè a anvan ou mete l tounen. Pa ekspoze l anba limyè solèy dirèk.
- Once dry, carefully slide the filter back into its position.

Netwayaj Inite:
- Siye eksteryè inite a ak yon mou, damp twal. Pa sèvi ak pwodui chimik piman bouk oswa pwodui netwayaj abrazif.
- For long-term storage, drain any accumulated water (if applicable, though unit has auto evaporation), clean the filter, and cover the unit to protect it from dust.
NAN. Depanaj
Anvan ou kontakte sèvis kliyan, tanpri al gade gid depanaj sa a pou pwoblèm komen yo:
| Pwoblèm | Kòz posib | Solisyon |
|---|---|---|
| Inite pa limen | No power; Power cord not plugged in; Circuit breaker tripped; Unit is in standby mode. | Ensure unit is plugged into a working outlet. Check circuit breaker. Press the Power button. |
| Aparèy la pa refwadi byen | Air filter is dirty; Exhaust hose is blocked or disconnected; Room size too large; Doors/windows open; Temperature setting too high. | Clean air filter. Check exhaust hose connection and ensure it's not kinked. Close doors/windows. Lower temperature setting. Ensure room size is within unit's capacity. |
| Inite a fè bwi | Normal operating sounds (compressor, fan); Unit not on a level surface; Obstruction in fan. | Ensure unit is on a flat, stable surface. Check for any foreign objects near the fan. Some noise is normal during operation. |
| Dlo flit | Unit not level; Drainage plug not secure (if applicable). | Ensure unit is on a level surface. Check drainage plug. The unit features auto water evaporation, minimizing manual drainage. |
| Remote kontwòl pa travay | Pil yo mouri oswa yo mal mete; Telekòmand lan pa pwente nan direksyon reseptè a. | Replace batteries. Ensure correct polarity. Point remote directly at the unit's receiver. |
7. Espesifikasyon
| Karakteristik | Spesifikasyon |
|---|---|
| Nimewo Modèl | CBPAC815 |
| Dimansyon pwodwi (D x W x H) | 14.7" x 16.7" x 28.9" |
| Pwa atik | 62.5 liv |
| Manifakti | COBY |
| Faktè fòm | Pòtab |
| Voltage | 120 Volts |
| Nivo bri | 57 dB |
| Pouvwa Refwadisman (ASHRAE) | 12,000 Inite tèmik Britanik yo |
| Cooling Power (SACC/CEC) | 8,150 Inite tèmik Britanik yo |
| Refrijeran | R-32 |
| Kalite filtre | Pre-filtre ou ka lave |
| Zòn Kouvèti Maksimòm | 550 pye kare. |
8. Garanti & Sipò
Enfòmasyon sou garanti:
The Coby CBPAC815 Portable Air Conditioner comes with a 1-ane garanti limite apati dat acha a. Garanti sa a kouvri domaj nan materyèl ak nan fabrikasyon anba itilizasyon nòmal. Tanpri konsève prèv acha ou pou reklamasyon garanti.
Sipò Kliyan:
For technical assistance, warranty claims, or any questions regarding your Coby portable air conditioner, please contact Coby customer support. Refer to the contact information provided on the product packaging or the official Coby websit.
Additional protection plans may be available for purchase, offering extended coverage beyond the standard manufacturer's warranty. Please check with your retailer for details on 3-Year or 4-Year Protection Plans.