Xetron XT-Elog20-01

Xetron Elog20 Temperature and Humidity Data Logger User Manual

Model: XT-Elog20-01

1. Entwodiksyon

The Xetron Elog20 Temperature and Humidity Data Logger is designed for precise monitoring and recording of environmental conditions. It is widely used across all stages of cold chain storage and transportation, ensuring the integrity of temperature-sensitive goods such as pharmaceuticals and food products. This easy-to-use device automatically records measured temperature and humidity data, providing critical information for quality control and compliance.

2. Karakteristik kle

  • Dual Audible and Visual Alarm: Configure temperature and humidity monitoring ranges via software. The logger emits an audible and visual alarm if values exceed preset limits, providing timely alerts.
  • High Recording Capacity: Stores up to 16,000 readings, ensuring comprehensive data collection over extended periods.
  • Two High-Precision External Probes: Equipped with two external probes capable of detecting changes as small as 0.1℃ and 0.1%RH.
  • Large Display Screen: A 2.8-inch screen clearly displays real-time data and operational status.
  • Leman entegre: Two built-in magnets on the back allow for easy attachment to metallic surfaces, such as refrigerator walls. Additional fixing methods include screws and Velcro.
  • Detachable Buffered Probe: Ensures measurement stability by minimizing the impact of sharp changes or frequent fluctuations in temperature, providing more accurate data for sensitive applications like vaccine storage.
  • Free Software (Xetron Log): Provides an intuitive interface for setting logging intervals, alarm thresholds, and exporting data in PDF/Excel formats for detailed analysis.

3. Gid Enstalasyon

3.1 Debalaj ak Premye Enspeksyon

Carefully remove the data logger and its accessories from the packaging. Inspect all components for any signs of damage. Ensure the package contains the Elog20 data logger, external probes, and any included documentation.

3.2 Enstalasyon batri

The device includes one lithium metal battery. Locate the battery compartment on the back of the logger. Open the compartment, insert the battery according to the polarity markings, and close the cover securely.

3.3 Connecting External Probes

Connect the two external probes to the designated ports on the side or bottom of the Elog20 data logger. Ensure a firm connection. The probes are designed to be detachable and buffered for stable measurements.

Xetron Elog20 data logger with detachable buffered probe connected

Image: Xetron Elog20 data logger showing the connection point for the detachable buffered probe.

Xetron Elog20 data logger with external sensor placed inside a refrigerating box

Image: Xetron Elog20 data logger with its external sensor extended into a refrigerating box, demonstrating remote temperature monitoring.

3.4 Enstalasyon lojisyèl ak konfigirasyon inisyal

Download and install the "Xetron Log" software from the official Xetron website or the provided installation media. Connect the data logger to your computer via USB. Use the software to:

  • Set the desired logging interval (how frequently data is recorded).
  • Define temperature and humidity alarm thresholds (upper and lower limits).
  • Configure time zone and date settings.
  • Select measurement units (e.g., Celsius/Fahrenheit, %RH).
Xetron Elog20 data logger display next to a screenshot of the Xetron Log software interface

Image: The Xetron Elog20 data logger shown alongside a computer screen displaying the Xetron Log software, highlighting its data management and configuration capabilities.

4. Operasyon Enstriksyon

4.1 Kòmanse Anrejistreman Done yo

After configuring the settings via software, disconnect the logger from the computer. Press and hold the start button (usually indicated on the device) until the logging indicator light confirms recording has begun. Place the logger with its external probes in the environment to be monitored.

4.2 Monitoring Data on Display

The 2.8-inch large screen continuously displays real-time temperature and humidity readings, battery status, and logging status. This allows for quick visual checks without needing to connect to a computer.

Close-up of the Xetron Elog20 data logger's 2.8-inch large screen displaying temperature and humidity readings

Imaj: Yon imaj detaye view of the Xetron Elog20's large 2.8-inch display, showing current temperature and humidity values, along with logging status.

4.3 Understanding Alarms

If the monitored temperature or humidity exceeds the preset alarm thresholds, the Elog20 will activate its audible buzzer and visual LED indicators. Address the environmental conditions promptly to prevent damage to stored items. The alarm will cease once conditions return to within the acceptable range or if manually acknowledged/reset via software.

Xetron Elog20 data logger showing an alarm icon and sound wave graphic

Image: The Xetron Elog20 data logger displaying an active alarm, indicated by a speaker icon and radiating sound waves, signifying an out-of-range condition.

4.4 Stopping Data Logging and Data Download

To stop logging, press and hold the stop button (if available) or connect the logger to your computer and use the "Xetron Log" software to stop the session. Once logging is stopped, connect the device to your computer. Open the software to download the recorded data. The software allows for multi-format export, including PDF and Excel, for easy analysis and reporting.

5. Antretyen

5.1 Netwaye Aparèy la

Wipe the exterior of the data logger with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure the probes are clean and free from debris for accurate readings.

5.2 Ranplasman batri

When the battery indicator shows low power, replace the lithium metal battery promptly to ensure continuous operation and data integrity. Follow the instructions in section 3.2 for safe battery replacement.

5.3 Kalibrasyon

The Xetron Elog20 data logger is precisely calibrated by the factory. For re-calibration or verification services, please contact Xetron customer support. Do not attempt to self-calibrate without proper equipment and instructions, as this may affect accuracy.

NAN. Depanaj

PwoblèmKòz posibSolisyon
Aparèy pa limen.Low or depleted battery; incorrect battery installation.Replace the battery. Ensure battery is inserted with correct polarity.
No data logging.Logging not initiated; device memory full; incorrect settings.Ensure logging is started (refer to section 4.1). Download data and clear memory. Verify logging interval and other settings via software.
Lekti ki pa kòrèk.Dirty or damaged probes; improper probe placement; device malfunction.Clean probes. Ensure probes are correctly positioned in the environment. Contact support if issues persist after cleaning and repositioning.
Alarms not triggering.Alarm thresholds not set or set incorrectly; alarm function disabled.Verify alarm settings and ensure they are enabled in the Xetron Log software.
Cannot connect to PC/Software.USB cable issue; driver not installed; software not running correctly.Try a different USB port or cable. Reinstall Xetron Log software and drivers. Ensure the device is properly connected.

7. Espesifikasyon

KarakteristikDetay
Nimewo ModèlXT-Elog20-01
ManifaktiXetron
Dimansyon (L x W x H)16 x 10 x 2.5 cm
Pwa200 gram
Kalite batri1 Lithium metal (included)
Ranje Tanperati-40℃ pou rive +85℃ (-40°F pou rive 185°F)
Range imidite10% a 99% RH
Presizyon Tanperati±0.9°F (-40°F to 185°F)
Presizyon imidite±3% RH (-20% to 90% RH)
Anrejistreman Kapasite16,000 pwen
Ekspozisyon2.8-pous gwo ekran
Fikse MetòdWall mount (magnets, screw, Velcro)
Xetron Elog20 data logger with high-precision sensor and accuracy specifications

Image: The Xetron Elog20 data logger highlighting its high-precision sensor and factory-calibrated accuracy for temperature and humidity measurements.

Xetron Elog20 data logger mounted on a refrigerator door using built-in magnets

Image: The Xetron Elog20 data logger demonstrating its built-in magnets for easy attachment to a refrigerator door, illustrating one of its three fixing methods.

8. Garanti ak sipò

For any questions, technical assistance, or warranty inquiries regarding your Xetron Elog20 Temperature and Humidity Data Logger, please contact Xetron customer support. Refer to the product packaging or the official Xetron websit pou enfòmasyon kontak.

Dokiman ki gen rapò - XT-Elog20-01

Preview Manyèl Itilizatè Xetron STC-1000Pro TH Seri Kontwolè Tanperati Entelijan
Manyèl itilizatè konplè pou seri kontwolè tanperati entelijan Xetron STC-1000Pro TH la, ki detaye karakteristik li yo, operasyon li, enstalasyon li, ak espesifikasyon teknik li yo pou yon kontwòl tanperati ak imidite presi.
Preview Xetron STC-1000Pro Smart Tanperati Kontwolè Manyèl Itilizatè
Manyèl itilizatè pou kontwolè tanperati dijital entelijan Xetron STC-1000Pro a. Detaye karakteristik, operasyon, enstalasyon, ak espesifikasyon pou kontwòl tanperati presi nan aplikasyon tankou byè lakay, akwaryòm, ak enkubasyon.
Preview Manyèl Itilizatè Anrejistrè Done Tanperati/RH HOBO MX1101
Manyèl itilizatè konplè pou anrejistrè done HOBO MX1101 Bluetooth Low Energy (BLE) tanperati ak imidite relatif (Tanperati/RH). Aprann sou espesifikasyon yo, konfigirasyon an, operasyon an, ak depanaj la.
Preview testo 174 Bluetooth® Data Loggers User Manual
User manual for the testo 174 Bluetooth® data loggers, including models testo 174T BT and testo 174H BT. Provides detailed information on device overview, safety, intended use, setup, operation, maintenance, technical specifications, and troubleshooting. Features include Bluetooth connectivity via the testo Smart App.
Preview Sensitech SensiWatch Tracks & TempTale GEO Eagle User Guide for Cold Chain Monitoring
Comprehensive user guide for Sensitech's SensiWatch Tracks and TempTale GEO Eagle cold chain monitoring system, detailing shipment creation, device usage, alarm management, and reporting.
Preview Manyèl Anrejistrè Done Tanperati/RH HOBO MX1101
Manyèl itilizatè pou HOBO MX1101 Bluetooth Low Energy (BLE) Tanperati/RH Data Logger la. Li kouvri espesifikasyon, konfigirasyon, enstalasyon, operasyon, alam, telechajman done, ak enfòmasyon regilasyon.