TrolMaster HS-1

Logo TrolMaster

TrolMaster HS-1 Estasyon imidistat

Manyèl Enstriksyon

Entwodiksyon

The TrolMaster HS-1 Humidistat Station is designed to integrate with the Hydro-X control system, providing precise control over dehumidification systems. This module allows for the automated management of humidity levels by turning dehumidifiers on and off based on user-defined setpoints. It is compatible with dehumidifiers utilizing a 24V terminal for control.

This manual provides essential information for the proper installation, operation, and maintenance of your HS-1 Humidistat Station to ensure optimal performance and longevity.

Kontni pake

  • TrolMaster HS-1 Humidistat Station Module
  • Connection Cables (if included)
  • Materyèl aliye (si enkli)
TrolMaster HS-1 Humidistat Station packaging

Image: The HS-1 Humidistat Station packaging, showing the device and branding.

Pwodwi souview

Devan view of TrolMaster HS-1 Humidistat Station with display

Imaj: Devan view of the HS-1 Humidistat Station, displaying the current humidity (67%) and setpoint (56%), along with a 'FAN' button and 'Addressing' indicator.

The HS-1 features a clear display for monitoring current humidity and setpoint. It includes a 'FAN' button for manual control and an 'Addressing' indicator for system integration. The unit is designed for easy connection to the Hydro-X control system.

Side view of TrolMaster HS-1 Humidistat Station

Imaj: Bò kote view of the HS-1 Humidistat Station, showing its compact profile ak pwen montaj.

Enstalasyon ak Enstalasyon

  1. Mounting the HS-1: Select a suitable location for the HS-1 station, ensuring it is away from direct airflow from the dehumidifier or other environmental controls to obtain accurate humidity readings. Mount the unit securely using appropriate hardware.
  2. Connecting to Hydro-X System: Connect the HS-1 module to your existing Hydro-X control system using the provided RJ12 cable. The HS-1 connects to a DEVICE port on the Hydro-X controller.
    Diagram showing HS-1 Humidistat Station connected to Hydro-X Control System

    Image: Diagram illustrating the connection of the Humidistat Station to the Hydro-X Control System via an RJ12 cable, showing the DC power, Internet, Sensors, Devices, Line 1, Line 2, and Micro SD ports on the Hydro-X controller.

  3. Wiring to Dehumidifier (24V Terminal): The HS-1 is designed to control dehumidifiers that accept a 24V control signal. Refer to the wiring diagrams below for specific connections. Ensure all power is disconnected before making any wiring connections.
    HS-1 Wiring Diagram for multiple Anden Dehumidifiers

    Image: Wiring diagram for connecting the HS-1 to multiple Anden dehumidifiers. It shows connections for COMP (compressor), 24VAC, and FAN, along with a FLOAT SWITCH input, controlling multiple dehumidifier units (Unit 1 to Unit 5) with their respective FLOAT SWITCH, DH (dehumidifier), and VENT Dampers terminals.

    HS-1 Wiring Diagram for a single Anden Dehumidifier

    Image: Detailed wiring diagram for connecting the HS-1 to a single Anden Dehumidifier. It illustrates the connections for COMP (green wire to DH), 24VAC (red wire to DH), and FAN, including the FLOAT SWITCH input, showing the HS-1 in a Hydro-X system and the Anden Dehumidifier unit.

    Kle fil elektrik:

    • COMP: Connects to the compressor control terminal of the dehumidifier.
    • 24VAC: Provides 24V AC power for the dehumidifier's control circuit.
    • FANATIK: Connects to the fan control terminal of the dehumidifier.
    • SWITCH FLOTTE: Input for a float switch, typically used for condensate overflow protection.
  4. Pouvwa sou: Once all connections are secure, power on your Hydro-X system and the dehumidifier. The HS-1 will initialize and display current humidity readings.

Enstriksyon Operasyon

  1. Anviwònman Imidite Setpoint: The humidity setpoint is configured through your main Hydro-X controller. Navigate to the device settings for the HS-1 module and adjust the desired humidity level. The HS-1 will then automatically activate or deactivate the connected dehumidifier to maintain this setpoint.
  2. Siveyans Imidite: The HS-1's integrated display shows the current humidity percentage and the active setpoint. This allows for quick visual confirmation of environmental conditions.
  3. Bouton FAN: The 'FAN' button on the HS-1 can be used for manual control of the dehumidifier's fan, if supported by the dehumidifier and configured within the Hydro-X system. Consult your Hydro-X controller manual for specific fan control options.
  4. Adrese: The 'Addressing' indicator confirms that the HS-1 is properly recognized and communicating with the Hydro-X system. If this indicator is not active, check your RJ12 cable connection and Hydro-X system settings.

Antretyen

  • Netwayaj: Periodically wipe the exterior of the HS-1 module with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure no moisture enters the unit.
  • Swen Capteur: Keep the humidity sensor area (typically small vents on the unit) clear of dust and debris to ensure accurate readings. Do not obstruct these vents.
  • Enspeksyon kab: Regularly inspect all connected cables for any signs of wear or damage. Replace damaged cables immediately to prevent system malfunctions.

Depanaj

PwoblèmKòz posibSolisyon
HS-1 display is blank or unit is unresponsive.No power to Hydro-X system or HS-1 module.
Faulty RJ12 cable connection.
Ensure Hydro-X system is powered on.
Check RJ12 cable connection between HS-1 and Hydro-X controller. Try a different port or cable.
Dehumidifier not turning on/off as expected.Incorrect humidity setpoint.
Incorrect wiring to dehumidifier.
Dehumidifier malfunction.
Float switch activated.
Verify setpoint on Hydro-X controller.
Re-check wiring according to diagrams.
Test dehumidifier independently.
Check if the dehumidifier's float switch is engaged due to a full condensate tank or blockage.
Inaccurate humidity readings.Capteur bouche oswa sal.
HS-1 placed in an area with poor air circulation or direct airflow.
Clean sensor vents.
Relocate HS-1 to a more representative area for humidity measurement.
HS-1 not recognized by Hydro-X system.RJ12 cable issue.
Hydro-X system configuration error.
Ensure RJ12 cable is securely connected. Try a different cable or port.
Refer to your Hydro-X controller manual for adding or re-scanning devices.

Espesifikasyon

Dimensions of TrolMaster HS-1 Humidistat Station

Image: Diagram showing the dimensions of the HS-1 Humidistat Station: 3 inches (D) x 2 inches (W) x 4 inches (H).

KarakteristikDetay
Non modèlHS-1
Dimansyon pwodwi3"D x 2"W x 4"H
Pwa atik11.2 ons (0.7 Liv)
MateryèlPlastik
Mòd operasyonOtomatik
Karakteristik espesyalPlug and Play (with Hydro-X system)
Itilizasyon RekòmandeCommercial (Horticultural)
Konpozan ki enkliModil

Garanti ak sipò

TrolMaster products are designed for reliability and performance. For specific warranty information, please refer to the warranty card included with your product or visit the official TrolMaster websit la. Kenbe resi acha ou kòm prèv acha.

For technical support, troubleshooting assistance beyond this manual, or to inquire about replacement parts, please contact TrolMaster customer service. Contact details can typically be found on the official TrolMaster websit la oubyen nan anbalaj pwodwi w la.

Ofisyèl Websit: www.trolmaster.com

Dokiman ki gen rapò - HS-1

Preview Estasyon Imidistat TrolMaster HS-1: Gid Enstalasyon ak Operasyon
Yon gid konplè pou enstale ak opere Estasyon Imidistat TrolMaster HS-1 la pou kontwole dezumidifikatè nan sistèm Hydro-X la. Li kouvri karakteristik, etap enstalasyon, enstriksyon operasyon, espesifikasyon, ak dyagram fil elektrik.
Preview Manyèl Itilizatè ak Gid Sistèm Kontwòl Estasyon Imidistat TrolMaster HS-1 la
Manyèl itilizatè konplè pou Estasyon Imidistat TrolMaster HS-1 la, ki detaye enstalasyon, operasyon, karakteristik, espesifikasyon ak avètisman pou kontwole dezumidifikatè ak sistèm Hydro-X la.
Preview Estasyon san fil TrolMaster TWS-1: Gid itilizatè ak espesifikasyon
Gid konplè pou Estasyon San Fil TrolMaster TWS-1 la, ki kouvri enstalasyon, operasyon, koneksyon ak kontwolè Hydro-X Pro a, espesifikasyon yo, ak enfòmasyon regilasyon yo.
Preview TrolMaster DSR-1 25A Relay Device Station - Technical Specifications and Connection Guide
Detailed information on the TrolMaster DSR-1 25A Relay Device Station, including specifications, LED status indicators, and connection diagrams for horticultural control systems.
Preview TrolMaster TC-1 Grow Camera: User Guide and Specifications
Detaye souview, features, instructions, and specifications for the TrolMaster TC-1 Grow Camera, a high-quality surveillance camera for grow rooms. Learn about setup, internet access, mobile app usage, video recording, and FCC compliance.
Preview Kamera pou grandi TrolMaster TC-1: Siveyans, Karakteristik, ak Gid Enstalasyon
Gid konplè pou Kamera Kiltivasyon TrolMaster TC-1 la, ki detaye karakteristik li yo pou siveyans chanm kiltivasyon 24 sou 24, 7 jou sou 7, vizyon lannwit ki an sekirite pou plant yo, entegrasyon aplikasyon TM+, anrejistreman videyo, espesifikasyon, ak enstriksyon konfigirasyon.