1. Entwodiksyon ak souview
This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your Champion Power Equipment 4500-Watt Portable Inverter Generator, Model 200987. This ultra-quiet inverter generator is designed for various applications, including camping, tailgating, RV power, and providing backup for essential items. It features wireless remote start, quiet technology, and clean power output suitable for sensitive electronics.

Figure 1.1: Champion Power Equipment 4500-Watt Portable Inverter Generator.
2. Karakteristik kle
- Wireless Remote Start: Start and stop the generator from up to 80 feet away using the included wireless remote key fob.
- Quiet Technology: Operates at an ultra-quiet 61 dBA from 23 feet, comparable to normal conversation levels, making it suitable for noise-sensitive environments.
- Pare pou RV: Equipped with a 120V 30A RV (TT-30R) outlet for direct RV connection.
- Pouvwa pwòp: Produces less than 3% Total Harmonic Distortion (THD), ensuring safe operation for sensitive electronics.
- Entèlijans: Digital display monitors voltage, frequency, and operating hours for easy tracking.
- EZ Start Dial: Simplifies the startup process with an intuitive control dial.
- Mòd Ekonomi: Monitors power consumption in real-time, reducing engine wear, noise, and improving fuel efficiency.
- Paralèl pare: Can be connected with another 2800-watt or higher Champion inverter (optional parallel kit sold separately) to double output power.
- CO Shield: Carbon Monoxide Auto-Shutoff sensor automatically turns off the generator if dangerous levels of carbon monoxide are detected.
- Tan Egzekisyon Pwolonje: Runs for up to 14 hours at 25% load on a 2.3-gallon fuel tank.
- Pòtabilite: Features never-flat tires and a fold-down handle for easy transport.

Figure 2.1: Visual representation of the generator's key features.
3. Enstalasyon
Before operating your generator, ensure all components are correctly assembled and fluids are at appropriate levels.
3.1 Debalaj ak Premye Enspeksyon
- Carefully remove the generator and all accessories from the packaging.
- Inspect for any shipping damage. Contact customer support immediately if damage is found.
- Ensure all included accessories are present: wireless remote key fob, dual port USB adapter, and 10W-30 engine oil.

Figure 3.1: Included accessories for the generator.
3.2 Ajoute lwil motè
The generator is shipped without engine oil. It is crucial to add the correct amount and type of oil before the first start.
- Locate the oil fill cap/dipstick on the side of the engine.
- Retire bouchon ranpli lwil la.
- Using the provided 0.5-quart (10W-30) engine oil, carefully pour the oil into the engine. Do not overfill.
- Check the oil level using the dipstick; it should be at the upper limit.
- Remèt bouchon ranpli lwil la byen fèm.
3.3 Ajoute gaz
Use only clean, fresh, unleaded gasoline with an octane rating of 87 or higher.
- Asire w ke dèlko a sou yon sifas ki plat epi motè a etenn epi li frèt.
- Retire bouchon gaz la.
- Slowly add gasoline to the fuel tank, being careful not to overfill. The tank capacity is 2.3 gallons.
- Remèt bouchon gaz la byen fèm.
3.4 Konekte batri a (si sa aplikab)
The generator includes a Lithium Ion battery for electric start. Ensure it is properly connected before use.
- Locate the battery compartment (refer to the full operator's manual for exact location).
- Connect the battery terminals as instructed in the manual.
4. Operasyon Enstriksyon
Always operate the generator in a well-ventilated outdoor area, away from windows, doors, and vents.
4.1 Kòmanse Jeneratè a
The EZ Start Dial simplifies the starting process.
- Asire w ke dèlko a sou yon sifas ki plat.
- Turn the EZ Start Dial to the "CHOKE" position for a cold start.
- For electric start, press and hold the start button on the control panel or use the wireless remote key fob.
- Once the engine starts, slowly turn the EZ Start Dial to the "RUN" position.
- For manual recoil start, pull the recoil handle firmly until the engine starts.

Figure 4.1: Generator Control Panel with EZ Start Dial and outlets.
4.2 Wireless Remote Start
The wireless remote key fob allows convenient starting and stopping from a distance.
- Asire w ke switch prensipal kouran dèlko a nan pozisyon "ON".
- Press the "START" button on the remote key fob.
- To stop, press the "STOP" button on the remote key fob.
4.3 Mode Ekonomi
Activate Economy Mode to optimize fuel consumption and reduce noise during light loads.
- Press the "ECO" button on the control panel to activate/deactivate.
- The generator will automatically adjust engine speed based on the electrical load.
4.4 Konekte Aparèy Elektrik yo
The generator offers various outlets for different power needs.
- 120V 30A RV (TT-30R): For connecting RVs.
- Two 120V 20A Household Outlets (5-20R): Pou aparèy kay òdinè.
- 12V Automotive-Style Outlet: Pou aparèy 12V DC.
- Dual Port USB Adapter: Pou chaje aparèy ki mache ak USB.
Always ensure the total load does not exceed the generator's running wattage (3500 wat).

Figure 4.2: Generator in operation, providing power to a home.
5. Antretyen
Antretyen regilye asire pèfòmans optimal ak lonjevite dèlko ou a.
5.1 Chanjman lwil motè
Change the engine oil after the first 5 hours of operation, and then every 100 hours or annually thereafter.
- Asire w motè a cho men pa twò cho.
- Place a drain pan under the oil drain tube.
- Remove the oil drain tube cap and allow the oil to drain completely.
- Replace the drain tube cap and add fresh 10W-30 engine oil (0.5-quart capacity).
5.2 Netwayaj Filtè Lè a
Check and clean the air filter regularly, especially in dusty conditions.
- Remove the no-tool access panel to access the air filter.
- Remove the air filter element and clean it with warm, soapy water. Rinse thoroughly and allow to air dry completely.
- Reinstall the dry air filter element and secure the access panel.
5.3 Enspeksyon bouji
Enspekte bouji a chak 100 èdtan oswa chak ane.
- Remove the spark plug cap and use a spark plug wrench to remove the spark plug.
- Inspect for wear, carbon buildup, or damage. Clean or replace as necessary.
- Ensure the spark plug gap is correct before reinstalling.
NAN. Depanaj
Seksyon sa a adrese pwoblèm komen ou ka rankontre ak dèlko ou a.
6.1 CO Shield Auto-Shutoff
The CO Shield sensor is a safety feature designed to protect against dangerous carbon monoxide levels.
- If the generator shuts off unexpectedly and the CO Shield indicator light is on, move the generator to a well-ventilated outdoor area.
- Allow the generator to cool down before attempting to restart.
- Pa janm sèvi ak dèlko a andedan kay la oswa nan espas fèmen.
6.2 Pwoteksyon Surcharge
If the generator is overloaded, the circuit breakers will trip to protect the unit and connected devices.
- Reduce the electrical load by unplugging some devices.
- Press the reset button on the control panel for the tripped circuit breaker.
- If the breaker continues to trip, further reduce the load or inspect devices for faults.
6.3 Motè a pa demarre
If the engine fails to start, check the following:
- Asire w ke gen ase gaz nan tank la.
- Check the engine oil level; the low oil shut-off sensor will prevent starting if the oil is too low.
- Confirm the EZ Start Dial is in the correct "CHOKE" or "RUN" position.
- Enspekte bouji a pou wè si li pa sal oswa domaje.
7. Espesifikasyon
| Spesifikasyon | Valè |
|---|---|
| Mak | Champion Ekipman pouvwa |
| Non modèl | 4500-Watt RV Ready |
| Nimewo Modèl | 200987 |
| Kòmanse Wattage | 4500 Watts |
| Kouri Wattage | 3500 Watts |
| Kalite gaz | Gazolin |
| Volim tank gaz | 2.3 galon |
| Kalite motè | 4 Konjesyon Serebral |
| Deplasman motè | 212 santimèt kib |
| Kapasite lwil oliv | 0.5 Quart (10W-30 included) |
| Nivo bri | 61 dBA (from 23 feet) |
| Tan Kous (25% chaj) | Jiska 14 èdtan |
| Voltage | 120 Volts |
| Plòg pouvwa total | 5 (1x 30A RV, 2x 20A Household, 1x 12V, 1x Dual USB) |
| Pwa atik | 97 liv |
| Dimansyon pwodwi | 23.2"L x 17.7"L x 20.1"H |
| Karakteristik espesyal | Portable, Wireless Remote Start, Quiet Technology, RV Ready, Clean Power, CO Shield |
8. Enfòmasyon sou Sekirite
Operating a generator can be dangerous if proper safety precautions are not followed. Always read and understand the full operator's manual before use.
- Danje monoksid kabòn: Generators produce carbon monoxide, an odorless, colorless, and poisonous gas. Operate the generator ONLY outdoors and far away from windows, doors, and vents.
- Danje chòk elektrik: Never operate the generator in wet conditions. Ensure proper grounding to prevent electrical shock.
- Danje dife: Gasoline is highly flammable. Refuel only when the engine is off and cool. Store fuel in approved containers away from heat sources.
- Sifas cho: The generator's engine and muffler become very hot during operation and remain hot for some time after shutdown. Avoid touching hot surfaces.
9. Garanti ak sipò
Ch. ouampion Power Equipment 4500-Watt Portable Inverter Generator is backed by a 3-ane garanti limite.
For technical assistance, troubleshooting, or warranty claims, please contact Champion Support. They offer FREE lifetime technical support from dedicated experts.
Refer to your full operator's manual for detailed warranty terms and conditions, and for contact information for ChampSipò iyon.