OLMO OS-EL09ALP230V

OLMO 9,000 BTU 230V Ductless Mini Split Air Conditioner & Heat Pump User Manual

Model: OS-EL09ALP230V | Brand: OLMO

Entwodiksyon

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your OLMO 9,000 BTU 230V Ductless Mini Split Air Conditioner & Heat Pump. This system is designed to provide high-performance heating and cooling, suitable for various spaces including bedrooms, offices, and compact living areas. Please read this manual thoroughly before installation and use, and retain it for future reference.

Enfòmasyon sou Sekirite

Enstriksyon enpòtan pou sekirite:

Pwopozisyon 65 Avètisman: Pwodui sa a ka ekspoze ou nan pwodwi chimik ki gen ladan plon, ki se Eta Kalifòni konnen ki lakòz kansè ak domaj nesans oswa lòt domaj repwodiktif. Pou plis enfòmasyon ale nan www.P65Warnings.ca.gov.

Kontni pake

Verifye ke tout konpozan yo prezan epi yo pa domaje lè w ap debale yo:

Image showing the indoor unit, outdoor condenser, copper line set with communication wire, and remote control included in the package.

Figure 1: Included components of the OLMO Mini Split System.

Enstalasyon ak Enstalasyon

Nòt: This is not a DIY system. Professional installation by a qualified HVAC technician is required to ensure proper function, safety, and warranty validity. The condenser comes pre-charged with refrigerant.

Tcheke anvan enstalasyon:

Enstalasyon finiview (for Professional Reference):

  1. Mount the indoor unit securely on the wall, ensuring proper drainage slope.
  2. Position the outdoor condenser unit on a stable, level surface, away from obstructions.
  3. Connect the insulated copper line set between the indoor and outdoor units. Ensure proper flaring and torque.
  4. Connect the communication cable and drainage extension.
  5. Evacuate the system using a vacuum pump to remove air and moisture from the refrigerant lines.
  6. Open the valves on the outdoor unit to release the pre-charged refrigerant into the system.
  7. Connect the unit to the dedicated electrical circuit.
  8. Perform a leak check and test run to ensure proper operation.
An jeneral view of the OLMO 9,000 BTU Mini Split Air Conditioner and Heat Pump system, showing both indoor and outdoor units, and the remote control.

Figure 2: The complete OLMO Mini Split System.

Fèmen view of the indoor unit of the OLMO Mini Split Air Conditioner, showing its sleek design and digital display.

Figure 3: Indoor Unit of the OLMO Mini Split System.

Fèmen view of the outdoor condenser unit of the OLMO Mini Split Air Conditioner, highlighting the fan and OLMO branding.

Figure 4: Outdoor Condenser Unit of the OLMO Mini Split System.

Enstriksyon Operasyon

Your OLMO Mini Split system offers various modes and features for optimal comfort. All functions are controlled via the included remote control.

Image of the OLMO remote control with various buttons for mode, fan speed, temperature, timer, and special features.

Figure 5: Remote Control for the OLMO Mini Split System.

Operasyon debaz:

Karakteristik avanse:

Family watching TV in a living room with an OLMO mini split unit installed on the wall, illustrating cooling and heating solutions.

Figure 6: The OLMO Mini Split System providing comfort in a living space.

Antretyen

Regular maintenance ensures optimal performance and longevity of your OLMO Mini Split system. Always disconnect power before performing maintenance.

Netwayaj filtè lè:

Antretyen Inite Eksteryè a:

Depanaj

Before contacting technical support, please refer to the following common issues and solutions:

PwoblèmKòz posibSolisyon
Inite pa limen.No power supply; Remote control batteries dead.Tcheke disjonktè a; Ranplase pil kontwòl remote la.
Refwadisman/chofaj ensifizan.Dirty air filters; Obstruction to airflow; Incorrect mode setting; Low refrigerant.Clean air filters; Remove obstructions; Select correct mode; Contact professional for refrigerant check.
Bri etranj.Loose parts; Fan obstruction; Unit not level.Check for loose parts; Clear fan area; Ensure unit is level. If noise persists, contact support.
Dlo flit nan inite andedan kay la.Tiyo drenaj bouche; Enstalasyon ki pa kòrèk.Netwaye tiyo drenaj la; Kontakte yon pwofesyonèl pou enspeksyon.

Espesifikasyon

Detailed technical specifications for the OLMO 9,000 BTU 230V Mini Split System:

KarakteristikDetay
Non makELM
Enfòmasyon sou modèlAlpic
Nimewo Modèl AtikOS-EL09ALP230V
Dimansyon pwodwi48 x 40 x 40 inches (Shipping)
Kapasite refwadisman9,000 BTU
Kapasite chofajHeat Pump Functionality
Voltage230 Volts
Rapò Efikasite Enèji Sezonye (SEER)16.5
Heating Seasonal Performance Factor (HSPF)9.4
Kalite enstalasyonSistèm Split
RefrijeranR 410A
Karakteristik espesyalLED Display, Defrost, Heating, Inverter Technology, Louver Auto Swing, Remote Included, Comfortable Sleep Mode, Multiple Fan Speeds, Timer, Self Diagnosis, Intelligent Pre-heating, Auto Restart Function
KoulèBlan
Sous pouvwaFil elektrik
U.S. Government EnergyGuide label for OLMO Heat Pump Cooling and Heating Split System, showing Cooling Efficiency Rating (SEER) of 16.5 and Heating Efficiency Rating (HSPF) of 9.4.

Figure 7: EnergyGuide Label for OLMO Mini Split System.

Table of detailed specifications for various OLMO mini split models, including power supply, capacity, EER, SEER2, HSPF, noise levels, dimensions, and refrigerant type.

Figure 8: Comprehensive Technical Specifications Table for OLMO Mini Split Systems.

Garanti ak sipò

OLMO provides US-based technical support for your product. If you encounter any issues or require assistance with your mini split system, please contact our support team. Professional installation is required for warranty validity.

For support, please refer to the contact information provided with your purchase documentation or visit the official OLMO websit.

Dokiman ki gen rapò - OS-EL09ALP230V

Preview Manyèl itilizatè èkondisyone split OLMO ak ponp chalè
Manyèl itilizatè konplè pou èkondisyone split OLMO ak ponp chalè a, ki kouvri prekosyon sekirite, espesifikasyon inite a, karakteristik, swen ak antretyen, ak depanaj.
Preview Manyèl Itilizatè ak Gid pou Kontwolè Remote pou Èkondisyone OLMO
Gid konplè pou kontwòl remote èkondisyone OLMO a, ki kouvri espesifikasyon yo, fonksyon bouton yo, mòd operasyon yo, paramèt revèy la, ak karakteristik espesyal tankou FOLLOW ME ak SELF CLEAN. Modèl RG36F1/BGEFU1.
Preview Manyèl Itilizatè OLMO Sierra Series Wi-Fi
Manyèl itilizatè pou Sistèm Èkondisyone Mini Split Single-Zone Monte Sou Miray OLMO Sierra Series la, ki kouvri konfigirasyon ak kontwòl Wi-Fi atravè aplikasyon ConnectLife la.
Preview Manyèl Enstalasyon OLMO OS-EAH36-230VO pou Inite Eksteryè Santral Split Air Handler
Jwenn enstriksyon detaye sou enstalasyon pou inite ekstèn AHU milti-pozisyon OLMO OS-EAH36-230VO a. Manyèl sa a kouvri sekirite, konfigirasyon, fil elektrik, ak tès pou sistèm èkondisyone santral split.
Preview Manyèl itilizatè èkondisyone split OLMO ak ponp chalè
Comprehensive user manual for the OLMO Split Air Conditioner with Heat Pump, covering operation, maintenance, safety precautions, and troubleshooting. Includes detailed instructions and specifications.
Preview Enstriksyon ak garanti pou kontwolè a distans OLMO Multi SIERRA Series
Gid konplè pou itilizasyon kontwòl remote èkondisyone OLMO Multi SIERRA Series la, ki gen ladan eksplikasyon mòd, paramèt, ak enfòmasyon sou garanti limite.