1. Entwodiksyon
The Notifier FCM-1 is an intelligent addressable control module designed for use with Notifier's Fire Alarm Control Panels (FACPs). This module provides a supervised Class A or Class B Notification Appliance Circuit (NAC) for controlling external devices such as horns, strobes, or speakers. It communicates with the FACP using the FlashScan protocol, offering fast and reliable communication.
2. Enfòmasyon sou Sekirite
Enstriksyon enpòtan pou sekirite:
- Se sèlman pèsonèl kalifye ki dwe fè enstalasyon ak antretyen.
- Always disconnect power before installing, servicing, or removing the module.
- CAUTION: DE-ENERGIZE UNIT PRIOR TO SERVICING. Failure to do so may result in electrical shock or damage to the equipment.
- Respekte tout kòd ak règleman elektrik lokal ak nasyonal yo.
- Asire bon baz pou anpeche danje elektrik.
3. Pwodwi souview
The FCM-1 module allows the FACP to switch external power to notification appliances. It includes a built-in isolator to protect the communication loop in case of a short circuit. The module is designed for easy installation and addressing.

Figure 1: Notifier FCM-1 Intelligent Addressable Control Module, shown in its clear plastic packaging. The module is a light-colored square unit with two small circular openings and the "NOTIFIER by Honeywell" logo. A label on the packaging indicates "FCM-1" and "428101".
Karakteristik kle:
- Intelligent addressable control module.
- Configurable for Class A or Class B Notification Appliance Circuits (NAC).
- FlashScan protocol compatible.
- Built-in short circuit isolator.
- LED indicator for status.
4. Enstalasyon ak Enstalasyon
Proper installation is critical for the reliable operation of the FCM-1 module. Refer to the specific FACP installation manual for detailed wiring diagrams and compatibility information.
4.1 Addressing the Module
- Set the module's address using the rotary switches or programming tool as specified by the FACP manufacturer. Each module on the Signaling Line Circuit (SLC) must have a unique address.
- Record the assigned address for system documentation.
4.2 Enstriksyon fil elektrik
- Pwovizyon pou pouvwa: Connect the external power supply for the NAC to the designated terminals on the module. Ensure the power supply meets the requirements of the notification appliances.
- SLC Connection: Connect the SLC wiring from the FACP to the module's input terminals. Observe polarity.
- NAC Connection: Connect the notification appliances to the module's output terminals. For Class A wiring, ensure a return path to the module. For Class B, an End-Of-Line Resistor (EOLR) is required at the last device.
- Atè: Ensure the module and associated wiring are properly grounded according to local codes.
Note: Always verify all connections before applying power to the system.
5. Operasyon Enstriksyon
The FCM-1 module operates under the control of the connected Fire Alarm Control Panel (FACP). Once properly installed and addressed, the FACP will supervise the NAC and activate the connected notification appliances upon receiving an alarm condition.
5.1 Endikatè ki ap dirije
- Operasyon nòmal: The LED will flash periodically, indicating normal communication with the FACP.
- Alarm/Active: The LED will illuminate steadily when the module is activated (e.g., during an alarm).
- Pwoblèm: Specific flash patterns may indicate trouble conditions. Refer to the FACP manual for detailed trouble codes.
5.2 Tès Sistèm
Regular system testing, including the activation of the FCM-1 module and its connected notification appliances, should be performed according to local codes and manufacturer recommendations to ensure proper functionality.
6. Antretyen
The FCM-1 module requires minimal maintenance. Regular inspection and cleaning are recommended as part of the overall fire alarm system maintenance schedule.
- Enspeksyon vizyèl: Periodically inspect the module for any signs of physical damage, loose connections, or environmental degradation.
- Netwayaj: Si sa nesesè, netwaye deyò modil la dousman avèk yon twal mou epi sèk. Pa sèvi ak pwodui netwayaj abrazif oswa solvan.
- Tès sistèm: Ensure the module is included in routine system tests to confirm its operational status.
Always de-energize the unit prior to any maintenance or servicing.
NAN. Depanaj
If the FCM-1 module or its connected NAC is not functioning as expected, consider the following common troubleshooting steps:
- Pa gen aktivite LED:
- Verify power supply to the FACP and SLC.
- Check SLC wiring for breaks or short circuits.
- Confirm module address is correctly set and unique.
- Trouble Indication on FACP:
- Consult the FACP manual for specific trouble codes related to the module's address.
- Check NAC wiring for open circuits (missing EOLR for Class B, or wire break) or short circuits.
- Verify external power supply for the NAC is present and correct.
- Notification Appliances Not Activating:
- Ensure the FACP is in an alarm state.
- Check the external power supply for the NAC.
- Verify wiring to the notification appliances.
- Test individual notification appliances if possible.
If issues persist, contact qualified service personnel or Notifier technical support.
8. Espesifikasyon
| Atribi | Valè |
|---|---|
| Mak | Notifikatè |
| Modèl | FCM-1 |
| Nimewo Pati | 6018009186193 |
| Sous pouvwa | Corded Electric (for connected NAC) |
| Kalite Alam | Audible (controls audible devices) |
| Kalite Capteur | Photoelectric (refers to compatible detectors, not the module itself) |
| NAC Configuration | Klas A oswa Klas B |
Note: Specifications are subject to change without notice. Refer to the latest product datasheet for the most current information.
9. Enfòmasyon sou Garanti
Notifier products are typically covered by a limited warranty. For specific warranty terms and conditions, please refer to the official Notifier warranty statement provided with your purchase or visit the Notifier websit la. Kenbe prèv acha ou pou reklamasyon garanti.
10. Sipò ak Kontak
For technical assistance, product inquiries, or service, please contact your authorized Notifier distributor or visit the official Notifier website. Ensure you have your product model number (FCM-1) and any relevant system information ready when seeking support.
Notifikatè pa Honeywell
www.notifier.com