This manual provides comprehensive instructions for the installation, operation, and maintenance of the CQR Hold-up PA Double Push Panic Button. This device is designed to provide a reliable and immediate alert in emergency situations, integrating seamlessly with compatible alarm control panels. It features a double-press activation mechanism and a key-reset function to prevent accidental activation and ensure secure operation.

Please read this manual thoroughly before installation and use to ensure proper functionality and safety.

2. Enfòmasyon sou Sekirite

  • Sekirite elektrik: Installation should only be performed by qualified personnel in accordance with all local and national electrical codes. Ensure power to the alarm control panel is disconnected before wiring.
  • Montaj: Mount the device securely on a stable surface to prevent accidental dislodgement.
  • Anviwònman: Do not expose the device to extreme temperatures, humidity, or direct water. It is designed for indoor use only.
  • Antretyen: Do not attempt to open or repair the device yourself. Refer all servicing to qualified service personnel.
  • Tès: Regularly test the panic button's functionality in conjunction with your alarm system to ensure it is operating correctly.

3. Pake kontni

Verifye ke tout atik ki nan lis anba a yo prezan nan pakè ou a:

  • CQR Hold-up PA Double Push Panic Button Unit
  • Key for Reset Function
  • Mounting Screws (may vary)
  • Manyèl itilizatè sa a
CQR Hold-up PA Double Push Panic Button with key
Figure 3.1: The CQR Hold-up PA Double Push Panic Button, showing the two red push buttons, the keyhole for reset, and the included black reset key.
Close-up of the panic button reset key
Figi 3.2: Yon gwo plan view of the metallic key used to reset the panic button after activation.
Product packaging for CQR Double Push PA
Figure 3.3: The product packaging, displaying the "DOUBLE PUSH PA" label and a barcode.

4. Enstalasyon ak Enstalasyon

The CQR Hold-up PA Double Push Panic Button is designed for surface mounting and integration with a compatible alarm control panel.

4.1. Kote aliye

Choose a discreet yet easily accessible location for mounting, such as under a counter, desk, or near a point of sale. Ensure the surface is clean, dry, and structurally sound.

4.2. Wiring to Alarm Control Panel

  1. Dekonekte pouvwa: Before beginning any wiring, ensure the alarm control panel is completely powered off and disconnected from its main power source and backup battery.
  2. Tèminal Fil elektrik Aksè: Louvri casing of the panic button (if applicable) to expose the wiring terminals. Refer to your alarm control panel's manual for specific zone input terminals for panic devices.
  3. Konekte fil yo: Connect the panic button's output wires to the designated panic zone input terminals on your alarm control panel. This device typically operates as a Normally Closed (NC) contact, opening upon activation. Consult the wiring diagram provided with your alarm control panel for correct polarity and connection points.
  4. Sekirize fil elektrik: Asire w tout koneksyon fil yo byen fèm epi byen izole.
  5. Fèmen Casing: Carefully close the panic button casing.

4.3. Monte inite a

  1. Make twou yo: Use the panic button unit as a template to mark the drilling locations for the mounting screws on your chosen surface.
  2. Fè twou pilòt: Drill pilot holes if necessary, appropriate for the mounting screws.
  3. Aparèy sekirite: Align the panic button with the drilled holes and secure it firmly using the provided mounting screws. Do not overtighten.

4.4. Limen epi teste

Once installation is complete, restore power to the alarm control panel. Perform a functional test of the panic button as described in the "Operating Instructions" section to ensure it triggers the alarm system correctly.

5. Operasyon Enstriksyon

5.1. Activating the Panic Button

To activate the panic alarm, simultaneously press both red push buttons on the front of the unit. The double-press mechanism is designed to minimize accidental activations while ensuring quick response in an emergency.

Upon successful activation, the panic button will latch, and the alarm control panel will initiate the programmed panic response (e.g., siren activation, silent alarm, notification to monitoring station).

5.2. Resetting the Panic Button

After activation, the panic button will remain in a latched state until manually reset. To reset the device:

  1. Insert the provided key into the keyhole located on the top surface of the panic button.
  2. Turn the key clockwise (or counter-clockwise, depending on the specific mechanism) until the buttons release and return to their original position.
  3. Remove the key. The panic button is now reset and ready for re-activation.

Enpòtan: Always keep the reset key in a secure and accessible location known only to authorized personnel.

6. Antretyen

The CQR Hold-up PA Double Push Panic Button requires minimal maintenance to ensure reliable operation.

  • Netwayaj: Periodically wipe the exterior of the unit with a soft, dry cloth. Do not use abrasive cleaners, solvents, or excessive moisture.
  • Tès: It is recommended to test the panic button's functionality at least once a month to confirm its connection to the alarm system and proper activation/reset.
  • Enspeksyon: Visually inspect the unit for any signs of damage, loose wiring, or tampering.

NAN. Depanaj

If you encounter issues with your CQR Hold-up PA Double Push Panic Button, refer to the following common problems and solutions:

PwoblèmKòz posibSolisyon
Panic button does not activate alarm.
  • Incorrect wiring to alarm panel.
  • Koneksyon fil ki lach.
  • Alarm panel zone not properly configured.
  • Aparèy fonksyone byen.
  • Verify wiring against alarm panel manual.
  • Tcheke epi an sekirite tout koneksyon fil yo.
  • Consult alarm panel manual for zone programming.
  • Contact qualified service personnel if issue persists.
Panic button does not reset with key.
  • Key not fully inserted or turned correctly.
  • Internal mechanism obstruction or damage.
  • Ensure key is fully inserted and turned firmly.
  • Do not force the key. If still stuck, contact service personnel.
Accidental activations.
  • Move kote pou monte.
  • Physical obstruction.
  • Relocate the device to a less prone area.
  • Ensure no objects are pressing against the buttons.

If the problem persists after attempting these solutions, please contact your alarm system installer or the manufacturer's technical support.

8. Espesifikasyon

KarakteristikDetay
ModèlHold-up PA Double Push
ASINB07WWCXZC9
MakCQR
ManifaktiSecurity Components LTD
KoulèBlan
Kalite AktivasyonDouble Press Latching
Reset MechanismReyajiste kle
KonpatibiliteUniversal operation with Alarm control panel
Dat Premye Disponib22 out 2019

9. Garanti ak sipò

Specific warranty information for the CQR Hold-up PA Double Push Panic Button is not provided within this manual. For details regarding warranty coverage, terms, and conditions, please refer to the documentation included with your purchase or contact the retailer or manufacturer directly.

For technical support, installation assistance, or troubleshooting beyond the scope of this manual, please contact your alarm system installer or the manufacturer, Security Components LTD, through their official channels.

You can visit the CQR Store on Amazon for more information: CQR Store

Dokiman ki gen rapò - B07WWCXZC9

Preview CQR Panic Buttons: Understanding and Specifications
Comprehensive souview of CQR panic buttons, detailing types, features, security grades, and technical specifications for domestic and commercial applications.
Preview CQR Panic Buttons: Understanding and Product Specifications
A comprehensive guide to CQR panic buttons, detailing their functionality, types (mechanical, electronic, single/double push, confirmed), reset methods, fitting options, and finishes. Includes detailed product specifications and comparisons for the PASP, PADP, and EPA ranges.
Preview CQR FP3 Manual Call Point & Security Devices | Technical Overview
Teknik detaye souview of CQR's FP3 Manual Call Point, featuring single and double pole configurations, EN54-11 certification, and other security products including Personal Attack Buttons, FP2 Call Points, Junction Boxes, and Empty Boxes.
Preview Aparèy pou kenbe CQR PADP3 Seri: Enstriksyon pou itilize ak enstale
Gid konplè pou enstalasyon ak itilizasyon aparèy bloke CQR PADP3 Seri a, ki kouvri konfigirasyon, espesifikasyon ak karakteristik sistèm sekirite yo.
Preview CQR PADP2 Grade 1: Double Push Hold Up Device | Security Solutions
Explore the CQR PADP2 Grade 1 Double Push Hold Up Device. This brochure details its features, technical specifications, product codes, and compliance with PD6662:2010 for reliable security applications.
Preview CQR Security Intruder Detection Systems Product Catalog
Comprehensive product catalog from CQR Security detailing intruder detection systems, including a wide range of cables, magnetic contacts, sounders, shock sensors, hold-up devices, call points, power supplies, junction boxes, exit buttons, and 12V fire detectors for security applications.