1. Entwodiksyon
This manual provides detailed instructions for the safe installation, operation, and maintenance of your Akicon 1424-ORB Bathroom Exhaust Fan with Light and Nightlight. Please read all instructions carefully before beginning installation or use. Retain this manual for future reference.
The Akicon 1424-ORB is an ultra-quiet ventilation solution designed to effectively remove moisture and odors from your bathroom. It features a powerful 110 CFM fan, an integrated main light, and a nightlight, all within a durable oil rubbed bronze finish.
2. Enfòmasyon sou Sekirite
WARNING: RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS.
- Installation must be performed by a qualified electrician in accordance with all applicable local codes and standards, including fire-rated construction codes and standards.
- Always disconnect power at the service panel before wiring or servicing this unit. Lock out the service panel to prevent accidental power-on.
- Aparèy sa a fèt sèlman pou itilizasyon vantilasyon jeneral. Pa sèvi avè l pou retire materyèl ak vapè danjere oswa eksplozif.
- To prevent motor damage and noisy/unbalanced impellers, keep drywall spray, construction dust, etc., off the power unit.
- Duct work must be installed with a minimum of 4-inch diameter to ensure proper airflow.
- Asire w ke vantilatè a byen konekte ak tè a.
- Do not install this fan in a cooking area.
3. Pake kontni
Verifye ke tout konpozan yo prezan anvan ou kòmanse enstalasyon an:
- Lojman Fan
- Grille
- Limyè Kouvri
- 12-inch Suspension Bracket
- 14-inch Extension Bracket
- Montaj Vis
- Grille and Cover Mounting Hardware
- LED Bulb (Main Light)
- Anpoul limyè lannwit
4. Espesifikasyon
| Mak | Akicon |
| Non modèl | 1424-ORB |
| Koulè | Lwil oliv fwote an kwiv |
| Airflow | 110 CFM |
| Sone Rating | 1.5 son |
| Gwosè chanm rekòmande | Jiska 99 pye kare. |
| Dimansyon Lojman (L x W x H) | 9" x 9" x 7-11/16" |
| Light Cover Diameter | 15-5/16" |
| Gwosè kanal | 4 pous |
| Main limyè | 3 x 9W GU24 Dimmable LED Bulbs (3000K / 5000K) |
| Limyè lannwit | 1 x 4W E12 Bulb |
| Materyèl | Metal, Plastic, Glass Cover |
| Kalite motè | Copper Ball-Bearing Motor |
| Sètifikasyon | HVI-certified, cUL listed (for over-showers and tubs with GFCI) |
5. Enstriksyon Enstalasyon
Proper installation is crucial for the performance and longevity of your exhaust fan. It is recommended that installation be performed by a qualified professional.
5.1 Konsiderasyon Pre-Enstalasyon
- Aksè: This fan is designed for installation in locations with attic access or during new construction. Replacing an existing fan may require modifications to the ceiling opening.
- Gwosè ouvèti: The housing dimensions are 9 inches by 9 inches by 7-11/16 inches. Ensure your ceiling opening is appropriately sized. If replacing an older fan, you may need to enlarge the opening.
- Kanal: Use 4-inch diameter ducting for optimal performance. Ensure duct runs are as short and straight as possible.
- Gwosè chanm: The fan is suitable for rooms up to 99 square feet. To calculate the minimum CFM needed for your bathroom, multiply the room's width, length, and height (in feet) by 0.13.





5.2 Monte Lojman an
- Position the fan housing between ceiling joists. Use the provided 12-inch or 14-inch suspension/extension brackets to secure the housing to the joists.
- Ensure the housing is level and securely fastened to prevent vibration and noise.
- Connect the 4-inch ductwork to the fan's exhaust collar. Seal all duct connections with duct tape or clamps to prevent air leakage.
5.3 fil elektrik
The fan, main light, and nightlight can be wired jointly or separately to wall switches, depending on your preference and existing wiring. Consult a qualified electrician if you are unsure about wiring procedures.
- Route electrical supply wires to the fan housing's junction box.
- Remove the junction box cover and connect the wires according to the wiring diagram provided inside the junction box cover and local electrical codes. Ensure proper grounding.
- Konekte tout fil yo byen sere ak konektè fil ki apwouve yo.
- Ranplase kouvèti bwat junction la.
5.4 Fini enstalasyon an
- Install the provided LED bulb for the main light and the E12 bulb for the nightlight into their respective sockets.
- Attach the light cover to the fan housing using the provided hardware.
- Secure the grille to the housing.
- Restore power at the service panel and test the fan, main light, and nightlight functions.

6. Operasyon Enstriksyon
The Akicon 1424-ORB fan operates via standard wall switches. Depending on your wiring configuration, you may have separate switches for the fan, main light, and nightlight, or a single switch controlling multiple functions.
- Operasyon Fan: Activate the fan by flipping the designated wall switch. The fan will begin to exhaust air from the room.
- Operasyon Limyè Prensipal: Turn on the main LED light using its dedicated wall switch. The main light provides ample illumination for your bathroom.
- Nightlight Operation: Activate the nightlight with its separate wall switch. The nightlight offers a soft glow for low-light conditions.
- Karakteristik dimmable: The main LED bulbs are dimmable. If connected to a compatible dimmer switch (not included), you can adjust the brightness. The color temperature can be set to 3000K (warm light) or 5000K (bright light) as per the bulb's specifications.
7. Antretyen
Regular cleaning and maintenance will ensure optimal performance and extend the life of your exhaust fan.
7.1 Cleaning the Grille and Light Cover
- Dekonekte pouvwa: Toujou etenn kouran an nan panèl sèvis la anvan ou netwaye.
- Retire Eleman: Carefully remove the light cover and grille from the fan housing.
- Netwaye: Wash the grille and light cover with a mild detergent and warm water. Rinse thoroughly and allow them to dry completely before reinstallation.
- Réinstaller: Reattach the light cover and grille to the fan housing.
7.2 Netwayaj enteryè vantilatè a
- Dekonekte pouvwa: Asire w ke panèl sèvis la koupe kouran an.
- Access Fan: Remove the grille and light cover.
- Netwaye lam vantilatè yo: Use a soft cloth or brush to gently clean dust and debris from the fan blades and motor housing. Avoid using harsh chemicals or abrasive cleaners.
- Remonte: Once clean and dry, reassemble the light cover and grille.
- Retabli pouvwa: Turn power back on at the service panel.
NAN. Depanaj
If you experience issues with your Akicon exhaust fan, refer to the following common problems and solutions:
| Pwoblèm | Kòz posib | Solisyon |
|---|---|---|
| Fanatik pa fonksyone | No power supply; Loose wiring; Faulty switch; Motor failure. | Check circuit breaker/fuse. Verify all wire connections. Test switch. If motor failure is suspected, contact customer support. |
| Limyè pa limen | No power supply; Loose wiring; Burnt-out bulb; Faulty switch. | Check circuit breaker/fuse. Verify wire connections. Replace bulb. Test switch. |
| Twòp bri oswa Vibration | Loose mounting; Debris in fan blades; Damaged motor/impeller; Improper ducting. | Ensure housing is securely mounted. Clean fan blades. Check ductwork for obstructions or kinks. If noise persists, contact customer support. |
| Poor ventilation performance | Blocked ductwork; Undersized fan for room; Excessive duct length/bends. | Check ductwork for obstructions. Ensure ducting is 4-inch diameter. Review room size vs. fan CFM. |
If troubleshooting steps do not resolve the issue, please contact Akicon customer support for assistance.
9. Garanti ak sipò
The Akicon 1424-ORB Bathroom Exhaust Fan with Light and Nightlight is covered by a 3-ane garanti limite soti nan dat acha a. Garanti sa a kouvri domaj nan materyèl ak atizan konn fè nan itilizasyon nòmal.
For warranty claims, technical support, or any questions regarding your product, please contact Akicon customer service. Keep your proof of purchase for warranty validation.
For more information or to contact support, please visit the official Akicon websit la oubyen gade enfòmasyon kontak ki te vini ak dokiman acha w la.