TRUPER 13499

Manyèl Itilizatè Ponp Ranfòsè Presyon Truper 13499 PRES-1/3T

Model: 13499 / PRES-1/3T

1. Entwodiksyon

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Truper 13499 PRES-1/3T 1/3 HP Pressure Booster Pump. Please read these instructions carefully before installation and use to ensure proper function and to prevent damage or injury. Keep this manual for future reference.

2. Enfòmasyon sou Sekirite

Toujou obsève prekosyon sekirite sa yo:

3. Pwodwi konpozan

The Truper 13499 PRES-1/3T Pressure Booster Pump includes the main pump unit, an integrated pressure switch, and power cord with an on/off switch. Refer to the image below for a visual representation of the pump and its key components.

Truper 13499 PRES-1/3T Pressure Booster Pump

Figi 1: Truper 13499 PRES-1/3T Pressure Booster Pump. This image shows the complete pump assembly, including the orange motor housing, the dark gray pump body, brass fittings for water inlet and outlet, and the integrated flow switch with an arrow indicating water flow direction. The power cord with an inline on/off switch is also visible.

Konpozan kle:

4. Enstalasyon ak Enstalasyon

Bon enstalasyon enpòtan anpil pou pèfòmans ak lonjevite ponp lan.

  1. Kote:
    • Install the pump in a dry, well-ventilated area, protected from direct sunlight, rain, and freezing temperatures.
    • Ensure the pump is placed on a stable, level surface to minimize vibration.
    • Allow adequate space around the pump for ventilation and maintenance access.
  2. Koneksyon plonbri:
    • Connect the pump to the water supply line using appropriate plumbing fittings. Ensure all connections are watertight.
    • Observe the flow direction indicated by the arrow on the flow switch (Figure 1). The pump must be installed in line with the water flow.
    • Use flexible connectors to reduce vibration transmission to the plumbing system.
    • Install shut-off valves on both the inlet and outlet sides of the pump for easier maintenance.
  3. Koneksyon elektrik:
    • Ensure the power outlet is properly grounded and matches the pump's electrical requirements (127 V - 60 Hz).
    • Plug the pump's power cord into the grounded outlet.
    • Do not use extension cords unless absolutely necessary, and ensure they are rated for the pump's power requirements.
  4. Priming ponp lan:
    • Before initial operation, ensure the pump is filled with water to prevent dry running. Open a faucet downstream to allow air to escape.
    • Once water flows steadily from the faucet, close it. The pump is now primed.

5. Operasyon Enstriksyon

The Truper 13499 PRES-1/3T pump operates automatically based on water flow.

  1. Premye kòmansman:
    • After installation and priming, ensure the inline switch on the power cord is in the "OFF" position.
    • Ploge ponp lan nan yon priz elektrik apwopriye.
    • Switch the inline power switch to the "ON" position. The pump will remain off until water flow is detected.
  2. Operasyon otomatik:
    • When a water outlet (e.g., faucet, shower) is opened, the flow switch detects water movement.
    • The pump automatically starts, boosting water pressure.
    • When the water outlet is closed, the flow stops, and the pump automatically shuts off after a short delay.
  3. Sik devwa:
    • The pump is designed for intermittent use: 50 minutes of work followed by 20 minutes of rest.
    • The daily maximum operating time is 6 hours. Adhering to this duty cycle will prolong the pump's lifespan.

6. Antretyen

Antretyen regilye asire pèfòmans optimal epi pwolonje lavi ponp ou a.

Warning: Always disconnect the pump from the power supply before performing any maintenance.

NAN. Depanaj

This section addresses common issues you might encounter with your pressure booster pump.

PwoblèmKòz posibSolisyon
Ponp pa kòmanse.Pa gen ekipman pou pouvwa.
Inline switch is OFF.
Pa gen okenn koule dlo detekte.
Tcheke priz kouran an ak disjonktè a.
Turn inline switch to ON.
Open a water outlet to initiate flow. Ensure pump is primed.
Ponp kouri kontinyèlman.Leak in plumbing system.
Flow switch malfunction.
Constant low water flow.
Check all connections for leaks and repair.
Kontakte pèsonèl sèvis kalifye.
Ensure all outlets are fully closed.
Insufficient pressure boost.Ponp pa byen prime.
Inlet water pressure too low.
Obstruction in plumbing.
Re-prime ponp lan.
Ensure minimum input pressure of 0.72 PSI is met.
Inspect plumbing for blockages.
Ponp lan fè anpil bri oswa li vibre twòp.Lè nan sistèm lan.
Montaj ki lach.
Internal component wear.
Re-prime the pump to remove air.
Ensure pump is securely mounted on a stable surface.
Kontakte pèsonèl sèvis kalifye.

8. Espesifikasyon teknik

KarakteristikSpesifikasyon
Modèl13499 / PRES-1/3T
Pouvwa1/3 HP (248 W)
Voltage - Frequency127 V - 60 Hz
Koule maksimòm15 gal/min (27 L/min) / 60 Liters Per Minute
Minimum Input Pressure0.72 psi
Presyon maksimòm17 psi
Sik devwa50 min. work per 20 min. rest
Daily Maximum Operation6 èdtan
MateryèlAliminyòm casing
Pwa9 lb (4.3 Kg) / 10.36 pounds (shipping)
Dimensions (B x H x W)5 1/8" x 11 13/16" x 6 5/16" (13 x 30 x 16 cm) / 7.09 x 5.91 x 5.91 inches (product)
Water Outlets SupportedJiska 3 similtane
Kalite operasyonOn demand (Autostop switch)

9. Garanti ak sipò

For warranty information or technical support, please refer to the documentation included with your purchase or contact Truper customer service. Keep your purchase receipt as proof of purchase.

For further assistance, visit the official Truper websit la oubyen kontakte sant sèvis otorize yo.

Dokiman ki gen rapò - 13499

Preview Truper PRES-1 Water Pressure Booster Pump Manual
Comprehensive manual for the Truper PRES-1 water pressure booster pump, covering technical specifications, safety warnings, installation, operation, maintenance, and troubleshooting.
Preview Manyèl Itilizatè Ponp Ranfòsè Presyon Dlo Reglabl TRUPER PRE-1/3
Manyèl itilizatè konplè pou ponp ranfòsè presyon dlo reglabl TRUPER PRE-1/3 la. Gen ladan l espesifikasyon teknik, enstriksyon sekirite, gid enstalasyon, pwosedi antretyen, konsèy depanaj, ak enfòmasyon sou garanti.
Preview TRUPER PRE-1/6 Water Pressure Booster Pump Manual
Official instruction manual for the TRUPER PRE-1/6 Water Pressure Booster Pump. Includes technical specifications, safety warnings, installation guide, maintenance, troubleshooting, and warranty information.
Preview Manyèl Itilizatè Ponp Ranfòsè Presyon Dlo TRUPER PRE-1/6R
Manyèl itilizatè konplè pou ponp ranfòsman presyon dlo TRUPER PRE-1/6R la, ki kouvri espesifikasyon teknik, avètisman sekirite, gid enstalasyon, enstriksyon fonksyònman, pwosedi antretyen, ak konsèy depanaj.
Preview Manyèl Sistèm Ranfòsman Presyon Idwopnematik TRUPER - HIDR-1/2X24, HIDR-1/2X50
Comprehensive user manual for the TRUPER Hydropneumatic Pressure Boosting System (Models HIDR-1/2X24, HIDR-1/2X50), covering technical data, power requirements, safety warnings, parts identification, installation guide, pressure switch operation, start-up procedures, maintenance, troubleshooting, authorized service centers, and warranty policy.
Preview TRUPER Adjustable Water Pressure Booster Pump PRE-1/6R User Manual
Comprehensive user manual for the TRUPER Adjustable Water Pressure Booster Pump, Model PRE-1/6R. Includes technical specifications, installation instructions, safety warnings, maintenance, and troubleshooting.