This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Truma Ultraheat Control Panel, model 30030-47100. This control panel is designed to regulate the Truma Ultraheat electric heater, allowing users to select desired temperature and power output levels.
2. Enfòmasyon sou Sekirite
Please read and understand all safety instructions before installing or operating the control panel. Failure to follow these instructions may result in electric shock, fire, or personal injury.
- Installation must be performed by a qualified technician in accordance with all local and national electrical codes.
- Ensure the power supply to the heater system is disconnected before any installation, maintenance, or repair work.
- Do not operate the control panel if it is damaged or malfunctioning.
- Keep the control panel dry and away from moisture.
- This device operates on 230V AC. Handle with extreme care.
3. Enstalasyon ak Enstalasyon
The Truma Ultraheat Control Panel (model 30030-47100) is supplied without a connecting cable. Professional installation is required for proper and safe operation.
3.1 Kontni pake a
- 1x Truma Ultraheat Control Panel (Black, without cable)
3.2 Dimansyon ak pwa
- Dimansyon pwodwi: Apeprè 3.82 x 3.86 x 2.01 pous (9.7 x 9.8 x 5.1 cm)
- Pwa atik: Apeprè 2.11 ons (60 gram)
3.3 Montaj ak fil elektrik
The control panel is designed for flush mounting. Ensure adequate space behind the mounting surface for wiring connections. The control panel requires connection to the Truma Ultraheat electric heater and a 230V AC power supply. Refer to the Truma Ultraheat heater's specific installation manual for detailed wiring diagrams and instructions. All electrical connections must be made by a certified electrician.

Figure 1: Truma Ultraheat Control Panel alongside its black mounting frame/bezel. This image illustrates the two main components for installation.
4. Operasyon Enstriksyon
The Truma Ultraheat Control Panel features a single rotary dial for selecting both the desired temperature and the electric heating power level.

Figi 2: Close-up view of the Truma Ultraheat control panel, showing the rotary dial with temperature settings (1-7) and power levels (500W, 1000W, 2000W), and "230 V~" marking.
4.1 Power and Temperature Selection
- Off Position (O): Rotate the dial to the 'O' position to turn off the electric heating function.
- Seleksyon Nivo Puisans:
- 500: Select this position for 500 Watts of electric heating power.
- 1000: Select this position for 1000 Watts of electric heating power.
- 2000: Select this position for 2000 Watts of electric heating power.
Note: The available power levels depend on the campsite's fuse protection. Choose a power level appropriate for your electrical supply to avoid overloading. The control panel indicates "230 V~" for its operating voltage.
- Temperature Setting (1-7): Once a power level (500, 1000, or 2000) is selected, you can further adjust the desired room temperature using the inner dial marked with numbers 1 through 7.
- 1: Lowest temperature setting.
- 7: Pi wo anviwònman tanperati.
The heater will operate to maintain the selected temperature based on the chosen power level.
5. Antretyen
The Truma Ultraheat Control Panel requires minimal maintenance. Follow these guidelines to ensure its longevity:
- Netwayaj: Wipe the surface of the control panel with a soft, damp twal. Pa sèvi ak pwodui netwayaj abrazif, solvan, oswa pwodui chimik ki agresif, paske sa yo ka domaje fini an oswa konpozan entèn yo.
- Enspeksyon: Periodically check the control panel for any signs of damage, loose connections, or unusual operation. If any issues are observed, contact a qualified technician.
- Pa gen pati itilizatè ki ka fè sèvis: The control panel contains no user-serviceable parts. Do not attempt to open or repair the unit yourself.
NAN. Depanaj
If you experience issues with your Truma Ultraheat Control Panel, consider the following basic troubleshooting steps:
- Pa gen pouvwa:
- Check the main power supply to your vehicle/system.
- Verify that the circuit breaker for the Truma Ultraheat heater is not tripped.
- Ensure all electrical connections to the control panel and heater are secure.
- Heater Not Responding:
- Confirm the control panel dial is set to a power level (500, 1000, or 2000) and a temperature setting (1-7), not 'O'.
- Ensure the Truma Ultraheat heater itself is functioning correctly. Refer to the heater's manual for specific troubleshooting.
- Chofaj enkonsistan:
- Check the selected power level; a lower power level will heat more slowly.
- Ensure the ambient temperature sensor (if external to the control panel) is not obstructed or exposed to drafts.
If the problem persists after performing these checks, it is recommended to contact a qualified Truma service technician for diagnosis and repair.
7. Espesifikasyon
| Mak | Truma |
| Nimewo Modèl | 30030-47100 |
| Manifakti | Truma |
| Dimansyon pwodwi | 3.82 x 3.86 x 2.01 pous (9.7 x 9.8 x 5.1 cm) |
| Pwa atik | 2.11 ons (60 gram) |
| Opere Voltage | 230 V~ |
| Nivo pouvwa | 500 W, 1000 W, 2000 W |
8. Garanti ak sipò
For information regarding warranty terms and conditions, please refer to the documentation provided with your Truma Ultraheat electric heater or visit the official Truma website. For further assistance, technical support, or to locate an authorized service center, please contact Truma customer support directly.