Came 8K01MP-012 AXI20K05

Came 8K01MP-012 AXI20K05 Swing Gate Kit Instruction Manual

For Swing Gates up to 2 Meters

1. Entwodiksyon

This manual provides comprehensive instructions for the installation, operation, and maintenance of the Came 8K01MP-012 AXI20K05 Swing Gate Kit. This kit is designed for automating swing gates up to 2 meters in length per leaf, operating on a 24V DC system. Please read this manual carefully before proceeding with any installation or operation to ensure safe and correct use of the product.

The Came Axi motor combines advanced technical solutions with sophisticated electronics, ensuring consistent movement and linear slowdowns. This system is engineered for high performance, even under intensive use, providing a secure and reliable automation solution.

Came 8K01MP-012 AXI20K05 Swing Gate Kit components

Figi 1: Plis paseview of the Came 8K01MP-012 AXI20K05 Swing Gate Kit components.

2. Enfòmasyon sou Sekirite

WARNING: Improper installation or use can lead to serious injury or property damage. Always follow safety guidelines.

3. Pake kontni

The Came 8K01MP-012 AXI20K05 kit includes the following components:

4. Gid Enstalasyon

This section outlines the general steps for installing the Came 8K01MP-012 AXI20K05 swing gate kit. Refer to the detailed diagrams and specific instructions provided with each component for precise measurements and connections.

4.1 Chèk Pre-Enstalasyon

4.2 Motor Installation (001SWN20 AXI20DGS)

  1. Mount the motor brackets securely to the gate post and gate leaf according to the provided template. Ensure correct alignment for optimal gate movement.
  2. Attach the motors to the brackets. The motors should be level and allow for the full range of gate motion.
  3. Connect the motor cables to the control panel, following the wiring diagram.

Figure 2: Illustration of motor mounting on a gate post and leaf. (Image not provided, refer to product manual for detailed diagram).

4.3 Control Panel Installation (002ZL65)

  1. Install the control panel in a protected, easily accessible location, away from direct weather exposure.
  2. Connect the main power supply to the control panel.
  3. Connect the motor cables, photocells, flasher, and radio frequency board to the designated terminals on the control panel.

4.4 Photocell Installation (001DIR10)

  1. Mount the transmitter and receiver photocells opposite each other, ensuring a clear line of sight across the gate opening.
  2. Connect the photocell wiring to the control panel as per the wiring diagram.
  3. Test the photocells to ensure they detect obstructions correctly.

4.5 LED Flasher Installation (001KLED24)

  1. Mount the LED flasher in a visible location using the 001KIAROS wall mounting bracket.
  2. Connect the flasher to the control panel.

4.6 Dyagram fil elektrik

A detailed wiring diagram is crucial for correct installation. Please refer to the specific diagram included with your 002ZL65 Control Panel. Ensure all connections are secure and correctly polarized.

Figi 3: Egzample wiring diagram for the 002ZL65 control panel. (Image not provided, refer to product manual for detailed diagram).

5. Operasyon Enstriksyon

Once installed and configured, the gate system can be operated using the provided transmitters.

5.1 Programming Transmitters (001TOP-432EE)

To program the 001TOP-432EE transmitters with the 002ZL65 control panel:

  1. Access the programming mode on the 002ZL65 control panel (refer to the control panel manual for specific button sequences).
  2. Press the desired button on the 001TOP-432EE transmitter. The control panel will confirm successful programming (e.g., via an LED indicator or sound).
  3. Repeat for all desired transmitters.
  4. Exit programming mode on the control panel.

5.2 Operasyon debaz

6. Antretyen

Regular maintenance ensures the longevity and safe operation of your Came swing gate kit.

NAN. Depanaj

This section addresses common issues you might encounter. For more complex problems, contact a qualified technician.

Pwoblèm Kòz posib Solisyon
Gate does not respond to transmitter. No power to control panel; Transmitter battery low/dead; Transmitter not programmed; Photocell obstruction. Check power supply; Replace transmitter battery; Reprogram transmitter; Clear photocell path.
Baryè a rete oswa li fè bak sanzatann. Photocell obstruction; Safety edge activated; Motor overload. Clear photocell path; Check safety edges; Reduce gate friction or consult technician.
LED flasher does not operate. Loose connection; Faulty bulb/LED; Control panel issue. Check wiring connections; Replace flasher unit; Consult control panel manual.
Baryè a ap deplase dousman oswa avèk difikilte. Mechanical friction; Low voltage; Motor issue. Lubricate gate hinges/moving parts; Check power supply; Contact technician.

8. Espesifikasyon teknik

Karakteristik Spesifikasyon
Product Model (Kit) 8K01MP-012 AXI20K05
Manifakti Vini
Gate Length (Max per leaf) 2 mèt
Opere Voltage 24V DC
Frekans transmetè 433.92 MHz
Ranje Photocell 10 mèt
Component Model Number (e.g., control panel) 88001-0067 (Note: This may refer to a specific component within the kit, not the entire kit.)
Component Dimensions (e.g., control panel) 24 x 16 x 7 cm (Note: This may refer to a specific component within the kit.)
Component Weight (e.g., control panel) 240 g (Note: This may refer to a specific component within the kit.)
Batri obligatwa Yes (for transmitters)
Premye Dat ki disponib 9 mas 2019

9. Garanti ak sipò

For specific warranty terms and conditions, please refer to the documentation provided with your purchase or contact Came customer support directly. Warranty periods typically cover manufacturing defects under normal use.

For technical assistance, spare parts, or professional service, please contact your authorized Came dealer or visit the official Came website. Ensure you have your product model number and purchase date available when seeking support.

No official product videos from the seller were found in the provided data. For visual guides, please check the manufacturer's official channels or consult your installer.

Dokiman ki gen rapò - 8K01MP-012 AXI20K05

Preview Gid Enstalasyon Rapid pou Twous Otomatizasyon Baryè Balansè CAME ATS 8K01MP-0400 la
Gid konplè pou enstalasyon rapid pou twous automatisation pòtay baskil CAME ATS 8K01MP-0400 la, ki detaye enstalasyon, komisyonin, karakteristik sekirite, ak akseswa opsyonèl pou sistèm pòtay otomatik yo.
Preview Gid Enstalasyon Rapid pou Twous Otomatizasyon Baryè Balansè CAME ATS 8K01MP-0402 la
Gid sa a bay yon konfigirasyon rapid pou twous automatisation pòtay baskil CAME ATS 8K01MP-0402 la. Li kouvri sa ki nan twous la, enstriksyon sekirite, konfigirasyon tipik pòtay la, jeyometri, deblokaj manyèl, fil elektrik, enfòmasyon sou kat SIM, limen, komisyonin atravè aplikasyon ak panèl, opsyon sekirite, ranplasman SIM, ak akseswa opsyonèl. Fèt pou pòtay jiska 400kg pa fèy ak 5m lajè.
Preview Manyèl Enstalasyon Panèl Kontwòl CAME ZLX24SA/ZLX24SR
Manyèl enstalasyon pou panèl kontwòl CAME ZLX24SA ak ZLX24SR, ki fèt pou motè angrenaj 24V nan sistèm pòtay otomatik. Li bay gid sekirite esansyèl, espesifikasyon teknik, dyagram fil elektrik, ak enstriksyon pwogramasyon.
Preview CAME ATS-P5 Kit - Quick Setup Guide for Swing Gates
Comprehensive quick setup guide for the CAME ATS-P5 Kit, detailing installation, safety, wiring, programming, and accessories for swing gates up to 400kg per leaf and 5m width.
Preview Manyèl Enstalasyon Panèl Kontwòl CAME ZLJ24
Manyèl enstalasyon konplè pou panèl kontwòl CAME ZLJ24 la, ki fèt pou operatè pòtay baskil 24V DC. Li kouvri karakteristik teknik, koneksyon elektrik, pwogramasyon, sekirite ak depanaj.
Preview Manyèl Enstalasyon Otomatizasyon Pòtay Glisman CAME SDN4-SDN10
Manyèl enstalasyon konplè pou sistèm automatisation pòtay glisman CAME SDN4, SDN6, SDN8, ak SDN10, ki kouvri sekirite, enstalasyon, fil elektrik, pwogramasyon, ak depanaj. Gen ladan l espesifikasyon teknik ak gid operasyonèl.