EPEVER TRIRON 4210N

EPEVER TRIRON 4210N 40A MPPT Solar Charge Controller and MT50 Remote Meter User Manual

Model: TRIRON 4210N

This manual provides essential information for the safe and efficient operation of your EPEVER TRIRON 4210N 40A MPPT Solar Charge Controller and MT50 Remote Meter. Please read thoroughly before installation and use.

1. Pwodwi souview

The EPEVER TRIRON 4210N is a 40A Maximum Power Point Tracking (MPPT) solar charge controller designed for 12V/24V DC systems. It efficiently manages power from solar panels to charge various battery types, including lead-acid (Sealed, Gel, Flooded, User) and lithium (LiFePO4, Li-NiCoMn, Lithium User). This set includes the TRIRON 4210N controller and the MT50 Remote Meter for enhanced monitoring and control.

Karakteristik kle:

  • Advanced MPPT technology for high tracking efficiency.
  • Modular design for flexible configuration with different display and interface modules.
  • Supports multiple battery types: Sealed (AGM), Gel, Flooded, Lead-acid User, LiFePO4 Lithium, Li(NiCoMn)O2 Lithium, Lithium User (9~34V).
  • Negative ground design for broad application compatibility.
  • Dual 5V DC USB output interface (Max 2.2A) for charging electronic devices.
  • Kat-stage charging (bulk, absorption, float, equalization) to prolong battery life.
  • Comprehensive electronic protection features.
  • Fonksyon an tan reyèl estatistik enèji.

Kontni pake:

Pake a anjeneral gen ladan:

  • EPEVER TRIRON 4210N MPPT Solar Charge Controller
  • EPEVER MT50 Remote Meter
  • Remote Temperature Sensor (RT-S)
  • USB to RS485 Communication Cable
  • Manyèl itilizatè
EPEVER TRIRON 4210N Solar Charge Controller and MT50 Remote Meter package contents

Image: Contents of the EPEVER TRIRON 4210N and MT50 Remote Meter package, including the controller, remote meter, temperature sensor, and cables.

2. Enfòmasyon sou Sekirite

Tanpri li tout enstriksyon ak avètisman yo ak anpil atansyon anvan enstalasyon ak itilizasyon. Si ou pa swiv enstriksyon sa yo, ou ka pran chòk elektrik, pran dife oswa pran gwo blesi.

  • Ensure all wiring is correctly polarized and securely connected. Loose connections can cause overheating and fire.
  • Always connect the battery to the charge controller first, then the solar panel, and finally the load. Disconnect in the reverse order.
  • Do not attempt to repair or modify the controller. Refer servicing to qualified personnel.
  • Enstale kontwolè a nan yon zòn ki byen ayere, lwen materyèl ki ka pran dife ak gaz koroziv.
  • Wear appropriate personal protective equipment (PPE), including eye protection and insulated gloves, when working with batteries and solar panels.
  • Asire sistèm voltage is compatible with the controller's specifications (12V/24V auto work).
  • Sèvi ak disjonktè oswa fizib ki apwopriye pou tout koneksyon pou anpeche twòp kouran.

3. Enstalasyon

3.1 Monte kontwolè a

Mount the controller vertically on a flat, non-flammable surface in a dry, well-ventilated indoor area. Ensure there is sufficient clearance around the controller for heat dissipation. The recommended clearances are 150mm (5.9 inches) above and below the unit.

EPEVER TRIRON 4210N Solar Charge Controller dimensions and mounting recommendations

Image: Controller dimensions and recommended mounting clearances for proper ventilation.

3.2 Koneksyon fil elektrik

Follow the wiring sequence carefully to prevent damage to the controller or other components. Always ensure all power sources are disconnected before making or breaking connections.

  1. Konekte batri a: Connect the battery cables to the controller's battery terminals (marked with '+' and '-'). Ensure correct polarity. Always connect the battery first.
  2. Konekte panèl solè a: Connect the solar panel cables to the controller's PV terminals (marked with solar panel icon and '+' and '-'). Ensure correct polarity.
  3. Konekte chaj DC a: Connect the DC load cables to the controller's load terminals (marked with light bulb icon and '+' and '-'). Ensure correct polarity.
  4. Connect Remote Temperature Sensor: Plug the remote temperature sensor into the designated port on the controller. Secure the sensor to the battery case for accurate temperature compensation.
EPEVER TRIRON 4210N Solar Charge Controller wiring diagram

Image: Detailed wiring diagram showing connections for solar panels, battery, and DC load to the TRIRON 4210N controller.

Video: This video demonstrates the unboxing, component identification, and step-by-step installation process for the EPEVER TRIRON 4210N solar charge controller, including wiring the battery, solar panel, and remote temperature sensor.

3.3 Connecting the MT50 Remote Meter

The MT50 Remote Meter connects to the controller via an RJ45 communication cable. This allows for remote monitoring of system status and parameter settings.

  • Connect one end of the RJ45 cable to the RS485 port on the TRIRON 4210N controller.
  • Connect the other end of the RJ45 cable to the corresponding port on the MT50 Remote Meter.

3.4 Entèfas kominikasyon

The TRIRON 4210N features an RS485 communication port, allowing connection to various accessories for extended functionality:

  • Lojisyèl PC: Connect via an RS485 to USB adapter cable for monitoring and parameter configuration using PC software.
  • Aplikasyon mobil: Connect via an eBox-WIFI-01 or eBox-BLE-01 module for wireless monitoring and control through a mobile application.

4. Operasyon

4.1 Ekran LCD ak bouton

The controller features an LCD display and five buttons for viewing system parameters and making adjustments.

EPEVER TRIRON 4210N Solar Charge Controller LCD display screens

Image: Various screens displayed on the TRIRON 4210N LCD, showing PV voltage, current, battery status, and load information.

  • Bouton PV/+: Used to navigate forward through display screens or increase parameter values.
  • BATT/→ Button: Used to navigate right through display screens or move cursor during parameter setting.
  • Bouton CHARJE/-: Used to navigate backward through display screens or decrease parameter values.
  • SET bouton: Used to enter parameter setting mode or confirm a setting.
  • ESC bouton: Used to exit parameter setting mode or return to the previous screen.

4.2 Anviwònman Paramèt

To adjust parameters such as battery type, capacity, and temperature unit, use the navigation buttons to access the setting menus. Press the SET button to enter edit mode, use PV/+ and LOAD/- to change values, and SET again to confirm. Refer to the detailed instructions in the included user manual for specific parameter adjustments.

4.3 USB Sòti

The controller is equipped with dual 5V DC USB ports (Max 2.2A) for charging compatible electronic devices. These ports are active when the controller is powered by the battery.

5. Antretyen

Antretyen regilye asire pèfòmans optimal ak lonjevite kontwolè chaj solè ou a.

  • Tcheke Koneksyon: Periodically inspect all wiring connections for tightness and corrosion. Tighten any loose connections.
  • Netwaye Kontwolè a: Keep the controller clean and free from dust and debris. Ensure the heat sink fins are not obstructed to allow for proper cooling.
  • Enspekte Câbles: Check all cables for signs of wear, damage, or insulation degradation. Replace damaged cables immediately.
  • Enspeksyon batri: Pou pil plon-asid, tcheke nivo elektwolit yo ak kondisyon tèminal yo dapre direktiv manifakti pil la.
  • Mizajou lojisyèl: Tcheke manifakti a website for any available firmware updates for your controller.

NAN. Depanaj

This section provides basic troubleshooting steps for common issues. For more complex problems, consult the full user manual or contact EPEVER technical support.

Pwoblèm komen ak solisyon:

  • Pa gen ekspozisyon/Pa gen kouran:
    • Tcheke koneksyon batri yo epi asire w ke yo byen fèm epi yo byen polarize.
    • Verify batri voltage a nan ranje fonksyònman kontwolè a.
  • No Charging from Solar Panel:
    • Check solar panel connections and polarity.
    • Ensure sufficient sunlight is reaching the solar panels.
    • Verify solar panel open circuit voltage (Voc) is within the controller's input range.
  • Chaj la pa fonksyone:
    • Tcheke koneksyon chaj yo ak polarite a.
    • Ensure the load is not exceeding the controller's rated load current.
    • Tcheke batri voltage; the load may be disconnected if the battery voltage twò ba.
  • Incorrect Battery Readings:
    • Verify the remote temperature sensor is correctly connected and placed near the battery.
    • Ensure the correct battery type and capacity are set in the controller's parameters.

7. Espesifikasyon

ParamètValè
ModèlTRIRON4210N-mppt
Sistèm Voltage12/24VDC Auto Work
Rated chaj aktyèl40A
Batri Antre Voltage Range8-32V
Max. PV Open Circuit Voltage100V (Min operating environment temp); 92V (25℃ environment temp)
MPP Voltage Range(Vbat+2V) ~ 72V
Max. PV Array Power Support520W (12V battery); 1040W (24V battery)
Tanperati anviwònman k ap travay-25℃ ~ +55℃ (with LCD) / -30℃ ~ +55℃ (without LCD)
Lithium Battery Types SupportedLiFePO4 (4 series; 8 series) / Li-NiCoMn (3 series; 6 series) / User (Lithium battery setting requires RS485 or WIFI BOX)
Lead-acid Battery Types SupportedSealed (AGM), Gel, Flooded, Lead-acid User
Oto-konsomasyon≤14mA (12V); ≤15mA (24V)
Konpansasyon Tanperati-3mV / ℃ / 2V
AtèKomen negatif
Terminals/Wire Size6AWG (16mm²)
USB SòtiDual 5V DC, Max 2.2A
Pwa atik6.69 liv
Dimansyon pake17.56 x 8.43 x 4.88 pous
UPC655160074776

8. Garanti ak sipò

For warranty information and technical support, please refer to the documentation included with your product or visit the official EPEVER websit la. Kenbe resi acha ou kòm prèv acha pou reklamasyon garanti.

Dokiman ki gen rapò - TRIRON 4210N

Preview Gid depanaj EPEVER Tracer-AN (10~40A)
Yon gid konplè pou depanaj pou kontwolè chaj solè seri EPEVER Tracer-AN (10-40A), ki kouvri defo komen, pwoblèm koneksyon, ak tès konpozan.
Preview Kontwolè chaj MPPT modilè seri EPEVER TRIRON
Enfòmasyon detaye sou seri kontwolè chaj solè modilè MPPT EPEVER TRIRON yo, ki gen ladan modèl pwodwi, karakteristik, fonksyon pwoteksyon, règ nonmen, modil koòdone, akseswa, ak paramèt elektrik.
Preview EPEVER Tracer-CPN MPPT Solar Charge Controller Manual
User manual for the EPEVER Tracer-CPN series MPPT solar charge controllers, detailing features, appearance, wiring, protections, troubleshooting, and technical specifications. Supports lead-acid and lithium batteries.
Preview EPEVER Tracer BP MPPT Solar Charge Controller User Manual & Technical Specifications
Explore the EPEVER Tracer BP MPPT Solar Charge Controller user manual, featuring advanced Maximum Power Point Tracking technology for efficient solar charging. Learn about its features, wiring, LED indicators, load working modes, comprehensive protection mechanisms, troubleshooting, and detailed technical specifications for various battery types including sealed, gel, flooded, and lithium batteries. Ideal for solar home systems, traffic signals, solar street lights, and garden lamps.
Preview EPEVER TRIRON N-serien: Moduluppbyggd MPPT Solcellsregulator Bruksanvisning
Denna bruksanvisning ger detaljerad information om EPEVER TRIRON N-seriens moduluppbyggda MPPT solcellsregulatorer, inklusive installation, säkerhet, funktioner och tekniska specifikationer för optimal solenergiutvinning.
Preview Manyèl Kontwolè Chaj Solè MPPT Seri EPEVER Tracer BP
Manyèl konplè pou kontwolè chaj solè MPPT seri EPEVER Tracer BP a, ki kouvri enfòmasyon sekirite, plis paseview, karakteristik pwodwi, fil elektrik, endikatè LED, mòd travay chaj, pwoteksyon, depanaj, ak espesifikasyon teknik.