LUNOS localization_B07MQ62LLD

Lunos e² Decentralized Ventilation System User Manual

Model: localization_B07MQ62LLD

Entwodiksyon

This manual provides essential information for the installation, operation, and maintenance of your Lunos e² decentralized ventilation system. Please read this manual thoroughly before installation and operation to ensure proper function and safety. Keep this manual for future reference.

The Lunos e² system is a highly efficient, decentralized ventilation unit with heat recovery, designed for room-by-room ventilation. It operates on a reversible airflow principle using a ceramic regenerator, ensuring low energy consumption and quiet operation.

Pwodwi konpozan

Eksploze view of Lunos e² ventilation unit components and accessories

Figi 1: Eksploze view of the Lunos e² decentralized ventilation units and accompanying accessories. This image shows two complete ventilation units, two round ducts, a universal control unit, a power supply, and a wall switch. Each ventilation unit consists of an outer grille, a fan, a ceramic heat exchanger, and an inner panel with a filter.

The Lunos e² system includes:

Enstalasyon ak Enstalasyon

Installation should be performed by a qualified professional. Ensure all local building codes and regulations are followed.

Chèk anvan enstalasyon:

Etap enstalasyon:

  1. Drill a 162 mm diameter hole through the wall at the desired location, ensuring a slight downward slope to the outside for drainage.
  2. Insert the round duct (DN160 mm) into the drilled hole. Cut the duct to the appropriate length for the wall thickness.
  3. Install the Lunos e² ventilation unit into the duct. Ensure the ceramic heat exchanger and fan are correctly oriented.
  4. Mount the exterior grille (1-WE 180) on the outside of the wall, securing it with screws.
  5. Mount the interior panel with filter (9/IBE) on the inside of the wall.
  6. Connect the ventilation units to the 5/UNI-FT universal control unit.
  7. Connect the 5/NT18 power supply to the universal control unit and to the main power.
  8. Install the 5/W2U switch in a convenient location and connect it to the universal control unit.

Enstriksyon Operasyon

The Lunos e² system is designed for continuous operation to maintain optimal indoor air quality and heat recovery.

Operasyon debaz:

Mòd operasyon:

The Lunos e² system typically offers multiple fan speed settings to adjust ventilation rates:

The system also features humidity recovery, typically around 20-30%, to prevent excessive drying of indoor air during colder months.

Antretyen

Regular maintenance ensures optimal performance and longevity of your Lunos e² ventilation system.

Filter Replacement/Cleaning:

The G3 filter should be checked regularly and replaced or cleaned as needed, typically every 3-6 months depending on air quality.

  1. Turn off the ventilation system at the main switch.
  2. Carefully remove the interior panel.
  3. Remove the G3 filter.
  4. Clean the filter by vacuuming or gently washing with warm water (if washable type). Allow to dry completely before reinstallation. Replace if heavily soiled or damaged.
  5. Reinsert the clean/new filter and reattach the interior panel.
  6. Remete sistèm nan.

Ceramic Heat Exchanger Cleaning:

The ceramic heat exchanger should be cleaned annually or if performance degrades.

  1. Turn off the ventilation system.
  2. Remove the interior panel and filter.
  3. Carefully pull out the ceramic heat exchanger unit.
  4. Clean the ceramic core under running water. Do not use harsh detergents. Allow to dry completely.
  5. Reinsert the dry ceramic heat exchanger, ensuring correct orientation.
  6. Reinstall the filter and interior panel.
  7. Remete sistèm nan.

Exterior Grille Cleaning:

Periodically inspect and clean the exterior grille to ensure unobstructed airflow.

Depanaj

If you experience issues with your Lunos e² system, consult the following table before contacting support.

PwoblèmKòz posibSolisyon
System not operatingNo power supply; switch is OFF.Check power connection; ensure switch is ON. Verify power supply (5/NT18) is functioning.
Reduced airflow or efficiencyClogged filter; dirty ceramic heat exchanger; obstructed exterior grille.Clean or replace filter; clean ceramic heat exchanger; clear any obstructions from the exterior grille.
Bri etranjBlokaj vantilatè; konpozan ki lach.Turn off system and inspect fan for obstructions. Ensure all components are securely installed. If noise persists, contact support.
Kondansasyon ozalantou inite aImproper installation (e.g., no downward slope); extreme temperature difference.Ensure proper installation with slight downward slope. If problem persists, consult a professional.

Espesifikasyon

Detailed technical specifications for the Lunos e² decentralized ventilation system.

Lunos e² Energy Label

Figi 2: Energy label for the Lunos e² ventilation system, indicating an A+ energy efficiency rating, 40 dB sound level, and a maximum airflow of 38 m³/h.

Lunos e² Product Data Sheet

Figi 3: Product data sheet for the Lunos e² ventilation system, detailing specifications such as supplier, model identification, specific energy consumption, type of heat recovery, thermal efficiency, maximum flow rate, power input, sound pressure level, and annual energy consumption.

ParamètValè
ModèlLunos e²
Efikasite Rekiperasyon Chalè90.6%
Airflow Volume (m³/h)18 / 31 / 38
Power Consumption per unit (W)1.4 / 2.8 / 3.3
Rated Power (W/m³/h)0.09
Network Voltage12 V DC
Humidity RecoveryApprox. 20-30%
Nivo Presyon Son (dB)16.5 / 19.5 / 26
Normal Sound Level (DN,W, open)42 dB
Longè inite243 mm
Minimum Wall Thickness300 mm
Dyamèt twou162 mm

Garanti ak sipò

For warranty information, please refer to the documentation provided with your purchase or contact Lunos directly. Keep your proof of purchase for warranty claims.

For technical support, spare parts, or further assistance, please contact Lunos customer service. Contact details can typically be found on the manufacturer's official websit la oubyen sou fakti acha ou a.

Manifakti: Lunos

Websit: www.lunos.de

Dokiman ki gen rapò - localization_B07MQ62LLD

Preview LUNOS Nexxt Decentralised Ventilation System Installation Manual
Comprehensive installation guide for the LUNOS Nexxt decentralized ventilation system with heat recovery, covering technical specifications, mounting, electrical connections, DIP switch settings, filter replacement, and maintenance.
Preview LUNOS e² Series Decentralised Ventilation System Installation Manual
Installation manual for the LUNOS e² Series decentralized ventilation system with heat recovery. Includes technical specifications, electrical connection diagrams, and installation guidelines.
Preview LUNOS Series e² Decentralised Ventilation System with Heat Recovery - Installation Manual
Comprehensive installation manual for the LUNOS Series e² decentralised ventilation system with heat recovery. Covers product details, technical specifications, electrical connections, installation guidelines, and maintenance for models like e², e²kurz, e²60, and e²60kurz.
Preview LUNOS 5/UNI-FT & 5/UNI-RF Universal Control Installation Manual
Installation manual for the LUNOS 5/UNI-FT and 5/UNI-RF Universal Control system, detailing features, technical specifications, electrical connections, coding switch settings, and operational modes for ventilation systems.
Preview LUNOS Ventilation System Commissioning Protocol
A detailed checklist protocol for the commissioning of LUNOS ventilation systems, ensuring proper installation, component verification, and functional testing for a successful system handover.
Preview Gid paramèt pou kontwolè inivèsèl LUNOS 5/UNI-FT
Gid konplè pou Kontwolè Inivèsèl LUNOS la (Tip: 5/UNI-FT, No.:40269), ki kouvri karakteristik, espesifikasyon teknik, koneksyon elektrik, paramèt kadran, ak enstriksyon pou manyen pou yon jesyon sistèm vantilasyon optimal.