Entwodiksyon
This manual provides essential information for the safe installation, operation, and maintenance of your Akicon BPT16-14EL-L12 Bathroom Exhaust Fan with LED Light. Please read these instructions thoroughly before installation and use, and retain them for future reference.
The Akicon BPT16-14EL-L12 exhaust fan is designed to effectively remove moisture and odors from bathrooms and similar indoor spaces up to 85 square feet. It features a quiet operation at 1.5 sones and an integrated 12W LED light for illumination.

Deskripsyon imaj: Yon bò devan view of the Akicon BPT16-14EL-L12 bathroom exhaust fan, showcasing its white grille cover with integrated LED light and the metal housing with a black duct connector.
Enfòmasyon sou Sekirite
AVÈTISMAN: Pou diminye risk pou dife, chòk elektrik, oswa blesi sou moun, obsève sa ki annapre yo:
- Travay enstalasyon ak fil elektrik dwe fèt pa moun ki kalifye (yo) an akò ak tout kòd aplikab ak estanda, ki gen ladan kòd konstriksyon dife-rated ak estanda.
- Toujou dekonekte kouran an nan panèl sèvis la anvan ou konekte fil elektrik yo oswa fè antretyen sou aparèy la.
- This unit is HVI-certified and cUL listed for use over bathtubs and showers when connected to a GFCI (Ground Fault Circuit Interrupter) protected branch circuit.
- Pa sèvi ak fanatik sa a avèk nenpòt aparèy kontwòl vitès solid.
- Never place any object into the fan blades.
- Asire w ke vantilatè a byen konekte ak tè a.
- Duct work must be installed with a minimum number of turns and runs to ensure optimal airflow.
Kontni pake
Verifye ke tout konpozan yo prezan anvan ou kòmanse enstalasyon an:
- Exhaust Fan Housing Assembly
- Grille Cover with Integrated LED Light
- 12W E26 Base LED Bulb (pre-installed or separate)
- Installation Hardware (screws, wire connectors)
- Manyèl Itilizatè (dokiman sa a)
Espesifikasyon
| Karakteristik | Spesifikasyon |
|---|---|
| Mak | Akicon |
| Nimewo Modèl | BPT16-14EL-L12 |
| Kapasite Flow Air | 90 pye kib pou chak minit (CFM) |
| Nivo bri | 1.5 son |
| Sous pouvwa | AC |
| Voltage | 120 Volts |
| Ki ap dirije limyè Wattage | 12 Watts |
| Dirije limyè Koulè Tanperati | 5000K (Blan fre) |
| Dimansyon Lojman (L x W x H) | 9-3/8" x 9-3/8" x 7-5/16" |
| Grille Cover Size | 11" x 11" |
| Gwosè kanal | 4 pous wonn |
| Gwosè chanm rekòmande | Jiska 85 pye kare. |
| Sètifikasyon | HVI, cUL Listed |
| Pwa atik | 8.83 liv |
Enstalasyon ak Enstalasyon
This section outlines the general steps for installing the Akicon BPT16-14EL-L12 exhaust fan. For detailed diagrams and specific instructions, refer to the included installation guide or consult a qualified electrician.
1. Konsiderasyon Pre-Enstalasyon
- Measure Room Size: Ensure the fan's 90 CFM capacity is suitable for your room (up to 85 sq. ft.).
- Ouvèti plafon: The recommended ceiling opening size is approximately 9-7/8" x 9-7/8". If replacing an existing fan, measure the current opening. If the existing opening is smaller, it will need to be enlarged to accommodate the new housing.
- Kanal: Plan for a 4-inch round duct connection. Use rigid metal ducting for best performance.
- Fil elektrik: Ensure a 120V AC power supply is available. The fan and light can be wired to operate jointly or separately via wall switches.

Deskripsyon imaj: This image displays the critical dimensions for installation. It shows the fan housing size as 9-3/8" x 9-3/8" x 7-5/16", the grille cover size as 11" x 11", and the recommended ceiling opening size as 9-7/8" x 9-7/8". This helps ensure proper fit during installation.

Deskripsyon imaj: An installation notice highlighting the housing dimensions (9.4" x 9.4" x 7.7") and emphasizing that the opening hole size should be based on the housing size. It advises checking existing opening sizes for replacements and cutting the hole to match the new housing if necessary.
2. Mounting the Fan Housing
- Fèmen kouran nan disjoncteurs a.
- Cut the ceiling opening to the specified dimensions (approx. 9-7/8" x 9-7/8").
- Secure the fan housing to ceiling joists using appropriate fasteners. The housing is designed for screw-in installation. Ensure it is firmly attached to prevent vibration and noise.

Deskripsyon imaj: This diagram shows two common installation scenarios: attic and soffit. It illustrates how the fan can be ducted to exhaust air outside, emphasizing the importance of proper ducting for effective ventilation.
3. Koneksyon kanal
- Connect a 4-inch round duct to the fan's exhaust collar. Secure with duct tape or clamps.
- Route the duct to an exterior vent cap, ensuring minimal bends and a slight downward slope away from the fan to prevent condensation buildup.

Deskripsyon imaj: A comprehensive installation diagram showing the fan housing, duct connection, and electrical wiring points. It provides a visual guide for the step-by-step installation process within a ceiling.
4. Fil elektrik
- Open the wiring compartment on the fan housing.
- Connect the household wiring to the fan's wiring according to local electrical codes. The fan and light have separate wires, allowing for independent operation if desired (e.g., separate wall switches for fan and light).
- Ensure all connections are secure and properly insulated. Close the wiring compartment cover.
5. Install Grille Cover
- If the LED bulb is not pre-installed, screw the 12W E26 base LED bulb into the socket.
- Attach the grille cover to the fan housing. Typically, this involves inserting mounting springs into slots in the housing and pushing the grille firmly against the ceiling.
Once installation is complete, restore power at the circuit breaker and test the fan and light functions.
Enstriksyon Operasyon
The Akicon BPT16-14EL-L12 exhaust fan and LED light are designed for simple operation via standard wall switches.
- Operasyon Fan: Flip the designated wall switch to turn the exhaust fan ON or OFF.
- Limyè operasyon: Flip the designated wall switch to turn the LED light ON or OFF.
- If wired separately, the fan and light can be controlled independently. If wired jointly, both will activate simultaneously.
For optimal moisture and odor removal, operate the fan during and after showering or bathing for at least 15-20 minutes.
Antretyen
Regular maintenance ensures optimal performance and longevity of your exhaust fan. Always disconnect power at the circuit breaker before performing any maintenance.
1. Cleaning the Grille Cover
- Rale kouvèti griy la dousman pou detache li nan sous lojman an.
- Wash the grille cover with mild soap and water. Rinse thoroughly and dry completely before reattaching.

Deskripsyon imaj: Yon detaye view of the fan's white grille cover, showing the ventilation slots and the central LED light panel. This component is easily removable for cleaning.
2. Cleaning the Fan Interior
- With the grille removed and power off, carefully wipe down the fan blades and interior of the housing with a damp twal.
- Do not allow water to enter the motor or electrical components.
- Asire w tout pyès yo sèch anvan ou retabli kouran an.
3. LED Bulb Replacement
- Asire w ke pouvwa a koupe.
- Remove the grille cover.
- Unscrew the old E26 base LED bulb and replace it with a new 12W E26 base LED bulb.
- Reattach the grille cover and restore power.
Depanaj
If you encounter issues with your Akicon exhaust fan, refer to the following common problems and solutions:
| Pwoblèm | Kòz posib | Solisyon |
|---|---|---|
| Vantilatè a pa mache / Limyè a pa limen | No power supply; Loose wiring; Faulty switch; Blown fuse/tripped breaker | Check power at the circuit breaker. Ensure all wiring connections are secure. Test the wall switch. Replace fuse or reset breaker. |
| Vantilatè a fè twòp bri | Loose mounting; Obstruction in fan blades; Dirty fan blades/motor; Improper ducting | Ensure fan housing is securely mounted. Disconnect power and check for obstructions. Clean fan blades and motor. Inspect ductwork for kinks or blockages. |
| Poor ventilation performance | Ducting issues (too long, too many bends, wrong size); Blocked exterior vent; Room size exceeds fan capacity | Inspect ductwork for proper installation and clear any blockages. Ensure exterior vent is clear. Verify fan CFM matches room size. |
| LED light flickers or is dim | Loose bulb; Faulty bulb; Wiring issue | Ensure bulb is screwed in tightly. Replace the LED bulb. Check electrical connections to the light. |
If the problem persists after attempting these solutions, please contact Akicon customer support.
Enfòmasyon sou Garanti
The Akicon BPT16-14EL-L12 Bathroom Exhaust Fan with LED Light comes with a 3-ane garanti limite soti nan dat acha a. Garanti sa a kouvri domaj nan materyèl ak atizan konn fè nan itilizasyon nòmal.
The warranty does not cover damage resulting from improper installation, misuse, abuse, accident, neglect, or unauthorized repair or modification. Proof of purchase is required for all warranty claims.
Sipò pou Kliyan
For any questions, technical assistance, or warranty claims, please contact Akicon customer service. Have your model number (BPT16-14EL-L12) and proof of purchase ready when contacting support.
Contact information can typically be found on the Akicon official websit la oubyen atravè platfòm acha ou a.