The Elitech ILD-100H is an advanced HVAC refrigerant leak detector designed for precise and efficient detection of various halogenated refrigerants. Utilizing a heated diode sensor, it offers enhanced accuracy and reliability compared to traditional sensors. This manual provides detailed instructions for the proper setup, operation, maintenance, and troubleshooting of your ILD-100H detector, ensuring optimal performance and longevity.

This device is suitable for detecting a wide range of refrigerants, including CFCs, HFCs, HCFCs, HCs, HFOs, and mixed refrigerants such as R11, R22, R404a, R410a, R600a, R1234yf, and various blends like AZ-50, HP62, and MP39. It boasts an immediate response time, making leak detection quick and effective.

2. Karakteristik kle

  • Heated Diode Sensor: Provides superior accuracy for all halogenated refrigerants, ensuring reliable detection results.
  • TFT ekran: The innovative TFT screen offers clear and easy-to-read information, including sensitivity levels, leakage alerts, and battery status, enhancing operational clarity.
  • Segondè sansiblite: Features adjustable sensitivity with High, Medium, and Low levels. The maximum sensitivity reaches up to 0.1 oz/yr, allowing for the detection of even minute leaks.
  • Operasyon rapid: Equipped with two intuitive buttons on the front panel for rapid adjustment of sensitivity and direct muting of the buzzer, simplifying user interaction.
  • Konpatibilite laj ak frijidè: Capable of detecting all types of halogenated refrigerants, including HFCs (R134a, R410A, R407C, R417A, R404A, R507, R23, R508A, R508B, R152A, R32), HCFCs (R22, R123, R124, R141b, R142b, R402A, R402B, R408A, R409A), CFCs (R11, R12, R13, R502, R503), PFCs (PFC-14, PFC-116, PFC-218), and HFOs (R-1234yf), as well as HCs (R50, R170, R290, R600, R600A, R1150, R1270).
Elitech ILD-100H Halogen Leak Detector highlighting adjustable sensitivity, audible & light alarm, immediate response, and two different modes.

Figi 2.1: Plis paseview of Elitech ILD-100H key features.

3. Konpozan pwodwi ak dimansyon

Elitech ILD-100H with labeled components including flexible probe, UV LED, filter components, display screen, buttons, and buzzer.

Figure 3.1: Labeled components of the Elitech ILD-100H.

Elitech ILD-100H dimensions showing 7.9 inches height, 3.3 inches width, 1.5 inches depth, and a 14-inch probe length. Also lists max sensitivity, response time, battery, and compliance standards.

Figure 3.2: Physical dimensions and key performance specifications.

4. Enstalasyon

  1. Debake: Carefully remove the Elitech ILD-100H and all accessories from the packaging. Inspect for any signs of damage.
  2. Chaje batri: The device includes a Lithium Metal battery. Before first use, ensure the battery is fully charged. Connect the appropriate charging cable (not specified in data, assume standard USB-C based on reviews) to the device and a power source. The TFT screen will indicate charging status.
  3. Sensor Preparation: Ensure the flexible probe and filter components are securely attached. The heated diode sensor requires a brief warm-up period after powering on.
Elitech ILD-100H Refrigerant Leak Detector, a handheld device with a flexible probe and a digital display.

Figure 4.1: Elitech ILD-100H ready for setup.

5. Operasyon Enstriksyon

  1. Pouvwa sou: Press the 'ON/OFF' button to power on the device. The TFT screen will illuminate and display a warm-up countdown.
  2. Chofe: Allow the device to complete its warm-up cycle (typically 20 seconds as seen in image). This ensures the heated diode sensor reaches optimal operating temperature for accurate detection.
  3. Chwazi sansiblite: Use the 'SENS' button to cycle through the sensitivity levels: High (H), Medium (M), and Low (L). Higher sensitivity is recommended for detecting smaller leaks or for initial scanning.
  4. Deteksyon koule: Slowly move the flexible probe around suspected leak areas. The device will provide visual alerts on the TFT screen (e.g., bar graph, curve display) and an audible alarm when a leak is detected. The intensity of the alarm and display will increase with higher leak concentrations.
  5. Pinpoint vs. Curve Display: The TFT screen offers two display modes. The 'Pinpoint Display' helps in finding the exact leak location, while the 'Curve Display' assists in quickly identifying the general leak area.
  6. Mute Buzzer: Press the 'MUTE' button to silence the audible alarm if needed.
  7. Pouvwa Off: Press and hold the 'ON/OFF' button to power off the device after use.
Elitech ILD-100H display modes showing Pinpoint Display for exact leak location and Curve Display for general leak area.

Figure 5.1: Understanding the Pinpoint and Curve Display modes for leak identification.

Elitech ILD-100H detecting various halogenated refrigerants including HFC, HCFC, CFC, PFC, HFO, and HC types.

Figure 5.2: The ILD-100H's capability to detect a wide range of halogenated refrigerants.

Videyo 5.1: Yon overview of Elitech's AI HVAC/R tools, demonstrating the advanced capabilities and applications of their products, including the ILD-100H leak detector in action.

6. Antretyen

  • Netwayaj: Regularly wipe the exterior of the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Sensor and Filter Maintenance: The device features filter components (as shown in Figure 3.1). Refer to the full user manual (PDF link provided in product data) for specific instructions on cleaning or replacing the sensor and filter to maintain optimal performance.
  • Depo: Store the detector in a cool, dry place away from direct sunlight and extreme temperatures when not in use.

NAN. Depanaj

If you encounter issues with your Elitech ILD-100H, consider the following common troubleshooting steps:

  • Aparèy pa limen: Ensure the battery is fully charged. If the issue persists, try connecting the charger to confirm power supply.
  • Inaccurate Readings/No Detection: Check the sensor and filter for any obstructions or damage. Ensure the device has completed its warm-up cycle. Adjust sensitivity settings to a higher level if necessary.
  • Konpòtman iregilye: Ensure the device is not exposed to strong electromagnetic interference. Try restarting the device.

For persistent issues or complex problems, please refer to the comprehensive user manual or contact Elitech customer support.

8. Espesifikasyon

AtribiDetay
MakElitech
Nimewo ModèlILD-100H
StyleHeated Diode Sensor
Sous pouvwaBatri Powered
KoulèHeated Diode Sensor Ild-100h
Dimansyon pwodwi (D x W x H)1.5" x 3.3" x 7.9"
Pwa atik2.46 liv
Kalite AlamOu tande
Operasyon Imidite85 pousan
Evalyasyon Tanperati Upper20 Degre Sèlsiyis
Kalite CapteurIR
MateryèlPlastik
Max sansiblite0.1 oz/yr
Tan reponsImmediate (within 1s)
Kalite batriLithium Ion (1 Lithium Metal battery included)
Kapasite batri3.7V 3000mAh
ItilizasyonHVAC systems, refrigerant leak detection
Estanda KonfòmiteEN14624.5AE-162, SAE-2791, SAE-2913, CE
UPC704529988930, 704529989043

9. Garanti ak sipò

The Elitech ILD-100H Refrigerant Leak Detector comes with a 1-ane garanti soti nan dat acha a.

For any technical assistance, product inquiries, or warranty claims, Elitech offers 7x24 customer services. Please refer to the official Elitech website or the full user manual for contact details.

You can also download the complete user manual in PDF format for more detailed information: Telechaje Manyèl Itilizatè a (PDF)

Dokiman ki gen rapò - ILD-100H

Preview Elitech WJL-6000S Corona Detektè Manyèl Itilizatè
Manyèl itilizatè pou Detektè Corona Elitech WJL-6000S la, ki bay enstriksyon detaye sou operasyon, deteksyon, depanaj ak antretyen pou deteksyon flit refrijeran nan divès sistèm.
Preview Elitech ILD Seri enfrawouj detektè fwit frijidè manyèl itilizatè
Manyèl itilizatè konplè pou detektè flit frijidè enfrawouj seri Elitech ILD yo (ILD-100, ILD-200, ILD-300), ki kouvri espesifikasyon yo, operasyon an, antretyen an ak karakteristik yo. Aprann kijan pou detekte flit frijidè efektivman ak aparèy avanse sa a.
Preview Manyèl Itilizatè Detektè Fwit Enfrawouj Elitech ILD-100/ILD-200/ILD-300
Manyèl itilizatè pou detektè flit frijidè enfrawouj seri Elitech ILD (ILD-100, ILD-200, ILD-300). Li bay enfòmasyon detaye sou operasyon, espesifikasyon, karakteristik ak antretyen pou yon deteksyon flit frijidè ki egzat.
Preview Manyèl Itilizatè Detektè Fwit Frijidè Elitech LD-100 ak Dyòd Chofe
Manyèl itilizatè pou Detektè Fwit Frijidè ak Dyòd Chofe Elitech LD-100 la, ki detaye karakteristik li yo, operasyon li, ak antretyen li.
Preview Manyèl Itilizatè Detektè Fwit Dyòd Enfrawouj ak Chofe Elitech IR-200
Manyèl itilizatè konplè pou Elitech IR-200 la, yon detektè flit ak doub captè ki prezante teknoloji enfrawouj ak dyòd chofe. Aprann plis sou espesifikasyon li yo, operasyon li, antretyen li, ak karakteristik li yo pou detekte flit frijidè.
Preview Elitech HLD-200 Manyèl Itilizatè detektè alojene
This user manual provides comprehensive instructions for operating and maintaining the Elitech HLD-200 Halogen Leak Detector. It covers technical specifications, operation procedures, leak detection methods, troubleshooting, and maintenance tips for effective use in refrigeration and HVAC systems.